<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE subordleg PUBLIC "-//OQPC//DTD QuILLS Subordinate Legislation//EN" "Subordleg.dtd">
<!--************************************************************************************************************-->
<!--                                              DISCLAIMER                                                    -->
<!---->
<!--Queensland does not accept responsibility for the accuracy or completeness of material on this website      -->
<!--(or any other website referred to on this website) except as set out below. Users should exercise their     -->
<!--own skill and care in the use of the material.                                                              -->
<!---->
<!--No warranty is given that the material located on this site, or on any other site referred to on this site, -->
<!--is free from error or omission. Users should exercise their own skill and care with respect to the use of   -->
<!--the material. Accordingly, the State of Queensland and its servants and agents expressly disclaim liability -->
<!--for any act done or omission made in reliance on any such material and any consequences of any such act or  -->
<!--omission. This notice must not be erased.                                                                   -->
<!---->
<!--************************************************************************************************************-->
<subordleg title="Plumbing and Drainage Regulation 2019" year.published="2019" year.citation="2019" no="42" pco.reg.ref="S15_0322" publication.date="2024-04-26" enabling.title="Plumbing and Drainage Act 2018" enabling.acts="act-2018-017" sub.leg.type="reg" amending="none" print.type="reprint" first.valid.date="2024-04-26T00:00:00+10:00" in.force="allinforce" published.how="website" stage.repeal="1" stage.repeal.original.date="2029-09-01T00:00:00+10:00" repealed.by="stagerepeal" repealing.id="act-1992-022" initial.admin.dept="Department of Housing and Public Works" id="sl-2019-0042" version.desc.id="e96c0702-177c-4f68-bbcb-992863bb8923" version.series.id="71c1b55c-f1fc-4cf5-bb7a-40f09b17ecc9" end.valid.date="2025-01-02"><coverdata id="cd" guid="_112de4cd-be4a-45d8-96a6-2604301a229c"><subtitle id="cd-sut" guid="_61db284c-0bd3-4dad-8058-c450d345175e">Plumbing and Drainage Act 2018</subtitle></coverdata><wrapper><front id="frnt" guid="_f68d6c6f-e064-406d-87cd-e7a3c0447e24"><shorttitle id="frnt-st" guid="_5e99534a-636e-401e-a241-8b9be66ebd3d">Plumbing and Drainage Regulation 2019</shorttitle></front><body numbering.style="manual"><part id="pt.1" guid="_b0e00864-20c2-40a6-b724-7fa9e4736c38" affected.by.uncommenced="0"><no>Part 1</no><heading id="pt.1-he" guid="_ce2b8820-0dd1-4301-8d80-2452062aa676">Preliminary</heading><division id="pt.1-div.1" guid="_17586b92-3da9-4237-9a16-eed6626ece44" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.1-div.1-he" guid="_82e7df24-655e-4d64-b1aa-3914d1234b65">Introduction</heading><clause id="sec.1" guid="_af03ec40-241b-4d38-8239-482873acf685" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>1</no><heading id="sec.1-he" guid="_1957a322-0f39-44d0-ae41-234b13fa140f">Short title</heading><block><txt break.before="1">This regulation may be cited as the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2019-0042" target.version.series="71c1b55c-f1fc-4cf5-bb7a-40f09b17ecc9" check="valid"><name emphasis="yes">Plumbing and Drainage Regulation 2019</name></legref>.</txt></block></clause><clause id="sec.2" guid="_ecf2f858-d32b-416f-9f60-e6820e1196e6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>2</no><heading id="sec.2-he" guid="_c9ab6bcb-7e5c-4a0c-8a81-b55c1bd59f17">Commencement</heading><block><txt break.before="1">This regulation commences on the commencement of <legref jurisd="QLD" type="act" refid="sec.157" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_7061f5ac-9bbb-4687-8bf8-7efba78adafa" check="valid">section&#160;157</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>.</txt></block></clause></division><division id="pt.1-div.2" guid="_708f575b-40bd-4a2d-b0c5-a1ad745808d4" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.1-div.2-he" guid="_460e9ab5-b783-44c8-a2fa-d88277bfbf13">Interpretation</heading><clause id="sec.3" guid="_f6aaa0d6-b9e7-4d5c-8e75-8e77124d3c46" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>3</no><heading id="sec.3-he" guid="_ae404313-7c02-4142-807d-37c6efb066f9">Definitions</heading><block><txt break.before="1">The dictionary in <intref refid="sch.10" target.guid="_9b14f044-16d4-406a-a5ef-01515b4b359f" check="valid">schedule&#160;10</intref> defines particular words used in this regulation.</txt></block></clause><clause id="sec.4" guid="_2859e241-8023-4ec4-a7ae-2108a6af12bb" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4</no><heading id="sec.4-he" guid="_ad64b4d1-27b6-4cab-8e43-9e0bcdeeaecd">Permit work</heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.6" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_5aaef8f5-0881-4d4b-a288-ed19450908a9" check="valid">section&#160;6</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, permit work is plumbing or drainage work that is not—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.4-para1.a" guid="_4362a64b-b288-4fd0-9139-a8fe71c7de05" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">notifiable work; or</txt></block></li><li id="sec.4-para1.b" guid="_41582c7a-fd98-488f-9696-c0f97d4b74cd" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">minor work; or</txt></block></li><li id="sec.4-para1.c" guid="_6033f365-54a6-48d8-8128-6809fab0f0b0" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">unregulated work.</txt></block></li></list></block></clause><clause id="sec.5" guid="_7cf752a0-af01-4d7b-844d-d2760780bad9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>5</no><heading id="sec.5-he" guid="_d0cbfbd4-5834-4f23-bf2b-ccaae33b5f53">Notifiable work</heading><subclause id="sec.5-ssec.1" guid="_8a102a50-f305-42b6-84fe-e6b49ccde6c3" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.6" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_5aaef8f5-0881-4d4b-a288-ed19450908a9" check="valid">section&#160;6</legref><legref jurisd="QLD" type="act" check="invalid">(3)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, notifiable work is plumbing or drainage work of the type stated in <intref refid="sch.1" target.guid="_403e71c5-3ea2-4acb-b879-b60f7efbc877" check="valid">schedule&#160;1</intref>, <intref refid="sch.1-pt.2" target.guid="_805e0b7f-1871-4d8d-97f0-db43ebb0a8b5" check="valid">part&#160;2</intref>.</txt></block></subclause><subclause id="sec.5-ssec.2" guid="_9c3a61d1-cf9a-48c9-9ae4-f2e6327767c1" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">However, notifiable work does not include plumbing or drainage work to which <intref refid="sch.1" target.guid="_403e71c5-3ea2-4acb-b879-b60f7efbc877" check="valid">schedule&#160;1</intref>, <intref refid="sch.1-pt.1" target.guid="_546e76c5-9f7b-4817-a214-e1b2afbb7759" check="valid">part&#160;1</intref> applies.</txt></block></subclause></clause><clause id="sec.6" guid="_a4b6c655-842c-4f10-b894-79f9597f38f3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6</no><heading id="sec.6-he" guid="_7d242af9-14ed-4595-9f5d-aa072af6de52">Minor work</heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.6" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_5aaef8f5-0881-4d4b-a288-ed19450908a9" check="valid">section&#160;6</legref><legref jurisd="QLD" type="act" check="invalid">(4)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, minor work is plumbing or drainage work of the type stated in <intref refid="sch.2" target.guid="_1851c5c7-51bd-4868-9869-ebff429467c4" check="valid">schedule&#160;2</intref>.</txt></block></clause><clause id="sec.7" guid="_da74f108-496a-4163-a069-aa7cf873b1e5" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>7</no><heading id="sec.7-he" guid="_3067e55b-9020-4825-a8ec-1a8e5f0b39a3">Unregulated work</heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.6" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_5aaef8f5-0881-4d4b-a288-ed19450908a9" check="valid">section&#160;6</legref><legref jurisd="QLD" type="act" check="invalid">(5)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, unregulated work is plumbing or drainage work of the type stated in <intref refid="sch.3" target.guid="_bccfa414-fa42-4597-b13a-126231ca719d" check="valid">schedule&#160;3</intref>.</txt></block></clause></division></part><part id="pt.2" guid="_058799b3-38b1-47e0-8209-88b3d917626d" affected.by.uncommenced="0"><no>Part 2</no><heading id="pt.2-he" guid="_44072bf1-65b8-4272-a6a0-9cf06b377ca7">Codes and code requirements</heading><clause id="sec.8" guid="_38a5e7eb-d334-49ad-b8d5-43d2fed924c4" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>8</no><heading id="sec.8-he" guid="_e7817262-188f-4416-8ddb-2390cf65a4ac">Approval of Queensland Plumbing and Wastewater Code—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.7" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_5e4f550c-fb7c-4d53-b031-52a8566c59a7" check="valid">s&#160;7</legref></heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.7" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_5e4f550c-fb7c-4d53-b031-52a8566c59a7" check="valid">section&#160;7</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the Queensland Plumbing and Wastewater Code, version 1, 2024 is approved.</txt><note id="sec.8-note" guid="_c8943abf-6076-416e-aa6e-e123c533144d" type="example"><heading id="sec.8-note-he" guid="_b4f06919-18f7-4d5e-bfa3-88985ee7524d">Note—</heading><block><txt break.before="1">See, however, <intref refid="sec.34" target.guid="_20f9b59e-6903-41ec-97f6-121c1a95f82d" check="valid">section&#160;34</intref> in relation to a transitional treatment plant approval under <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, <intref refid="pt.4-div.5" target.guid="_8c3941f9-e162-435d-a282-e385d9d9ad88" check="valid">division&#160;5</intref>.</txt></block></note></block><historynote><txt break.before="1"><b>s&#160;8</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.3" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_e95592c6-813a-4a81-bcad-3378bb84916d" valid.date="as.made" check="valid">s&#160;3</legref></txt></historynote></clause><clause id="sec.9" guid="_d671ec88-a0a0-4777-aa5b-5437b63fa5df" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>9</no><heading id="sec.9-he" guid="_729f9278-62e4-4b19-826d-5bd3ff025387">Prescribed provisions of Plumbing Code of Australia—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">s&#160;9</legref></heading><subclause id="sec.9-ssec" guid="_6d6618b2-9e35-42b8-88f4-e3b4fb182331" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">section&#160;9</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref><legref jurisd="QLD" type="act" check="invalid">(b)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, each of the following provisions of the Plumbing Code of Australia (a <defterm id="sec.9-def.prescribedPCAprovision" guid="_932f7825-88f8-4fca-bf6a-9bd0a6e3282f" type="definition">prescribed PCA provision</defterm>) is prescribed—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.9-ssec-para1" guid="_576ef285-b700-4d7f-ba97-c1ff39237e7b" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">section A</txt></block></li><li id="sec.9-ssec-para1-oc.2" guid="_902a074f-1d41-4250-aec1-42a5eb4d4641" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">section B, other than part B4</txt></block></li><li id="sec.9-ssec-para1-oc.3" guid="_dd42d4ec-d338-4bc7-af9c-6cd383ded429" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">section C</txt></block></li><li id="sec.9-ssec-para1-oc.4" guid="_e6dccebe-8d97-4bc2-bcff-f290607387fe" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">section D</txt></block></li><li id="sec.9-ssec-para1-oc.5" guid="_88eb21ab-c1d3-44e1-b039-5ff7419f589c" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">section E</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;9</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.3" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_159a51fd-a112-40bb-b2fc-238311a871d3" valid.date="as.made" check="valid">s&#160;3</legref></txt></historynote></clause><clause id="sec.10" guid="_e9939668-123e-45c0-bc04-047756ff1bcd" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>10</no><heading id="sec.10-he" guid="_514aa91f-cf7d-4a57-8983-e4884b3703ba">Prescribed parts of Queensland Development Code—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">s&#160;9</legref></heading><subclause id="sec.10-ssec" guid="_fc606285-010a-4a4e-bc80-dc9c939e5f57" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">section&#160;9</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref><legref jurisd="QLD" type="act" check="invalid">(c)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, each of the following parts of the Queensland Development Code (a <defterm id="sec.10-def.prescribedQDCpart" guid="_931e8708-943f-4938-ad0b-f89d57c021d6" type="definition">prescribed QDC part</defterm>) is prescribed—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.10-ssec-para1" guid="_2bc2eb54-f238-4cc2-8be9-38de68047e03" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">MP 3.5—Construction of buildings in flood hazard areas</txt></block></li><li id="sec.10-ssec-para1-oc.2" guid="_cb76e5ef-2d8d-4a1e-94ea-aa95a5c2cd1a" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">MP 4.1—Sustainable buildings</txt></block></li><li id="sec.10-ssec-para1-oc.3" guid="_a8ecb8b0-a9c2-4b31-aa5d-684260bc6172" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">MP 4.2—Rainwater tanks and other supplementary water supply systems</txt></block></li><li id="sec.10-ssec-para1-oc.4" guid="_4828c7a6-4e8a-4edf-af2e-87900e5c8fb2" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">MP 4.3—Supplementary water sources—commercial buildings.</txt></block></li></list></block></subclause></clause><clause id="sec.11" guid="_2f3882b1-0c05-486a-8d9b-95ee01797875" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>11</no><heading id="sec.11-he" guid="_7e9bd528-9714-448a-acbb-8c3433e38ae0">Complying with Queensland Plumbing and Wastewater Code and prescribed PCA provision—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">s&#160;9</legref></heading><subclause id="sec.11-ssec.1" guid="_8b17a71b-bf00-4517-b585-77a3c97b6c09" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">section&#160;9</legref><legref jurisd="QLD" type="act" check="invalid">(4)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, plumbing or drainage work, or a plan for plumbing or drainage work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.11-ssec.1-para1.a" guid="_6032ca75-b74c-4a5e-9b77-a8de07282191" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">complies with the Queensland Plumbing and Wastewater Code only if the work complies with all relevant performance requirements for the work under the code; and</txt></block></li><li id="sec.11-ssec.1-para1.b" guid="_8a41318b-72b2-44fe-be48-24d70371eee8" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">complies with a prescribed PCA provision only if the work complies with all relevant performance requirements for the work under the provision. </txt></block></li></list></block></subclause><subclause id="sec.11-ssec.2" guid="_6d8a523d-5ee6-4df8-9da4-2b7225a235f6" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Compliance of the work with a relevant performance requirement under the Queensland Plumbing and Wastewater Code or a prescribed PCA provision can be achieved by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.11-ssec.2-para1.a" guid="_3fd387b8-55cb-4b48-b50a-c7a4f032f493" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a deemed-to-satisfy solution for the performance requirement under the code or provision; or</txt></block></li><li id="sec.11-ssec.2-para1.b" guid="_61f37510-a5c9-4254-b641-dd0961f21b13" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a performance solution for the performance requirement under the code or provision; or</txt></block></li><li id="sec.11-ssec.2-para1.c" guid="_94e91f22-14ec-42a0-a3b6-657baeb99a15" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a combination of the solutions mentioned in <intref refid="sec.11-ssec.2-para1.a" target.guid="_3fd387b8-55cb-4b48-b50a-c7a4f032f493" check="valid">paragraphs&#160;(a)</intref> and <intref refid="sec.11-ssec.2-para1.b" target.guid="_61f37510-a5c9-4254-b641-dd0961f21b13" check="valid">(b)</intref>.</txt></block></li></list></block></subclause></clause><clause id="sec.12" guid="_aaf56b2e-fa2b-4f07-b53f-40781d3dbe8f" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>12</no><heading id="sec.12-he" guid="_fdfadc19-e4f9-438b-b1bc-4a4a698352a0">Complying with prescribed QDC part—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">s&#160;9</legref></heading><subclause id="sec.12-ssec.1" guid="_021412e1-4097-4a35-af47-4c8a7cb662ff" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.9" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_c4f3f10c-5829-4145-9e3a-5a2da1949d25" check="valid">section&#160;9</legref><legref jurisd="QLD" type="act" check="invalid">(4)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, plumbing or drainage work, or a plan for plumbing or drainage work, complies with a prescribed QDC part only if the work complies with all relevant performance requirements for the work under the part.</txt></block></subclause><subclause id="sec.12-ssec.2" guid="_0f2b39f0-83c9-4317-85e9-f84e8ef1b77f" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Compliance of the work with a relevant performance requirement under a prescribed QDC part can be achieved only in the same way that compliance of building work with the relevant performance requirement can be achieved under the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref>, <legref jurisd="QLD" type="act" refid="sec.14" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" target.guid="_cc9c4e65-22c5-4dad-a7ba-cf596a46abcf" check="valid">section&#160;14</legref>.</txt></block></subclause></clause></part><part id="pt.3" guid="_0e845977-98f0-4102-b849-99ee17c13016" affected.by.uncommenced="0"><no>Part 3</no><heading id="pt.3-he" guid="_48f3d87b-4a3e-4df2-ba5e-e95b5f91a9d2">Licences</heading><clause id="sec.13" guid="_4423fbcf-414a-4fc8-9231-3e65de44c9c3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>13</no><heading id="sec.13-he" guid="_f4041662-7fcd-41a0-8165-1b2fa07cd987">Scope of work for classes of licence—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.13" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_69ee30fd-1d94-471e-9234-9d612321f126" check="valid">s&#160;13</legref></heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.13" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_69ee30fd-1d94-471e-9234-9d612321f126" check="valid">section&#160;13</legref><legref jurisd="QLD" type="act" check="invalid">(5)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.13-para1.a" guid="_bdfbc9e9-49aa-4705-8b73-08864d0b6dfe" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the scope of work for a plumbers licence is the plumbing work mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.1" target.guid="_ec4a35b8-b3ed-46c2-8291-e88a0874fb15" check="valid">part&#160;1</intref>; and</txt></block></li><li id="sec.13-para1.b" guid="_a545967d-3642-40f3-a8ca-26250ec8eff0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the scope of work for a drainers licence is the drainage work mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.2" target.guid="_15c85d01-551c-43fb-a234-f44cb19a3241" check="valid">part&#160;2</intref>; and</txt></block></li><li id="sec.13-para1.c" guid="_3174388f-324d-49f9-a033-95d5594c13a0" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the scope of work for a restricted licence of a type mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, column 1 is the plumbing or drainage work mentioned opposite the type of licence in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, column 2 of the schedule.</txt></block></li></list></block></clause><clause id="sec.14" guid="_a1698b4d-ced3-4af8-b134-e83758d8bd8a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>14</no><heading id="sec.14-he" guid="_1ee2303f-0aa6-48f6-b2c7-aa38a7b49e9d">Assessing alternative qualification</heading><subclause id="sec.14-ssec.1" guid="_c90c767a-55c1-4a49-88c3-ab54405b3d42" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.1-para1.a" guid="_d7ed9c8f-48bd-4cbb-b634-3d5d825d1c9f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person applies, or tells the commissioner the person intends to apply, to the commissioner for a licence; and</txt></block></li><li id="sec.14-ssec.1-para1.b" guid="_3133598e-1524-49f1-9861-27083bf45157" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the person intends to rely on a qualification (an <defterm id="sec.14-ssec.1-def.alternativequalification" guid="_ab7dc7ae-11c0-4cd1-97ed-123abce9c4b2" type="definition">alternative qualification</defterm>) for the application that is not 1 of the qualifications (the <defterm id="sec.14-ssec.1-def.existingqualifications" guid="_c64cd295-25b7-479a-8bf9-f6bb2ae11be8" type="definition">existing qualifications</defterm>) for the licence decided by the commissioner under <legref jurisd="QLD" type="act" refid="sec.14" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_195c3dc1-9cc8-415f-b199-d32c6cadbfcf" check="valid">section&#160;14</legref><legref jurisd="QLD" type="act" check="invalid">(a)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>; and</txt></block></li><li id="sec.14-ssec.1-para1.c" guid="_14e82c39-f718-4cc0-a629-4e38d64649b3" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the commissioner considers it is, or will be, necessary to assess whether the alternative qualification is equivalent to any of the existing qualifications to decide whether the person has the qualifications required for the licence; and </txt></block></li><li id="sec.14-ssec.1-para1.d" guid="_37155c8d-60ca-46c8-bb5c-94006aecb23d" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the person asks the commissioner to assess the equivalence of the alternative qualification and pays QBCC the fee stated in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref> for the assessment.</txt></block></li></list></block></subclause><subclause id="sec.14-ssec.2" guid="_4d2ed63a-e1b7-40bd-afce-e542ea0fa9f4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The commissioner must assess whether the alternative qualification is equivalent to any of the existing qualifications.</txt></block></subclause><subclause id="sec.14-ssec.3" guid="_f2db52bf-b52c-4dbc-b0c5-cfb2d2610da9" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0"><intref refid="sec.14-ssec.4" target.guid="_89ba5d00-bb5a-42c8-b940-9c116eeac4f9" check="valid">Subsection&#160;(4)</intref> applies if the commissioner considers the only practicable way to assess the equivalence of the alternative qualification under <intref refid="sec.14-ssec.2" target.guid="_4d2ed63a-e1b7-40bd-afce-e542ea0fa9f4" check="valid">subsection&#160;(2)</intref> is to have the person’s competencies for the alternative qualification assessed by a registered training organisation.</txt></block></subclause><subclause id="sec.14-ssec.4" guid="_89ba5d00-bb5a-42c8-b940-9c116eeac4f9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The commissioner may refer the person to a registered training organisation to— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.4-para1.a" guid="_0fde6c6c-6e5e-48da-b543-baef29778c80" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">carry out an assessment of the competencies for the alternative qualification; and</txt></block></li><li id="sec.14-ssec.4-para1.b" guid="_3980956d-aa89-4522-8411-fae946cb51e8" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">advise the commissioner of the results of its assessment.</txt></block></li></list></block></subclause><subclause id="sec.14-ssec.5" guid="_086b3c74-ad9e-46af-a6ae-cc4617da4b12" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">To remove any doubt, it is declared that the requirement for the person to pay the prescribed fee under <intref refid="sec.14-ssec.1" target.guid="_c90c767a-55c1-4a49-88c3-ab54405b3d42" check="valid">subsection&#160;(1)</intref><intref refid="sec.14-ssec.1-para1.d" target.guid="_37155c8d-60ca-46c8-bb5c-94006aecb23d" check="valid">(d)</intref> for the commissioner’s assessment under <intref refid="sec.14-ssec.2" target.guid="_4d2ed63a-e1b7-40bd-afce-e542ea0fa9f4" check="valid">subsection&#160;(2)</intref> does not prevent or restrict a registered training organisation from charging the person an additional fee for supplying a service under <intref refid="sec.14-ssec.4" target.guid="_89ba5d00-bb5a-42c8-b940-9c116eeac4f9" check="valid">subsection&#160;(4)</intref>.</txt></block></subclause><subclause id="sec.14-ssec.6" guid="_57872495-9735-4643-8800-413ec0b68b2f" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.14-ssec.6-def.competencies_" guid="_8d325761-4a79-4c1f-a57b-e4575e12696a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.14-ssec.6-def.competencies" guid="_b7cb2401-632f-4f8f-b8c0-a256f6ecd05a" type="definition">competencies</defterm>, for a qualification, means the units of competency (however called) that satisfied the requirements of the qualification.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;14</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0119" target.version.series="709734de-1f83-42dc-a78e-2618c91fc926" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;119</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2020-0119" target.version.series="709734de-1f83-42dc-a78e-2618c91fc926" target.guid="_d1776a31-8c7f-4bd8-ab44-d9861813d246" valid.date="as.made" check="valid">s&#160;11</legref></txt></historynote></clause><clause id="sec.15" guid="_77078d94-034f-4969-be0b-7ef068d6df50" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>15</no><heading id="sec.15-he" guid="_25b4d156-bbe8-45fb-9722-5a31fe8d7edb">Scope of work for particular endorsements—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.25" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_47ab03ce-913e-4375-a785-238440fb136a" check="valid">s&#160;25</legref></heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.25" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_47ab03ce-913e-4375-a785-238440fb136a" check="valid">section&#160;25</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.15-para1.a" guid="_ad60a349-02c3-4868-aead-4c98e54864aa" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the scope of work for an endorsement on a plumbers licence or provisional plumbers licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.4" target.guid="_92dd9f1e-b114-4b81-bfb9-0cd44e9c6937" check="valid">part&#160;4</intref>, column 1 is the plumbing work mentioned opposite the endorsement in <intref refid="sch.4-pt.4" target.guid="_92dd9f1e-b114-4b81-bfb9-0cd44e9c6937" check="valid">part&#160;4</intref>, column 2 of the schedule; and</txt></block></li><li id="sec.15-para1.b" guid="_357b8d1d-0425-42db-92b6-839ac8f7244f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the scope of work for an endorsement on a drainers licence or provisional drainers licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.5" target.guid="_beace490-6959-45b9-ac1c-0f6140330636" check="valid">part&#160;5</intref>, column 1 is the drainage work mentioned opposite the endorsement in <intref refid="sch.4-pt.5" target.guid="_beace490-6959-45b9-ac1c-0f6140330636" check="valid">part&#160;5</intref>, column 2 of the schedule.</txt></block></li></list></block></clause></part><part id="pt.4" guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" affected.by.uncommenced="0"><no>Part 4</no><heading id="pt.4-he" guid="_751142d5-3b97-4f71-94a6-34d6adedef42">Treatment plant approvals and related matters</heading><division id="pt.4-div.1" guid="_4bfcbd21-e508-4dd0-995b-c75967905f81" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.4-div.1-he" guid="_ce2e5e7b-fe5f-415d-86eb-2ceb0737cbc1">Applications</heading><clause id="sec.16" guid="_db274771-cdf5-47c5-a844-cef833ef5a69" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>16</no><heading id="sec.16-he" guid="_c06f20b1-0d0c-48ff-8e76-73be7dc7eaa9">Applying for, or to amend, treatment plant approval</heading><subclause id="sec.16-ssec.1" guid="_1cd3914d-914e-4eac-a6b9-9b2fe03321cb" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A person may apply to the chief executive for a treatment plant approval for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.1-para1.a" guid="_6d242636-fe8a-4fd4-a33f-9e3f0773277c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a greywater treatment plant of a particular type, other than a greywater (cooling tower) treatment plant; or</txt></block></li><li id="sec.16-ssec.1-para1.b" guid="_c79bae1b-542c-4b48-aaa7-85bd2376b563" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a secondary on-site sewage treatment plant of a particular type.</txt></block></li></list></block></subclause><subclause id="sec.16-ssec.2" guid="_5910e17e-3b12-4bac-b288-719f6ef38e23" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The holder of a treatment plant approval may apply to the chief executive to amend the approval.</txt></block></subclause><subclause id="sec.16-ssec.3" guid="_5f4522f2-e730-4b50-8285-263c2aca5ba7" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The application must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.3-para1.a" guid="_bd7ba9fc-7960-4171-8ba3-53f654029eab" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">be in the approved form; and</txt></block></li><li id="sec.16-ssec.3-para1.b" guid="_4033d7ac-0b27-4395-97eb-36f76e9920c8" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">be accompanied by the documents as required under <intref refid="sch.5" target.guid="_7204e1f3-ae25-4d77-bd0c-99472b11c830" check="valid">schedule&#160;5</intref>.</txt></block></li></list></block></subclause><subclause id="sec.16-ssec.4" guid="_4b7c9013-cd5b-498f-b580-b3d02f94f0c5" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">However, an application to amend a treatment plant approval is not required to be accompanied by a document if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.4-para1.a" guid="_7d2021a3-99fe-4e6c-b093-79016c943b79" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the document accompanied the application for the approval or a previous application to amend the approval; and </txt></block></li><li id="sec.16-ssec.4-para1.b" guid="_6f1b7842-6a2a-46c8-8c6d-1ee28d80e087" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">there has been no change to any material particular in the information contained in the document.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;16</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_adc8a223-f14f-41d5-885b-f8089c28d038" valid.date="as.made" check="valid">s&#160;4</legref></txt></historynote></clause><clause id="sec.17" guid="_613ee53f-70b5-4d5a-adab-7188c80824b0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>17</no><heading id="sec.17-he" guid="_c5f27d20-8ba3-4d58-af18-551a4f986dfc">Requesting further information</heading><subclause id="sec.17-ssec.1" guid="_3a93d993-828e-4a8f-a136-8696af7de7c2" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The chief executive may, by notice given to the applicant, ask the applicant for further information the chief executive needs to decide the application.</txt></block></subclause><subclause id="sec.17-ssec.2" guid="_495b7eb9-32a7-4cbb-986f-5a49908526d9" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The notice must be given to the applicant within 10 business days after the application is made. <b/></txt></block></subclause><subclause id="sec.17-ssec.3" guid="_a074c7c3-451d-40db-8d17-bd30f70ac72a" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the chief executive asks for information under <intref refid="sec.17-ssec.2" target.guid="_495b7eb9-32a7-4cbb-986f-5a49908526d9" check="valid">subsection&#160;(2)</intref>, the chief executive need not deal with the application until the applicant gives the information to the chief executive.</txt></block></subclause><subclause id="sec.17-ssec.4" guid="_3fbd2e5b-2088-499a-85e4-57e6cc163f7f" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the applicant does not give the information to the chief executive within 6 months after the application is made, the chief executive may treat the application as having lapsed. </txt></block></subclause></clause><clause id="sec.18" guid="_6f2ac50a-ebe8-43c0-a3eb-5346aec18df0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>18</no><heading id="sec.18-he" guid="_f7a5737e-5574-4889-8f9b-1710539881cd">Deciding application</heading><subclause id="sec.18-ssec" guid="_6300d6b6-9957-4d87-b016-018a41cfd132" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">The chief executive must consider the application and decide to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.18-ssec-para1.a" guid="_cbe6da68-482f-4eef-bafa-c293297815f4" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">approve the application with any conditions the chief executive considers reasonable and relevant or without conditions; or</txt><note id="sec.18-ssec-para1.a-note" guid="_5bee4e59-44ed-4924-b6c9-e1e6aa3b4e65" type="example"><heading id="sec.18-ssec-para1.a-note-he" guid="_e3e838c3-7ced-4469-b2db-d2cf2e91597b">Examples of conditions—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.18-ssec-para1.a-note-para2" guid="_3fe22187-c4a8-4ec7-8e60-569966f648f2" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a condition of a treatment plant testing approval about when, and how, the contents of a treatment plant must be disposed of </txt></block></li><li id="sec.18-ssec-para1.a-note-para2-oc.2" guid="_27a9ed8b-21c7-4ba2-9fa5-16f2458cdbc9" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a condition of a treatment plant use approval that a treatment plant must be supplied with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.18-ssec-para1.a-note-para2-oc.2-para3.a" guid="_2924fbf7-7cc1-40d1-95a3-8809f0928197" provision.type="other" affected.by.uncommenced="0"><no> (a)</no><block><txt break.before="0">evidence of the treatment plant approval; and</txt></block></li><li id="sec.18-ssec-para1.a-note-para2-oc.2-para3.b" guid="_8e18aa56-4f11-4858-ac16-32d86be934b2" provision.type="other" affected.by.uncommenced="0"><no> (b)</no><block><txt break.before="0">details of the model of the treatment plant; and</txt></block></li><li id="sec.18-ssec-para1.a-note-para2-oc.2-para3.c" guid="_7c540d6c-235f-4ef1-9a35-5bd48b755273" provision.type="other" affected.by.uncommenced="0"><no> (c)</no><block><txt break.before="0">instructions for the manufacture, installation, operation, or maintenance of the treatment plant</txt></block></li></list></block></li></list></block></note></block></li><li id="sec.18-ssec-para1.b" guid="_e6cd1b10-0edc-4232-9d0a-6b68a259678c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">refuse the application.</txt></block></li></list></block></subclause></clause><clause id="sec.19" guid="_b763e4d7-ba16-4a6a-b154-a066d5c02f7c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>19</no><heading id="sec.19-he" guid="_db819653-2feb-4655-b4ae-f70305e06acb">Criteria for decision</heading><subclause id="sec.19-ssec" guid="_f9144006-4c82-45ef-9cf0-ea16bed3b2b8" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">The chief executive may decide to approve the application if satisfied—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec-para1.a" guid="_52bc84fa-acc0-4f4e-8a47-8b3766560539" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for an application relating to a grey water treatment plant of a particular type, a treatment plant of that type complies with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec-para1.a-para2.i" guid="_bc09eff1-72c1-4285-a3d7-c9e01033c4a8" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the Queensland Plumbing and Wastewater Code, <intref refid="sch.1" target.guid="_403e71c5-3ea2-4acb-b879-b60f7efbc877" check="valid">schedule&#160;1</intref>; and</txt></block></li><li id="sec.19-ssec-para1.a-para2.ii" guid="_09b66a38-ae3b-43e9-a0d0-c34915a811da" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the conformity assessment requirements; or</txt></block></li></list></block></li><li id="sec.19-ssec-para1.b" guid="_00602cfc-1abd-4313-b2e3-24ba9fe0b50f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for an application relating to a secondary on-site sewage treatment plant of a particular type, a treatment plant of that type—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec-para1.b-para2.i" guid="_1e451170-2520-4448-aafa-6e79fc4ba8fa" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">is capable of treating no more than 4.2kL of sewage in a day; and</txt></block></li><li id="sec.19-ssec-para1.b-para2.ii" guid="_4bec4bb3-f5d4-4962-a987-e888171422d6" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">complies with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec-para1.b-para2.ii-para3.A" guid="_ac24718e-c22b-4627-a15f-5f889e92bf93" provision.type="other" affected.by.uncommenced="0"><no>(A)</no><block><txt break.before="0"> AS 1546.3:2017; and</txt></block></li><li id="sec.19-ssec-para1.b-para2.ii-para3.B" guid="_6a359483-2011-4e15-b225-1fd74e9420f3" provision.type="other" affected.by.uncommenced="0"><no>(B)</no><block><txt break.before="0">the conformity assessment requirements.</txt></block></li></list></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;19</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_36aa09c9-6ad1-4b94-852b-fc2fb9df94d7" valid.date="as.made" check="valid">s&#160;4</legref></txt></historynote></clause><clause id="sec.20" guid="_d80d7d5e-1333-4750-926e-1fb439a284ab" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>20</no><heading id="sec.20-he" guid="_90ed7609-337d-4504-b5d3-a28105f9b967">Granting or amending treatment plant approval</heading><block><txt break.before="1">If the chief executive decides to approve the application, the chief executive must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.20-para1.a" guid="_71be32a6-bfe4-4640-b0ff-cf91b33044a6" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">give the treatment plant approval, or amended approval, to the applicant; and</txt></block></li><li id="sec.20-para1.b" guid="_66459b6f-6264-4b08-8cd3-3f2714ecdf22" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">publish a copy of the approval, or amended approval, on the department’s website; and</txt></block></li><li id="sec.20-para1.c" guid="_5dc61c6b-5305-47bd-9265-494fffab60d9" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for an amended approval, ensure the published copy includes a statement that the approval was amended on a stated day. </txt></block></li></list></block></clause><clause id="sec.21" guid="_44e5c9a5-c895-423a-ab55-4f4ee941366b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>21</no><heading id="sec.21-he" guid="_dce5c62a-2d8a-4774-a407-2b889a5e344c">Failure to decide application</heading><subclause id="sec.21-ssec.1" guid="_62e87bff-a48c-4f56-935c-4c1ac9193bf2" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the chief executive does not decide the application within the required period after receiving— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.21-ssec.1-para1.a" guid="_8fe0419b-4fc0-4c10-a606-fcc1a9b86c22" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the application; or </txt></block></li><li id="sec.21-ssec.1-para1.b" guid="_630619d1-1e85-4388-9617-fc8b7f6e33e9" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the chief executive asks for further information under <intref refid="sec.17" target.guid="_613ee53f-70b5-4d5a-adab-7188c80824b0" check="valid">section&#160;17</intref>—the information.</txt></block></li></list></block></subclause><subclause id="sec.21-ssec.2" guid="_0ef6ebe6-9060-4e91-9b43-4c0a41995a3f" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The chief executive is taken to have decided to refuse the application.</txt></block></subclause><subclause id="sec.21-ssec.3" guid="_dec0d2ea-cc60-4d2d-bd9a-fd6690d257fd" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.21-ssec.3-def.requiredperiod_" guid="_e33e43a7-9de9-4892-979a-197116ee2f57" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.21-ssec.3-def.requiredperiod" guid="_857257df-6de9-42f0-8d58-90ac1b350dfb" type="definition">required period</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.21-ssec.3-def.requiredperiod-para1.a" guid="_dc0a0787-ccc8-46d2-a3c6-897a8be9a9e3" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">10 business days; or</txt></block></li><li id="sec.21-ssec.3-def.requiredperiod-para1.b" guid="_e6660a33-400d-42cd-8ddd-86323542eed3" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if a longer period is agreed between the chief executive and the applicant—the longer period.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.22" guid="_606b2d28-34f8-4227-bb94-bc8a5af17e3b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>22</no><heading id="sec.22-he" guid="_0504cadc-1ade-49e0-9d0d-4ccd3e45defa">Information notice about decisions</heading><subclause id="sec.22-ssec.1" guid="_e279a1df-8c60-45b4-8d21-f5d60b64eef2" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0"><intref refid="sec.22-ssec.2" target.guid="_370d4354-9910-4aba-9d7f-71d6940dfe02" check="valid">Subsection&#160;(2)</intref> applies if the chief executive decides to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.1-para1.a" guid="_23d960f0-7586-429f-8828-0399d93e97a5" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">approve the application and grant, or amend, the treatment plant approval with a condition; or</txt></block></li><li id="sec.22-ssec.1-para1.b" guid="_c2ae77a8-3a0f-4971-803d-81a66a82e224" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">refuse the application.</txt></block></li></list></block></subclause><subclause id="sec.22-ssec.2" guid="_370d4354-9910-4aba-9d7f-71d6940dfe02" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The chief executive must give the applicant an information notice about the decision.</txt></block></subclause><subclause id="sec.22-ssec.3" guid="_572e5938-0a11-4fc1-ad56-4718b79abb75" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If, under <intref refid="sec.21" target.guid="_44e5c9a5-c895-423a-ab55-4f4ee941366b" check="valid">section&#160;21</intref>, the chief executive is taken to have decided to refuse the application, the applicant is entitled to be given an information notice about the decision.</txt><note id="sec.22-ssec.3-note" guid="_3017b60d-aece-46fc-98e2-cff9519431cb" type="example"><heading id="sec.22-ssec.3-note-he" guid="_71e913f9-3d9b-4f99-800f-a8cc7ed853f6">Note—</heading><block><txt break.before="1">For an appeal against a decision mentioned in <intref refid="sec.22-ssec.1" target.guid="_e279a1df-8c60-45b4-8d21-f5d60b64eef2" check="valid">subsection&#160;(1)</intref> or <intref refid="sec.22-ssec.3" target.guid="_572e5938-0a11-4fc1-ad56-4718b79abb75" check="valid">(3)</intref>, see the <legref jurisd="QLD" type="act" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" check="valid"><name emphasis="yes">Planning Act 2016</name></legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_b27e6fb3-817d-489b-ba9f-f87df89be113" check="valid">schedule&#160;1</legref>, <legref jurisd="QLD" type="act" refid="sch.1-sec.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_e79cbd63-ba5c-415b-bc7d-9217dd599138" check="valid">section&#160;1</legref>, table 3, items 3 and 5.</txt></block></note></block></subclause></clause></division><division id="pt.4-div.2" guid="_01081ffd-d818-4b76-b6f0-9c2426e4e9cb" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.4-div.2-he" guid="_0e319182-741b-4577-b440-dc86a87f472e">Duration and transfer of approvals</heading><clause id="sec.23" guid="_93758392-1aad-4c09-a9bb-48e29972c18c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>23</no><heading id="sec.23-he" guid="_eaa2c2a4-ba77-458c-b2ae-2b847f2781ae">Duration of approval</heading><block><txt break.before="0">A treatment plant approval remains in force for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23-para1.a" guid="_d9ceadc1-dc3f-4091-a6a1-4f58edb52925" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the period stated in the approval; or</txt></block></li><li id="sec.23-para1.b" guid="_59882043-0840-4ea8-bdbe-0474c9273020" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if no period is stated in the approval—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23-para1.b-para2.i" guid="_68e21d5d-dd34-4088-a4c5-35039f9d954d" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">for a treatment plant testing approval—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23-para1.b-para2.i-para3.A" guid="_07f89169-d6d5-4930-9d7f-3f9c83acf47b" provision.type="other" affected.by.uncommenced="0"><no>(A)</no><block><txt break.before="0">1 year after the approval is given; or </txt></block></li><li id="sec.23-para1.b-para2.i-para3.B" guid="_ca13471d-a137-4692-baff-ab7681e083a5" provision.type="other" affected.by.uncommenced="0"><no>(B)</no><block><txt break.before="0">if, before that year ends, the chief executive agrees in writing to a longer period—the longer period; or </txt></block></li></list></block></li><li id="sec.23-para1.b-para2.ii" guid="_821846ac-f962-4656-ae5e-0b206c3b482e" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">for a treatment plant use approval—5 years after the approval is given.</txt></block></li></list></block></li></list></block><note id="sec.23-note" guid="_bbd6293c-2e79-4832-a069-e6f9ad8c9deb" type="example"><heading id="sec.23-note-he" guid="_c3dc0ca5-e499-44b4-8014-ff7ee0c97df0">Note—</heading><block><txt break.before="1">For the duration of a transitional treatment plant approval under <intref refid="pt.4-div.5" target.guid="_8c3941f9-e162-435d-a282-e385d9d9ad88" check="valid">division&#160;5</intref>, see <intref refid="sec.35A" target.guid="_1b16a6b4-8602-40c3-9b3c-f6342320a328" check="valid">section&#160;35A</intref>.</txt></block></note><historynote><txt break.before="1"><b>s&#160;23</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_ebc9497c-5a52-43df-b802-3f6410c873bc" valid.date="as.made" check="valid">s&#160;5</legref></txt></historynote></clause><clause id="sec.24" guid="_9d87ecbf-26c1-47c5-b2bc-1b736254c7b5" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>24</no><heading id="sec.24-he" guid="_197954e2-d5a9-4113-b958-0f083a4cc890">Transferring approval</heading><subclause id="sec.24-ssec.1" guid="_7587b5c8-a0fb-4f08-b7b4-15c373824203" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the holder of a treatment plant approval proposes to transfer the approval to another person (the <defterm id="sec.24-def.newholder" guid="_a3a6e94e-d23f-4a3c-a416-966e78d66859" type="definition">new holder</defterm>).</txt></block></subclause><subclause id="sec.24-ssec.2" guid="_40bf7ecc-a5fc-42f2-86e5-9df70843f15e" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The new holder must give the chief executive notice of the transfer in the approved form.</txt></block></subclause><subclause id="sec.24-ssec.3" guid="_19ce225d-ccca-4af7-b037-0a4f3f567693" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The chief executive must, after being given the notice—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.24-ssec.3-para1.a" guid="_9cd4f7ec-57f5-4994-a95e-333c4aa7ebe3" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">record the new holder as the holder of the treatment plant approval; and</txt></block></li><li id="sec.24-ssec.3-para1.b" guid="_414ceb71-ea22-41ec-aab1-aa984f0323a0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">transfer the treatment plant approval by reissuing it to the new holder; and</txt></block></li><li id="sec.24-ssec.3-para1.c" guid="_cebc6a8d-d884-4ea0-a377-78ed18450865" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">publish, on the department’s website, a copy of the transferred approval including a statement that the approval was transferred on a stated day.</txt></block></li></list></block></subclause><subclause id="sec.24-ssec.4" guid="_6d485cf7-42a8-473d-aacb-d94726358bc8" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">A treatment plant approval may be transferred only under this section.</txt></block></subclause></clause></division><division id="pt.4-div.3" guid="_b971f1f5-fbda-4172-92e1-ae150317a83f" affected.by.uncommenced="0"><no>Division 3</no><heading id="pt.4-div.3-he" guid="_3b5286a4-386b-4962-aed1-dd8de6693ff0">Inspecting approved treatment plants</heading><clause id="sec.25" guid="_c18c6a3c-9890-476d-b852-161c0bd91a9f" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>25</no><heading id="sec.25-he" guid="_0fd8b1e7-3d7d-43a3-ad11-d1a8ec617cac">Application of division</heading><subclause id="sec.25-ssec" guid="_8af20b6c-9c54-426c-9324-ad2c144ad148" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">This division applies if the chief executive considers a matter may significantly adversely affect on-site sewage treatment plants of a type the subject of a treatment plant approval (each an <defterm id="sec.25-def.affectedtreatmentplant" guid="_0d77328a-47f0-49d5-89db-c09ccae9255b" type="definition">affected treatment plant</defterm>).</txt></block><note id="sec.25-ssec-note" guid="_3e2041be-85c6-476b-bf51-02c4d0125c8f" type="example"><heading id="sec.25-ssec-note-he" guid="_b9bd04ff-2908-4944-9977-1028a13aba9c">Example of a matter for this section—</heading><block><txt break.before="1">a systemic failure affecting, or potentially affecting, the functioning of a particular model of on-site sewage treatment plant</txt></block></note></subclause></clause><clause id="sec.26" guid="_f66ccd25-c07b-462c-8932-da75128d4df4" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>26</no><heading id="sec.26-he" guid="_3cf6bd94-777b-416a-bd03-8921d957917b">Notice to local government requiring information</heading><subclause id="sec.26-ssec.1" guid="_91cc393c-6304-4f31-a55d-85acd24c1ed8" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The chief executive may give a notice to a local government requiring the local government to give the chief executive the following information—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.26-ssec.1-para1.a" guid="_152ec513-d0c2-4c43-9d66-31cf415a5144" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the address of each premises in the local government area where an affected treatment plant has been installed;</txt></block></li><li id="sec.26-ssec.1-para1.b" guid="_52e6a39a-636d-4533-91ca-9742f863e130" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the name of the owner of the premises.</txt></block></li></list></block></subclause><subclause id="sec.26-ssec.2" guid="_1e34a9b2-4341-46f4-98a6-263cafa37915" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must comply with the notice.</txt></block></subclause></clause><clause id="sec.27" guid="_f7125df8-b82d-47ed-8d02-f28b13f2bd57" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>27</no><heading id="sec.27-he" guid="_d4425f14-f360-4781-a883-f28eca09023c">Notice requesting access to premises</heading><subclause id="sec.27-ssec" guid="_3187c48d-1fa2-4b1a-baff-0598eaddcaed" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">The chief executive may give a notice to the owner of premises where an affected treatment plant has been installed—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.27-ssec-para1.a" guid="_a536bdc6-48d0-4457-938f-a1c2f750c390" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">briefly stating the nature of the matter mentioned in <intref refid="sec.25" target.guid="_c18c6a3c-9890-476d-b852-161c0bd91a9f" check="valid">section&#160;25</intref>; and</txt></block></li><li id="sec.27-ssec-para1.b" guid="_9bac2c63-9ee8-4163-b39f-b16e93b698f1" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">stating that the chief executive has arranged for a person to inspect the treatment plant; and</txt></block></li><li id="sec.27-ssec-para1.c" guid="_c89f9369-8664-4f6d-8fcc-09fbc983ce24" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">asking for the owner’s consent for the person to enter the premises to carry out the inspection.</txt></block></li></list></block></subclause></clause></division><division id="pt.4-div.4" guid="_dd838be0-25e4-4c4d-9878-78441f918383" affected.by.uncommenced="0"><no>Division 4</no><heading id="pt.4-div.4-he" guid="_9b52222c-9c77-429f-ab15-624218dd84d0">Cancellation of approvals</heading><clause id="sec.28" guid="_ca7a628e-67bc-4fbb-af85-64814ae7a5e8" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>28</no><heading id="sec.28-he" guid="_913fc162-af94-4ed3-9e1d-87194f05a68c">Show cause notice for contravening condition of approval</heading><subclause id="sec.28-ssec.1" guid="_1567fd3d-8f77-470c-8a20-a023c285f143" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the chief executive reasonably believes the holder of a treatment plant approval has contravened a condition of the approval.</txt><note id="sec.28-ssec.1-note" guid="_f78dacf7-c0c7-4112-ba91-0bc766a0d122" type="example"><heading id="sec.28-ssec.1-note-he" guid="_29eeb7fe-86f7-40a3-8d47-3108c257cae6">Example for <intref refid="sec.28-ssec.1" target.guid="_1567fd3d-8f77-470c-8a20-a023c285f143" check="valid">subsection&#160;(1)</intref>—</heading><block><txt break.before="1">The chief executive may believe the holder of a treatment plant approval has manufactured treatment plants that do not conform with the product specification document on which the approval was based.</txt></block></note></block></subclause><subclause id="sec.28-ssec.2" guid="_46a6ec35-a46c-4c46-b6ff-6fad516135dd" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The chief executive must give the holder a notice under this section (a <defterm id="sec.28-def.showcausenotice" guid="_c30f5856-cd7b-4f4f-ae8e-bed38ee07524" type="definition">show cause notice</defterm>).</txt></block></subclause><subclause id="sec.28-ssec.3" guid="_56f4bf6e-4f73-4cd3-9fca-7758c16d5129" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The show cause notice must state—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.28-ssec.3-para1.a" guid="_b8c90997-8b0d-436b-b589-03520046fd5e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">that the chief executive proposes to cancel the treatment plant approval under this division; and</txt></block></li><li id="sec.28-ssec.3-para1.b" guid="_6273e27f-a16d-48f6-8f17-edaa88575442" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the grounds for the proposed cancellation; and</txt></block></li><li id="sec.28-ssec.3-para1.c" guid="_684b0ab1-9680-4a0d-9692-b2a4ae35e254" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">an outline of the facts and circumstances forming the basis for the grounds; and</txt></block></li><li id="sec.28-ssec.3-para1.d" guid="_81a43f21-421c-4f18-8587-03bc6beb3da1" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">that the holder may, within a stated period (the <defterm id="sec.28-ssec.3-def.showcauseperiod" guid="_525d62cc-f328-4120-90a3-cf97f2520680" type="definition">show cause period</defterm>), make representations about why the approval should not be cancelled.</txt></block></li></list></block></subclause><subclause id="sec.28-ssec.4" guid="_1e9081fb-f99d-4500-af4f-9de740a6a420" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The show cause period must end at least 20 business days after the holder is given the show cause notice.</txt></block></subclause></clause><clause id="sec.29" guid="_431125d0-b9fd-44d7-8377-a8282f3190bd" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>29</no><heading id="sec.29-he" guid="_8b094281-8aa1-4ffa-8132-31488484a58b">Representations about show cause notice</heading><subclause id="sec.29-ssec.1" guid="_8a1ef54d-dbb1-459c-b74f-894f7a32d629" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The holder of the treatment plant approval may make written representations about the show cause notice to the chief executive in the show cause period.</txt></block></subclause><subclause id="sec.29-ssec.2" guid="_7df99c55-fa4b-49f3-bde2-ecf2cf3f9f7c" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The chief executive must consider all representations (the <defterm id="sec.29-def.acceptedrepresentations" guid="_0613a475-8858-4d66-9e35-b891600f2459" type="definition">accepted representations</defterm>) made under <intref refid="sec.29-ssec.1" target.guid="_8a1ef54d-dbb1-459c-b74f-894f7a32d629" check="valid">subsection&#160;(1)</intref>.</txt></block></subclause></clause><clause id="sec.30" guid="_e75a90b4-6474-479b-860f-9f9f37d8bd69" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>30</no><heading id="sec.30-he" guid="_285866f6-5698-4730-b979-3b5d09fbc571">Ending show cause process without further action</heading><subclause id="sec.30-ssec.1" guid="_23e9a4e4-c8eb-4120-a045-bd3a48e81994" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if, after considering the accepted representations for the show cause notice, the chief executive no longer believes a ground exists to cancel the treatment plant approval.</txt></block></subclause><subclause id="sec.30-ssec.2" guid="_d582837c-cb38-4f1e-a360-f025ab4a800d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The chief executive must not take any further action in relation to the show cause notice.</txt></block></subclause><subclause id="sec.30-ssec.3" guid="_394ae18f-5f31-4c94-a6f0-bc04946865ce" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The chief executive must give the holder of the treatment plant approval notice that no further action is to be taken in relation to the show cause notice.</txt></block></subclause></clause><clause id="sec.31" guid="_39271762-c8ce-4b9d-b9c4-a6ebf555a3e4" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>31</no><heading id="sec.31-he" guid="_f3485bce-ea0a-4df8-b534-304f795eb592">Cancellation</heading><subclause id="sec.31-ssec.1" guid="_f6d45a61-2671-4e56-aad8-fe6182f7ba7d" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.31-ssec.1-para1.a" guid="_47ea9a05-4df1-4a20-b3d9-6d99d95af713" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">there are accepted representations for the show cause notice and, after considering the representations, the chief executive still believes a ground exists to cancel the treatment plant approval; or</txt></block></li><li id="sec.31-ssec.1-para1.b" guid="_bfc7a7d1-e6b1-4153-9899-a71fe5c30ddd" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">there are no accepted representations.</txt></block></li></list></block></subclause><subclause id="sec.31-ssec.2" guid="_81b7eba5-74f0-4c88-a9bc-b686288719ff" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the chief executive believes cancellation of the treatment plant approval is warranted, the chief executive may cancel the approval.</txt></block></subclause><subclause id="sec.31-ssec.3" guid="_6b1c2497-04f6-446a-8adb-0f9eb4212e05" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The chief executive must give the holder an information notice about the decision to cancel the approval.</txt></block></subclause><subclause id="sec.31-ssec.4" guid="_2490b3f5-68ba-4670-84c2-b1220c4a9151" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The decision takes effect on the later of the following days—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.31-ssec.4-para1.a" guid="_fe5911a3-6644-4954-b1aa-6a8aa1f08cbb" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the day the information notice is given to the holder;</txt></block></li><li id="sec.31-ssec.4-para1.b" guid="_ec207a4f-f8b1-4fc7-9431-0f6ba449c261" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the day stated in the information notice for that purpose.</txt></block></li></list></block></subclause></clause></division><division id="pt.4-div.5" guid="_8c3941f9-e162-435d-a282-e385d9d9ad88" affected.by.uncommenced="0"><no>Division 5</no><heading id="pt.4-div.5-he" guid="_8acdce65-73c2-4971-8a3f-b124ff823602">Particular provisions for transitional treatment plant approvals</heading><historynote><txt break.before="1"><b>pt&#160;4 div&#160;5 hdg</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote><clause id="sec.32" guid="_4495d9d1-1297-4998-b347-d78458256d85" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>32</no><heading id="sec.32-he" guid="_60644396-6011-4eae-b4b6-3f204a94dc57">Purposes of division</heading><block><txt break.before="0">The purposes of this division are—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.32-para1.a" guid="_6c2cec09-b52f-4608-8cb9-0201d65f4f0b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">to enable a person who held an existing treatment plant approval on 31 December 2023 to apply, by 1 July 2024, for a treatment plant approval that remains in force until 31 December 2024; and</txt></block></li><li id="sec.32-para1.b" guid="_516b7c1b-d5ab-4e35-8120-eb0b25db3aa9" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">to provide for the application to be decided on the basis of compliance with the previous Queensland Plumbing and Wastewater Code rather than the criteria under <intref refid="sec.19" target.guid="_b763e4d7-ba16-4a6a-b154-a066d5c02f7c" check="valid">section&#160;19</intref>.</txt></block></li></list></block><historynote><txt break.before="1"><b>s&#160;32</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote></clause><clause id="sec.33" guid="_602ee7d9-bdf8-45d4-a890-5c5dbc78b351" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>33</no><heading id="sec.33-he" guid="_ec3e5e79-a0a2-43e6-b22f-bd7b8ad9bd9c">Definitions for division</heading><block><txt break.before="1">In this division—</txt><deflist><definition id="sec.33-def.existingtreatmentplantapproval_" guid="_9ab15d31-c982-4b52-9cb3-7a60a28634cf" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.33-def.existingtreatmentplantapproval" guid="_fffa30fd-2e93-45f1-80e6-ee98fd81a9ab" type="definition">existing treatment plant approval</defterm> means a treatment plant approval mentioned in <legref jurisd="QLD" type="act" refid="sec.169" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b87177e5-3463-4334-868b-47e1cd8d4a1f" check="valid">section&#160;169</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>.</txt></definition><definition id="sec.33-def.previousQueenslandPlumbingandWastewaterCode_" guid="_76771454-81b1-47f5-a151-3e184418b916" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.33-def.previousQueenslandPlumbingandWastewaterCode" guid="_7b8bd985-a899-4f6a-bcd8-6d2416442f49" type="definition">previous Queensland Plumbing and Wastewater Code</defterm> means the document called ‘Queensland Plumbing and Wastewater Code’—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.33-def.previousQueenslandPlumbingandWastewaterCode-para1.a" guid="_43ea46a8-5d75-4721-a2b1-ae7bda1ad4bc" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">published by the department on 26 October 2017; and</txt></block></li><li id="sec.33-def.previousQueenslandPlumbingandWastewaterCode-para1.b" guid="_e34aa361-df92-43cd-b840-4bcca28b952c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">available on the department’s website.</txt></block></li></list></definition><definition id="sec.33-def.transitionaltreatmentplantapproval_" guid="_42cbfe24-7128-441c-bd74-9db251601ed5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.33-def.transitionaltreatmentplantapproval" guid="_87a29493-3edd-4f01-b9c9-67106c978228" type="definition">transitional treatment plant approval</defterm> see <intref refid="sec.35" target.guid="_0b1cd8cc-c30b-4c72-8078-3c6c83e55bc9" check="valid">section&#160;35</intref><intref refid="sec.35-ssec.2" target.guid="_3b430d7a-f6d3-471e-8d81-70bb307f7e5c" check="valid">(2)</intref>.</txt></definition></deflist></block><historynote><txt break.before="1"><b>s&#160;33</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote></clause><clause id="sec.34" guid="_20f9b59e-6903-41ec-97f6-121c1a95f82d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>34</no><heading id="sec.34-he" guid="_0d143eda-09b6-4319-b072-4b8bcbeaa4f8">Approval of previous Queensland Plumbing and Wastewater Code—<legref jurisd="QLD" type="act" check="invalid">Act</legref>, <legref jurisd="QLD" type="act" check="invalid">s&#160;7</legref></heading><subclause id="sec.34-ssec.1" guid="_caaa1c16-120a-453c-a34c-900cb8bca5f7" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" check="invalid">section&#160;7</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" check="invalid">Act</legref>, the previous Queensland Plumbing and Wastewater Code is approved only in relation to work for a transitional treatment plant approval.</txt></block></subclause><subclause id="sec.34-ssec.2" guid="_c78c7d17-074a-4e7b-ba8a-47515cab55b3" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">This section applies despite <intref refid="sec.8" target.guid="_38a5e7eb-d334-49ad-b8d5-43d2fed924c4" check="valid">section&#160;8</intref>.</txt></block></subclause><subclause id="sec.34-ssec.3" guid="_97ecede4-f56a-4139-a433-0d848a76a09b" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">For <intref refid="sec.34-ssec.1" target.guid="_caaa1c16-120a-453c-a34c-900cb8bca5f7" check="valid">subsection&#160;(1)</intref>, a reference in the previous Queensland Plumbing and Wastewater Code to a provision or matter in the repealed Act or repealed <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2003-0265" target.version.series="d605e90b-654d-4c7e-94c5-d247f748f1ab" check="valid"><name emphasis="yes">Standard Plumbing and Drainage Regulation 2003</name></legref> is taken to be a reference to the corresponding provision or matter in the <legref jurisd="QLD" type="act" check="invalid">Act</legref> or this regulation.</txt></block></subclause><subclause id="sec.34-ssec.4" guid="_70e771a6-57f7-475c-a844-5fcb013dc02a" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.34-ssec.4-def.correspondingprovision_" guid="_b68ee071-36e6-4aed-9e93-e7a45add21da" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.34-ssec.4-def.correspondingprovision" guid="_7be07247-6bd0-4771-97aa-211701512966" type="definition">corresponding provision</defterm>, for a provision of the repealed Act or repealed <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2003-0265" target.version.series="d605e90b-654d-4c7e-94c5-d247f748f1ab" check="valid"><name emphasis="yes">Standard Plumbing and Drainage Regulation 2003</name></legref>, means a provision of the <legref jurisd="QLD" type="act" check="invalid">Act</legref> or this regulation that is substantially the same as the provision of the repealed Act or repealed <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2003-0265" target.version.series="d605e90b-654d-4c7e-94c5-d247f748f1ab" check="valid"><name emphasis="yes">Standard Plumbing and Drainage Regulation 2003</name></legref>.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;34</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote></clause><clause id="sec.35" guid="_0b1cd8cc-c30b-4c72-8078-3c6c83e55bc9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>35</no><heading id="sec.35-he" guid="_ce001099-8a81-42e1-822b-d03a92ce5523">Application for and deciding transitional treatment plant approvals</heading><subclause id="sec.35-ssec.1" guid="_674b0cf5-c526-4d5b-a734-c07521b47b6f" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies in relation to a person who was, on 31 December 2023, the holder of an existing treatment plant approval.</txt></block></subclause><subclause id="sec.35-ssec.2" guid="_3b430d7a-f6d3-471e-8d81-70bb307f7e5c" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The person may apply under this section for a treatment plant approval (a <defterm id="sec.35-def.transitionaltreatmentplantapproval" guid="_20c034ee-6dab-4746-a08a-85c7be90db81" type="definition">transitional treatment plant approval</defterm>).</txt></block></subclause><subclause id="sec.35-ssec.3" guid="_9e3ac0ad-f9a8-4541-b1d2-c410ba979ff1" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The application must be—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.35-ssec.3-para1.a" guid="_e474a321-dbc9-4c2a-99af-b14b162b89de" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">made in the approved form before 1 July 2024; and</txt></block></li><li id="sec.35-ssec.3-para1.b" guid="_b2a943eb-89dd-47de-8f70-3e17bf1b2e56" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for a treatment plant that was, on 31 December 2023, the subject of the existing treatment plant approval held by the applicant.</txt></block></li></list></block></subclause><subclause id="sec.35-ssec.4" guid="_308f5aa2-a417-4d42-b54a-59d79f20c898" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">Subject to <intref refid="sec.35-ssec.5" target.guid="_c5decee9-55b9-49ed-9b67-b101870eb514" check="valid">subsections&#160;(5)</intref> to <intref refid="sec.35-ssec.7" target.guid="_e2a67fd8-cb74-44cd-aaa5-ebf0d2f163f2" check="valid">(7)</intref>, <intref refid="pt.4-div.1" target.guid="_4bfcbd21-e508-4dd0-995b-c75967905f81" check="valid">division&#160;1</intref> applies to the application as if the application were an application for a treatment plant approval under that division.</txt></block></subclause><subclause id="sec.35-ssec.5" guid="_c5decee9-55b9-49ed-9b67-b101870eb514" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0"><intref refid="sec.16" target.guid="_db274771-cdf5-47c5-a844-cef833ef5a69" check="valid">Section&#160;16</intref><intref refid="sec.16-ssec.3" target.guid="_5f4522f2-e730-4b50-8285-263c2aca5ba7" check="valid">(3)</intref> does not apply in relation to the application.</txt></block></subclause><subclause id="sec.35-ssec.6" guid="_7b98c419-6e1e-41e9-a543-325565cc32e4" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0"><intref refid="sec.19" target.guid="_b763e4d7-ba16-4a6a-b154-a066d5c02f7c" check="valid">Section&#160;19</intref> does not apply for deciding the application.</txt></block></subclause><subclause id="sec.35-ssec.7" guid="_e2a67fd8-cb74-44cd-aaa5-ebf0d2f163f2" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">The chief executive may decide to approve the application if satisfied a treatment plant of the type the subject of the application will comply with the previous Queensland Plumbing and Wastewater Code as approved under <intref refid="sec.34" target.guid="_20f9b59e-6903-41ec-97f6-121c1a95f82d" check="valid">section&#160;34</intref>.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;35</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote></clause><clause id="sec.35A" guid="_1b16a6b4-8602-40c3-9b3c-f6342320a328" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>35A</no><heading id="sec.35A-he" guid="_a8aec567-28c3-4f6b-bfcf-546e8b5e064b">Duration of transitional treatment plant approvals</heading><subclause id="sec.35A-ssec.1" guid="_673f9432-e30d-468f-9acc-5463283bf525" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A transitional treatment plant approval remains in force until 31 December 2024.</txt></block></subclause><subclause id="sec.35A-ssec.2" guid="_07fecc7e-da96-4f52-93a3-55aa4fe507a2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">This section applies despite <intref refid="sec.23" target.guid="_93758392-1aad-4c09-a9bb-48e29972c18c" check="valid">section&#160;23</intref>.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;35A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote></clause><clause id="sec.35B" guid="_4c1054c8-f563-4bfb-b382-2d75ec7f0e4d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>35B</no><heading id="sec.35B-he" guid="_3c6d83dd-5802-402d-98b2-d27e57c9cb81">Expiry of division</heading><block><txt break.before="1">This division expires on 1 January 2025.</txt></block><historynote><txt break.before="1"><b>s&#160;35B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_c5ab5736-d862-44bc-bee6-aed8494bd761" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote><historynote><txt break.before="1">exp 1 January 2025 (see s&#160;35B)</txt></historynote></clause></division></part><part id="pt.5" guid="_357246d4-1e65-48ec-b9a7-5400c77d68d5" affected.by.uncommenced="0"><no>Part 5</no><heading id="pt.5-he" guid="_4de9c770-9273-464c-be80-578a1059013e">Permits</heading><division id="pt.5-div.1" guid="_a0c6c490-67b0-4c25-9318-c320ad558c03" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.5-div.1-he" guid="_d8f20a5d-fa8b-4492-a7cf-74e67e0921aa">Introduction</heading><clause id="sec.36" guid="_221da50a-0459-43df-94a3-f6b662a46819" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>36</no><heading id="sec.36-he" guid="_75934fc1-c9b5-4af2-a154-ec927f21f9cc">What this part is about</heading><block><txt break.before="1">This part is about applying for, issuing and amending permits to carry out—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.36-para1.a" guid="_92f22a5e-ca0b-429f-83ce-ad22c5d7da9c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">permit work; or</txt></block></li><li id="sec.36-para1.b" guid="_b7ed7bef-192c-464d-87de-609cbb638028" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">notifiable work; or</txt></block></li><li id="sec.36-para1.c" guid="_08ae5bd5-c51a-4568-819f-33015e1169ac" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">both permit work and notifiable work.</txt></block></li></list><note id="sec.36-note" guid="_9db3f6cb-7bd5-4595-bb69-615a826a1c1e" type="example"><heading id="sec.36-note-he" guid="_53ac47fc-4c0e-4f95-b3c0-246c76f88d9e">Note—</heading><block><txt break.before="1">Other provisions of this regulation relate to notifiable work that is not the subject of a permit. See <intref refid="pt.6" target.guid="_35027ab7-1839-4560-ab40-318f4738b9bc" check="valid">part&#160;6</intref>, <intref refid="pt.6-div.6" target.guid="_a03d03e9-dbff-4618-9624-9e8add9cba0e" check="valid">division&#160;6</intref>.</txt></block></note></block></clause></division><division id="pt.5-div.2" guid="_739f64a2-5458-4cb7-aab6-900e306592c7" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.5-div.2-he" guid="_57a70d4d-ac27-4298-a259-27f9040dd099">Permits issued by local governments</heading><subdivision id="pt.5-div.2-sdiv.1" guid="_9d6c2a2b-98ee-4639-a4be-71a841669bb3" affected.by.uncommenced="0"><no>Subdivision 1</no><heading id="pt.5-div.2-sdiv.1-he" guid="_201dd9ba-97bd-4bec-9d28-1fe9db9cba09">Preliminary</heading><clause id="sec.37" guid="_2f9b9a4b-6736-41a0-9a67-1181e22b704c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>37</no><heading id="sec.37-he" guid="_229fec32-d51a-4c2d-8f4a-d25dd9b7728d">Meaning of <defterm id="sec.37-def.fasttrackpermitwork" guid="_f127d8a5-771f-4c58-9093-f0805c77a1d8" type="mention">fast-track permit work</defterm></heading><subclause id="sec.37-ssec.1" guid="_f47ad009-073a-4538-bebf-1f1dbdedaaa7" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Generally, permit work is <defterm id="sec.37-def.fasttrackpermitwork-oc.2" guid="_7fc3e25b-7c07-43e3-a40c-1945c93717dc" type="definition">fast-track permit work</defterm> if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.37-ssec.1-para1.a" guid="_8280e41d-ef80-43b6-bc93-5a4e5879b681" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the work is carried out, or is to be carried out, under a permit authorising work on— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.37-ssec.1-para1.a-para2.i" guid="_610b4642-fbd7-402a-b480-39c1cb31d9e9" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">only 1 new class 1a building or 1 new class 10a building; or</txt></block></li><li id="sec.37-ssec.1-para1.a-para2.ii" guid="_64ae5164-5e70-450b-b9cc-ce6957e98903" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">only 1 new class 1a building and 1 new class 10a building associated with the class 1a building; and</txt></block></li></list></block></li><li id="sec.37-ssec.1-para1.b" guid="_002347b9-f03d-4744-9adc-0babc5de79c7" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the work is carried out, or is to be carried out, in a service area for a retail water service and a sewerage service; and </txt></block></li><li id="sec.37-ssec.1-para1.c" guid="_4918d351-9113-487b-ac3c-69c68e0bccfc" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for a building mentioned in <intref refid="sec.37-ssec.1-para1.a" target.guid="_8280e41d-ef80-43b6-bc93-5a4e5879b681" check="valid">paragraph&#160;(a)</intref><intref refid="sec.37-ssec.1-para1.a-para2.i" target.guid="_610b4642-fbd7-402a-b480-39c1cb31d9e9" check="valid">(i)</intref>—the supply pipe for the building is connected directly and separately to the service provider’s water supply system; and</txt></block></li><li id="sec.37-ssec.1-para1.d" guid="_af2cb579-499d-4f03-99dd-d00ef95bea63" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">for the buildings mentioned in <intref refid="sec.37-ssec.1-para1.a" target.guid="_8280e41d-ef80-43b6-bc93-5a4e5879b681" check="valid">paragraph&#160;(a)</intref><intref refid="sec.37-ssec.1-para1.a-para2.ii" target.guid="_64ae5164-5e70-450b-b9cc-ce6957e98903" check="valid">(ii)</intref>—1 supply pipe for both of the buildings is connected directly and separately to the service provider’s water supply system; and</txt></block></li><li id="sec.37-ssec.1-para1.e" guid="_e84c426e-428d-49f9-8876-1fa205e9a852" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">for a building mentioned in <intref refid="sec.37-ssec.1-para1.a" target.guid="_8280e41d-ef80-43b6-bc93-5a4e5879b681" check="valid">paragraph&#160;(a)</intref><intref refid="sec.37-ssec.1-para1.a-para2.i" target.guid="_610b4642-fbd7-402a-b480-39c1cb31d9e9" check="valid">(i)</intref> or either or both of the buildings mentioned in <intref refid="sec.37-ssec.1-para1.a" target.guid="_8280e41d-ef80-43b6-bc93-5a4e5879b681" check="valid">paragraph&#160;(a)</intref><intref refid="sec.37-ssec.1-para1.a-para2.ii" target.guid="_64ae5164-5e70-450b-b9cc-ce6957e98903" check="valid">(ii)</intref>—the sanitary drain for the building or buildings is connected directly and separately to the service provider’s sewerage system.</txt></block></li></list></block></subclause><subclause id="sec.37-ssec.2" guid="_a44f5e34-0222-43f3-b8a9-6f47464195f2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For <intref refid="sec.37-ssec.1" target.guid="_f47ad009-073a-4538-bebf-1f1dbdedaaa7" check="valid">subsection&#160;(1)</intref><intref refid="sec.37-ssec.1-para1.a" target.guid="_8280e41d-ef80-43b6-bc93-5a4e5879b681" check="valid">(a)</intref><intref refid="sec.37-ssec.1-para1.a-para2.ii" target.guid="_64ae5164-5e70-450b-b9cc-ce6957e98903" check="valid">(ii)</intref>, a class 10a building is associated with a class 1a building if a person who is entitled to use the class 1a building would ordinarily also be entitled to use the class 10a building.</txt></block></subclause><subclause id="sec.37-ssec.3" guid="_376c61ff-28f3-44f4-9480-1a09efbf2e7d" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Also, <defterm id="sec.37-def.fasttrackpermitwork-oc.3" guid="_5aa0b926-ffed-4076-80e8-8d63bb7ad729" type="definition">fast-track permit work</defterm>, for a particular local government area, includes other permit work of a type the local government has declared to be fast-track permit work for the local government area under a fast-track work declaration.</txt></block></subclause><subclause id="sec.37-ssec.4" guid="_2c7167e9-220a-46d6-b617-48886b44ab63" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">However, the following work is not <defterm id="sec.37-def.fasttrackpermitwork-oc.4" guid="_849cc4c7-90ec-4788-9680-d249b5ff133c" type="definition">fast-track permit work</defterm>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.37-ssec.4-para1.a" guid="_eb1bdf45-d3d9-481e-8929-0414e7f0fe77" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">work involving installing a fixture relating to trade waste; </txt></block></li><li id="sec.37-ssec.4-para1.b" guid="_75c0fdf3-607b-485a-bcd7-27ca6063e047" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">work involving building, installing or altering—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.37-ssec.4-para1.b-para2.i" guid="_8175ea82-2774-478a-8d79-22bcc4a3d4ae" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a greywater use facility; or</txt></block></li><li id="sec.37-ssec.4-para1.b-para2.ii" guid="_693b0286-e967-4e54-a60e-658f17d9a397" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">an on-site sewage facility; </txt></block></li></list></block></li><li id="sec.37-ssec.4-para1.c" guid="_d28fcccf-46fc-47a5-9b20-444524bb6195" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">work carried out, or to be carried out, in a local government area for which a fast-track opt-out declaration is in force. </txt></block></li></list></block></subclause></clause><clause id="sec.38" guid="_bffb25e9-65c6-4add-980a-427d52c38b01" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>38</no><heading id="sec.38-he" guid="_f3c9cd2f-7394-44ab-a34f-b5aa948ecfe5">Meaning of <defterm id="sec.38-def.fasttrackapplication" guid="_0bcdbd75-6064-4c9f-ac9a-da961475156c" type="mention">fast-track application</defterm> and <defterm guid="_4a4cbc7e-26dd-47f0-a4c3-f2bbfb5c635f" type="mention">fast-track amendment application</defterm></heading><subclause id="sec.38-ssec.1" guid="_11c23c10-5831-407d-a39b-b0c5ac74b541" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A <defterm id="sec.38-def.fasttrackapplication-oc.2" guid="_c2ef851d-5032-4703-96d5-c22b118b1282" type="definition">fast-track application</defterm> is an application to a local government under this division for a permit for carrying out fast-track permit work.</txt></block></subclause><subclause id="sec.38-ssec.2" guid="_9dbdd6b6-1a08-4318-8771-f1feee8bd3b2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A <defterm id="sec.38-def.fasttrackamendmentapplication-oc.2" guid="_9e98cb41-0df7-497b-9c9a-bbec3823fdd7" type="definition">fast-track amendment application</defterm> is an application to a local government under this division to amend a permit mentioned in <intref refid="sec.38-ssec.1" target.guid="_11c23c10-5831-407d-a39b-b0c5ac74b541" check="valid">subsection&#160;(1)</intref> for which a fast-track application was made.</txt></block></subclause><subclause id="sec.38-ssec.3" guid="_3901056a-4ded-4178-911b-81267c720d25" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, an application for, or to amend, a permit for carrying out work in a local government area is not a fast-track application or fast-track amendment application if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.38-ssec.3-para1.a" guid="_6c761d07-4e0b-4dc9-b9cc-8d90b2fb58f4" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">when the application is made, a fast-track opt-out declaration is in force for the local government area; or</txt></block></li><li id="sec.38-ssec.3-para1.b" guid="_da3019e8-4f82-4629-9a00-39e4a66914da" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for the application, a performance solution is proposed to be used to comply with a performance requirement of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.38-ssec.3-para1.b-para2.i" guid="_4e8c024f-6403-45b3-b6eb-7212a89b0059" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the Queensland Plumbing and Wastewater Code; or</txt></block></li><li id="sec.38-ssec.3-para1.b-para2.ii" guid="_4a26baeb-0392-4e0f-9eef-62b8abfdacc6" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the Plumbing Code of Australia; or</txt></block></li></list></block></li><li id="sec.38-ssec.3-para1.c" guid="_dfc40554-764b-45a5-a213-5231af9508bb" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for the application, an alternative solution under the Queensland Development Code is proposed to be used to comply with a performance criteria of that code.</txt></block></li></list></block></subclause></clause></subdivision><subdivision id="pt.5-div.2-sdiv.2" guid="_8177fd84-bc05-4afd-b024-3809b54460ef" affected.by.uncommenced="0"><no>Subdivision 2</no><heading id="pt.5-div.2-sdiv.2-he" guid="_8a6fa641-a3f4-4346-a6cd-e08d13657f6a">Local government declarations about permit work</heading><clause id="sec.39" guid="_79d99485-b4b0-4c80-afae-6626f9d7e84c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>39</no><heading id="sec.39-he" guid="_97a7443d-af6a-4acd-b395-60615adb923a">Fast-track work declaration for a local government area</heading><subclause id="sec.39-ssec.1" guid="_0952c903-536a-40f8-b978-8105d55d018a" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government may, by resolution, declare permit work of a stated type to be fast-track permit work for its local government area (a <defterm id="sec.39-def.fasttrackworkdeclaration" guid="_f3046062-b5df-4b37-8c0a-ad6883cdb311" type="definition">fast-track work declaration</defterm>). </txt></block></subclause><subclause id="sec.39-ssec.2" guid="_580b090c-766f-4031-bfe8-f0ef63ed4b4b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">However, a local government may not declare permit work to be fast-track permit work under <intref refid="sec.39-ssec.1" target.guid="_0952c903-536a-40f8-b978-8105d55d018a" check="valid">subsection&#160;(1)</intref> if the permit work is work mentioned in <intref refid="sec.37" target.guid="_2f9b9a4b-6736-41a0-9a67-1181e22b704c" check="valid">section&#160;37</intref><intref refid="sec.37-ssec.4" target.guid="_2c7167e9-220a-46d6-b617-48886b44ab63" check="valid">(4)</intref><intref refid="sec.37-ssec.4-para1.a" target.guid="_eb1bdf45-d3d9-481e-8929-0414e7f0fe77" check="valid">(a)</intref>, <intref refid="sec.37-ssec.4-para1.b" target.guid="_75c0fdf3-607b-485a-bcd7-27ca6063e047" check="valid">(b)</intref> or <intref refid="sec.37-ssec.4-para1.c" target.guid="_d28fcccf-46fc-47a5-9b20-444524bb6195" check="valid">(c)</intref>.</txt></block></subclause><subclause id="sec.39-ssec.3" guid="_3cc82148-63cf-41bf-9423-a416de76ba57" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">A fast-track work declaration applies in relation to permit work carried out on or after the day the declaration is made.</txt></block></subclause></clause><clause id="sec.40" guid="_0c3b5e7a-2518-4fb1-b322-475e2348d3fd" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>40</no><heading id="sec.40-he" guid="_032d4505-31d3-4feb-8198-a46962305ee4">Fast-track opt-out declaration for local government area</heading><subclause id="sec.40-ssec.1" guid="_7e93f368-8535-4cd4-a95e-540427655241" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government may, by resolution, declare that it will not deal with any applications relating to permits for work to be carried out in its local government area as fast-track applications (a <defterm id="sec.40-def.fasttrackoptoutdeclaration" guid="_182e14b6-b598-43db-8413-112fdc29b3e5" type="definition">fast-track opt-out declaration</defterm>). </txt></block></subclause><subclause id="sec.40-ssec.2" guid="_cc4fae02-5e03-45d2-9ed1-831f696b0544" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A fast-track opt-out declaration applies in relation to an application for, or to amend, a permit made on or after the day the declaration is made.</txt></block></subclause></clause><clause id="sec.41" guid="_86e98696-9024-4740-9a78-eb64fe356b50" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>41</no><heading id="sec.41-he" guid="_1ffcca48-df29-4baf-9649-caa2e54dc48f">Publishing declarations</heading><subclause id="sec.41-ssec" guid="_58aaa65d-e130-4e5b-9f7d-c984ea90a227" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">If a local government makes a fast-track work declaration or fast-track opt-out declaration for its local government area, the local government must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.41-ssec-para1.a" guid="_c367e256-321a-4e0e-a6a4-3072fd5898a6" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">publish the declaration on its website; and</txt></block></li><li id="sec.41-ssec-para1.b" guid="_c37b5dd9-534a-4663-b354-b9581dc1e3cf" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">give a copy of the declaration to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.41-ssec-para1.b-para2.i" guid="_9990d055-62ef-4c7f-8ed8-aa0fb71805e1" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the chief executive; and</txt></block></li><li id="sec.41-ssec-para1.b-para2.ii" guid="_45f3acb7-9e21-445c-9cf4-bdd23287b5df" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the local government is a participating local government for a distributor-retailer—the distributor-retailer; and</txt></block></li></list></block></li><li id="sec.41-ssec-para1.c" guid="_77b5cfe4-5a76-4e46-bff4-f480005af72c" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">ensure a copy of the declaration may be inspected, free of charge, at the local government’s public office.</txt></block></li></list></block></subclause></clause></subdivision><subdivision id="pt.5-div.2-sdiv.3" guid="_3d83fef3-307f-48c7-a1b2-c4c653253a75" affected.by.uncommenced="0"><no>Subdivision 3</no><heading id="pt.5-div.2-sdiv.3-he" guid="_1e4eba68-714f-4d39-b956-47b743d3ab32">Applying for, or to amend, local government permits</heading><clause id="sec.42" guid="_190000aa-8cc7-43e0-952b-c97df8af3cc8" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>42</no><heading id="sec.42-he" guid="_9a3236d5-c80b-418e-82b9-b528a3dc3a91">Applying to local government for permit</heading><subclause id="sec.42-ssec" guid="_56190019-3ce0-4cdd-a499-30afb73903cc" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">A person may apply under this division to a local government for a permit to carry out any of the following work in the local government area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.42-ssec-para1.a" guid="_cff771f1-4ed1-40ee-a6f0-d6d28baa4bed" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">permit work;</txt></block></li><li id="sec.42-ssec-para1.b" guid="_818ceef7-b473-4faf-9092-e9c848d223c9" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">notifiable work; </txt></block></li><li id="sec.42-ssec-para1.c" guid="_8bd89132-b81d-4f3d-a694-cd69f3e9adb0" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">both permit work and notifiable work.</txt></block></li></list></block></subclause></clause><clause id="sec.43" guid="_5950f1e5-d2ea-463b-ba8a-32bb57537bd5" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>43</no><heading id="sec.43-he" guid="_735557e9-239d-4406-a71a-cb7d6fccd310">Applying to local government to amend permit</heading><subclause id="sec.43-ssec.1" guid="_833e93e6-3092-4955-86ce-d497aa5dceca" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies in relation to a permit for work issued by a local government.</txt></block></subclause><subclause id="sec.43-ssec.2" guid="_8e3adf0b-e37c-4415-b183-b351c566a6f6" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An eligible person may apply under this division to the local government— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.43-ssec.2-para1.a" guid="_b2a1399e-6321-4841-bf7b-7136bfba71c5" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">to extend the term of the permit for no more than 2 years; or</txt><note id="sec.43-ssec.2-para1.a-note" guid="_b415a4ba-75e9-4fb5-87b3-639540f6cca4" type="example"><heading id="sec.43-ssec.2-para1.a-note-he" guid="_188aee03-7fda-4b40-852e-cf5b2b09f33c">Note—</heading><block><txt break.before="1">For the term of a permit, see <intref refid="sec.59" target.guid="_11ff3de8-38ba-4c3c-a4f1-11410ce03ce6" check="valid">section&#160;59</intref>.</txt></block></note></block></li><li id="sec.43-ssec.2-para1.b" guid="_94c2884d-90ac-4fea-bf2c-af618098a327" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">to otherwise amend the permit.</txt></block></li></list></block></subclause><subclause id="sec.43-ssec.3" guid="_ae61810c-393f-4e26-bab3-e376dd584d27" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If an inspector has given the responsible person for the work an action notice requiring the person to apply under this division to amend the permit, the responsible person must comply with the requirement by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.43-ssec.3-para1.a" guid="_5ea32d44-27cb-46dd-a00f-4a141906f4ed" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">making the application; or</txt></block></li><li id="sec.43-ssec.3-para1.b" guid="_7078e625-228f-4758-9ae0-d05c7b5fdc1d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">arranging for an eligible person to make the application for the responsible person.</txt></block></li></list></block></subclause><subclause id="sec.43-ssec.4" guid="_8646c45e-284f-46c5-bf8e-324cbdcaaa51" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.43-ssec.4-def.eligibleperson_" guid="_49aa5d51-8d55-4fc5-8b28-3a8f50bdcc62" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.43-ssec.4-def.eligibleperson" guid="_9f3f5d9b-448a-4979-bd99-ef52ef82c7ee" type="definition">eligible person</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.43-ssec.4-def.eligibleperson-para1.a" guid="_1e1b7175-6b02-435a-b351-1b1594f44320" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the permit holder; or</txt></block></li><li id="sec.43-ssec.4-def.eligibleperson-para1.b" guid="_4b5fcfba-d6f6-466a-8210-895b6d3d18cd" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the owner of the premises, if the owner of the premises is not the permit holder.</txt></block></li></list></definition></deflist></block></subclause></clause></subdivision><subdivision id="pt.5-div.2-sdiv.4" guid="_8e8bbce0-a332-4b4a-93a3-2155bf0e95c4" affected.by.uncommenced="0"><no>Subdivision 4</no><heading id="pt.5-div.2-sdiv.4-he" guid="_59349853-5d4d-4db0-b4fd-938364f23d50">Processing applications</heading><clause id="sec.44" guid="_4528f36f-7bd6-423d-a224-be2fb51c2190" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>44</no><heading id="sec.44-he" guid="_db96ca1b-333a-4a44-9b24-5ffeef2f0c6a">Requirements for application</heading><subclause id="sec.44-ssec.1" guid="_f3147a3a-63cf-4e61-bb19-69882dcb586d" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An application for, or to amend, a permit must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.44-ssec.1-para1.a" guid="_8231321e-c588-4b04-95be-1dfe3ab03fc7" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">be in the approved form; and</txt></block></li><li id="sec.44-ssec.1-para1.b" guid="_505229fa-66ab-4918-8e66-3f25dd936de3" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.44-ssec.1-para1.b-para2.i" guid="_ffd962d5-d52d-4d48-9802-27c37335bed1" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the documents as required under <intref refid="sch.6" target.guid="_98d1b0de-bce6-4071-a8e5-e9bf5bfcc1c1" check="valid">schedule&#160;6</intref>; and</txt></block></li><li id="sec.44-ssec.1-para1.b-para2.ii" guid="_6ec92ee7-3270-47c8-b82a-038de841f647" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the application relates to SEQ water work and the local government is not the water service provider for the premises—the SEQ service provider’s written consent for the work; and</txt></block></li><li id="sec.44-ssec.1-para1.b-para2.iii" guid="_cbdfef02-6058-42a0-bfdb-79cd603433f6" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">if the application relates to SEQ sewerage work and the local government is not the sewerage service provider for the premises—the SEQ service provider’s written consent for the work; and</txt></block></li><li id="sec.44-ssec.1-para1.b-para2.iv" guid="_5fdcb87a-ba70-43f2-979c-5198d89e2d76" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">the local government application fee. </txt></block></li></list></block></li></list></block></subclause><subclause id="sec.44-ssec.2" guid="_8e0cb925-6a10-4bab-8f36-bcdfa157b539" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An application to extend the term of a permit must be made at least 10 business days before the end of the term of the permit. </txt></block></subclause><subclause id="sec.44-ssec.3" guid="_298ef674-0de4-43cd-8edb-02000c3117ee" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Despite <intref refid="sec.44-ssec.1" target.guid="_f3147a3a-63cf-4e61-bb19-69882dcb586d" check="valid">subsection&#160;(1)</intref><intref refid="sec.44-ssec.1-para1.b" target.guid="_505229fa-66ab-4918-8e66-3f25dd936de3" check="valid">(b)</intref><intref refid="sec.44-ssec.1-para1.b-para2.i" target.guid="_ffd962d5-d52d-4d48-9802-27c37335bed1" check="valid">(i)</intref>, an application to amend a permit is not required to be accompanied by a document mentioned in <intref refid="sch.6" target.guid="_98d1b0de-bce6-4071-a8e5-e9bf5bfcc1c1" check="valid">schedule&#160;6</intref> if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.44-ssec.3-para1.a" guid="_0b493613-c6cd-4524-8dca-8e0f1fd0d66c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the document accompanied the application for the permit or a previous application to amend the permit; and </txt></block></li><li id="sec.44-ssec.3-para1.b" guid="_844084a5-aa5f-4885-a667-58490e9d30fc" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">there has been no change to any material particular in the information contained in the document.</txt></block></li></list></block></subclause><subclause id="sec.44-ssec.4" guid="_29031bfa-9cc8-41ef-ba28-a3a0db31e260" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">An application that complies with <intref refid="sec.44-ssec.1" target.guid="_f3147a3a-63cf-4e61-bb19-69882dcb586d" check="valid">subsections&#160;(1)</intref> to <intref refid="sec.44-ssec.3" target.guid="_298ef674-0de4-43cd-8edb-02000c3117ee" check="valid">(3)</intref> is a <defterm id="sec.44-def.properlymadeapplication" guid="_d072dc77-e775-4379-b851-3522e86e29cf" type="definition">properly made application</defterm>.</txt></block></subclause></clause><clause id="sec.45" guid="_ee5c71e8-6333-41bb-9838-2c59c293f839" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>45</no><heading id="sec.45-he" guid="_53206789-0806-4df3-8442-7b23152514a3">Request for further information for deciding application</heading><subclause id="sec.45-ssec.1" guid="_6c965cc0-499f-4112-af46-d0bbfd178230" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the local government considers—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.45-ssec.1-para1.a" guid="_88ca66af-c58d-4d12-8351-1a18d05ffd3f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the application is not a properly made application; or</txt></block></li><li id="sec.45-ssec.1-para1.b" guid="_1f3187e6-e6d5-4166-b03a-edb7c7374e6f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">that the local government does not have the expertise to assess work the subject of the application (the <defterm id="sec.45-ssec.1-def.specialistwork" guid="_a63829bd-0f46-4dee-b217-403b337ce6ae" type="definition">specialist work</defterm>); or</txt></block></li><li id="sec.45-ssec.1-para1.c" guid="_a1895902-81ee-44d0-a0f6-4f612ed92dde" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">that the local government requires further information to decide the application. </txt></block></li></list></block></subclause><subclause id="sec.45-ssec.2" guid="_2cddd462-ccaa-4e45-b137-a0231d79ad3b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may, by notice given to the applicant in the initial consideration period (an <defterm id="sec.45-def.informationrequest" guid="_8682e1bb-2efa-41f5-be16-68c88229e85a" type="definition">information request</defterm>), ask the applicant to do the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.45-ssec.2-para1.a" guid="_d21a7ba2-47fe-4592-9012-069cd41c760e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">if <intref refid="sec.45-ssec.1" target.guid="_6c965cc0-499f-4112-af46-d0bbfd178230" check="valid">subsection&#160;(1)</intref><intref refid="sec.45-ssec.1-para1.a" target.guid="_88ca66af-c58d-4d12-8351-1a18d05ffd3f" check="valid">(a)</intref> applies—give the local government further information, or do a thing, the local government considers necessary to make the application a properly made application;</txt></block></li><li id="sec.45-ssec.2-para1.b" guid="_637bc704-1bc0-4bd0-8194-a82cc6cf9e46" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if <intref refid="sec.45-ssec.1" target.guid="_6c965cc0-499f-4112-af46-d0bbfd178230" check="valid">subsection&#160;(1)</intref><intref refid="sec.45-ssec.1-para1.b" target.guid="_1f3187e6-e6d5-4166-b03a-edb7c7374e6f" check="valid">(b)</intref> applies—give the local government a compliance statement for the specialist work;</txt></block></li><li id="sec.45-ssec.2-para1.c" guid="_5ea94256-e63c-4bfc-9e33-23d7845b24bb" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">if <intref refid="sec.45-ssec.1" target.guid="_6c965cc0-499f-4112-af46-d0bbfd178230" check="valid">subsection&#160;(1)</intref><intref refid="sec.45-ssec.1-para1.c" target.guid="_a1895902-81ee-44d0-a0f6-4f612ed92dde" check="valid">(c)</intref> applies—give the local government further information required to decide the application.</txt></block></li></list></block></subclause><subclause id="sec.45-ssec.3" guid="_beebbbc8-b744-4516-89e1-097c5f7cb04f" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the local government gives the applicant an information request, the local government need not deal with the application until the applicant complies with the notice.</txt></block></subclause><subclause id="sec.45-ssec.4" guid="_897cf0d4-9618-4ef4-adca-f9de9b5e57c9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the applicant does not comply with the information request within 6 months after it is given, the local government—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.45-ssec.4-para1.a" guid="_29701d18-2c8f-4006-825f-ebf63a05cadc" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">may treat the application as having lapsed; and </txt></block></li><li id="sec.45-ssec.4-para1.b" guid="_fa24db80-7896-4acf-b06c-d57fc895f1cb" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">is not required to refund the local government application fee. </txt></block></li></list></block></subclause><subclause id="sec.45-ssec.5" guid="_36f35673-6ee3-42bb-b934-cf14adf2646c" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.45-ssec.5-def.initialconsiderationperiod_" guid="_a8dba4a0-7245-497e-a8a3-febfe597e182" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.45-ssec.5-def.initialconsiderationperiod" guid="_ed24ef2c-8b77-4705-b9df-5ae3528f0a45" type="definition">initial consideration period</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.45-ssec.5-def.initialconsiderationperiod-para1.a" guid="_eccd492f-4987-46c1-b1e9-c2862be2aba7" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for a fast-track application or fast-track amendment application—2 business days after the application is made; or</txt></block></li><li id="sec.45-ssec.5-def.initialconsiderationperiod-para1.b" guid="_da8e650f-29ba-44a6-ba43-ba9e6c7332b0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for another application—10 business days after the application is made.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.46" guid="_73aa312b-4682-45cd-aec1-7a50768ac390" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>46</no><heading id="sec.46-he" guid="_f9d75d50-ccef-48db-9320-cbe86ff7bfa6">Deciding application—generally</heading><subclause id="sec.46-ssec.1" guid="_105754f5-a056-4e8f-8a2c-ac4dba552472" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The local government must consider each properly made application and decide to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.46-ssec.1-para1.a" guid="_430f5629-c4b6-49e3-a614-07eeaf18152d" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">approve the application with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.46-ssec.1-para1.a-para2.i" guid="_4786836e-aadc-47e6-8af4-44f716557662" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">for an application relating to work for a treatment plant of a type the subject of a treatment plant approval—the conditions of the approval; and </txt></block></li><li id="sec.46-ssec.1-para1.a-para2.ii" guid="_f8dfc13f-1260-4524-8e8f-458b2595cf1d" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">any other conditions the local government considers reasonable and relevant for carrying out the work; or</txt></block></li></list></block></li><li id="sec.46-ssec.1-para1.b" guid="_35f7acbd-6ec7-4fde-9dae-7c10c90fd0b3" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">refuse the application. </txt></block></li></list></block></subclause><subclause id="sec.46-ssec.2" guid="_fb2e6da0-3fa0-4da3-9e8a-03b5367ee572" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Without limiting <intref refid="sec.46-ssec.1" target.guid="_105754f5-a056-4e8f-8a2c-ac4dba552472" check="valid">subsection&#160;(1)</intref><intref refid="sec.46-ssec.1-para1.a" target.guid="_430f5629-c4b6-49e3-a614-07eeaf18152d" check="valid">(a)</intref>, a condition mentioned in <intref refid="sec.46-ssec.1" target.guid="_105754f5-a056-4e8f-8a2c-ac4dba552472" check="valid">subsection&#160;(1)</intref><intref refid="sec.46-ssec.1-para1.a" target.guid="_430f5629-c4b6-49e3-a614-07eeaf18152d" check="valid">(a)</intref><intref refid="sec.46-ssec.1-para1.a-para2.ii" target.guid="_f8dfc13f-1260-4524-8e8f-458b2595cf1d" check="valid">(ii)</intref> may, for example, authorise the permit holder to install a holding tank on stated premises and require the permit holder to remove the holding tank from the premises within a stated period.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;46</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_285a2ec7-bb4e-490a-9970-c6899fbeeef5" valid.date="as.made" check="valid">s&#160;5</legref></txt></historynote></clause><clause id="sec.47" guid="_192284e1-6f86-4a8a-938f-b3b3333f8a75" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>47</no><heading id="sec.47-he" guid="_fa9913bb-97b6-4ce4-abed-7186e1302790">Deciding application—particular matters to be considered</heading><subclause id="sec.47-ssec.1" guid="_0e0589c5-ebde-40c4-a474-20793829a377" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For deciding a fast-track application, the local government may, but need not, assess whether each plan for work accompanying the application complies with the code requirements for the work.</txt></block></subclause><subclause id="sec.47-ssec.2" guid="_0154492c-7b42-482e-a15c-d6e0c0492c04" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For deciding an application, other than a fast-track application, the local government may approve the application if satisfied—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.2-para1.a" guid="_b366b4ee-a738-4cd9-89cd-202ea679b125" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">after assessing each plan mentioned in <intref refid="sch.6" target.guid="_98d1b0de-bce6-4071-a8e5-e9bf5bfcc1c1" check="valid">schedule&#160;6</intref>, <intref refid="sch.6-pt.2" target.guid="_e76860dd-7e44-4dc0-9451-39fdd61c728f" check="valid">part&#160;2</intref> accompanying the application, the plan complies with the code requirements for the work to which the application relates; and</txt></block></li><li id="sec.47-ssec.2-para1.b" guid="_8a854795-73c9-427a-8547-56f5c48c7102" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for an application relating to a greywater use facility that includes a greywater treatment plant, other than a greywater (cooling tower) treatment plant, in a sewered area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.2-para1.b-para2.i" guid="_af813c37-d4c2-424c-813f-4ce82e57f5d0" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the premises where the facility is proposed to be installed generates more than 3kL of greywater a day; and</txt></block></li><li id="sec.47-ssec.2-para1.b-para2.ii" guid="_09125e8e-07e0-45db-a494-c5185f6eae4e" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the treatment plant is of a type for which a treatment plant approval has been granted; and</txt></block></li><li id="sec.47-ssec.2-para1.b-para2.iii" guid="_92181bc5-0759-4971-9e0b-1c9ee005d20e" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">the proposed work complies with the treatment plant approval; and</txt></block></li><li id="sec.47-ssec.2-para1.b-para2.iv" guid="_520e5c07-d199-4ad7-813e-8db043d40289" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">greywater can be diverted to sanitary drainage by a manual diversion device; and</txt></block></li><li id="sec.47-ssec.2-para1.b-para2.v" guid="_149c8f3e-a6b8-41b3-8aeb-4a4969853d9b" provision.type="other" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="0">greywater will automatically overflow to sanitary drainage if the facility’s filtering or irrigation system is not working properly; and</txt></block></li></list></block></li><li id="sec.47-ssec.2-para1.c" guid="_c321b3c3-86fe-4562-8d4e-6574ca38500d" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for an application relating to a greywater use facility that includes a greywater treatment plant not in a sewered area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.2-para1.c-para2.i" guid="_899f6288-92af-404e-bbd6-e855abf87564" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the treatment plant is of a type for which a treatment plant approval has been granted; and</txt></block></li><li id="sec.47-ssec.2-para1.c-para2.ii" guid="_62ec9e22-e7de-4d3a-a8ab-8cb3d58f80b7" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the proposed work complies with the treatment plant approval; and</txt></block></li></list></block></li><li id="sec.47-ssec.2-para1.d" guid="_028c277f-b022-4c69-a6ec-d2da14889aa1" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">for an application relating to a greywater use facility that includes a greywater (cooling tower) treatment plant in a sewered area to treat greywater, other than kitchen greywater—the treatment plant will be able to treat the greywater to the required standard; and</txt></block></li><li id="sec.47-ssec.2-para1.e" guid="_954da912-db93-4006-a4c4-1a35817a5f39" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">for an application relating to a secondary on-site sewage treatment plant—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.2-para1.e-para2.i" guid="_60b07e68-bd20-49c4-87ab-438e4a151f24" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the treatment plant is of a type for which a treatment plant approval has been granted; and</txt></block></li><li id="sec.47-ssec.2-para1.e-para2.ii" guid="_0e48880f-8e94-44ad-a6ce-c7b6b6828d41" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the proposed work complies with the treatment plant approval.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.47-ssec.3" guid="_135e4173-cc8d-4853-9779-cc5e731e784f" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">For deciding an application relating to SEQ water work, the local government must not approve the application unless—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.3-para1.a" guid="_0563685b-4e87-4e03-a0ac-ed4ca2c9e693" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the local government is the water service provider for the premises; or </txt></block></li><li id="sec.47-ssec.3-para1.b" guid="_8315f0b5-9b7b-47d8-b942-f86d009525a6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the water service provider for the premises—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.3-para1.b-para2.i" guid="_be0ce319-9dfc-446d-81bd-28f5f62b61cd" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">has given the applicant written consent for the work; or </txt></block></li><li id="sec.47-ssec.3-para1.b-para2.ii" guid="_9c1c67d4-baba-42f5-a697-894e85de7167" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">has given the local government a notice stating that a permit for the type of work may be issued without the provider’s consent. </txt></block></li></list></block></li></list></block></subclause><subclause id="sec.47-ssec.4" guid="_2e51a209-8bcd-4711-9851-1cbed36f14f1" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">For deciding an application relating to SEQ sewerage work, the local government must not approve the application unless—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.4-para1.a" guid="_35ba1fca-25d8-4de4-92ce-14863e9ad131" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the local government is the sewerage service provider for the premises; or </txt></block></li><li id="sec.47-ssec.4-para1.b" guid="_e676228b-b196-4375-98f4-3d87967d3acf" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the sewerage service provider for the premises—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.4-para1.b-para2.i" guid="_8237b86d-ab4b-436f-b5c2-281a1818017a" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">has given the applicant written consent for the work; or </txt></block></li><li id="sec.47-ssec.4-para1.b-para2.ii" guid="_70ee25e2-bd47-45c7-8d80-a2b14ecac5b0" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">has given the local government a notice stating that a permit for the type of work may be issued without the provider’s consent. </txt></block></li></list></block></li></list></block></subclause><subclause id="sec.47-ssec.5" guid="_5999c83b-1445-4402-89e1-6002a6dcc194" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">For deciding an application for which the applicant has given a compliance statement for specialist work, the local government must approve the application to the extent it relates to the specialist work if satisfied the work, if carried out in compliance with the permit applied for, will comply with the code requirements for the work.</txt></block></subclause><subclause id="sec.47-ssec.6" guid="_bfbc2066-db26-4c13-9c6a-0ede48b57f90" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">For deciding an application to amend a permit, the local government may, but need not, consider a matter mentioned in <intref refid="sec.47-ssec.1" target.guid="_0e0589c5-ebde-40c4-a474-20793829a377" check="valid">subsection&#160;(1)</intref> to <intref refid="sec.47-ssec.5" target.guid="_5999c83b-1445-4402-89e1-6002a6dcc194" check="valid">(5)</intref> if the local government—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.6-para1.a" guid="_38743683-c3cd-472d-9e71-c8f3b4b36371" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">has already considered the matter in deciding the application for the issue of the permit or a previous application to amend the permit; and</txt></block></li><li id="sec.47-ssec.6-para1.b" guid="_72a8c8d4-1895-471f-b8ab-a9351bb57aba" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">is satisfied—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.47-ssec.6-para1.b-para2.i" guid="_3eccd29f-8aba-436a-b58e-31f743e5c2d7" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">there has been no material change in relation to the matter; and</txt></block></li><li id="sec.47-ssec.6-para1.b-para2.ii" guid="_12f18812-f0d7-4d6c-832e-92ffaa2efe60" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">it is not necessary to consider the matter for the application to amend the permit.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1">s&#160;47 amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_a5d9bde9-b688-4c8c-95e7-67bd93dda787" valid.date="as.made" check="valid">s&#160;6</legref></txt></historynote></clause><clause id="sec.48" guid="_0763a187-219c-4ed7-afa7-76c81dee04ee" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>48</no><heading id="sec.48-he" guid="_e5f4f78c-9cf5-4553-800d-315c9184d760">Issuing or amending permit</heading><subclause id="sec.48-ssec" guid="_76f273a5-6a78-46cc-ad5f-86773eefb54b" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">If the local government decides to approve the application, the local government must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.48-ssec-para1.a" guid="_2bbd548f-0b15-43af-8cd3-7398bf68d82c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">issue a permit, or an amended permit, in the approved form, to the applicant; and </txt></block></li><li id="sec.48-ssec-para1.b" guid="_ff9e6d58-cec7-4920-a558-cd6bd21ca976" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">give a copy of the permit, or amended permit, to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.48-ssec-para1.b-para2.i" guid="_c80712f2-f2ab-40ec-bdea-36424d05f378" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">if the applicant is not the permit holder—the permit holder; and </txt></block></li><li id="sec.48-ssec-para1.b-para2.ii" guid="_8579f646-15a3-41ac-97d2-d2bcd7b05945" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the applicant is not the owner of the premises—the owner of the premises; and </txt></block></li><li id="sec.48-ssec-para1.b-para2.iii" guid="_a440fcfa-927c-4924-ae0a-017ce7534343" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">if a distributor-retailer supplies a water service or sewerage service for the premises—the distributor-retailer; and </txt></block></li><li id="sec.48-ssec-para1.b-para2.iv" guid="_3d0a781e-c92c-4252-a27b-d2e792770218" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">if the work involves installing a water meter and the local government is not the water service provider for the premises—the water service provider. </txt></block></li></list></block></li></list></block></subclause></clause><clause id="sec.49" guid="_786050cb-516e-4a15-83cc-333bd4c85686" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>49</no><heading id="sec.49-he" guid="_ae7d3cf5-9628-4822-9282-d4635054e721">Failure to decide application</heading><subclause id="sec.49-ssec.1" guid="_037cf507-5f83-4fb8-896c-93256703b0c6" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the local government does not decide the application within the required period after— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.49-ssec.1-para1.a" guid="_dc150f6f-facf-41c8-ba51-5ecf5b70ff02" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the applicant has made the application; or </txt></block></li><li id="sec.49-ssec.1-para1.b" guid="_fc701c85-9d31-4855-801d-3a1a2e4a146a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the local government has given the applicant an information request—the applicant has complied with the notice. </txt></block></li></list></block></subclause><subclause id="sec.49-ssec.2" guid="_1766d6e7-402e-4734-ba5a-08979b27bd16" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government is taken to have decided to refuse the application.</txt></block></subclause><subclause id="sec.49-ssec.3" guid="_d8781a51-fcbb-4a93-839a-f7e1c2f01e85" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.49-ssec.3-def.requiredperiod_" guid="_a22dbd49-5d1d-47b2-90e7-c11cc51ce475" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.49-ssec.3-def.requiredperiod" guid="_f1aba02e-8889-479c-b894-d90e0ec43c03" type="definition">required period</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.49-ssec.3-def.requiredperiod-para1.a" guid="_7ad0621e-9c3f-4c62-8159-a08679e880eb" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for a fast-track application or fast-track amendment application—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.49-ssec.3-def.requiredperiod-para1.a-para2.i" guid="_e5b4935b-320d-4c2d-8a56-0e7d3544e05b" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">2 business days; or</txt></block></li><li id="sec.49-ssec.3-def.requiredperiod-para1.a-para2.ii" guid="_9728be1f-6f07-4ecd-8e36-6716891f17d7" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if a longer period is agreed between the local government and the applicant—the longer period; or</txt></block></li></list></block></li><li id="sec.49-ssec.3-def.requiredperiod-para1.b" guid="_a5df2ba6-8ee6-4055-9a84-8dd96884d76c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for another application—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.49-ssec.3-def.requiredperiod-para1.b-para2.i" guid="_624a939a-0809-4829-8efc-400f6c65e757" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">10 business days; or</txt></block></li><li id="sec.49-ssec.3-def.requiredperiod-para1.b-para2.ii" guid="_03c13b21-cdfc-4f24-9cbe-e0f274649c57" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if a longer period is agreed between the local government and the applicant—the longer period.</txt></block></li></list></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.50" guid="_14982af9-e357-4b6a-a577-c445b84c94ad" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>50</no><heading id="sec.50-he" guid="_95889c8b-196a-4009-9736-7407a91270fa">Information notice about decisions</heading><subclause id="sec.50-ssec.1" guid="_83c225c1-f95f-4574-91fd-b63c9936f4ab" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0"><intref refid="sec.50-ssec.2" target.guid="_e43ca63f-5373-45ad-ab85-c10b00f170fb" check="valid">Subsection&#160;(2)</intref> applies if the local government decides to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.50-ssec.1-para1.a" guid="_812252af-9904-4275-96b8-b36228b5e881" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">approve the application and issue the permit, or amended permit, with a condition mentioned in <intref refid="sec.46" target.guid="_73aa312b-4682-45cd-aec1-7a50768ac390" check="valid">section&#160;46(1)</intref><intref refid="sec.46-para1.a" check="invalid">(a)</intref><intref refid="sec.46-para1.a-para2.ii" check="invalid">(ii)</intref>; or</txt></block></li><li id="sec.50-ssec.1-para1.b" guid="_62e8237c-bd05-470f-8f6f-f4ed57d07222" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">refuse the application.</txt></block></li></list></block></subclause><subclause id="sec.50-ssec.2" guid="_e43ca63f-5373-45ad-ab85-c10b00f170fb" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must give the applicant an information notice about the decision.</txt></block></subclause><subclause id="sec.50-ssec.3" guid="_14cecded-d861-4ef1-9961-d03866f51a53" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If, under <intref refid="sec.49" target.guid="_786050cb-516e-4a15-83cc-333bd4c85686" check="valid">section&#160;49</intref>, the local government is taken to have decided to refuse the application, the applicant is entitled to be given an information notice about the decision.</txt><note id="sec.50-ssec.3-note" guid="_370ac837-4497-43ba-9319-fe8b44315d97" type="example"><heading id="sec.50-ssec.3-note-he" guid="_e7ec45a7-d3d2-422c-af7b-991b566f233e">Note—</heading><block><txt break.before="1">For an appeal against a decision mentioned in <intref refid="sec.50-ssec.1" target.guid="_83c225c1-f95f-4574-91fd-b63c9936f4ab" check="valid">subsection&#160;(1)</intref> or <intref refid="sec.50-ssec.3" target.guid="_14cecded-d861-4ef1-9961-d03866f51a53" check="valid">(3)</intref>, see the <legref jurisd="QLD" type="act" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" check="valid"><name emphasis="yes">Planning Act 2016</name></legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_b27e6fb3-817d-489b-ba9f-f87df89be113" check="valid">schedule&#160;1</legref>, <legref jurisd="QLD" type="act" refid="sch.1-sec.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_e79cbd63-ba5c-415b-bc7d-9217dd599138" check="valid">section&#160;1</legref>, table 3, items 3 and 5.</txt></block></note></block></subclause><historynote><txt break.before="1"><b>s&#160;50</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_0594e0fd-3e78-4ba1-9a7b-b2c2a6fe17bf" valid.date="as.made" check="valid">s&#160;7</legref></txt></historynote></clause></subdivision></division><division id="pt.5-div.3" guid="_4ca69da4-a214-4127-a93e-6a891f940a7f" affected.by.uncommenced="0"><no>Division 3</no><heading id="pt.5-div.3-he" guid="_1d00d210-c63a-44d5-80e1-8b27f0ce8735">Permits issued by public sector entities</heading><clause id="sec.51" guid="_03108d34-2063-40af-b9d2-0cb89a246db6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>51</no><heading id="sec.51-he" guid="_d70c7119-0fd6-4a1d-ab5b-02f970b837a6">Application of division</heading><subclause id="sec.51-ssec" guid="_777771fd-ccf1-4b8a-a7fc-d5b331e7df2c" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">This division applies if a public sector entity is about to carry out, or to arrange to have carried out, any of the following work under a permit, for the benefit of the public sector entity or another public sector entity— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.51-ssec-para1.a" guid="_ec05bb1a-d96a-4d99-a109-09b2a8e7c3a1" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">permit work;</txt></block></li><li id="sec.51-ssec-para1.b" guid="_16d3dc47-3dce-47a5-8be5-eb2ea8697de1" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">notifiable work;</txt></block></li><li id="sec.51-ssec-para1.c" guid="_e18d6a88-35c1-4991-85d2-1772011815e5" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">both permit work and notifiable work.</txt></block></li></list></block></subclause></clause><clause id="sec.52" guid="_f846f1c6-3348-4499-a23f-a3519fae2cde" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>52</no><heading id="sec.52-he" guid="_9a7c0fa5-8921-49b7-8156-c3b333ad4bb1">Applying for a permit</heading><subclause id="sec.52-ssec.1" guid="_fd83d78d-ba80-4698-9200-1656f3f2b429" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A person may apply for a permit to carry out the work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.52-ssec.1-para1.a" guid="_3c7cdad8-f6ba-4eb9-8b49-17fcf04b7ad4" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">to the public sector entity under this division; or</txt></block></li><li id="sec.52-ssec.1-para1.b" guid="_fb77c32e-bcab-4689-af7e-bb8aced63a2f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">to the local government under <intref refid="pt.5-div.2" target.guid="_739f64a2-5458-4cb7-aab6-900e306592c7" check="valid">division&#160;2</intref>.</txt></block></li></list></block></subclause><subclause id="sec.52-ssec.2" guid="_64d62ba7-b0cc-45b8-8218-9df0814955c6" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An application under <intref refid="sec.52-ssec.1" target.guid="_fd83d78d-ba80-4698-9200-1656f3f2b429" check="valid">subsection&#160;(1)</intref><intref refid="sec.52-ssec.1-para1.a" target.guid="_3c7cdad8-f6ba-4eb9-8b49-17fcf04b7ad4" check="valid">(a)</intref> must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.52-ssec.2-para1.a" guid="_320e4f20-695a-4e53-bda6-60381a6d125c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">be in the approved form; and</txt></block></li><li id="sec.52-ssec.2-para1.b" guid="_28fda1e1-c9dc-42e7-b9cd-b4372bf18a35" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">be accompanied by the documents as required under <intref refid="sch.6" target.guid="_98d1b0de-bce6-4071-a8e5-e9bf5bfcc1c1" check="valid">schedule&#160;6</intref>.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;52</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_869eca93-3882-4943-b025-671c67b3781d" valid.date="as.made" check="valid">s&#160;8</legref></txt></historynote></clause><clause id="sec.53" guid="_a0864b8c-e313-4f28-95f7-2ddf1d9fd243" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>53</no><heading id="sec.53-he" guid="_f5a01e12-99b5-4291-8f53-aa1dc0b6bb71">Public sector entity deciding application</heading><subclause id="sec.53-ssec.1" guid="_d12e87fe-936c-4887-a643-bb83ace1c60f" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The public sector entity must consider an application made under <intref refid="sec.52" target.guid="_f846f1c6-3348-4499-a23f-a3519fae2cde" check="valid">section&#160;52</intref><intref refid="sec.52-ssec.1" target.guid="_fd83d78d-ba80-4698-9200-1656f3f2b429" check="valid">(1)</intref><intref refid="sec.52-ssec.1-para1.a" target.guid="_3c7cdad8-f6ba-4eb9-8b49-17fcf04b7ad4" check="valid">(a)</intref> and decide to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.1-para1.a" guid="_4105a4ca-a573-49db-bf69-e6bbad2859b2" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">approve the application with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.1-para1.a-para2.i" guid="_42a2ed10-6dc7-40e1-b170-1638770d8c5f" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">for an application relating to work for a treatment plant of a type the subject of a treatment plant approval—the conditions of the approval; and </txt></block></li><li id="sec.53-ssec.1-para1.a-para2.ii" guid="_a249ccac-b928-4c9b-b73e-76022a4dd403" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">any other conditions the entity considers reasonable and relevant for carrying out the work; or</txt></block></li></list></block></li><li id="sec.53-ssec.1-para1.b" guid="_18279d4e-dd91-4b7d-9900-aa00f7192068" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">refer the application to the local government to decide under <intref refid="pt.5-div.2" target.guid="_739f64a2-5458-4cb7-aab6-900e306592c7" check="valid">division&#160;2</intref>.</txt></block></li></list></block></subclause><subclause id="sec.53-ssec.2" guid="_e0cf8dae-771e-4c6c-8f3b-c71e1d6f9995" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The public sector entity may approve the application if satisfied—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.a" guid="_07f21935-fd3a-4462-9d98-bbad8fe76014" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">after assessing each plan mentioned in <intref refid="sch.6" target.guid="_98d1b0de-bce6-4071-a8e5-e9bf5bfcc1c1" check="valid">schedule&#160;6</intref>, <intref refid="sch.6-pt.2" target.guid="_e76860dd-7e44-4dc0-9451-39fdd61c728f" check="valid">part&#160;2</intref> accompanying the application, the plan complies with the code requirements for the work to which the application relates; and</txt></block></li><li id="sec.53-ssec.2-para1.b" guid="_4afcb25c-73c6-43ab-8617-bfbbe3acd8d1" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for an application relating to a greywater use facility that includes a greywater treatment plant, other than a greywater (cooling tower) treatment plant, in a sewered area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.b-para2.i" guid="_4ced0006-e531-4f1c-8325-9e3e5488a44e" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the premises where the facility is proposed to be installed generates more than 3kL of greywater a day; and</txt></block></li><li id="sec.53-ssec.2-para1.b-para2.ii" guid="_790a00b0-7335-4b2b-ac39-fe178dddbee7" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the treatment plant is of a type for which a treatment plant approval has been granted; and</txt></block></li><li id="sec.53-ssec.2-para1.b-para2.iii" guid="_f6f4e7b8-2d69-4b1d-819b-45d934384fb2" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">the proposed work complies with the treatment plant approval; and</txt></block></li><li id="sec.53-ssec.2-para1.b-para2.iv" guid="_ba24fc73-7bf9-4c10-ab66-f1e3bf23adcc" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">greywater can be diverted to sanitary drainage by a manual diversion device; and</txt></block></li><li id="sec.53-ssec.2-para1.b-para2.v" guid="_f6e19b7c-b21a-41de-a138-2b2cc54abfe2" provision.type="other" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="0">greywater will automatically overflow to sanitary drainage if the facility’s filtering or irrigation system is not working properly; and</txt></block></li></list></block></li><li id="sec.53-ssec.2-para1.c" guid="_738ada03-5911-4151-97aa-c4fc71d39dec" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for an application relating to a greywater use facility that includes a greywater treatment plant not in a sewered area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.c-para2.i" guid="_9fe30c08-659f-4e4f-a616-855de962c2b5" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the treatment plant is of a type for which a treatment plant approval has been granted; and</txt></block></li><li id="sec.53-ssec.2-para1.c-para2.ii" guid="_8a8eb0c3-6a80-4efd-98b2-f1edff9f890f" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the proposed work complies with the treatment plant approval; and</txt></block></li></list></block></li><li id="sec.53-ssec.2-para1.d" guid="_81065944-c679-42ad-8d33-2dc694d69333" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">for an application relating to a greywater use facility that includes a greywater (cooling tower) treatment plant in a sewered area to treat greywater, other than kitchen greywater—the treatment plant will be able to treat the greywater to the required standard; and</txt></block></li><li id="sec.53-ssec.2-para1.e" guid="_dbadf8dd-4ef9-4544-a890-67179e8483b1" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">for an application relating to a secondary on-site sewage treatment plant—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.e-para2.i" guid="_dda66ab4-33e4-4d72-8cb3-b97e9a3e5f9e" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the treatment plant is of a type for which a treatment plant approval has been granted; and</txt></block></li><li id="sec.53-ssec.2-para1.e-para2.ii" guid="_d5d6beb3-24d5-47da-91fe-4b184c70a031" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the proposed work complies with the treatment plant approval; and</txt></block></li></list></block></li><li id="sec.53-ssec.2-para1.f" guid="_c41513fd-f0f7-4a1c-80a2-929c373327df" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">for an application relating to SEQ water work, written consent for the work has been given by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.f-para2.i" guid="_1b2f4413-4814-4474-a8a5-4b53567bca16" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the local government; or</txt></block></li><li id="sec.53-ssec.2-para1.f-para2.ii" guid="_c4fb035f-ec38-40ec-8434-0c15720ea63e" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the local government is not the water service provider for the premises—the water service provider; and</txt></block></li></list></block></li><li id="sec.53-ssec.2-para1.g" guid="_9e22f86b-a38b-4ffd-9be0-25bc861c892d" provision.type="other" affected.by.uncommenced="0"><no>(g)</no><block><txt break.before="0">for an application relating to SEQ sewerage work, written consent for the work has been given by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.g-para2.i" guid="_7eb02275-bf62-4a47-9019-989924c6d15c" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the local government; or</txt></block></li><li id="sec.53-ssec.2-para1.g-para2.ii" guid="_e39c3f64-52a6-4023-84ff-da605e08f01b" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the local government is not the sewerage service provider for the premises—the sewerage service provider.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;53</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_e3e8ff71-48d4-486c-b919-b2c3c14c135a" valid.date="as.made" check="valid">s&#160;9</legref></txt></historynote></clause><clause id="sec.54" guid="_663915cf-5ab1-4fab-9ef6-9ad57bf1a7b9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>54</no><heading id="sec.54-he" guid="_e65de56f-b8b8-431c-91fb-bb7b3d728292">Issue of permit by public sector entity</heading><subclause id="sec.54-ssec" guid="_7a0dcbf6-d497-4942-a445-2a1f9c503bad" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">If the public sector entity decides to approve the application, the entity must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.54-ssec-para1.a" guid="_29b107bc-af08-4b9f-85c5-c53cd07aeb97" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">issue a permit, in the approved form, to the applicant; and </txt></block></li><li id="sec.54-ssec-para1.b" guid="_029e1407-a116-4ba1-824c-56f2dc9bf6f4" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">give a copy of the permit to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.54-ssec-para1.b-para2.i" guid="_eece34aa-fe23-4101-a480-6ce80968ff8e" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">if the applicant is not the owner of the premises—the owner of the premises; and </txt></block></li><li id="sec.54-ssec-para1.b-para2.ii" guid="_2ba59dee-83b8-4f4e-aa35-d7d56e423e35" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the local government; and </txt></block></li><li id="sec.54-ssec-para1.b-para2.iii" guid="_1239abb2-a44d-4d0c-a85d-6be57ac02342" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">if a distributor-retailer supplies a water service or sewerage service for the premises—the distributor-retailer; and </txt></block></li><li id="sec.54-ssec-para1.b-para2.iv" guid="_a03b3b68-dedc-4a83-9361-fc5526e894e0" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">if the work involves installing a water meter and the local government is not the water service provider for the premises—the water service provider. </txt></block></li></list></block></li></list></block></subclause></clause><clause id="sec.55" guid="_fe56782c-f129-4b39-91a0-1ba168c87042" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>55</no><heading id="sec.55-he" guid="_384d07d6-024c-48d2-81f1-5f8bcbd90744">Notice of referral to local government</heading><block><txt break.before="1">If the public sector entity decides to refer the application to the local government under <intref refid="sec.53" target.guid="_a0864b8c-e313-4f28-95f7-2ddf1d9fd243" check="valid">section&#160;53</intref><intref refid="sec.53-ssec.1" target.guid="_d12e87fe-936c-4887-a643-bb83ace1c60f" check="valid">(1)</intref><intref refid="sec.53-ssec.1-para1.b" target.guid="_18279d4e-dd91-4b7d-9900-aa00f7192068" check="valid">(b)</intref>, the public sector entity must give the applicant notice of the decision.</txt></block></clause><clause id="sec.56" guid="_0715e2ba-1f96-43a4-8655-f4b6d8764e30" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>56</no><heading id="sec.56-he" guid="_2c4087b4-b157-493a-8a6a-cd7c78ecedab">Failure of public sector entity to decide application</heading><subclause id="sec.56-ssec.1" guid="_5359dae3-3eb3-49f6-95cd-3d96434a6ae9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">If the public sector entity does not decide the application within the required period, the entity is taken to have decided to refer the application to the local government.</txt></block></subclause><subclause id="sec.56-ssec.2" guid="_0eceeb14-d20a-4805-8ec7-6e71accf489c" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.56-ssec.2-def.requiredperiod_" guid="_f6364a85-ef9e-41c1-92dd-7a19a9d59b84" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.56-ssec.2-def.requiredperiod" guid="_23d67414-f546-426f-a4af-fc16e9030b08" type="definition">required period</defterm> means the following period after receiving the application—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.56-ssec.2-def.requiredperiod-para1.a" guid="_4d07b283-be3a-4aad-9beb-02d10443dbc9" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">10 business days; </txt></block></li><li id="sec.56-ssec.2-def.requiredperiod-para1.b" guid="_8ced6e22-6e3c-4d6e-9537-e352194ef0f7" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if a longer period is agreed between the public sector entity and the applicant—the longer period.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.57" guid="_913cd47a-1a2f-4ef8-ba22-0a8d4b49bf05" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>57</no><heading id="sec.57-he" guid="_0936072d-33b7-4217-849c-d2a1dc47a338">Amendment of permit</heading><subclause id="sec.57-ssec.1" guid="_7211f1da-ec84-49f6-ae7a-9419ee7e4f0c" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">If the public sector entity has issued a permit under <legref jurisd="QLD" type="act" refid="sec.54" check="invalid">section&#160;54</legref>, the permit may be amended by agreement between the entity and the permit holder.</txt></block></subclause><subclause id="sec.57-ssec.2" guid="_00d2cd17-d61c-4cf1-9998-3441b41dec83" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If a permit is amended under <legref jurisd="QLD" type="act" refid="sec.57-ssec.1" check="invalid">subsection&#160;(1)</legref>, the public sector entity must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.57-ssec.2-para1.a" guid="_e67dfb53-208d-4a1c-93e7-121176f5f086" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">issue the amended permit, in the approved form, to the permit holder; and</txt></block></li><li id="sec.57-ssec.2-para1.b" guid="_7bdf097f-61d1-4f2a-bcc4-0febb642935c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">give a copy of the amended permit to each entity to which a copy of the permit was required to be given under <legref jurisd="QLD" type="act" refid="sec.54" check="invalid">section&#160;54</legref><legref jurisd="QLD" type="act" refid="sec.54-para1.b" check="invalid">(b)</legref>.</txt></block></li></list></block></subclause></clause></division><division id="pt.5-div.4" guid="_2326b8fe-f0f9-42c7-bf5b-3ddd81a32673" affected.by.uncommenced="0"><no>Division 4</no><heading id="pt.5-div.4-he" guid="_e72836fc-b7fe-471e-b2d6-3a063e3ab31f">Effect and duration of permits</heading><clause id="sec.58" guid="_dda64c4c-38be-4412-bfd1-df55cd34c30e" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>58</no><heading id="sec.58-he" guid="_e0934d54-1207-47cc-b08b-a3ed502dde95">Permit attaches to premises</heading><block><txt break.before="1">A permit—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.58-para1.a" guid="_6763cf17-651a-4fa4-a18d-8c02af34eca6" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">attaches to the premises to which the permit relates; and</txt></block></li><li id="sec.58-para1.b" guid="_17518349-afb4-4cfd-9e81-ac2f28feac3a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">binds the owner, the owner’s successors in title, and any occupier of the premises.</txt></block></li></list></block></clause><clause id="sec.59" guid="_11ff3de8-38ba-4c3c-a4f1-11410ce03ce6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>59</no><heading id="sec.59-he" guid="_3b3c1cd6-903a-497a-973e-a0db9ef1257a">Duration of permit</heading><subclause id="sec.59-ssec.1" guid="_18e261b2-ef45-49e7-a6af-18bb288a7a8a" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A permit takes effect the day the permit is issued.</txt></block></subclause><subclause id="sec.59-ssec.2" guid="_61c42640-3379-4ec6-b2d3-5f4b38fd09b4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A permit ends—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.59-ssec.2-para1.a" guid="_39dbeccc-d617-4dfc-a136-4330f1413d44" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for a permit relating to installing a treatment plant of a type the subject of a treatment plant testing approval—the day, that is no more than 1 year after the permit takes effect, stated in the permit; or</txt></block></li><li id="sec.59-ssec.2-para1.b" guid="_57a141fa-7127-4f88-b986-db40c4719ceb" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">otherwise—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.59-ssec.2-para1.b-para2.i" guid="_c55ec50d-7310-4417-9d46-7605ae74bd7c" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the day, that is at least 2 years after the permit takes effect, stated in the permit; or</txt></block></li><li id="sec.59-ssec.2-para1.b-para2.ii" guid="_4832d625-f7f5-43af-a20c-12631c9ad7bc" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the term of the permit is extended on application under <intref refid="sec.43" target.guid="_5950f1e5-d2ea-463b-ba8a-32bb57537bd5" check="valid">section&#160;43</intref><intref refid="sec.43-ssec.2" target.guid="_8e3adf0b-e37c-4415-b183-b351c566a6f6" check="valid">(2)</intref><intref refid="sec.43-ssec.2-para1.a" target.guid="_b2a1399e-6321-4841-bf7b-7136bfba71c5" check="valid">(a)</intref>—at the end of the extended term.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.59-ssec.3" guid="_4962c508-6e97-4afd-a873-855f7363fa00" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If a local government has issued a permit and has not given a final inspection certificate for work carried out under the permit at least 3 months before the permit is to end, the local government must give notice of the day the permit is to end to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.59-ssec.3-para1.a" guid="_f2d91668-6104-4809-8f0a-35e187b2e87f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the permit holder; and</txt></block></li><li id="sec.59-ssec.3-para1.b" guid="_7de4adcb-3a5a-42c8-beef-f713c9886204" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the permit holder is not the owner of the premises to which the permit relates—the owner of the premises.</txt></block></li></list></block></subclause></clause></division></part><part id="pt.6" guid="_35027ab7-1839-4560-ab40-318f4738b9bc" affected.by.uncommenced="0"><no>Part 6</no><heading id="pt.6-he" guid="_8769676b-58e8-42d0-b137-2bf7059cc912">Inspecting, enforcing and certifying permit work and notifiable work</heading><division id="pt.6-div.1" guid="_a5f2376d-9b36-46c0-8f2f-c5369fea36de" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.6-div.1-he" guid="_6561b37a-19ed-4bbe-9907-244b7c12b98b">Preliminary</heading><clause id="sec.60" guid="_5fa5486e-8d75-48b2-bc57-cd2520f8aed3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>60</no><heading id="sec.60-he" guid="_b06ed00f-ef17-4176-8845-37a99e28f743">What this part is about</heading><subclause id="sec.60-ssec" guid="_6bd33018-e905-478d-975e-5cc1e45eacd5" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">This part is about—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.60-ssec-para1.a" guid="_dda30bcf-bccb-473d-a979-152dcb5dc56b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">inspecting work and alternative procedures for deciding whether or not work is compliant; and</txt></block></li><li id="sec.60-ssec-para1.b" guid="_b6290a37-7d73-41e7-8f0f-a7c805dddd6a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">procedures for assessing work; and</txt></block></li><li id="sec.60-ssec-para1.c" guid="_248dec40-05d6-4952-977b-d0649747e150" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">giving action notices for work; and</txt></block></li><li id="sec.60-ssec-para1.d" guid="_72260dad-de62-4254-b05c-f19d58d5c008" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">giving inspection certificates and final inspection certificates for work.</txt></block></li></list></block></subclause></clause><clause id="sec.61" guid="_37727a73-9fd9-4612-907f-29612344fec1" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>61</no><heading id="sec.61-he" guid="_e7ceae83-cced-4beb-a98d-33176c944a58">When work is compliant—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.69" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b914028b-9929-46c2-8a6e-14b3d879f0b9" check="valid">s&#160;69</legref></heading><subclause id="sec.61-ssec.1" guid="_e64352c2-4b82-45e2-8674-dc136b9e36f9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.69" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b914028b-9929-46c2-8a6e-14b3d879f0b9" check="valid">section&#160;69</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the prescribed matters that permit work must comply with to be compliant are the matters mentioned in <intref refid="sec.61-ssec.3" target.guid="_bf4d57da-84c8-42e9-b5a1-1f5673d8b19f" check="valid">subsection&#160;(3)</intref>.</txt></block></subclause><subclause id="sec.61-ssec.2" guid="_fc29377a-430a-47a3-806e-1a92aff5e1ac" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Notifiable work must also comply with the matters mentioned in <intref refid="sec.61-ssec.3" target.guid="_bf4d57da-84c8-42e9-b5a1-1f5673d8b19f" check="valid">subsection&#160;(3)</intref> to be compliant.</txt></block></subclause><subclause id="sec.61-ssec.3" guid="_bf4d57da-84c8-42e9-b5a1-1f5673d8b19f" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The permit work or notifiable work is compliant if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.61-ssec.3-para1.a" guid="_c81f8090-5bec-42a9-a159-7169cbad432f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the work complies with the code requirements for the work; and</txt></block></li><li id="sec.61-ssec.3-para1.b" guid="_ae25e068-70d2-4503-8130-65460f9ca038" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">each thing installed as part of the work is a thing to which any of <legref jurisd="QLD" type="act" refid="sec.65" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b4d29d10-8405-451e-a13b-3b5ec933e3b5" check="valid">section&#160;65</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref><legref jurisd="QLD" type="act" check="invalid">(a)</legref> to <legref jurisd="QLD" type="act" check="invalid">(f)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref> applies; and</txt></block></li><li id="sec.61-ssec.3-para1.c" guid="_f5b7e2b7-b16b-4fa3-9707-4c0c085eed84" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for work carried out under a permit, the work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.61-ssec.3-para1.c-para2.i" guid="_e0e52e09-764d-48ae-8390-0824b5bba597" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">complies with the permit and any conditions of the permit; and</txt></block></li><li id="sec.61-ssec.3-para1.c-para2.ii" guid="_58d2052f-d0df-4b7a-af3e-17b47cd81cdc" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">is consistent with the approved plans for the work.</txt></block></li></list></block></li></list></block></subclause></clause></division><division id="pt.6-div.2" guid="_1394e2e8-ac45-49cb-bde5-2434a9d0e394" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.6-div.2-he" guid="_bcadd6fc-b830-4b14-8f5f-db73cc3fa4b2">Inspecting work under permits</heading><subdivision id="pt.6-div.2-sdiv.1" guid="_e6250f76-1819-4ac7-9df3-f88495b368f3" affected.by.uncommenced="0"><no>Subdivision 1</no><heading id="pt.6-div.2-sdiv.1-he" guid="_1225c58a-56d9-40bd-8b6b-a00f0c1807e3">Inspecting work under permit issued by local government</heading><clause id="sec.62" guid="_2fb199b3-1566-4964-a882-bc2ccf714152" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>62</no><heading id="sec.62-he" guid="_c9b95f3d-109e-42d9-ad9e-92b843c0e999">Application of subdivision</heading><subclause id="sec.62-ssec.1" guid="_51dc743c-fa8b-4559-8364-2a6856436370" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This subdivision applies in relation to work carried out under a permit issued by a local government.</txt></block></subclause><subclause id="sec.62-ssec.2" guid="_1b3b8d00-09b7-4b58-a1c3-d08f0eca1c9e" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">However, this subdivision does not apply if the responsible person for the work gives a local government a remote area compliance notice for the work and the local government accepts the notice under <intref refid="sec.73" target.guid="_ac7bf15f-d59b-4d24-93dc-9262d25b096f" check="valid">section&#160;73</intref>.</txt></block></subclause></clause><clause id="sec.63" guid="_3bf1146b-c784-4ee4-bbaf-7eb7a5a1ed56" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>63</no><heading id="sec.63-he" guid="_9b1e1568-522d-4dc1-b25b-7896391ee44c">Request for work to be inspected</heading><subclause id="sec.63-ssec.1" guid="_09e675ae-5bd2-434a-acfb-6fbea7f212e2" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The responsible person for the work must make a request, complying with <intref refid="sec.63-ssec.3" target.guid="_6f6ebc67-08c7-4c57-99e8-218c1ded7d16" check="valid">subsection&#160;(3)</intref>, to the local government to inspect the work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.63-ssec.1-para1.a" guid="_966006a4-5d0a-430d-a611-f9b6c1bbdd68" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">if any part of the plumbing or drainage resulting from, or affected by, the work is to be covered—before the part is covered, subject to <intref refid="sec.63-ssec.2" target.guid="_d3ea5f8a-7ab0-4f1c-b4b1-e478e7242e70" check="valid">subsection&#160;(2)</intref>; and</txt></block></li><li id="sec.63-ssec.1-para1.b" guid="_006ba60b-9f2d-4d01-b70b-e0f745b66b67" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the work relates to a greywater use facility including a land application area—no later than 5 business days after the irrigation for the facility is installed; and </txt></block></li><li id="sec.63-ssec.1-para1.c" guid="_7abcc772-6be4-4538-8fc6-f2bf21a26c39" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">if the work is on-site sewage work for an on-site sewage facility—no later than 5 business days after all the pipes for the facility are connected; and </txt></block></li><li id="sec.63-ssec.1-para1.d" guid="_98c50632-4e89-4523-9009-9fabd4cd080d" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">if the permit includes a condition requiring an inspection at a stage of the work stated in the permit—no later than 5 business days after the stage has been reached; and </txt></block></li><li id="sec.63-ssec.1-para1.e" guid="_18cdf528-f7d5-4521-ac9a-e35cc2067c8d" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">if an inspector has given the person an action notice requiring the person to make the request—within the period stated in the notice; and </txt></block></li><li id="sec.63-ssec.1-para1.f" guid="_76fcfdd1-b80e-4374-93a7-d13fa70c9ee9" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">no later than 5 business days after the plumbing or drainage resulting from, or affected by, the work has become operational. </txt></block></li></list><penalty id="sec.63-ssec.1-pen" guid="_cb948010-c070-46f4-819f-7af0f4b17515"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause><subclause id="sec.63-ssec.2" guid="_d3ea5f8a-7ab0-4f1c-b4b1-e478e7242e70" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Drainage below ground level resulting from, or affected by, on-site sewage work may be partially covered before it is inspected if a cross-section of the drainage is left uncovered for inspection. </txt><note id="sec.63-ssec.2-note" guid="_da75d47e-496c-429d-9338-f8390667bd50" type="example"><heading id="sec.63-ssec.2-note-he" guid="_2c036dc9-c2a8-4615-aea5-679f1494cc2b">Example of drainage for <intref refid="sec.63-ssec.2" target.guid="_d3ea5f8a-7ab0-4f1c-b4b1-e478e7242e70" check="valid">subsection&#160;(2)</intref>—</heading><block><txt break.before="1">subsurface irrigation in a land application area</txt></block></note></block></subclause><subclause id="sec.63-ssec.3" guid="_6f6ebc67-08c7-4c57-99e8-218c1ded7d16" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">A request under <intref refid="sec.63-ssec.1" target.guid="_09e675ae-5bd2-434a-acfb-6fbea7f212e2" check="valid">subsection&#160;(1)</intref> may be made orally or by notice to the local government.</txt></block></subclause><subclause id="sec.63-ssec.4" guid="_ef6fb8ca-f9e3-4a8b-bef0-3795c902df0c" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0"><intref refid="sec.63-ssec.5" target.guid="_a3c2f4e6-9e58-42f8-abb4-5064ed44a53f" check="valid">Subsection&#160;(5)</intref> applies if the responsible person—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.63-ssec.4-para1.a" guid="_f0abfc15-45b2-4636-b484-8a9d81997a79" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">is not the person who applied for the permit; or</txt></block></li><li id="sec.63-ssec.4-para1.b" guid="_39ae261d-06ac-41e7-a837-423c19426e75" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">is not the last person who asked for the work to be inspected.</txt></block></li></list></block></subclause><subclause id="sec.63-ssec.5" guid="_a3c2f4e6-9e58-42f8-abb4-5064ed44a53f" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">Before the responsible person asks the local government to inspect the work, the responsible person must give the local government a notice, in the approved form, stating the responsible person’s name and contact details.</txt><penalty id="sec.63-ssec.5-pen" guid="_4ccd5ad9-b712-4f10-9c09-8d2aefd3a290"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause></clause><clause id="sec.64" guid="_6bdca0e8-8a26-4af0-ae0f-aaf35ee86b05" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>64</no><heading id="sec.64-he" guid="_77918620-997f-4b7e-9bc9-b37317227827">Inspecting work for compliance</heading><subclause id="sec.64-ssec.1" guid="_0eb64cca-bb9b-4467-a2cd-3403976ec881" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the responsible person for the work makes a request under <intref refid="sec.63" target.guid="_3bf1146b-c784-4ee4-bbaf-7eb7a5a1ed56" check="valid">section&#160;63</intref> for the local government to inspect the work.</txt></block></subclause><subclause id="sec.64-ssec.2" guid="_e4114dd6-672a-438d-9fa1-757a811ae390" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An inspector must start inspecting the work within— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.64-ssec.2-para1.a" guid="_b1b93da2-1cbc-4eb0-b89a-254de028c5f2" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">1 hour after the time agreed between the local government and the responsible person; or </txt></block></li><li id="sec.64-ssec.2-para1.b" guid="_a84a5537-236f-4b6f-a327-a4713c5a205e" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if a time is not agreed—48 hours after the responsible person asks the local government to inspect the work. </txt></block></li></list><note id="sec.64-ssec.2-note" guid="_702446dc-2999-410a-a858-7347626f848f" type="example"><heading id="sec.64-ssec.2-note-he" guid="_6248ab20-a570-4ecb-b43a-e37b66ee2401">Note—</heading><block><txt break.before="1">See <intref refid="sec.87" target.guid="_c0308790-b6d0-49e7-b0fd-24b82e73ca69" check="valid">section&#160;87</intref> for the consequences of not inspecting the work under <intref refid="sec.64-ssec.2" target.guid="_e4114dd6-672a-438d-9fa1-757a811ae390" check="valid">subsection&#160;(2)</intref>.</txt></block></note></block></subclause><subclause id="sec.64-ssec.3" guid="_e6973219-8544-4d69-a2ee-92dbcc948e56" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An inspector does not fail to comply with <intref refid="sec.64-ssec.2" target.guid="_e4114dd6-672a-438d-9fa1-757a811ae390" check="valid">subsection&#160;(2)</intref> only because the inspector can not enter the premises to which the permit relates.</txt></block></subclause><subclause id="sec.64-ssec.4" guid="_1afcffd3-45ed-426c-ae76-5e0d2b46def1" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The responsible person must give an inspector the help the inspector reasonably requires to inspect the work unless the person has a reasonable excuse. </txt></block><penalty id="sec.64-ssec.4-pen" guid="_91379b9b-94f1-4bc9-b616-37b9563fec48"><block><txt break.before="1">Maximum penalty for <intref refid="sec.64-ssec.4" target.guid="_1afcffd3-45ed-426c-ae76-5e0d2b46def1" check="valid">subsection&#160;(4)</intref>—20 penalty units.</txt></block></penalty></subclause></clause><clause id="sec.65" guid="_5c802b49-3e66-4328-9f49-ea30be98750c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>65</no><heading id="sec.65-he" guid="_d581f40d-825a-4f7f-a063-069fe2b618db">Covering plumbing and drainage</heading><subclause id="sec.65-ssec" guid="_ce50d6a3-f42d-4a14-97ff-dbbb8262d360" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">The responsible person for the work must not cover any plumbing or drainage resulting from, or affected by, the work before an inspector inspects the work, unless—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.65-ssec-para1.a" guid="_a4676a14-1c16-4c00-ba76-8029b3df7256" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">an inspector has allowed the plumbing or drainage to be covered; or</txt></block></li><li id="sec.65-ssec-para1.b" guid="_8f20c0b3-23d4-4751-8397-51f28991e97a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for work that is on-site sewage work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.65-ssec-para1.b-para2.i" guid="_173d542b-22db-49fd-9031-7fa894e61b2a" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the responsible person ensures the drainage is only partially covered under <intref refid="sec.63" target.guid="_3bf1146b-c784-4ee4-bbaf-7eb7a5a1ed56" check="valid">section&#160;63</intref><intref refid="sec.63-ssec.2" target.guid="_d3ea5f8a-7ab0-4f1c-b4b1-e478e7242e70" check="valid">(2)</intref>; or</txt></block></li><li id="sec.65-ssec-para1.b-para2.ii" guid="_899a01f7-5d61-4957-a7a9-090475e4e475" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the local government has allowed an on-site sewage work declaration to be given for the work under <intref refid="sec.69" target.guid="_3d3525f8-e70f-4f6e-80d1-1b9955cf057a" check="valid">section&#160;69</intref>.</txt></block></li></list></block></li></list></block></subclause></clause><clause id="sec.66" guid="_9dbacd92-f010-43df-914e-5c3d99d08ea6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>66</no><heading id="sec.66-he" guid="_8af2199c-a22c-436b-8180-8b0380e5e7bf">Action notice for covering plumbing or drainage</heading><subclause id="sec.66-ssec.1" guid="_8225d86d-c8f0-4784-8c9d-c6c1c4b98e02" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.66-ssec.1-para1.a" guid="_bd36a492-cd36-41fa-b208-081a27c6e983" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the responsible person covers plumbing or drainage resulting from, or affected by, the work before an inspector has inspected the work; and</txt></block></li><li id="sec.66-ssec.1-para1.b" guid="_e55377c2-036a-4d28-a706-23016e054718" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the inspector inspecting the work reasonably believes the responsible person has failed to comply with <intref refid="sec.65" target.guid="_5c802b49-3e66-4328-9f49-ea30be98750c" check="valid">section&#160;65</intref>.</txt></block></li></list></block></subclause><subclause id="sec.66-ssec.2" guid="_000578d9-2dd8-4e76-aca1-d1089a9909e3" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The inspector may give the responsible person an action notice requiring the person to take action to help the inspector assess whether the work is compliant, including, for example, any of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.66-ssec.2-para1.a" guid="_bfe6ff0a-524f-4733-af30-5b41501796b0" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">giving the local government a covered work declaration for the work;</txt></block></li><li id="sec.66-ssec.2-para1.b" guid="_fd4cfc60-33db-4528-bb22-e94c0b5b2253" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">inserting a camera into the plumbing or drainage to allow the inspector to inspect the work; </txt></block></li><li id="sec.66-ssec.2-para1.c" guid="_7e787974-d636-48df-b250-d16a1e9896bc" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">uncovering the plumbing or drainage to the extent necessary to enable the inspector to assess whether the work is compliant.</txt></block></li></list></block></subclause><subclause id="sec.66-ssec.3" guid="_f3c81ebd-373d-4744-b91b-416f97884fe1" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An action notice given under <intref refid="sec.66-ssec.2" target.guid="_000578d9-2dd8-4e76-aca1-d1089a9909e3" check="valid">subsection&#160;(2)</intref> may state different actions in relation to different parts of the work.</txt></block><note id="sec.66-ssec.3-note" guid="_5bbc3aa6-6574-42e0-a355-35627533712b" type="example"><heading id="sec.66-ssec.3-note-he" guid="_4cc6b0ad-95de-4e10-bbb4-b79449a05a49">Note—</heading><block><txt break.before="1">For general requirements for giving an action notice under <intref refid="sec.66-ssec.2" target.guid="_000578d9-2dd8-4e76-aca1-d1089a9909e3" check="valid">subsection&#160;(2)</intref>, see <intref refid="sec.97" target.guid="_ada6503c-3747-4625-bb26-7ea7999be21a" check="valid">section&#160;97</intref>.</txt></block></note></subclause></clause><clause id="sec.67" guid="_fc0a5d93-48ea-4ac0-944d-0bdad0eb54b6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>67</no><heading id="sec.67-he" guid="_d9d64add-1d1b-472a-8b76-ac2fdb1f9444">Allowing covered work declaration to be given if inspection delayed</heading><subclause id="sec.67-ssec.1" guid="_85fe0c6b-7d80-4459-b462-c2d3506d5c40" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.67-ssec.1-para1.a" guid="_4653e520-12b2-43a6-ba9c-dbb1e7def9b8" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the responsible person has asked the local government to inspect the work under <intref refid="sec.63" target.guid="_3bf1146b-c784-4ee4-bbaf-7eb7a5a1ed56" check="valid">section&#160;63</intref><intref refid="sec.63-ssec.1" target.guid="_09e675ae-5bd2-434a-acfb-6fbea7f212e2" check="valid">(1)</intref>; and</txt></block></li><li id="sec.67-ssec.1-para1.b" guid="_06c182e1-4340-44e2-9195-c8b18f068dc0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">an inspector has not started to inspect the work within the period mentioned in <intref refid="sec.64" target.guid="_6bdca0e8-8a26-4af0-ae0f-aaf35ee86b05" check="valid">section&#160;64</intref><intref refid="sec.64-ssec.2" target.guid="_e4114dd6-672a-438d-9fa1-757a811ae390" check="valid">(2)</intref><intref refid="sec.64-ssec.2-para1.a" target.guid="_b1b93da2-1cbc-4eb0-b89a-254de028c5f2" check="valid">(a)</intref> or <intref refid="sec.64-ssec.2-para1.b" target.guid="_a84a5537-236f-4b6f-a327-a4713c5a205e" check="valid">(b)</intref>; and</txt></block></li><li id="sec.67-ssec.1-para1.c" guid="_8169040e-5210-4bbd-9edd-a2faf318b4d8" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the responsible person covers plumbing or drainage resulting from, or affected by, the work before an inspector has inspected the work.</txt></block></li></list></block></subclause><subclause id="sec.67-ssec.2" guid="_ac1b6c92-0103-497d-8087-4ca76aead8bb" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Despite <intref refid="sec.64" target.guid="_6bdca0e8-8a26-4af0-ae0f-aaf35ee86b05" check="valid">section&#160;64</intref>, the local government may, instead of inspecting the work under that section, allow the responsible person to give the local government a covered work declaration for the work.</txt></block></subclause></clause></subdivision><subdivision id="pt.6-div.2-sdiv.2" guid="_64636442-fe0f-48d2-8328-52000edbdb8c" affected.by.uncommenced="0"><no>Subdivision 2</no><heading id="pt.6-div.2-sdiv.2-he" guid="_1baea99b-129c-4208-9cb8-bbb71be0bd00">Inspecting work under permit issued by public sector entity</heading><clause id="sec.68" guid="_7e363349-c83f-4c4b-9460-de26efb2de25" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>68</no><heading id="sec.68-he" guid="_41cecd51-3930-460b-9342-950bf1ac481a">Inspection of work by public sector entity or local government</heading><subclause id="sec.68-ssec.1" guid="_e39c21c3-ac84-446a-92e0-fbe3d747b24e" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies in relation to work carried out under a permit issued by a public sector entity.</txt></block></subclause><subclause id="sec.68-ssec.2" guid="_deab0164-c7e9-4f13-8888-b70c9f417bc4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The public sector entity may inspect the work or ask the local government to inspect the work. </txt></block></subclause><subclause id="sec.68-ssec.3" guid="_d1b503ab-47cf-4734-9e19-cb5046754889" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government may inspect the work if the public sector entity has asked the local government to inspect the work under <intref refid="sec.68-ssec.2" target.guid="_deab0164-c7e9-4f13-8888-b70c9f417bc4" check="valid">subsection&#160;(2)</intref>.</txt></block></subclause></clause></subdivision></division><division id="pt.6-div.3" guid="_5dfe4acd-a736-437a-aba4-8ed4579cbf4a" affected.by.uncommenced="0"><no>Division 3</no><heading id="pt.6-div.3-he" guid="_ddb10ef5-8541-4129-ae54-79174553657b">Alternatives to local government inspections</heading><subdivision id="pt.6-div.3-sdiv.1" guid="_34390b9c-71cb-486e-b427-7c7022b3bcb3" affected.by.uncommenced="0"><no>Subdivision 1</no><heading id="pt.6-div.3-sdiv.1-he" guid="_1b219d8b-7c0e-443c-833d-9a91f4ee7c26">Declarations for on-site sewage work</heading><clause id="sec.69" guid="_3d3525f8-e70f-4f6e-80d1-1b9955cf057a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>69</no><heading id="sec.69-he" guid="_821bfb66-a37a-4930-a99b-b4c4a32b1e49">Declaration that on-site sewage work is compliant</heading><subclause id="sec.69-ssec.1" guid="_82f87a8e-b72a-4493-bf6e-332f9a7e27a5" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to the extent the work carried out under a permit issued by a local government is on-site sewage work. </txt></block></subclause><subclause id="sec.69-ssec.2" guid="_ed8d9b1c-b488-466a-8513-cc321d522310" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Despite <intref refid="sec.64" target.guid="_6bdca0e8-8a26-4af0-ae0f-aaf35ee86b05" check="valid">section&#160;64</intref>, the local government may, instead of inspecting the work under that section, allow an appropriate person to give the local government a declaration in the approved form (an <defterm id="sec.69-def.onsitesewageworkdeclaration" guid="_e6232c17-8bdc-4b16-93fa-0b1ce680c1f1" type="definition">on-site sewage work declaration</defterm>), stating that the person—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.69-ssec.2-para1.a" guid="_ec7c73b1-bc31-4784-92fd-d7ec9116bad9" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">has inspected the on-site sewage work; and</txt></block></li><li id="sec.69-ssec.2-para1.b" guid="_90c11d67-5a1d-49b2-a757-2cf14eaeda27" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">is satisfied the work is compliant.</txt></block></li></list></block></subclause><subclause id="sec.69-ssec.3" guid="_b4508ad7-ac47-4316-a7f1-08348b608cf7" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section— </txt><deflist><definition id="sec.69-ssec.3-def.appropriateperson_" guid="_341400e1-247c-4dae-9b2a-643a786183c6" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.69-ssec.3-def.appropriateperson" guid="_7d411365-b82e-47b0-929d-7bbf0cb35f4e" type="definition">appropriate person</defterm> means a person, other than a person who carried out the work, who the local government considers—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.69-ssec.3-def.appropriateperson-para1.a" guid="_be067a4b-dbb5-49a0-8975-5d7ee4ee1606" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">has appropriate knowledge about the design and function of the on-site sewage facility to which the work relates; and</txt></block></li><li id="sec.69-ssec.3-def.appropriateperson-para1.b" guid="_f15e45ec-4c78-42ce-ac83-aac581694940" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">is otherwise competent to make the declaration.</txt></block></li></list></definition></deflist></block></subclause></clause></subdivision><subdivision id="pt.6-div.3-sdiv.2" guid="_32d72bed-004e-4764-b3fa-4097d9e125a0" affected.by.uncommenced="0"><no>Subdivision 2</no><heading id="pt.6-div.3-sdiv.2-he" guid="_82a2e227-6d6c-4e72-a5bb-4f9017704d44">Notices for particular work in remote areas</heading><clause id="sec.70" guid="_5a47d2ef-cc7e-48ca-a311-94b89cc5fc10" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>70</no><heading id="sec.70-he" guid="_88d14c9e-1cfa-4d7c-afaa-540710442f2e">Application of subdivision</heading><subclause id="sec.70-ssec" guid="_8ab1e763-073a-488a-8fc6-9c33d8bc6aed" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">This subdivision applies in relation to work carried out under a permit issued by a local government if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.70-ssec-para1.a" guid="_efc20a45-3353-42bd-a0bb-5428d77c8bbb" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the local government is mentioned in <intref refid="sch.7" target.guid="_f928d1e9-286a-45c8-81b8-6c9819bd258e" check="valid">schedule&#160;7</intref>; and</txt></block></li><li id="sec.70-ssec-para1.b" guid="_6819547a-a2a4-4327-a581-c0b5f98895f6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the work is carried out in an area the local government has declared to be a remote area under <intref refid="sec.71" target.guid="_82725a9f-cca8-45cb-b842-9ba9bbd56650" check="valid">section&#160;71</intref><intref refid="sec.71-ssec.1" target.guid="_6cec384f-4e2d-46ff-a74c-356f2f33bde9" check="valid">(1)</intref><intref refid="sec.71-ssec.1-para1.a" target.guid="_e74544f3-7f5f-4ce8-8b23-07adde6784a0" check="valid">(a)</intref>; and;</txt></block></li><li id="sec.70-ssec-para1.c" guid="_b979a265-06f4-4ae3-a4f6-74363b07e6ad" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the work is—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.70-ssec-para1.c-para2.i" guid="_7ec073bc-699a-483b-9520-103accd2c8da" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">permit work the local government has declared to be eligible work under <intref refid="sec.71" target.guid="_82725a9f-cca8-45cb-b842-9ba9bbd56650" check="valid">section&#160;71</intref><intref refid="sec.71-ssec.1" target.guid="_6cec384f-4e2d-46ff-a74c-356f2f33bde9" check="valid">(1)</intref><intref refid="sec.71-ssec.1-para1.b" target.guid="_e2147af9-a184-4513-9750-cb69feb33734" check="valid">(b)</intref> (<defterm id="sec.70-ssec-para1.c-def.eligiblework" guid="_45961efb-f65d-4d46-ab7d-673155f3656f" type="definition">eligible work</defterm>); or</txt></block></li><li id="sec.70-ssec-para1.c-para2.ii" guid="_a14f0887-7769-4801-822a-473283ee0e01" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">notifiable work (also <defterm id="sec.70-ssec-para1.c-def.eligiblework-oc.2" guid="_ae236377-733f-4d7c-9c85-aedbbb01c5b2" type="definition">eligible work</defterm>).</txt></block></li></list></block></li></list></block></subclause></clause><clause id="sec.71" guid="_82725a9f-cca8-45cb-b842-9ba9bbd56650" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>71</no><heading id="sec.71-he" guid="_9a40bbd1-240b-4781-a72c-3aa25ed8ac65">Local government declarations about remote areas and eligible work</heading><subclause id="sec.71-ssec.1" guid="_6cec384f-4e2d-46ff-a74c-356f2f33bde9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The local government may, by resolution—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.71-ssec.1-para1.a" guid="_e74544f3-7f5f-4ce8-8b23-07adde6784a0" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">declare part of its local government area to be a remote area because of the area’s remoteness from the local government’s public office (a <defterm id="sec.71-ssec.1-def.remoteareadeclaration" guid="_e29a91a7-9b33-441a-891a-e7df35502d3d" type="definition">remote area declaration</defterm>); and</txt></block></li><li id="sec.71-ssec.1-para1.b" guid="_e2147af9-a184-4513-9750-cb69feb33734" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">declare particular permit work carried out in a remote area to be eligible work if the local government considers the work is of a type that, even if not inspected, will not be likely to adversely affect public health or safety, or the environment. </txt></block></li></list></block></subclause><subclause id="sec.71-ssec.2" guid="_9f7c03d6-85e2-4504-bad5-79c4521ac03d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.71-ssec.2-para1.a" guid="_7cd97f5b-9b68-42e9-82ee-cb5fbc2030a2" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">publish each declaration on its website; and</txt></block></li><li id="sec.71-ssec.2-para1.b" guid="_1bf00ec3-5629-41fe-86bc-bc2e7759d999" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">give the chief executive a copy of the declaration; and</txt></block></li><li id="sec.71-ssec.2-para1.c" guid="_85351a0c-93fa-4a08-9eec-b43a4a0acd10" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">ensure the declaration may be inspected, free of charge, at the local government’s public office; and</txt></block></li><li id="sec.71-ssec.2-para1.d" guid="_48af00d4-c370-485b-be54-32181579069b" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">ensure each remote area declaration includes a map identifying the remote area.</txt></block></li></list></block></subclause></clause><clause id="sec.72" guid="_fe5e316c-039f-4b4a-9dc4-6a00936f2f68" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>72</no><heading id="sec.72-he" guid="_b8d6f65d-771d-443b-8be0-7a858b1df651">Notice that all eligible work for premises is compliant and operational</heading><subclause id="sec.72-ssec.1" guid="_2fc75c91-82da-43a4-a4c0-ff6d1fc122fc" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if all of the eligible work authorised for any or all of the premises under the permit has been carried out.</txt></block></subclause><subclause id="sec.72-ssec.2" guid="_432b1dfd-d77f-4994-aec6-531e8cdc8bd9" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The responsible person for the work must, within 10 business days after the plumbing or drainage resulting from, or affected by, the work has become operational and fit for use, give the local government a notice in the approved form (a <defterm id="sec.72-def.remoteareacompliancenotice" guid="_733e66f5-8539-49d8-a107-d4a696faf45e" type="definition">remote area compliance notice</defterm>) stating—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.72-ssec.2-para1.a" guid="_9d6d4607-16ef-4e83-8ee4-5b6fe4009054" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the work is compliant; and</txt></block></li><li id="sec.72-ssec.2-para1.b" guid="_9d193e3a-9418-400c-ae2c-5bee902fb49d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the plumbing or drainage is operational and fit for use.</txt></block></li></list><penalty id="sec.72-ssec.2-pen" guid="_8072aa5e-6333-4cea-a910-f458bfd6377f"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause><subclause id="sec.72-ssec.3" guid="_61be183b-e51a-419e-8339-9d3598211a3e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The responsible person for the work may authorise a suitably qualified person to prepare and give the remote area compliance notice for the responsible person under <intref refid="sec.72-ssec.2" target.guid="_432b1dfd-d77f-4994-aec6-531e8cdc8bd9" check="valid">subsection&#160;(2)</intref>.</txt></block></subclause></clause><clause id="sec.73" guid="_ac7bf15f-d59b-4d24-93dc-9262d25b096f" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>73</no><heading id="sec.73-he" guid="_1c911f35-4210-4d6f-be92-0080de35a71e">Acceptance of remote area compliance notice from suitably qualified person</heading><subclause id="sec.73-ssec.1" guid="_cd63ccc3-e2e7-4868-98e1-b353830fc6ee" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a suitably qualified person gives, or purports to give, a remote area compliance notice for the responsible person for work to a local government.</txt></block></subclause><subclause id="sec.73-ssec.2" guid="_06159ac3-85cb-4099-a378-45d864f58b49" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must decide to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.73-ssec.2-para1.a" guid="_9a9479a9-4741-4a43-a850-ae2632797c9c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">accept the remote area compliance notice, if the local government is satisfied the person is a suitably qualified person for giving the notice; or</txt></block></li><li id="sec.73-ssec.2-para1.b" guid="_cf71d3af-cd4d-42c2-a2b5-d53d56bbd18b" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">otherwise, refuse to accept the notice.</txt></block></li></list></block></subclause><subclause id="sec.73-ssec.3" guid="_8d64eb8c-c8a8-4da9-a464-6566dd6d6d62" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government must, within 5 business days after receiving the remote area compliance notice, give the responsible person a notice (the <defterm id="sec.73-def.decisionnotice" guid="_bb14f91f-5fec-47ca-b795-dfc644482a2f" type="definition">decision notice</defterm>) stating whether the local government has accepted or refused to accept the notice.</txt></block></subclause><subclause id="sec.73-ssec.4" guid="_1509df50-f1c8-471e-b3e5-d428ba6c1bf6" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the local government refuses to accept the remote area compliance notice, the local government must ensure the decision notice includes, or is accompanied by, an information notice about the decision.</txt></block></subclause><subclause id="sec.73-ssec.5" guid="_b6cf43ff-70cd-413a-b336-3aeeea45ab63" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">The local government is taken to have decided to refuse to accept the remote area compliance notice if the local government does not give the responsible person a decision notice within the period required under <intref refid="sec.73-ssec.3" target.guid="_8d64eb8c-c8a8-4da9-a464-6566dd6d6d62" check="valid">subsection&#160;(3)</intref>.</txt></block></subclause><subclause id="sec.73-ssec.6" guid="_8cc49abd-fb22-4c4f-99b7-bacb253f7b79" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">If, under <intref refid="sec.73-ssec.5" target.guid="_b6cf43ff-70cd-413a-b336-3aeeea45ab63" check="valid">subsection&#160;(5)</intref>, the local government is taken to have decided to refuse to accept the remote area compliance notice, the responsible person is entitled to be given an information notice about the decision.</txt><note id="sec.73-ssec.6-note" guid="_d6e1439f-6973-4a32-b54f-6f72235dca3f" type="example"><heading id="sec.73-ssec.6-note-he" guid="_0669abdd-a666-4068-ab0e-de3e64835c5c">Note—</heading><block><txt break.before="1">For an appeal against a decision mentioned in <intref refid="sec.73-ssec.2" target.guid="_06159ac3-85cb-4099-a378-45d864f58b49" check="valid">subsection&#160;(2)</intref><intref refid="sec.73-ssec.2-para1.b" target.guid="_cf71d3af-cd4d-42c2-a2b5-d53d56bbd18b" check="valid">(b)</intref> or <intref refid="sec.73-ssec.5" target.guid="_b6cf43ff-70cd-413a-b336-3aeeea45ab63" check="valid">(5)</intref>, see the <legref jurisd="QLD" type="act" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" check="valid"><name emphasis="yes">Planning Act 2016</name></legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_b27e6fb3-817d-489b-ba9f-f87df89be113" check="valid">schedule&#160;1</legref>, <legref jurisd="QLD" type="act" refid="sch.1-sec.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_e79cbd63-ba5c-415b-bc7d-9217dd599138" check="valid">section&#160;1</legref>, table 3, items 3 and 5.</txt></block></note></block></subclause><subclause id="sec.73-ssec.7" guid="_2566bfbc-d9d6-4af7-a0f8-0389dd023bdb" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.73-ssec.7-def.suitablyqualifiedperson_" guid="_607146a1-c515-4c5b-ae1e-ee063e03432a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.73-ssec.7-def.suitablyqualifiedperson" guid="_31b05e55-73f9-40bc-94c6-821f7c9846ed" type="definition">suitably qualified person</defterm> includes a person who purports to be a suitably qualified person.</txt></definition></deflist></block></subclause></clause></subdivision></division><division id="pt.6-div.4" guid="_01030a17-1ac8-4cec-8a9d-03f44240280d" affected.by.uncommenced="0"><no>Division 4</no><heading id="pt.6-div.4-he" guid="_040e6068-3e9a-4741-8f70-11f6daeb7885">Assessment and compliance procedures</heading><subdivision id="pt.6-div.4-sdiv.1" guid="_950beed2-36b3-4f2a-a0e3-be6db445ecb6" affected.by.uncommenced="0"><no>Subdivision 1</no><heading id="pt.6-div.4-sdiv.1-he" guid="_ac077e68-2163-47ea-be3d-c3cf75b62605">Preliminary</heading><clause id="sec.74" guid="_8a24b52c-f275-494e-a67d-1309175d4d58" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>74</no><heading id="sec.74-he" guid="_b17935a0-6da4-475b-8ecf-ab5e4ce7a4be">Application of division</heading><block><txt break.before="1">This division applies in relation to work carried out under a permit issued by a local government. </txt></block></clause></subdivision><subdivision id="pt.6-div.4-sdiv.2" guid="_e5a9fb4e-cbf5-4806-b2c1-2e41121c5ff6" affected.by.uncommenced="0"><no>Subdivision 2</no><heading id="pt.6-div.4-sdiv.2-he" guid="_d2426b2e-d38d-46b2-af3e-c98241ec1c59">Minor plan amendments</heading><clause id="sec.75" guid="_b2564d33-2845-432b-9d2e-b6f3e6db935c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>75</no><heading id="sec.75-he" guid="_c42dcebb-61cd-4fd8-9940-3fb64b59f8d9">Amending approved plan with minor inconsistency to represent work carried out</heading><subclause id="sec.75-ssec.1" guid="_9d288f8c-fa71-475a-8481-897d854a5097" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the local government considers—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.75-ssec.1-para1.a" guid="_5c3960d6-63de-41e5-ad5a-cf4fa7e49070" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the work carried out under the permit is not correctly represented in an approved plan for the work because of a minor inconsistency between the plan and the work; and</txt></block></li><li id="sec.75-ssec.1-para1.b" guid="_7b070bfa-5a49-4eb1-a3b2-c12b22389208" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">other than for <intref refid="sec.75-ssec.1-para1.a" target.guid="_5c3960d6-63de-41e5-ad5a-cf4fa7e49070" check="valid">paragraph&#160;(a)</intref>, the work carried out under the permit is compliant.</txt></block></li></list></block></subclause><subclause id="sec.75-ssec.2" guid="_73364553-a0f7-4963-a8b3-1378d8a1b6bf" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may amend the approved plan so the plan correctly represents the work carried out under the permit.</txt></block></subclause></clause></subdivision><subdivision id="pt.6-div.4-sdiv.3" guid="_f9c817d5-c771-4892-b000-f9dd9dd5d670" affected.by.uncommenced="0"><no>Subdivision 3</no><heading id="pt.6-div.4-sdiv.3-he" guid="_22d7ce72-ac7c-4a14-a847-1805e616409a">Testing or commissioning plumbing or drainage</heading><clause id="sec.76" guid="_fd7c6ca7-3143-4d8a-b7cf-41088ab08e95" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>76</no><heading id="sec.76-he" guid="_f8eaa210-97a6-48a8-a8a9-a920d2306076">Requirement to test or commission plumbing or drainage</heading><subclause id="sec.76-ssec.1" guid="_0fba18b9-0bba-43df-9ed0-86413564ddab" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An inspector may require the responsible person for the work to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.76-ssec.1-para1.a" guid="_51ed4844-93ed-4e81-b641-cc0680b6296a" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">test or commission plumbing or drainage resulting from, or affected by, the work in the inspector’s presence; or</txt></block></li><li id="sec.76-ssec.1-para1.b" guid="_f4a91156-8384-4966-806b-470d24110e7f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">ensure another licensee carries out the testing or commissioning in the inspector’s presence; or </txt></block></li><li id="sec.76-ssec.1-para1.c" guid="_fbcdf347-487f-433b-a7a3-b2f9a0787580" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">ensure a competent person carries out the testing or commissioning, without an inspector being present, within 10 business days after the requirement is made.</txt></block></li></list></block></subclause><subclause id="sec.76-ssec.2" guid="_fb807dc2-085f-4772-a765-f7a636a5be08" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The person testing or commissioning plumbing or drainage under <intref refid="sec.76-ssec.1" target.guid="_0fba18b9-0bba-43df-9ed0-86413564ddab" check="valid">subsection&#160;(1)</intref> must carry out the testing or commissioning in compliance with the code requirements for testing or commissioning the work.</txt></block></subclause><subclause id="sec.76-ssec.3" guid="_ea6dafe9-159b-4d99-911c-57adf1c0dbf7" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.76-ssec.3-def.competentperson_" guid="_1a798c86-cf6a-47a3-b891-89e7b917857c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.76-ssec.3-def.competentperson" guid="_82f5e363-7ad3-4add-9dcc-4d73c0a07fa8" type="definition">competent person</defterm> means a person—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.76-ssec.3-def.competentperson-para1.a" guid="_e0dea024-f792-4853-9358-83be13396e61" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">who holds a licence authorising the person to carry out the testing or commissioning; or</txt></block></li><li id="sec.76-ssec.3-def.competentperson-para1.b" guid="_8b831ca7-286a-4c00-9efa-608dc5c89bde" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">whom the local government considers is competent to carry out the testing or commissioning.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.77" guid="_d8bdf619-d142-4764-8f75-6d2d1de009b3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>77</no><heading id="sec.77-he" guid="_a0bd37bb-5987-4e94-82a6-eeb446eb4ff5">Requirement for testing or commissioning report</heading><subclause id="sec.77-ssec.1" guid="_2e4309a5-ed73-4d7f-889c-e1aa669381ec" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.77-ssec.1-para1.a" guid="_c3ab38dd-7fe4-4cc1-9d1e-148bae4ac71d" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">an inspector requires the responsible person for the work to ensure a competent person tests or commissions plumbing or drainage under <intref refid="sec.76" target.guid="_fd7c6ca7-3143-4d8a-b7cf-41088ab08e95" check="valid">section&#160;76</intref><intref refid="sec.76-ssec.1" target.guid="_0fba18b9-0bba-43df-9ed0-86413564ddab" check="valid">(1)</intref><intref refid="sec.76-ssec.1-para1.c" target.guid="_fbcdf347-487f-433b-a7a3-b2f9a0787580" check="valid">(c)</intref> or an action notice; and</txt></block></li><li id="sec.77-ssec.1-para1.b" guid="_16b6faa6-281a-4c9d-84f7-dcba01f13614" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the competent person carries out the testing or commissioning.</txt></block></li></list></block></subclause><subclause id="sec.77-ssec.2" guid="_048ffa50-b7d6-4618-b5bd-fab029ebc951" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The competent person must prepare and sign a report in the approved form (a <defterm id="sec.77-def.testingorcommissioningreport" guid="_babe496e-0046-4a7b-aa80-b588ab6a3919" type="definition">testing or commissioning report</defterm>) stating—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.77-ssec.2-para1.a" guid="_0ec3341d-9e79-4bdf-9ac4-4679d1a32fbf" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">that the person tested or commissioned the plumbing or drainage; and</txt></block></li><li id="sec.77-ssec.2-para1.b" guid="_7086eaf6-c96f-4c33-9321-900eeb0300fc" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">that the plumbing or drainage was tested or commissioned in compliance with the code requirements for testing or commissioning the work; and</txt></block></li><li id="sec.77-ssec.2-para1.c" guid="_903c9148-af2e-4586-8275-9e769b06f736" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">whether the work relating to the plumbing or drainage complies with the code requirements for the work; and</txt></block></li><li id="sec.77-ssec.2-para1.d" guid="_8fb62f90-a741-4570-b71f-2868b14359bc" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">if the work relating to the plumbing or drainage does not comply with the code requirements for the work—how the work does not so comply.</txt></block></li></list></block><penalty id="sec.77-ssec.2-pen" guid="_eb5d1156-bc50-4f95-8d5f-0aad331220af"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.77-ssec.3" guid="_0f0968a9-2fcd-4fd4-b6a3-1c948c231a0b" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The competent person must give the testing or commissioning report to the responsible person within 5 business days after the testing or commissioning is finished.</txt></block><penalty id="sec.77-ssec.3-pen" guid="_8d02a314-82a6-42ce-89cd-0d03ac6f6a90"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.77-ssec.4" guid="_cc92ec29-770b-4537-8fe6-99c3da8f9843" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the responsible person is given a testing or commissioning report under <intref refid="sec.77-ssec.3" target.guid="_0f0968a9-2fcd-4fd4-b6a3-1c948c231a0b" check="valid">subsection&#160;(3)</intref>, the responsible person must give the report to the local government within—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.77-ssec.4-para1.a" guid="_2e4a7568-de6a-4ef4-9929-35b35b7e0009" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">10 business days after the testing or commissioning is finished; or</txt></block></li><li id="sec.77-ssec.4-para1.b" guid="_47256191-77aa-4b54-986f-f649bd9dd930" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if before the end of the 10 business days, the local government decides the report may be given within a longer period—the longer period. </txt></block></li></list></block><penalty id="sec.77-ssec.4-pen" guid="_9c3ce4d4-e05f-4f10-acd3-b2c92c25e220"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause></clause></subdivision><subdivision id="pt.6-div.4-sdiv.4" guid="_6ae2658e-b42c-4c96-b52a-c4b5924ad615" affected.by.uncommenced="0"><no>Subdivision 4</no><heading id="pt.6-div.4-sdiv.4-he" guid="_8e937549-7dc2-4334-8c97-55a32a7b6b7d">Giving action notices</heading><clause id="sec.78" guid="_826c0010-cc77-44d8-9195-d8313bf0d62e" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>78</no><heading id="sec.78-he" guid="_a8dcaa91-f113-4710-932d-92fcc411de3f">Criteria for giving action notice for work </heading><subclause id="sec.78-ssec" guid="_cfa434a7-b25c-4d47-8f7b-3463ff3c0cd7" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">An inspector may give an action notice to the responsible person for the work (the <defterm id="sec.78-def.relevantwork" guid="_54c56cef-8805-411d-9bbd-bf0636a7ffc2" type="definition">relevant work</defterm>) carried out under the permit if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.78-ssec-para1.a" guid="_9da241c3-a0ad-4634-8d36-64de52fc7927" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the inspector has inspected the relevant work and is not satisfied the work is compliant; or</txt><note id="sec.78-ssec-para1.a-note" guid="_7d65b19f-f91a-4a27-9c80-b85487d3b2a7" type="example"><heading id="sec.78-ssec-para1.a-note-he" guid="_ac5e0ab8-f480-4310-b805-6c5a45d55bdd">Examples of reasons an inspector may not be satisfied work is compliant—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.78-ssec-para1.a-note-para2" guid="_b87d1963-e93b-4559-be7e-ddfd8d3df9ea" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">the work has been covered before the inspector has inspected it</txt></block></li><li id="sec.78-ssec-para1.a-note-para2-oc.2" guid="_68eac3c1-791d-4f17-91ca-c8e26a2773ea" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">the inspector requires further information about whether or not a thing that is part of the work is a thing to which <legref jurisd="QLD" type="act" refid="sec.65" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b4d29d10-8405-451e-a13b-3b5ec933e3b5" check="valid">section&#160;65</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref><legref jurisd="QLD" type="act" check="invalid">(a)</legref> to <legref jurisd="QLD" type="act" check="invalid">(f)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref> applies</txt></block></li></list></block></note></block></li><li id="sec.78-ssec-para1.b" guid="_770547d9-23c9-4a27-88f8-78be32440c93" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the inspector has inspected the relevant work and considers there is a substantial inconsistency between the work and the permit or an approved plan for the work; or</txt><note id="sec.78-ssec-para1.b-note" guid="_216c2e82-1ebb-4e1e-a0df-3056d3f9530e" type="example"><heading id="sec.78-ssec-para1.b-note-he" guid="_1f5bd43c-f496-4bd8-87f4-27b99334b614">Example for <intref refid="sec.78-ssec-para1.b" target.guid="_770547d9-23c9-4a27-88f8-78be32440c93" check="valid">paragraph&#160;(b)</intref>—</heading><block><txt break.before="1">The local government dealt with the application for the permit as a fast-track application and the inspector considers the relevant work includes permit work that is not fast-track permit work.</txt></block></note></block></li><li id="sec.78-ssec-para1.c" guid="_358086b9-71af-4697-aee1-aecaf2eeeb6e" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the inspector has, under <intref refid="sec.76" target.guid="_fd7c6ca7-3143-4d8a-b7cf-41088ab08e95" check="valid">section&#160;76</intref><intref refid="sec.76-ssec.1" target.guid="_0fba18b9-0bba-43df-9ed0-86413564ddab" check="valid">(1)</intref><intref refid="sec.76-ssec.1-para1.c" target.guid="_fbcdf347-487f-433b-a7a3-b2f9a0787580" check="valid">(c)</intref>, required the responsible person to ensure a competent person tests or commissions plumbing or drainage resulting from, or affected by, the relevant work and either of the following applies—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.78-ssec-para1.c-para2.i" guid="_577ef350-9825-4497-9b71-bd030db11b61" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the inspector considers the responsible person has contravened <intref refid="sec.77" target.guid="_d8bdf619-d142-4764-8f75-6d2d1de009b3" check="valid">section&#160;77</intref><intref refid="sec.77-ssec.4" target.guid="_cc92ec29-770b-4537-8fe6-99c3da8f9843" check="valid">(4)</intref>;</txt></block></li><li id="sec.78-ssec-para1.c-para2.ii" guid="_26a159be-6f6c-4c1b-a26f-0f611f44c2cf" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the testing or commissioning report prepared by the competent person states that the work, or part of the work, does not comply with the code requirements for the work. </txt></block></li></list></block></li></list></block></subclause></clause><clause id="sec.79" guid="_2cce5251-276b-43ef-8faf-a60c35f7cd98" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>79</no><heading id="sec.79-he" guid="_0531499d-2ab7-4a66-b0fd-423b8ac61f38">Requirements for action notice</heading><subclause id="sec.79-ssec.1" guid="_3718a263-7eae-4b71-99ea-9f6856a2862b" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">If the inspector decides to give an action notice under <intref refid="sec.78" target.guid="_826c0010-cc77-44d8-9195-d8313bf0d62e" check="valid">section&#160;78</intref><intref refid="sec.78-para1.a" check="invalid">(a)</intref> or <intref refid="sec.78-para1.b" check="invalid">(b)</intref>, the inspector must give the notice within 2 business days after carrying out the inspection.</txt></block></subclause><subclause id="sec.79-ssec.2" guid="_ffecd80c-f48a-47ba-9f9c-84a47c923924" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An action notice given under <intref refid="sec.78" target.guid="_826c0010-cc77-44d8-9195-d8313bf0d62e" check="valid">section&#160;78</intref><intref refid="sec.78-para1.a" check="invalid">(a)</intref> may require the responsible person to take stated action, including, for example—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.79-ssec.2-para1.a" guid="_76eeac3b-e141-4790-b373-56ef0d234a19" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">carrying out stated work; and</txt></block></li><li id="sec.79-ssec.2-para1.b" guid="_2b015efc-16db-430f-8139-f8b0aa7f81c8" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">requesting, within a stated period, a further inspection of any work required to be carried out under the notice; and</txt></block></li><li id="sec.79-ssec.2-para1.c" guid="_ee342d82-32cf-4d95-8a4c-98931d7d8aee" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">giving the local government a declaration in the approved form that stated work is compliant; and</txt></block></li><li id="sec.79-ssec.2-para1.d" guid="_ee653a47-8f64-448c-9769-7cce93a53cc7" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">giving the local government particular information about the relevant work, including, for example, information about whether or not a thing that is part of the work is a thing to which <legref jurisd="QLD" type="act" refid="sec.65" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b4d29d10-8405-451e-a13b-3b5ec933e3b5" check="valid">section&#160;65</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref><legref jurisd="QLD" type="act" check="invalid">(a)</legref> to <legref jurisd="QLD" type="act" check="invalid">(f)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref> applies; and</txt></block></li><li id="sec.79-ssec.2-para1.e" guid="_9e598a7f-2b69-4cd7-bb38-9e09c86d52d1" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">arranging for the testing or commissioning of plumbing or drainage resulting from, or affected by, the relevant work in the way mentioned in <intref refid="sec.76" target.guid="_fd7c6ca7-3143-4d8a-b7cf-41088ab08e95" check="valid">section&#160;76</intref><intref refid="sec.76-ssec.1" target.guid="_0fba18b9-0bba-43df-9ed0-86413564ddab" check="valid">(1)</intref><intref refid="sec.76-ssec.1-para1.a" target.guid="_51ed4844-93ed-4e81-b641-cc0680b6296a" check="valid">(a)</intref>, <intref refid="sec.76-ssec.1-para1.b" target.guid="_f4a91156-8384-4966-806b-470d24110e7f" check="valid">(b)</intref> or <intref refid="sec.76-ssec.1-para1.c" target.guid="_fbcdf347-487f-433b-a7a3-b2f9a0787580" check="valid">(c)</intref> or in another way.</txt></block></li></list></block></subclause><subclause id="sec.79-ssec.3" guid="_d0dd2b6a-afdd-4824-af57-b7123802b2f5" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An action notice given under <intref refid="sec.78" target.guid="_826c0010-cc77-44d8-9195-d8313bf0d62e" check="valid">section&#160;78</intref><intref refid="sec.78-para1.b" check="invalid">(b)</intref> may require the responsible person to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.79-ssec.3-para1.a" guid="_f630fb9f-2093-4e40-bda8-fc8f35a5ffe8" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">do all of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.79-ssec.3-para1.a-para2.i" guid="_73be0eab-3356-48df-bded-e6c506f083a4" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">stop carrying out stated work;</txt></block></li><li id="sec.79-ssec.3-para1.a-para2.ii" guid="_dc9b8ed4-329e-4020-a3db-40e97fee2e9b" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">apply, under <intref refid="pt.5" target.guid="_357246d4-1e65-48ec-b9a7-5400c77d68d5" check="valid">part&#160;5</intref>, <intref refid="pt.5-div.2" target.guid="_739f64a2-5458-4cb7-aab6-900e306592c7" check="valid">division&#160;2</intref>, to amend the permit to authorise stated work;</txt></block></li><li id="sec.79-ssec.3-para1.a-para2.iii" guid="_4ef0378f-8c9f-4a8a-b9ac-3d535120a6be" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">ensure no further work of a stated type is carried out unless the permit is amended as mentioned in <intref refid="sec.79-ssec.3-para1.a-para2.ii" target.guid="_dc9b8ed4-329e-4020-a3db-40e97fee2e9b" check="valid">subparagraph&#160;(ii)</intref>; or</txt></block></li></list></block></li><li id="sec.79-ssec.3-para1.b" guid="_d1bf4c7b-e76c-4ce2-ab03-ee9674d2ddb2" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">give the local government, within a stated period or at a stated stage of the work, an as-constructed drawing that correctly represents the relevant work.</txt></block></li></list></block></subclause><subclause id="sec.79-ssec.4" guid="_55b29349-86bc-4c59-bd12-a3c6b413ed5e" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">An action notice given under <intref refid="sec.78" target.guid="_826c0010-cc77-44d8-9195-d8313bf0d62e" check="valid">section&#160;78</intref><intref refid="sec.78-para1.c" check="invalid">(c)</intref> may require the responsible person to arrange for the further testing or commissioning of plumbing or drainage resulting from, or affected by, the relevant work in the way mentioned in <intref refid="sec.76" target.guid="_fd7c6ca7-3143-4d8a-b7cf-41088ab08e95" check="valid">section&#160;76</intref><intref refid="sec.76-ssec.1" target.guid="_0fba18b9-0bba-43df-9ed0-86413564ddab" check="valid">(1)</intref><intref refid="sec.76-ssec.1-para1.c" target.guid="_fbcdf347-487f-433b-a7a3-b2f9a0787580" check="valid">(c)</intref> or in another way.</txt></block></subclause><note id="sec.79-note" guid="_75f0daec-5a37-4cf9-b49f-2a3a51ecefbb" type="example"><heading id="sec.79-note-he" guid="_1ade58d6-b00d-4bae-9340-39c65aeaf668">Note—</heading><block><txt break.before="1">For the general requirements for the form and content of an action notice, see <intref refid="sec.97" target.guid="_ada6503c-3747-4625-bb26-7ea7999be21a" check="valid">section&#160;97</intref>.</txt></block></note></clause></subdivision></division><division id="pt.6-div.5" guid="_8b9e006d-30a2-4e56-8dc5-4f0a173cddc8" affected.by.uncommenced="0"><no>Division 5</no><heading id="pt.6-div.5-he" guid="_f30231fa-0373-47e2-a081-28e39912bfbf">Inspection and final inspection certificates</heading><subdivision id="pt.6-div.5-sdiv.1" guid="_d5b47120-a3fb-4465-91d6-1b807cbf6d44" affected.by.uncommenced="0"><no>Subdivision 1</no><heading id="pt.6-div.5-sdiv.1-he" guid="_5a04a6cd-ac7d-4293-b72b-8a200be590ac">Preliminary</heading><clause id="sec.80" guid="_31fb489b-e621-4ce2-a96f-3d9514544936" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>80</no><heading id="sec.80-he" guid="_f63243e9-1977-4157-a4e0-fec4707973a4">Inspection certificate—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8aab3043-2ec8-4212-9668-30868d83324c" check="valid">sch&#160;1</legref></heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8aab3043-2ec8-4212-9668-30868d83324c" check="valid">schedule&#160;1</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, definition <defterm guid="_31ab3100-1b9a-4b1e-b0ee-a14900780798" type="mention">inspection certificate</defterm>, an inspection certificate is a certificate, in the approved form—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.80-para1.a" guid="_961d6c39-19ed-4d97-88a9-d84ede510810" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">given by a local government or a public sector entity about work authorised under a permit issued by the local government or entity; and</txt></block></li><li id="sec.80-para1.b" guid="_fc03ea65-0b95-4b4c-baa3-788da7a8c022" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">certifying—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.80-para1.b-para2.i" guid="_a67c11b9-2429-47d7-9e06-4d5bf7c7378a" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">that a particular part of the work has been carried out; and</txt></block></li><li id="sec.80-para1.b-para2.ii" guid="_38d3c8e1-a3c4-4acb-a9d1-93c067626943" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the work that has been carried out is compliant; and</txt></block></li><li id="sec.80-para1.b-para2.iii" guid="_129e2990-e7bb-4e01-8f6b-37825c99a1ad" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">if, when the certificate is given, any plumbing or drainage resulting from, or affected by, the work is operational and fit for use—the plumbing or drainage is operational and fit for use.</txt></block></li></list></block></li></list></block></clause><clause id="sec.81" guid="_753266db-e13d-4703-85ee-bb8650c53efb" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>81</no><heading id="sec.81-he" guid="_f638bd44-46c0-483b-9843-da571baa29df">Final inspection certificate—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8aab3043-2ec8-4212-9668-30868d83324c" check="valid">sch&#160;1</legref></heading><subclause id="sec.81-ssec.1" guid="_583cd2d6-a0b5-45f2-8793-38e54af3c28a" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8aab3043-2ec8-4212-9668-30868d83324c" check="valid">schedule&#160;1</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, definition <defterm guid="_f5727dec-3d04-4a65-a5c8-3661dfb89662" type="mention">final inspection certificate</defterm>, a final inspection certificate is a certificate, in the approved form—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.81-ssec.1-para1.a" guid="_f5ab4128-62d3-4d1b-938e-9b7c583d240c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">given by a local government or a public sector entity about work authorised under a permit issued by the local government or entity; and</txt></block></li><li id="sec.81-ssec.1-para1.b" guid="_269a476f-57ad-4d5e-90cf-2b1d139c4a8d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">certifying that the following work has been carried out—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.81-ssec.1-para1.b-para2.i" guid="_d93893b2-88ee-4243-a8b1-cb93ab9983a4" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">for work authorised under a permit for only 1 premises—all of the work;</txt></block></li><li id="sec.81-ssec.1-para1.b-para2.ii" guid="_4dc693ed-20da-468a-bca7-a0b3537d5d35" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">for work authorised under a permit for 2 or more premises—all of the work for 1 or more of the premises; and </txt></block></li></list></block></li><li id="sec.81-ssec.1-para1.c" guid="_7c054eec-efb0-401e-8127-7b091757ca5d" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">certifying—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.81-ssec.1-para1.c-para2.i" guid="_35944da0-22ca-46b3-8673-6742c53f4d5a" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the work that has been carried out is compliant; and</txt></block></li><li id="sec.81-ssec.1-para1.c-para2.ii" guid="_d79cf960-6b2f-4e95-87df-50bf980cc6e1" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the plumbing or drainage resulting from, or affected by, the work is operational and fit for use.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.81-ssec.2" guid="_756b6c0e-45b0-42ab-9f44-733832a5c328" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If a final inspection certificate is given under <intref refid="sec.81-ssec.1" target.guid="_583cd2d6-a0b5-45f2-8793-38e54af3c28a" check="valid">subsection&#160;(1)</intref><intref refid="sec.81-ssec.1-para1.b" target.guid="_269a476f-57ad-4d5e-90cf-2b1d139c4a8d" check="valid">(b)</intref><intref refid="sec.81-ssec.1-para1.b-para2.ii" target.guid="_4dc693ed-20da-468a-bca7-a0b3537d5d35" check="valid">(ii)</intref> for work authorised under the permit for some but not all of the premises, a later final inspection certificate may relate only to work for premises for which a final inspection certificate has not already been given.</txt></block></subclause><subclause id="sec.81-ssec.3" guid="_ddd60c60-c1b8-406d-a731-ff6fa1f013e8" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">This section applies in relation to work carried out under the permit for premises whether or not an inspection certificate has already been given for part of the work.</txt></block></subclause></clause></subdivision><subdivision id="pt.6-div.5-sdiv.2" guid="_865f5354-2b48-4885-afad-2b0c406ce4d5" affected.by.uncommenced="0"><no>Subdivision 2</no><heading id="pt.6-div.5-sdiv.2-he" guid="_0209bab4-0374-4a99-886d-5381c8d39f51">Certificates given by local government</heading><clause id="sec.82" guid="_fe997ebd-6595-4061-aa8c-9e40ab3fdca5" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>82</no><heading id="sec.82-he" guid="_3e70bf24-b369-46fd-bddb-72f327fceb2b">Application of subdivision</heading><block><txt break.before="1">This subdivision applies in relation to work carried out under a permit issued by a local government.</txt></block></clause><clause id="sec.83" guid="_0ebb817f-7bb2-40a7-a6d2-5c3b7c18b1b8" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>83</no><heading id="sec.83-he" guid="_07eae598-e340-4045-a612-184c6807180e">Local government giving inspection certificate for work</heading><subclause id="sec.83-ssec.1" guid="_b0f995e4-8efc-42a9-9d91-d7aee7dad3d0" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The local government must give an inspection certificate for the work to the responsible person for the work if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.83-ssec.1-para1.a" guid="_b9ed7a73-8008-4f04-b474-9c02a0ba22a9" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the person makes a written request to the local government for an inspection certificate for the work; and</txt></block></li><li id="sec.83-ssec.1-para1.b" guid="_6a9af3eb-cdb5-4369-b2aa-5f2b5e095439" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the work comprises only part of the work authorised to be carried out under the permit for premises; and</txt></block></li><li id="sec.83-ssec.1-para1.c" guid="_dc395425-269a-41e9-83dd-4364e9784658" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">any of the following applies—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.83-ssec.1-para1.c-para2.i" guid="_793e1673-10b3-4ca3-9e32-15006e77f166" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">an inspector for the local government has inspected the work and the local government is satisfied the work is compliant; </txt></block></li><li id="sec.83-ssec.1-para1.c-para2.ii" guid="_f1dee9d6-7ea1-46d2-ac27-e37eb73e8e9b" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the local government has been given a covered work declaration for the work under <intref refid="sec.66" target.guid="_9dbacd92-f010-43df-914e-5c3d99d08ea6" check="valid">section&#160;66</intref><intref refid="sec.66-ssec.2" target.guid="_000578d9-2dd8-4e76-aca1-d1089a9909e3" check="valid">(2)</intref><intref refid="sec.66-ssec.2-para1.a" target.guid="_bfe6ff0a-524f-4733-af30-5b41501796b0" check="valid">(a)</intref> or <intref refid="sec.67" target.guid="_fc0a5d93-48ea-4ac0-944d-0bdad0eb54b6" check="valid">67</intref><intref refid="sec.67-ssec.2" target.guid="_ac1b6c92-0103-497d-8087-4ca76aead8bb" check="valid">(2)</intref>;</txt></block></li><li id="sec.83-ssec.1-para1.c-para2.iii" guid="_6f8df70d-259e-4bdf-a182-3d43ed79e97f" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">the local government has been given an on-site sewage work declaration for the work under <intref refid="sec.69" target.guid="_3d3525f8-e70f-4f6e-80d1-1b9955cf057a" check="valid">section&#160;69</intref><intref refid="sec.69-ssec.2" target.guid="_ed8d9b1c-b488-466a-8513-cc321d522310" check="valid">(2)</intref>.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.83-ssec.2" guid="_4d97b053-c175-4568-856d-501a203c79ad" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0"><intref refid="sec.83-ssec.1" target.guid="_b0f995e4-8efc-42a9-9d91-d7aee7dad3d0" check="valid">Subsection&#160;(1)</intref> is subject to <intref refid="sec.85" target.guid="_864476b2-5244-4d68-968d-9970708a9e32" check="valid">section&#160;85</intref>.</txt></block></subclause><subclause id="sec.83-ssec.3" guid="_7bc5fe6c-d7be-4030-9e2c-87f53088423b" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government must give the certificate within 2 business days after the following day—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.83-ssec.3-para1.a" guid="_4dec53cd-05ec-4244-82ba-5f816eecb54b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">if the work has been inspected and <intref refid="sec.83-ssec.1" target.guid="_b0f995e4-8efc-42a9-9d91-d7aee7dad3d0" check="valid">subsection&#160;(1)</intref><intref refid="sec.83-ssec.1-para1.c" target.guid="_dc395425-269a-41e9-83dd-4364e9784658" check="valid">(c)</intref><intref refid="sec.83-ssec.1-para1.c-para2.i" target.guid="_793e1673-10b3-4ca3-9e32-15006e77f166" check="valid">(i)</intref> applies—the day the work was inspected;</txt></block></li><li id="sec.83-ssec.3-para1.b" guid="_a63a1ea4-f47f-40f6-a8c1-ebd461392bd1" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the local government has been given a covered work declaration or on-site sewage work declaration for the work—the day the declaration was given. </txt></block></li></list></block></subclause></clause><clause id="sec.84" guid="_ba2f803c-0b30-469f-9786-f586c6ff1e24" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>84</no><heading id="sec.84-he" guid="_ab4dfa9e-4c08-4f56-b803-d5c5fa045d82">Local government giving final inspection certificate for work</heading><subclause id="sec.84-ssec.1" guid="_6a222a04-8657-41c7-90b6-932698868cd9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The local government must give a final inspection certificate for the work to the responsible person for the work if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.84-ssec.1-para1.a" guid="_cf5a8aa9-0b54-4e52-885e-6000e130f00b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the work comprises—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.84-ssec.1-para1.a-para2.i" guid="_26b9b124-a2e8-43ad-9994-142a63535921" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">all of the work authorised to be carried out under the permit; or</txt></block></li><li id="sec.84-ssec.1-para1.a-para2.ii" guid="_83bebf30-e7f0-4934-8a6d-457bb6680e3c" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">for a permit authorising work to be carried out for 2 or more premises—all of the work authorised to be carried out under the permit for 1 or more of the premises; and</txt></block></li></list></block></li><li id="sec.84-ssec.1-para1.b" guid="_33e37ca7-a1d0-4f94-a0a6-1d706f240f5d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">any of the following applies—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.84-ssec.1-para1.b-para2.i" guid="_74f894ee-0d28-4a37-8800-d547a9e98c0f" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">an inspector for the local government has inspected the work and the local government is satisfied the work is compliant; </txt></block></li><li id="sec.84-ssec.1-para1.b-para2.ii" guid="_9e8cfa9d-74fd-403a-81ae-ebd28989dccd" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the local government has been given a covered work declaration for the work under <intref refid="sec.66" target.guid="_9dbacd92-f010-43df-914e-5c3d99d08ea6" check="valid">section&#160;66</intref><intref refid="sec.66-ssec.2" target.guid="_000578d9-2dd8-4e76-aca1-d1089a9909e3" check="valid">(2)</intref><intref refid="sec.66-ssec.2-para1.a" target.guid="_bfe6ff0a-524f-4733-af30-5b41501796b0" check="valid">(a)</intref> or <intref refid="sec.67" target.guid="_fc0a5d93-48ea-4ac0-944d-0bdad0eb54b6" check="valid">67</intref><intref refid="sec.67-ssec.2" target.guid="_ac1b6c92-0103-497d-8087-4ca76aead8bb" check="valid">(2)</intref>;</txt></block></li><li id="sec.84-ssec.1-para1.b-para2.iii" guid="_ddb88756-52f4-4848-8141-cb1f165d58ab" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">the local government has been given an on-site sewage work declaration for the work under <intref refid="sec.69" target.guid="_3d3525f8-e70f-4f6e-80d1-1b9955cf057a" check="valid">section&#160;69</intref><intref refid="sec.69-ssec.2" target.guid="_ed8d9b1c-b488-466a-8513-cc321d522310" check="valid">(2)</intref>;</txt></block></li><li id="sec.84-ssec.1-para1.b-para2.iv" guid="_418ddddf-34b8-462c-9868-d25b6399ce86" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">the local government has accepted a remote area compliance notice for the work; and</txt></block></li></list></block></li><li id="sec.84-ssec.1-para1.c" guid="_b27a7ba4-c7b4-4a2d-8e00-8ec027850d5b" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the local government is satisfied the plumbing or drainage resulting from, or affected by, the work is operational and fit for use.</txt></block></li></list></block></subclause><subclause id="sec.84-ssec.2" guid="_ee808b12-cc98-46d5-a10b-64027b7b3256" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0"><intref refid="sec.84-ssec.1" target.guid="_6a222a04-8657-41c7-90b6-932698868cd9" check="valid">Subsection&#160;(1)</intref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.84-ssec.2-para1.a" guid="_49f3f236-4771-411c-865f-b3ca12da7506" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">applies subject to <intref refid="sec.85" target.guid="_864476b2-5244-4d68-968d-9970708a9e32" check="valid">section&#160;85</intref>; and</txt></block></li><li id="sec.84-ssec.2-para1.b" guid="_f19e4321-87a6-402d-b0c6-4dbb67fd8f99" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">does not require a local government to give a final inspection certificate for work for which the local government has already given a final inspection certificate.</txt></block></li></list></block></subclause><subclause id="sec.84-ssec.3" guid="_2ee580d7-861b-4a54-9990-91eff4055fa8" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Subject to <intref refid="sec.84-ssec.4" target.guid="_9e490124-7cc9-4f0a-ab3a-4cfbde9cfff9" check="valid">subsection&#160;(4)</intref>, the local government must give the certificate within 2 business days after the following day—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.84-ssec.3-para1.a" guid="_9260997e-c619-4801-9763-87edd806a04e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">if the work has been inspected and <intref refid="sec.84-ssec.1" target.guid="_6a222a04-8657-41c7-90b6-932698868cd9" check="valid">subsection&#160;(1)</intref><intref refid="sec.84-ssec.1-para1.b" target.guid="_33e37ca7-a1d0-4f94-a0a6-1d706f240f5d" check="valid">(b)</intref><intref refid="sec.84-ssec.1-para1.b-para2.i" target.guid="_74f894ee-0d28-4a37-8800-d547a9e98c0f" check="valid">(i)</intref> applies—the day the work was inspected;</txt></block></li><li id="sec.84-ssec.3-para1.b" guid="_66714e45-bdda-454d-ac28-4e8906c4496b" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the local government has been given a covered work declaration for the work—the day the declaration was given; </txt></block></li><li id="sec.84-ssec.3-para1.c" guid="_4cefd44d-438f-48f4-a983-3d78160e1eef" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">if the local government has been given an on-site sewage work declaration for the work—the day the declaration was given; </txt></block></li><li id="sec.84-ssec.3-para1.d" guid="_84de4965-e4f1-4dff-85a1-4540da9516cd" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">if the local government has accepted a remote area compliance notice for the work—the day the notice was accepted.</txt></block></li></list></block></subclause><subclause id="sec.84-ssec.4" guid="_9e490124-7cc9-4f0a-ab3a-4cfbde9cfff9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If 2 or more of <intref refid="sec.84-ssec.3" target.guid="_2ee580d7-861b-4a54-9990-91eff4055fa8" check="valid">subsection&#160;(3)</intref><intref refid="sec.84-ssec.3-para1.a" target.guid="_9260997e-c619-4801-9763-87edd806a04e" check="valid">(a)</intref>, <intref refid="sec.84-ssec.3-para1.b" target.guid="_66714e45-bdda-454d-ac28-4e8906c4496b" check="valid">(b)</intref>, <intref refid="sec.84-ssec.3-para1.c" target.guid="_4cefd44d-438f-48f4-a983-3d78160e1eef" check="valid">(c)</intref> or <intref refid="sec.84-ssec.3-para1.d" target.guid="_84de4965-e4f1-4dff-85a1-4540da9516cd" check="valid">(d)</intref> apply to parts of the work for which a final inspection certificate is to be given, the local government must give the certificate within 2 business days after the latest day as required under <intref refid="sec.84-ssec.3" target.guid="_2ee580d7-861b-4a54-9990-91eff4055fa8" check="valid">subsection&#160;(3)</intref><intref refid="sec.84-ssec.3-para1.a" target.guid="_9260997e-c619-4801-9763-87edd806a04e" check="valid">(a)</intref>, <intref refid="sec.84-ssec.3-para1.b" target.guid="_66714e45-bdda-454d-ac28-4e8906c4496b" check="valid">(b)</intref>, <intref refid="sec.84-ssec.3-para1.c" target.guid="_4cefd44d-438f-48f4-a983-3d78160e1eef" check="valid">(c)</intref> or <intref refid="sec.84-ssec.3-para1.d" target.guid="_84de4965-e4f1-4dff-85a1-4540da9516cd" check="valid">(d)</intref>.</txt></block></subclause></clause><clause id="sec.85" guid="_864476b2-5244-4d68-968d-9970708a9e32" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>85</no><heading id="sec.85-he" guid="_e4ab48bb-afa2-410c-92d9-48d0f84db6b0">When local government is not required to give certificate</heading><subclause id="sec.85-ssec" guid="_37ad7b42-2074-4307-8723-1118ca673a24" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">The local government is not required to give the responsible person for work an inspection certificate or final inspection certificate for the work if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.85-ssec-para1.a" guid="_e0b3ea24-2dd6-449f-a5e8-5f7ec7858ea5" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the local government or an inspector has given the person an action notice relating to the work or part of the work; and</txt></block></li><li id="sec.85-ssec-para1.b" guid="_ae137cb4-33ef-4616-84a5-d2ab15f1b9db" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">any of the following applies—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.85-ssec-para1.b-para2.i" guid="_bc2f2e07-bb6a-43c6-97da-ad2108ef9d81" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the person has not complied with the action notice; </txt></block></li><li id="sec.85-ssec-para1.b-para2.ii" guid="_41f0831a-492a-40aa-b5a6-37321f4b8ba3" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">if the person has appealed against the decision to give the action notice—the appeal has not ended;</txt></block></li><li id="sec.85-ssec-para1.b-para2.iii" guid="_6d1deaac-05fc-4994-ab0d-a1acd81345c6" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">if the action notice requires the person to apply to amend the permit—the local government has not issued an amended permit in response to the application. </txt></block></li></list></block></li></list></block></subclause></clause><clause id="sec.86" guid="_d43b28c0-8110-4336-a32a-2d7b65c143ee" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>86</no><heading id="sec.86-he" guid="_2049b1c7-83fa-45f9-aac5-17e4855662c3">Giving copies of final inspection certificate</heading><subclause id="sec.86-ssec.1" guid="_9e029f30-9a15-4ce2-b955-d9a01a0b6705" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The local government must, within 2 business days after giving a final inspection certificate for work under <intref refid="sec.84" target.guid="_ba2f803c-0b30-469f-9786-f586c6ff1e24" check="valid">section&#160;84</intref>, give a copy of the certificate to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.86-ssec.1-para1.a" guid="_2ff6601c-6e49-41b4-ae68-78504a8b4c0b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the permit holder; and </txt></block></li><li id="sec.86-ssec.1-para1.b" guid="_3d9d1b74-f98a-46e7-b8b4-8ff55a550d68" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the permit holder is not the owner of the premises—the owner of the premises; and </txt></block></li><li id="sec.86-ssec.1-para1.c" guid="_c4e163b0-6145-4569-93b3-a4dff945476d" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">if the work involves installing a water meter and the local government is not the water service provider for the premises—the water service provider. </txt></block></li></list></block></subclause><subclause id="sec.86-ssec.2" guid="_fe31b2d2-0283-49fd-a83e-da7da31435ce" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0"><intref refid="sec.86-ssec.3" target.guid="_cd04096e-8f7f-4165-9107-c767dfee07c1" check="valid">Subsection&#160;(3)</intref> applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.86-ssec.2-para1.a" guid="_b2fd6a46-90c8-472d-a5bf-d36211b7a162" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the local government is a participating local government for a distributor-retailer; and</txt></block></li><li id="sec.86-ssec.2-para1.b" guid="_feddd8b7-c369-44d8-84a3-74de84a6b3f4" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the distributor-retailer, by notice given to the local government, asks the local government to give the distributor-retailer—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.86-ssec.2-para1.b-para2.i" guid="_8a2ec41f-1e7e-49fe-80a4-aa5adc0695e9" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a copy of a stated type of final inspection certificate issued by the local government, including the plans for the work to which the certificate relates; or</txt></block></li><li id="sec.86-ssec.2-para1.b-para2.ii" guid="_6b273632-f42e-4564-9d4e-49bfd1ef7af3" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">stated information about prescribed water meters installed on premises in the local government area.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.86-ssec.3" guid="_cd04096e-8f7f-4165-9107-c767dfee07c1" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government must comply with the notice as soon as practicable.</txt></block></subclause><subclause id="sec.86-ssec.4" guid="_fa277529-769e-4107-8f79-b8661bf8ca8c" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.86-ssec.4-def.prescribedwatermeter_" guid="_47ad4f8c-16c8-475d-a91b-ea8f8af359d4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.86-ssec.4-def.prescribedwatermeter" guid="_75c1f5e2-77dc-42ee-a7c3-c62cec14b6f7" type="definition">prescribed water meter</defterm> see <legref jurisd="QLD" type="act" refid="sec.58" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_e94168af-cf8e-4e6c-9a55-2f62cbb77d46" check="valid">section&#160;58</legref><legref jurisd="QLD" type="act" refid="sec.58-ssec.3" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_277ec3fa-d1bc-4709-8e33-496d1f4c0aa9" check="valid">(3)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, definition <defterm guid="_bdada88e-94e4-4708-860b-4bd5ece9cce2" type="mention">prescribed water meter</defterm>.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;86</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_8d905c79-0f7a-4fd3-8855-ebc0243396b7" valid.date="as.made" check="valid">s&#160;10</legref></txt></historynote></clause><clause id="sec.87" guid="_c0308790-b6d0-49e7-b0fd-24b82e73ca69" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>87</no><heading id="sec.87-he" guid="_2090bb46-cec1-4ecb-9cec-ebb96ecbf7f7">Failure of local government to give certificate</heading><subclause id="sec.87-ssec.1" guid="_ffda5efb-4715-443a-9802-50c75bfd6768" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.87-ssec.1-para1.a" guid="_c2d7c19a-aa33-4cfb-a8e2-277879f9132d" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the responsible person for the work asks the local government to inspect the work under <intref refid="sec.63" target.guid="_3bf1146b-c784-4ee4-bbaf-7eb7a5a1ed56" check="valid">section&#160;63</intref> and an inspector does not inspect the work as required under <intref refid="sec.64" target.guid="_6bdca0e8-8a26-4af0-ae0f-aaf35ee86b05" check="valid">section&#160;64</intref><intref refid="sec.64-ssec.2" target.guid="_e4114dd6-672a-438d-9fa1-757a811ae390" check="valid">(2)</intref>; or</txt></block></li><li id="sec.87-ssec.1-para1.b" guid="_c7e50a08-a46b-4c9d-8c80-9c3fb95e14d6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">there is a dispute between the responsible person and the local government about whether the local government should have given the person an inspection certificate for work under <intref refid="sec.83" target.guid="_0ebb817f-7bb2-40a7-a6d2-5c3b7c18b1b8" check="valid">section&#160;83</intref> or a final inspection certificate for work under <intref refid="sec.84" target.guid="_ba2f803c-0b30-469f-9786-f586c6ff1e24" check="valid">section&#160;84</intref>.</txt></block></li></list></block></subclause><subclause id="sec.87-ssec.2" guid="_cbda1c32-e9d2-4724-80c1-8ccd35969083" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government is taken to have decided to refuse to give the inspection certificate or final inspection for the work to the responsible person.</txt></block></subclause><subclause id="sec.87-ssec.3" guid="_6cbb67d2-954c-4c7e-9ef8-1fa4b7fc0abe" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If, under <intref refid="sec.87-ssec.2" target.guid="_cbda1c32-e9d2-4724-80c1-8ccd35969083" check="valid">subsection&#160;(2)</intref>, the local government is taken to have decided to refuse to give an inspection certificate or final inspection certificate, the responsible person is entitled to be given an information notice about the decision.</txt><note id="sec.87-ssec.3-note" guid="_cb301929-dcfc-40e3-9d5f-249afc7d44ba" type="example"><heading id="sec.87-ssec.3-note-he" guid="_5ddcaadf-66f6-4a7d-99f4-8ddab8818660">Note—</heading><block><txt break.before="1">For an appeal against the decision, see the <legref jurisd="QLD" type="act" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" check="valid"><name emphasis="yes">Planning Act 2016</name></legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_b27e6fb3-817d-489b-ba9f-f87df89be113" check="valid">schedule&#160;1</legref>, <legref jurisd="QLD" type="act" refid="sch.1-sec.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_e79cbd63-ba5c-415b-bc7d-9217dd599138" check="valid">section&#160;1</legref>, table 3, item 5.</txt></block></note></block></subclause></clause></subdivision><subdivision id="pt.6-div.5-sdiv.3" guid="_83903a2b-4d58-48f8-8add-786dac84f6d5" affected.by.uncommenced="0"><no>Subdivision 3</no><heading id="pt.6-div.5-sdiv.3-he" guid="_3f82411e-e414-468b-a081-7f76dad4d2bd">Certificates given by public sector entity</heading><clause id="sec.88" guid="_182cfa9c-635f-4a6c-a2f8-490d56d27e7b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>88</no><heading id="sec.88-he" guid="_7a7d2a53-158c-4f5c-8a24-e13fffd3b68e">Application of subdivision</heading><block><txt break.before="1">This subdivision applies in relation to work carried out under a permit issued by a public sector entity.</txt></block></clause><clause id="sec.89" guid="_f5739b55-bff3-4162-9889-047d1b3315c0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>89</no><heading id="sec.89-he" guid="_c74a6516-a83c-45c1-ba57-4a4e9e1fa423">Public sector entity giving inspection certificate for work</heading><subclause id="sec.89-ssec" guid="_5c28c23b-0d2d-4b92-bc25-cd31299f9447" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">The public sector entity must give an inspection certificate for the work to the responsible person for the work if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.89-ssec-para1.a" guid="_91013716-e5ca-4af8-98b7-ba5403b877e4" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the person makes a written request to the entity for an inspection certificate for the work; and</txt></block></li><li id="sec.89-ssec-para1.b" guid="_e38a2b39-5c63-4395-a0c4-94a7c93d5a1d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the work comprises only part of the work authorised to be carried out under the permit for premises; and</txt></block></li><li id="sec.89-ssec-para1.c" guid="_31c55df7-f131-44f8-bc3a-8149df004068" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the entity or an inspector for the local government has inspected the work; and</txt></block></li><li id="sec.89-ssec-para1.d" guid="_92b492ae-6871-4aa7-89c2-9261ee67adf5" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the entity is satisfied the work is compliant.</txt></block></li></list></block></subclause></clause><clause id="sec.90" guid="_24286415-8220-43ef-ab09-ade60a226a85" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>90</no><heading id="sec.90-he" guid="_ce1e9ae5-e079-4495-b795-af651f4ea1eb">Public sector entity giving final inspection certificate for work</heading><subclause id="sec.90-ssec.1" guid="_2c5cd1d2-8f89-42dc-be41-1c19ec4f8a16" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The public sector entity must give a final inspection certificate for the work to the responsible person for the work if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.90-ssec.1-para1.a" guid="_4aeebc46-1474-49be-8edd-fe113b903cd5" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the work comprises—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.90-ssec.1-para1.a-para2.i" guid="_84b77050-d366-46cf-ab35-4fdc37890491" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">all of the work authorised to be carried out under the permit; or</txt></block></li><li id="sec.90-ssec.1-para1.a-para2.ii" guid="_b2a30161-363a-4521-96d1-88e0497cfe48" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">for a permit authorising work to be carried out for 2 or more premises—all of the work authorised to be carried out under the permit for 1 or more of the premises; and</txt></block></li></list></block></li><li id="sec.90-ssec.1-para1.b" guid="_bc50e031-38b0-47d2-af2b-5f195c61ba9a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the entity or an inspector for the local government has inspected the work; and</txt></block></li><li id="sec.90-ssec.1-para1.c" guid="_0101bae1-b36b-4a7b-8fea-0bcd89c420d7" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the entity is satisfied—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.90-ssec.1-para1.c-para2.i" guid="_54714a21-30c6-4dff-a050-7eb1b8cb4e8e" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the work is compliant; and</txt></block></li><li id="sec.90-ssec.1-para1.c-para2.ii" guid="_0b599bd7-57fb-4950-b5af-90f6815c7606" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the plumbing or drainage resulting from, or affected by, the work is operational and fit for use.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.90-ssec.2" guid="_ab0d96ac-fb59-4dc1-b814-838637d4f317" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0"><intref refid="sec.90-ssec.1" target.guid="_2c5cd1d2-8f89-42dc-be41-1c19ec4f8a16" check="valid">Subsection&#160;(1)</intref> does not require a public sector entity to give a final inspection certificate for work for which the entity has already given a final inspection certificate.</txt></block></subclause></clause><clause id="sec.91" guid="_f6b054c3-b3ee-4b85-91b5-32da6130d976" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>91</no><heading id="sec.91-he" guid="_795378ae-63f2-4a12-bc84-438e5a4aabc5">Giving copies of final inspection certificate</heading><subclause id="sec.91-ssec" guid="_0c51ef80-685d-4185-8432-2e44fbb6ec81" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">If the public sector entity gives a final inspection certificate for work under <intref refid="sec.90" target.guid="_24286415-8220-43ef-ab09-ade60a226a85" check="valid">section&#160;90</intref>, the entity must give a copy of the certificate to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.91-ssec-para1.a" guid="_ad80fa4e-6752-4594-a6f3-cd09530e4f37" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the permit holder; and </txt></block></li><li id="sec.91-ssec-para1.b" guid="_0d3344f9-af3a-4f90-a1f4-ad43eab22e6c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the permit holder is not the owner of the premises—the owner of the premises; and </txt></block></li><li id="sec.91-ssec-para1.c" guid="_6da2f412-2850-4051-b522-9e22c274c92c" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the local government; and</txt></block></li><li id="sec.91-ssec-para1.d" guid="_a7956dcf-9a13-4772-b077-1af01c5801f4" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">if a distributor-retailer supplies a water service or sewerage service for the premises—the distributor-retailer; and</txt></block></li><li id="sec.91-ssec-para1.e" guid="_d0db30fa-e63e-4afa-9c2d-60e48be604d4" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">if the work involves installing a water meter and the local government is not the water service provider for the premises—the water service provider. </txt></block></li></list></block></subclause></clause></subdivision></division><division id="pt.6-div.6" guid="_a03d03e9-dbff-4618-9624-9e8add9cba0e" affected.by.uncommenced="0"><no>Division 6</no><heading id="pt.6-div.6-he" guid="_15a9e8eb-2794-4898-aba6-a94b4f5dfcd6">Inspecting notifiable work not under permit</heading><clause id="sec.92" guid="_7117c037-3537-427a-991d-a38561cbaa59" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>92</no><heading id="sec.92-he" guid="_7bbfb992-88dc-44a8-92f4-170c3be7d267">Application of division</heading><block><txt break.before="1">This division applies in relation to notifiable work carried out for premises that is not the subject of a permit.</txt></block></clause><clause id="sec.93" guid="_db8b6597-290e-4ccb-b10b-fd93b9f9c1c0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>93</no><heading id="sec.93-he" guid="_84e60c17-e29b-4a27-b434-d6e2b3a3dfc9">References to occupier of premises</heading><subclause id="sec.93-ssec" guid="_3e8d5c2c-8bbd-4e62-b211-a9502d7b9695" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">In this division, a reference to the occupier of premises includes, if the occupier is not the owner of the premises, a reference to the owner. </txt></block></subclause></clause><clause id="sec.94" guid="_f34ac93f-1c37-46f1-a807-cdde862b02fb" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>94</no><heading id="sec.94-he" guid="_ac2b3ce4-5079-4edd-9a00-467ad3de0e78">Inspection of notifiable work on request of responsible person</heading><subclause id="sec.94-ssec.1" guid="_bb3fb322-befb-423c-b053-1431ceaabe7d" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the responsible person for the notifiable work asks the local government to inspect the work. </txt></block></subclause><subclause id="sec.94-ssec.2" guid="_f700be64-1376-451c-bc5b-b5cd057c3aee" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An inspector must start inspecting the work within— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.94-ssec.2-para1.a" guid="_29613f0a-7d31-4681-8d03-1e85debe7668" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">1 hour after the time agreed between the local government and the responsible person; or </txt></block></li><li id="sec.94-ssec.2-para1.b" guid="_6fda86c8-c707-461f-a724-117e52da0b2a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if a time is not agreed—48 hours after the responsible person asks the local government to inspect the work. </txt></block></li></list></block></subclause><subclause id="sec.94-ssec.3" guid="_4917a1b0-2c4d-4fcd-ba89-d7a7c72f33da" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An inspector does not fail to comply with <intref refid="sec.94-ssec.2" target.guid="_f700be64-1376-451c-bc5b-b5cd057c3aee" check="valid">subsection&#160;(2)</intref> only because the inspector can not enter the premises.</txt></block></subclause></clause><clause id="sec.95" guid="_5b9c2ec4-31de-4c11-9cab-19d60dd0ad5d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>95</no><heading id="sec.95-he" guid="_c8a3008f-60e3-4dc6-b29c-9d97d5bc9273">Inspection of notifiable work on request of local government</heading><subclause id="sec.95-ssec.1" guid="_f6e76b6e-7207-4bb7-9d5c-9f162eea9182" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.95-ssec.1-para1.a" guid="_90cf43d0-976c-430e-bcf7-d138641b2cbf" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the relevant person for the notifiable work has given the commissioner a notice about the work under <legref jurisd="QLD" type="act" refid="sec.83" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_04f65a58-00b2-4e56-81c7-c0eca16f3495" check="valid">section&#160;83</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref> (a <defterm id="sec.95-ssec.1-def.completionnotice" guid="_88acd87c-a0ca-4238-aeb3-94fb1a2a1eba" type="definition">completion notice</defterm>); and</txt></block></li><li id="sec.95-ssec.1-para1.b" guid="_650c51d6-512c-4172-b647-6ba098d55a5e" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">within 1 year after the completion notice is given, the local government contacts the occupier of the premises to arrange to inspect the work.</txt></block></li></list></block></subclause><subclause id="sec.95-ssec.2" guid="_8e45c702-6b62-40b3-9d9c-2435b046a9ec" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An inspector may, with the consent of the occupier, inspect the notifiable work to check it complies with the code requirements for the work. </txt></block></subclause></clause><clause id="sec.96" guid="_9cd980f7-36e2-4dd9-bee2-fa8099a7d7bb" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>96</no><heading id="sec.96-he" guid="_5f7e302e-536a-4bac-ab93-8b3e0b57b8f9">Action notice for non-compliant notifiable work</heading><subclause id="sec.96-ssec.1" guid="_da92b333-1a54-40b4-8042-bcb9d42fcbaf" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if an inspector inspects the notifiable work under <intref refid="sec.94" target.guid="_f34ac93f-1c37-46f1-a807-cdde862b02fb" check="valid">section&#160;94</intref> or <intref refid="sec.95" target.guid="_5b9c2ec4-31de-4c11-9cab-19d60dd0ad5d" check="valid">95</intref> and is not satisfied the notifiable work or a part of the work is compliant.</txt></block></subclause><subclause id="sec.96-ssec.2" guid="_07525cf3-2a1d-432c-bc04-d7225653dec5" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The inspector may, within 2 business days after finishing the inspection, give the responsible person for the notifiable work an action notice stating the actions the person must take to remedy the matter mentioned in <intref refid="sec.96-ssec.1" target.guid="_da92b333-1a54-40b4-8042-bcb9d42fcbaf" check="valid">subsection&#160;(1)</intref> (the <defterm id="sec.96-def.statedactions" guid="_778bf59f-9761-4333-a697-458cfbd3318e" type="definition">stated actions</defterm>), including, for example—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.96-ssec.2-para1.a" guid="_b273d85d-e82f-46be-8c69-4c5056eb4d5a" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">carrying out particular work; and</txt></block></li><li id="sec.96-ssec.2-para1.b" guid="_9dcf6906-ac06-4345-99aa-9b2638f62ba7" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if work is required to be carried out—requesting a further inspection of the work within a stated period; and</txt></block></li><li id="sec.96-ssec.2-para1.c" guid="_a7fdfae4-4915-44c3-ad51-aa820506f8ad" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">giving the inspector particular information about the work, including, for example, information about any materials used for the work; and</txt></block></li><li id="sec.96-ssec.2-para1.d" guid="_19cfc59f-7d9c-43dc-87e2-b5c0a0564679" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">uncovering plumbing or drainage resulting from, or affected by, the work to the extent necessary to enable the inspector to assess whether the work is compliant.</txt></block></li></list></block></subclause><subclause id="sec.96-ssec.3" guid="_eab32c78-4552-4a7d-9f4e-9701ca1e643c" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, the stated actions may include uncovering plumbing or drainage as mentioned in <intref refid="sec.96-ssec.2" target.guid="_07525cf3-2a1d-432c-bc04-d7225653dec5" check="valid">subsection&#160;(2)</intref><intref refid="sec.96-ssec.2-para1.d" target.guid="_19cfc59f-7d9c-43dc-87e2-b5c0a0564679" check="valid">(d)</intref> only if the inspector reasonably suspects the work is not compliant.</txt></block></subclause></clause></division><division id="pt.6-div.7" guid="_57bd50c9-0316-4f71-8c13-317205bd31b4" affected.by.uncommenced="0"><no>Division 7</no><heading id="pt.6-div.7-he" guid="_5b52489c-e877-4f1a-9a3e-0b23bbd5d5b8">Requirements for action notices</heading><clause id="sec.97" guid="_ada6503c-3747-4625-bb26-7ea7999be21a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>97</no><heading id="sec.97-he" guid="_04040d84-6e52-471c-a255-e13840e411ac">Form and content of action notice</heading><subclause id="sec.97-ssec.1" guid="_189e842c-9b91-46a5-9312-dd6ccaccdd24" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if, under a provision of this regulation (the <defterm id="sec.97-def.enablingprovision" guid="_ac3800ef-349b-49ad-b992-f79e32649ec8" type="definition">enabling provision</defterm>), a local government or an inspector decides to give an action notice to the responsible person for plumbing or drainage work to take action in relation to the work.</txt></block></subclause><subclause id="sec.97-ssec.2" guid="_5440ce83-4a15-4788-b379-11ea7f76d28d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The action notice must state—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.97-ssec.2-para1.a" guid="_6ba2ab70-322a-4f14-9205-b2c8db905c2c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the reason for the decision; and</txt><note id="sec.97-ssec.2-para1.a-note" guid="_dcf6f088-4fd6-4db5-b6e8-2723d4a902a4" type="example"><heading id="sec.97-ssec.2-para1.a-note-he" guid="_c839fbe3-7a21-400b-adef-552add6ba1e4">Example of a reason—</heading><block><txt break.before="1">the local government or inspector is not satisfied a stated part of the work is compliant</txt></block></note></block></li><li id="sec.97-ssec.2-para1.b" guid="_f5ac3478-007a-4458-b3c7-02c9cb4492a6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the facts and circumstances that form the basis for the reason; and</txt></block></li><li id="sec.97-ssec.2-para1.c" guid="_2f88501c-4879-44d9-8482-3241aa6b87cb" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the particular action the person must take in relation to the work to remedy the matters stated in the notice under <intref refid="sec.97-ssec.2-para1.a" target.guid="_6ba2ab70-322a-4f14-9205-b2c8db905c2c" check="valid">paragraphs&#160;(a)</intref> and <intref refid="sec.97-ssec.2-para1.b" target.guid="_f5ac3478-007a-4458-b3c7-02c9cb4492a6" check="valid">(b)</intref>; and</txt></block></li><li id="sec.97-ssec.2-para1.d" guid="_c212c8ff-6642-4454-aceb-f6a7b0be6fef" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the period, that is at least 2 business days after the notice is given, in which the action must be taken; and</txt></block></li><li id="sec.97-ssec.2-para1.e" guid="_394acf08-bdeb-4381-89e7-15a5c5066c73" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">that it is an offence for the responsible person to fail to comply with the notice, unless the person has a reasonable excuse; and</txt></block></li><li id="sec.97-ssec.2-para1.f" guid="_3672d03c-5ae2-4bb0-b218-b20fb77a6c9e" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">any other information as required under the enabling provision.</txt></block></li></list></block></subclause><subclause id="sec.97-ssec.3" guid="_9d99247c-44fc-48c6-9244-978df4bda19c" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The action notice must also be accompanied by, or include, an information notice about the decision to give the notice.</txt><note id="sec.97-ssec.3-note" guid="_2538015d-3be1-4cd0-83d4-835d0aa3b329" type="example"><heading id="sec.97-ssec.3-note-he" guid="_fb9093a6-6898-4bd5-8aa6-e8569f126c40">Note—</heading><block><txt break.before="1">For an appeal against the decision, see the <legref jurisd="QLD" type="act" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" check="valid"><name emphasis="yes">Planning Act 2016</name></legref>, <legref jurisd="QLD" type="act" refid="sch.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_b27e6fb3-817d-489b-ba9f-f87df89be113" check="valid">schedule&#160;1</legref>, <legref jurisd="QLD" type="act" refid="sch.1-sec.1" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_e79cbd63-ba5c-415b-bc7d-9217dd599138" check="valid">section&#160;1</legref>, table 3, item 3.</txt></block></note></block></subclause></clause><clause id="sec.98" guid="_7b34caf0-08a2-4dc0-9b12-fcfaee89b6f3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>98</no><heading id="sec.98-he" guid="_53e47548-bd0a-4308-beb1-ebbf657e508d">Requirement to comply with action notice</heading><subclause id="sec.98-ssec.1" guid="_a3faa114-8c6a-442f-a80a-6b86798e1fa8" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a local government or an inspector gives the responsible person for work an action notice.</txt></block></subclause><subclause id="sec.98-ssec.2" guid="_b0ebb452-f387-4f01-ae51-74a409d9a1d5" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The responsible person must, unless the person has a reasonable excuse, comply with the notice within—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.98-ssec.2-para1.a" guid="_20a8d743-98e1-4e37-a2c6-853615513014" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the period for taking action stated in the notice (the <defterm id="sec.98-ssec.2-def.statedperiod" guid="_ab92207b-de5a-4263-a3ef-33c48f616eb4" type="definition">stated period</defterm>); or </txt></block></li><li id="sec.98-ssec.2-para1.b" guid="_5df95a08-8ebb-4a55-a677-11f7bd74f4b2" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if, before the end of the stated period, a longer period is decided by the local government or inspector—the longer period. </txt></block></li></list><penalty id="sec.98-ssec.2-pen" guid="_2f46c9b9-03a2-4d48-9d88-00708757b25d"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause><subclause id="sec.98-ssec.3" guid="_9b3dc47a-5642-4071-9bcf-075af77291ee" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Also, if the local government or inspector considers the person has not complied with the action notice, the local government must give a copy of the notice to the owner of the premises within 5 business days after the end of the required period for compliance under <intref refid="sec.98-ssec.2" target.guid="_b0ebb452-f387-4f01-ae51-74a409d9a1d5" check="valid">subsection&#160;(2)</intref>.</txt></block></subclause><note id="sec.98-note" guid="_95ae3d28-4075-4b0a-bf8d-3d934e9013b2" type="example"><heading id="sec.98-note-he" guid="_fff34b01-29cf-4f04-b87e-5f53a5bd811c">Note—</heading><block><txt break.before="1">For complying with a requirement in an action notice to apply under <intref refid="pt.5" target.guid="_357246d4-1e65-48ec-b9a7-5400c77d68d5" check="valid">part&#160;5</intref>, <intref refid="pt.5-div.2" target.guid="_739f64a2-5458-4cb7-aab6-900e306592c7" check="valid">division&#160;2</intref>, to amend a permit, see <intref refid="sec.43" target.guid="_5950f1e5-d2ea-463b-ba8a-32bb57537bd5" check="valid">section&#160;43</intref><intref refid="sec.43-ssec.3" target.guid="_ae61810c-393f-4e26-bab3-e376dd584d27" check="valid">(3)</intref>.</txt></block></note></clause></division></part><part id="pt.7" guid="_63fe845c-1661-43c6-8036-d6018b597c42" affected.by.uncommenced="0"><no>Part 7</no><heading id="pt.7-he" guid="_9b6f4a74-597f-4766-9fa9-9b16e6551909">Installation, maintenance and related matters</heading><clause id="sec.99" guid="_ed40e207-abea-4d77-a479-485c7973cfc0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>99</no><heading id="sec.99-he" guid="_14ee2981-b887-45f7-bcb6-d230da00b51b">Things approved for installation as plumbing or drainage—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.65" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b4d29d10-8405-451e-a13b-3b5ec933e3b5" check="valid">s&#160;65</legref></heading><subclause id="sec.99-ssec.1" guid="_1927492c-746a-4ae8-b32f-d7b85e104b52" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section prescribes, for <legref jurisd="QLD" type="act" refid="sec.65" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b4d29d10-8405-451e-a13b-3b5ec933e3b5" check="valid">section&#160;65</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref><legref jurisd="QLD" type="act" check="invalid">(f)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, a thing that is approved for installation as plumbing or drainage.</txt></block></subclause><subclause id="sec.99-ssec.2" guid="_4977837a-f380-498c-a57f-8a073461d8dd" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A fire service product for a fire service is approved for installation as plumbing or drainage if the fire service product—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.2-para1.a" guid="_1fe8b4f9-e920-4fbd-8234-bfa14934b53e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">is recommended for installation in the fire service by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.2-para1.a-para2.i" guid="_e1a5b73b-0553-45c4-908c-2ab113d61138" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a certification body; or</txt></block></li><li id="sec.99-ssec.2-para1.a-para2.ii" guid="_e311e394-1889-47e2-b3ac-da31ac561d92" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">a testing or approval body; and</txt></block></li></list></block></li><li id="sec.99-ssec.2-para1.b" guid="_7754ae0e-bfac-4539-812f-76c81765956f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">is marked as required—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.2-para1.b-para2.i" guid="_6b3d68cd-8740-4423-9717-384b92a077ae" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">under a scheme endorsed by a certification body; or</txt></block></li><li id="sec.99-ssec.2-para1.b-para2.ii" guid="_de79eb13-2abd-42b6-954f-89fa2762796e" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">by a testing or approval body; and</txt></block></li></list></block></li><li id="sec.99-ssec.2-para1.c" guid="_c4c7b682-dbfc-40f7-99ad-76738bb0c765" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">has been tested as required—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.2-para1.c-para2.i" guid="_f41e2279-42bb-4653-8cc2-ff5016e94bb3" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">under a method endorsed by a certification body; or</txt></block></li><li id="sec.99-ssec.2-para1.c-para2.ii" guid="_4d2548bb-5d1a-459a-9e41-0b215f60d17e" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">by a testing or approval body; and</txt></block></li></list></block></li><li id="sec.99-ssec.2-para1.d" guid="_a5912251-2810-4ec4-8af7-9e8bc8c67fb6" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">complies with <intref refid="sec.99-ssec.4" target.guid="_93b7c100-ef7e-446d-9f57-4f459d9b2462" check="valid">subsection&#160;(4)</intref>, if relevant.</txt></block></li></list></block></subclause><subclause id="sec.99-ssec.3" guid="_466165da-f5e7-4a57-ac87-3f220787f25e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Despite <intref refid="sec.99-ssec.2" target.guid="_4977837a-f380-498c-a57f-8a073461d8dd" check="valid">subsection&#160;(2)</intref>, a fire service product for a fire service that is a fitting, pipe, pump or valve is also approved for installation as plumbing or drainage if the fire service product complies with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.3-para1.a" guid="_5a10607c-582e-419b-85ce-55ae17a5d16b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">either—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.3-para1.a-para2.i" guid="_5d4662fc-967e-4426-b47f-d411630ee3e8" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a relevant automatic fire sprinkler systems standard; or</txt></block></li><li id="sec.99-ssec.3-para1.a-para2.ii" guid="_9ab5aceb-55bc-476e-97f7-91cc23e210cb" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">a relevant fire hydrant installations standard; and</txt></block></li></list></block></li><li id="sec.99-ssec.3-para1.b" guid="_1ee3ccd9-b345-4a9e-b38d-2fd98446e787" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0"><intref refid="sec.99-ssec.4" target.guid="_93b7c100-ef7e-446d-9f57-4f459d9b2462" check="valid">subsection&#160;(4)</intref>, if relevant.</txt></block></li></list></block></subclause><subclause id="sec.99-ssec.4" guid="_93b7c100-ef7e-446d-9f57-4f459d9b2462" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the fire service product is connected to a water service provider’s infrastructure, the fire service product must be installed downstream of an acceptable backflow prevention device.</txt></block></subclause><subclause id="sec.99-ssec.5" guid="_22a84baa-94b5-4c9c-8583-b82c512d6856" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.99-ssec.5-def.acceptablebackflowpreventiondevice_" guid="_6d129a55-02cf-42b7-a6f9-eba9efdca057" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.99-ssec.5-def.acceptablebackflowpreventiondevice" guid="_d743eb7a-f886-467a-b3f3-bcf5e859ac10" type="definition">acceptable backflow prevention device</defterm> means a testable backflow prevention device that is a WaterMark product complying with the code requirements for plumbing or drainage work.</txt></definition><definition id="sec.99-ssec.5-def.certificationbody_" guid="_06519c66-229b-4a5b-bb22-61d96b76c088" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.99-ssec.5-def.certificationbody" guid="_7bfb9871-6a97-4981-8dab-89874b7c723c" type="definition">certification body</defterm> means a body accredited as a certification body by the Joint Accreditation System of Australia and New Zealand.</txt></definition><definition id="sec.99-ssec.5-def.fireserviceproduct_" guid="_eda8072c-f69b-4ce6-926b-7ca495246386" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.99-ssec.5-def.fireserviceproduct" guid="_bffbda8a-5bf3-4da0-8c39-5cebedb56700" type="definition">fire service product</defterm>, for a fire service, means a thing that is part of the fire service.</txt></definition><definition id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard_" guid="_d94031df-2ffd-4a0b-8b58-8ad05cdf9928" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard" guid="_31d87144-e3a9-47fc-a033-cd9556e569af" type="definition">relevant automatic fire sprinkler systems standard</defterm> means a standard under any of the following designations as in force on the commencement—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard-para1" guid="_ab02c299-4a71-436d-a7d5-7fe747c1ed70" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2118.1:2017</txt></block></li><li id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard-para1-oc.2" guid="_499eb8c0-e5ab-4be4-8973-56138e3791dc" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2118.2—2010</txt></block></li><li id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard-para1-oc.3" guid="_b580e469-71fa-40be-9f1d-57aa3aaca128" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2118.3—2010</txt></block></li><li id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard-para1-oc.4" guid="_1c4fb82e-c917-4c7b-a721-f9b4e24dbb24" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2118.4—2012</txt></block></li><li id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard-para1-oc.5" guid="_1ce81982-a5c4-41ef-9166-80f2a17bf00d" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2118.5—2008</txt></block></li><li id="sec.99-ssec.5-def.relevantautomaticfiresprinklersystemsstandard-para1-oc.6" guid="_de3b2229-7b96-4600-bedb-1f5b9b7274f3" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2118.6—2012.</txt></block></li></list></definition><definition id="sec.99-ssec.5-def.relevantfirehydrantinstallationsstandard_" guid="_710947c4-0f3c-46b4-a0d2-856cbccd7d8e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.99-ssec.5-def.relevantfirehydrantinstallationsstandard" guid="_a8d202bd-3934-42f8-8e1f-e31c4c0b6970" type="definition">relevant fire hydrant installations standard</defterm> means a standard under any of the following designations as in force on the commencement—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.99-ssec.5-def.relevantfirehydrantinstallationsstandard-para1" guid="_426f8a80-e723-4f7d-945a-59245eb40d4a" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2419.1:2017</txt></block></li><li id="sec.99-ssec.5-def.relevantfirehydrantinstallationsstandard-para1-oc.2" guid="_39f05174-04b3-4e0c-b978-8817aa862fdf" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2419.2—2009</txt></block></li><li id="sec.99-ssec.5-def.relevantfirehydrantinstallationsstandard-para1-oc.3" guid="_1fcebf28-2532-4ff9-822d-c26e7a1a1807" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">AS 2419.3—2012.</txt></block></li></list></definition><definition id="sec.99-ssec.5-def.testingorapprovalbody_" guid="_8e87a638-5159-4e40-8631-0dab6f3be9ae" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.99-ssec.5-def.testingorapprovalbody" guid="_0fd86b64-58d7-401f-811f-8d084ed7f66c" type="definition">testing or approval body</defterm> means a body that is recognised nationally or internationally for testing or approving fire services.</txt></definition></deflist></block></subclause></clause><clause id="sec.100" guid="_06a28c5d-6832-4a0a-aa39-fe8d8af26a4a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>100</no><heading id="sec.100-he" guid="_7d287cc6-7789-4f87-9aea-e4b76711645e">Installing water meters</heading><subclause id="sec.100-ssec.1" guid="_84546712-b005-4bdb-8878-efdba084cfce" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if plumbing work involves installing a water meter for— </txt><list number.type="manual" unnumbered.indent="0"><li id="sec.100-ssec.1-para1.a" guid="_399a626e-d6c7-4503-8c85-c08086e1a8f7" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a class 1 building on a lot that is part of a community titles scheme; or</txt></block></li><li id="sec.100-ssec.1-para1.b" guid="_5edcdc0f-181e-4800-8f27-54028484d7a6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a class 2 to 9 building.</txt></block></li></list></block></subclause><subclause id="sec.100-ssec.2" guid="_83021dbf-3d68-4849-9ab7-b79a4343bae4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The responsible person for the work must, at least 2 business days before the plumbing work is covered, give notice that the water meter has been installed to the water service provider for the building. </txt></block><penalty id="sec.100-ssec.2-pen" guid="_c9689a63-00f9-4cba-a753-421cfbd25185"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><historynote><txt break.before="1"><b>s&#160;100</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_ccc0e4cb-6296-4166-850a-e79788e5f3db" valid.date="as.made" check="valid">s&#160;11</legref></txt></historynote></clause><clause id="sec.101" guid="_d18b8b49-f4d2-47e2-b45a-d22ed9dc958b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>101</no><heading id="sec.101-he" guid="_e95fd54a-92c7-4375-9ec2-0c493ebe84ba">Testable backflow prevention device—obligation of local government</heading><subclause id="sec.101-ssec" guid="_d9fed043-3794-48d4-9258-1eba55f7b2ce" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">A local government must establish a program for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.101-ssec-para1.a" guid="_e6a1ba65-1d4d-4bbf-a7c6-24ffcfb557ce" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">registering each testable backflow prevention device installed at premises in its local government area; and</txt></block></li><li id="sec.101-ssec-para1.b" guid="_a8b78420-cfa4-4aba-af9c-4712b9b211c5" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">monitoring the maintenance and testing of each device.</txt></block></li></list></block></subclause></clause><clause id="sec.102" guid="_7aaa282e-51e1-4b3a-b693-7ba1df4b3c90" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>102</no><heading id="sec.102-he" guid="_f24ef8e0-4f6b-4c2a-9173-4c37175fca45">Testable backflow prevention device—obligations of owner of premises</heading><subclause id="sec.102-ssec.1" guid="_98dbb598-2add-4c36-9b25-f5466ce0e3bb" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a testable backflow prevention device is installed at premises in a local government area, whether the device is installed for the first time or to replace a device already at the premises.</txt></block></subclause><subclause id="sec.102-ssec.2" guid="_39b3097c-313d-463e-9411-7feac7e14cf9" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The owner of the premises must register the testable backflow prevention device, by giving notice, in the approved form, to the local government.</txt><penalty id="sec.102-ssec.2-pen" guid="_448bf69d-41dc-4f8d-8284-566e0c8090cf"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause><subclause id="sec.102-ssec.3" guid="_cbce289b-fd9b-4657-aa86-b19d1b5064ba" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, the owner of the premises need not comply with <intref refid="sec.102-ssec.2" target.guid="_39b3097c-313d-463e-9411-7feac7e14cf9" check="valid">subsection&#160;(2)</intref> if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.102-ssec.3-para1.a" guid="_049ef650-367c-4fd1-8c0c-86e952c580bc" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the device has already been registered under <intref refid="sec.102-ssec.2" target.guid="_39b3097c-313d-463e-9411-7feac7e14cf9" check="valid">subsection&#160;(2)</intref> after being installed under <intref refid="sec.102-ssec.1" target.guid="_98dbb598-2add-4c36-9b25-f5466ce0e3bb" check="valid">subsection&#160;(1)</intref>; or</txt></block></li><li id="sec.102-ssec.3-para1.b" guid="_81b5f752-37f7-4848-869a-8140f214eade" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a licensee has installed the device under <intref refid="sec.103" target.guid="_505db557-644f-40d3-8746-cc615c2695d0" check="valid">section&#160;103</intref><intref refid="sec.103-ssec.1" target.guid="_a6aabffe-807b-4317-90ea-9894325b49fc" check="valid">(1)</intref><intref refid="sec.103-ssec.1-para1.a" target.guid="_848249ac-c459-45c3-9bdd-22da6f378a9a" check="valid">(a)</intref> and given the local government notice of the installation as mentioned in <intref refid="sec.103" target.guid="_505db557-644f-40d3-8746-cc615c2695d0" check="valid">section&#160;103</intref><intref refid="sec.103-ssec.3" target.guid="_03eee920-18ac-4c88-b882-bef7521ad672" check="valid">(3)</intref>; or</txt></block></li><li id="sec.102-ssec.3-para1.c" guid="_286f7dac-fa97-4521-9cd5-bcfa110a1d52" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a backflow prevention licensee has maintained and tested the device and given the local government notice of the maintenance and testing as mentioned in <intref refid="sec.103" target.guid="_505db557-644f-40d3-8746-cc615c2695d0" check="valid">section&#160;103</intref><intref refid="sec.103-ssec.3" target.guid="_03eee920-18ac-4c88-b882-bef7521ad672" check="valid">(3)</intref>.</txt></block></li></list></block></subclause><subclause id="sec.102-ssec.4" guid="_10510ebc-afbd-4a66-a939-b57484781ee9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The owner of the premises must also arrange for a backflow prevention licensee to maintain and test the device at least once each year after the device is registered.</txt><penalty id="sec.102-ssec.4-pen" guid="_462ac508-b7ac-4817-b4d4-24065f069560"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause></clause><clause id="sec.103" guid="_505db557-644f-40d3-8746-cc615c2695d0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>103</no><heading id="sec.103-he" guid="_91d66b00-1222-48aa-b19e-3dbbb803b99c">Testable backflow prevention device—obligation of licensee</heading><subclause id="sec.103-ssec.1" guid="_a6aabffe-807b-4317-90ea-9894325b49fc" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a licensee carries out the following work (the <defterm id="sec.103-def.relevantwork" guid="_9a47177f-d29a-4766-be45-3598226791ce" type="definition">relevant work</defterm>)—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.103-ssec.1-para1.a" guid="_848249ac-c459-45c3-9bdd-22da6f378a9a" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">installing a testable backflow prevention device at premises, whether for the first time or to replace a device previously installed; </txt></block></li><li id="sec.103-ssec.1-para1.b" guid="_9bec45c8-dba6-4c86-8e87-bc32d1c58eb4" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">removing a testable backflow prevention device from premises.</txt></block></li></list></block></subclause><subclause id="sec.103-ssec.2" guid="_19b249c7-76bb-4e11-9454-770dbfffc88b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">This section also applies if the owner of premises where a testable backflow prevention device is installed arranges for a backflow prevention licensee to maintain and test the device (also the <defterm id="sec.103-def.relevantwork-oc.2" guid="_4536eade-505b-456d-9539-bdc5e26fa93b" type="definition">relevant work</defterm>), whether to comply with <intref refid="sec.102" target.guid="_7aaa282e-51e1-4b3a-b693-7ba1df4b3c90" check="valid">section&#160;102</intref><intref refid="sec.102-ssec.4" target.guid="_10510ebc-afbd-4a66-a939-b57484781ee9" check="valid">(4)</intref> or an enforcement notice.</txt></block></subclause><subclause id="sec.103-ssec.3" guid="_03eee920-18ac-4c88-b882-bef7521ad672" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The licensee must, within 10 business days after carrying out the relevant work, give notice of the relevant work in the approved form to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.103-ssec.3-para1.a" guid="_f93e6974-a905-427b-a7cb-cd88b0751664" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the local government; and</txt></block></li><li id="sec.103-ssec.3-para1.b" guid="_2a4792ac-d7cf-4c9b-a5fd-c7f17a528b1d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the owner of the premises.</txt></block></li></list><penalty id="sec.103-ssec.3-pen" guid="_21c60dc0-3ef1-4a67-ad4f-08873f63e294"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause></clause><clause id="sec.103A" guid="_aafac763-831b-41ac-a728-cfd106e50ea9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>103A </no><heading id="sec.103A-he" guid="_5892c85f-b170-49dd-9df6-1e7d3ec07fcf">Prescribed use of greywater—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.79" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a8ef555a-9de4-4cb6-a8dd-a99302884d70" check="valid">s&#160;79</legref></heading><subclause id="sec.103A-ssec.1" guid="_22594ee4-82bb-48d5-9c98-b825b1dd55f1" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to greywater, other than kitchen greywater, from plumbing and drainage on premises in a sewered area.</txt></block></subclause><subclause id="sec.103A-ssec.2" guid="_e72e93f1-568e-46b4-ad4d-f4d6471ece84" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.79" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a8ef555a-9de4-4cb6-a8dd-a99302884d70" check="valid">section&#160;79</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_61830ecc-528b-41d8-bbe4-685da0e625fb" check="valid">(5)</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5-para1.b" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_9b8bff66-83d8-4544-a5f6-9294154aed34" check="valid">(b)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, supplying the greywater to a cooling tower that is a part of an air-conditioning unit installed on the premises is prescribed as a use of the greywater.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;103A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_7ce03a8f-c1df-42ad-b999-1130563f60a5" valid.date="as.made" check="valid">s&#160;12</legref></txt></historynote></clause><clause id="sec.103B" guid="_667ec218-2b48-41a3-b165-575acf08e3b9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>103B </no><heading id="sec.103B-he" guid="_f1978e7a-8686-4c2c-9ecf-98b2d4ac319d">Capacity for greywater (cooling tower) treatment plant and required standard for greywater—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.79" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a8ef555a-9de4-4cb6-a8dd-a99302884d70" check="valid">s&#160;79</legref></heading><subclause id="sec.103B-ssec.1" guid="_b82fb2e4-1091-43ab-a83b-9fd4351bdfb3" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.103B-ssec.1-para1.a" guid="_3224f3b2-33c0-4716-8dbf-10ea44a55867" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">greywater, other than kitchen greywater, is discharged into a greywater use facility on premises in a sewered area; and</txt></block></li><li id="sec.103B-ssec.1-para1.b" guid="_45b9a903-8552-42db-80a5-967c91977644" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the greywater use facility includes a greywater treatment plant (the <defterm id="sec.103B-ssec.1-def.greywatercoolingtowertreatmentplant" guid="_69ff03c9-b818-4455-8ba0-fe00ee5d9bed" type="definition">greywater (cooling tower) treatment plant</defterm>)—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.103B-ssec.1-para1.b-para2.i" guid="_14b80960-2168-4130-9509-b646432a719a" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">in which the greywater is treated; and </txt></block></li><li id="sec.103B-ssec.1-para1.b-para2.ii" guid="_49a8ecc5-b602-4b93-a9bb-e01c1b82c599" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">from which the greywater is supplied to a cooling tower that is a part of an air-conditioning unit installed on the premises.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.103B-ssec.2" guid="_238777fe-a0a8-48f3-b5d8-bc30459486aa" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.79" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a8ef555a-9de4-4cb6-a8dd-a99302884d70" check="valid">section&#160;79</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_61830ecc-528b-41d8-bbe4-685da0e625fb" check="valid">(5)</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5-para1.b" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_9b8bff66-83d8-4544-a5f6-9294154aed34" check="valid">(b)</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5-para1.b-para2.ii" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_e8d2f638-e38e-4a1b-b540-131197a871f5" check="valid">(ii)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the capacity for the greywater (cooling tower) treatment plant is 20kL or more of treated greywater in a day.</txt></block></subclause><subclause id="sec.103B-ssec.3" guid="_9ad0e35d-b802-4a62-aba3-db3eb167b14d" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.79" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a8ef555a-9de4-4cb6-a8dd-a99302884d70" check="valid">section&#160;79</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_61830ecc-528b-41d8-bbe4-685da0e625fb" check="valid">(5)</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5-para1.b" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_9b8bff66-83d8-4544-a5f6-9294154aed34" check="valid">(b)</legref><legref jurisd="QLD" type="act" refid="sec.79-ssec.5-para1.b-para2.iii" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_bd38d6dd-1021-483f-a125-184b4bf7afb6" check="valid">(iii)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the prescribed standard to which the greywater is to be treated is the required standard.</txt></block></subclause><subclause id="sec.103B-ssec.4" guid="_e2352701-4255-41bc-a789-48b9c0d4f966" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">For <intref refid="sec.103B-ssec.3" target.guid="_9ad0e35d-b802-4a62-aba3-db3eb167b14d" check="valid">subsection&#160;(3)</intref>, the greywater is treated to the required standard if each parameter for the treated greywater stated in <intref refid="sch.7A" target.guid="_1d7cb81d-26e8-4473-9fb4-cc45a7bbb52b" check="valid">schedule&#160;7A</intref>, column 1 is at the concentration or value, or within the range of concentrations or values, stated opposite the parameter in column 2 of the schedule.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;103B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_7ce03a8f-c1df-42ad-b999-1130563f60a5" valid.date="as.made" check="valid">s&#160;12</legref></txt></historynote></clause><clause id="sec.104" guid="_9d6fe7c8-bfd8-471c-9582-5108a9ec886b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>104</no><heading id="sec.104-he" guid="_2eea25a2-3059-48ce-84e7-102385039c58">Monitoring particular types of greywater use facility—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.136" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8f3c1e6f-df4f-476e-806f-336b663c8fde" check="valid">s&#160;136</legref></heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.136" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8f3c1e6f-df4f-476e-806f-336b663c8fde" check="valid">section&#160;136</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the types of greywater use facilities are each greywater use facility, consisting of a greywater treatment plant, with or without a land application area, installed in a sewered area.</txt></block><historynote><txt break.before="1"><b>s&#160;104</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.13" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_36e87dee-0951-4163-b343-caea32d7da45" valid.date="as.made" check="valid">s&#160;13</legref></txt></historynote></clause><clause id="sec.105" guid="_54aecab9-bd0c-4286-b814-15386ae1681d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>105</no><heading id="sec.105-he" guid="_66c1f1c3-5881-4d7b-b82f-6ae10ec82243">Monitoring particular types of on-site sewage facility—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.137" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8ffbcc80-9ff1-4665-8162-078ac1ff7d97" check="valid">s&#160;137</legref></heading><block><txt break.before="1">For <legref jurisd="QLD" type="act" refid="sec.137" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_8ffbcc80-9ff1-4665-8162-078ac1ff7d97" check="valid">section&#160;137</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the types of on-site sewage facilities are each on-site sewage facility that includes an on-site sewage treatment plant of a type for which a treatment plant testing approval has been granted.</txt></block></clause><clause id="sec.106" guid="_d8b9ab77-8c78-476f-b11c-7ba57d420630" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>106</no><heading id="sec.106-he" guid="_28d01dd5-2dcc-4be1-857e-426c692fe95d">Servicing greywater use or on-site sewage facilities</heading><subclause id="sec.106-ssec.1" guid="_6cf920be-1dec-4356-870a-f0491453801d" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A person who services a greywater use facility or on-site sewage facility must, within 10 business days after servicing the facility, give—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.106-ssec.1-para1.a" guid="_5aea5251-5a4d-438c-8c25-4c4591410111" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a service report to the owner of the facility; and</txt></block></li><li id="sec.106-ssec.1-para1.b" guid="_ca6403d7-2a03-45df-a4b8-3b489062cf6f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a copy of the service report to the local government.</txt></block></li></list><penalty id="sec.106-ssec.1-pen" guid="_01d72003-af5b-40fc-b7f1-7de9682d34ca"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause><subclause id="sec.106-ssec.2" guid="_f80efbff-0f8a-4801-b7a0-604fff2c5a36" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.106-ssec.2-def.servicereport_" guid="_49b6a1e5-cd68-4845-ab29-a859992ec185" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.106-ssec.2-def.servicereport" guid="_e11f28d5-f22f-464a-b157-357b68a3a382" type="definition">service report</defterm> means a report, in the approved form, about the condition of the facility.</txt></definition></deflist></block></subclause></clause><clause id="sec.107" guid="_274e6468-caf1-467a-9084-d01f5ac0dc0c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>107</no><heading id="sec.107-he" guid="_eb3ff431-0d52-4585-9ba2-3ec338d5c552">Maintenance of particular combined sanitary drains</heading><subclause id="sec.107-ssec.1" guid="_30d96f97-3791-400d-8a05-fc420a4b0be1" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.107-ssec.1-para1.a" guid="_34aa301a-ca2c-49a1-b9b1-d185c804aa85" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a combined sanitary drain serves 2 or more premises, other than body corporate premises; and </txt></block></li><li id="sec.107-ssec.1-para1.b" guid="_466f76c6-9f28-40d1-900f-eff50e546fea" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the drain is obstructed or damaged, including, for example, because of a tree root or a breakage; and </txt></block></li><li id="sec.107-ssec.1-para1.c" guid="_dd950122-9d6c-4d15-a8af-5d7a8439bae7" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the owners of the premises can not agree on suitable and fair arrangements for removing the obstruction or fixing the damage. </txt></block></li></list></block></subclause><subclause id="sec.107-ssec.2" guid="_06015837-d611-4a88-8416-1e33a9c0435b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.107-ssec.2-para1.a" guid="_9081d925-3b11-4918-b692-3fb2ea6f373f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">remove the obstruction or fix the damage; and </txt></block></li><li id="sec.107-ssec.2-para1.b" guid="_d6b775ad-845a-480a-9c47-de696f9e0b59" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">fairly apportion the reasonable cost of removing the obstruction or fixing the damage between the owners; and </txt></block></li><li id="sec.107-ssec.2-para1.c" guid="_a3820610-add2-46fa-92fa-02d9d2ae78fa" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">recover, as a debt from each owner, the owner’s share of the cost. </txt></block></li></list></block></subclause><subclause id="sec.107-ssec.3" guid="_8966d540-718f-44b1-8797-b16db1d52466" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.107-ssec.3-def.bodycorporatepremises_" guid="_a33c9c20-66ee-4860-a5ac-6469729fdf71" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.107-ssec.3-def.bodycorporatepremises" guid="_0f5e6cd1-2792-4cb6-9852-9fc5faf9d95d" type="definition">body corporate premises</defterm> means the lots, and any common property, included in—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.107-ssec.3-def.bodycorporatepremises-para1.a" guid="_276dd657-e3f8-4c42-90b3-11efb4f2bd0a" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a community titles scheme; or</txt></block></li><li id="sec.107-ssec.3-def.bodycorporatepremises-para1.b" guid="_9d94bc6c-bf2a-4453-ac6f-558c6c044bb7" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a plan under the <legref jurisd="QLD" type="act" target.doc.id="act-1980-042" target.version.series="db1baf67-e0e9-4aaa-88d6-6b0407d404c3" check="valid"><name emphasis="yes">Building Units and Group Titles Act 1980</name></legref>.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.108" guid="_85c88944-2b08-402c-81b5-1f9319c8a644" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>108</no><heading id="sec.108-he" guid="_5c132067-47c2-46e3-8fcb-73057ebf6b49">Vents in adjoining buildings</heading><subclause id="sec.108-ssec.1" guid="_283b52ad-bb4c-4f38-b05e-2066de5a3d38" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.108-ssec.1-para1.a" guid="_def21d16-8feb-4855-96e8-f6f5b4526fc8" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a building (the <defterm id="sec.108-ssec.1-def.newbuilding" guid="_59ecb92b-a366-4a16-836a-1d845dbb3a74" type="definition">new building</defterm>) is built next to another building of a lower height (the <defterm id="sec.108-ssec.1-def.oldbuilding" guid="_a9fa8f26-bdbd-4246-a437-0dafc8a1a0d2" type="definition">old building</defterm>); and </txt></block></li><li id="sec.108-ssec.1-para1.b" guid="_bc07e182-6f56-4a33-ae1b-013c2fbe38cc" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">because of the building work, it is necessary to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.108-ssec.1-para1.b-para2.i" guid="_20978a0a-010a-44b8-a6cf-a6c819fb6a08" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">carry out plumbing or drainage work affecting vents of the old building (the <defterm id="sec.108-ssec.1-para1.b-def.affectedvents" guid="_63b00409-4006-407e-8089-41290f516bac" type="definition">affected vents</defterm>); and </txt></block></li><li id="sec.108-ssec.1-para1.b-para2.ii" guid="_256ffa71-9c52-44a3-98b3-fade0a3252ec" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">change the affected vents to comply with the code requirements for the plumbing or drainage work. </txt></block></li></list></block></li></list></block></subclause><subclause id="sec.108-ssec.2" guid="_7e07b6ae-af4c-4680-8691-8fd506372c98" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may, by notice to the owner of the old building and the owner of the new building, require—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.108-ssec.2-para1.a" guid="_8f4e024e-b53c-4956-b61b-9ec45f12c708" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the owner of the old building to change the affected vents as required under <intref refid="sec.108-ssec.1" target.guid="_283b52ad-bb4c-4f38-b05e-2066de5a3d38" check="valid">subsection&#160;(1)</intref><intref refid="sec.108-ssec.1-para1.b" target.guid="_bc07e182-6f56-4a33-ae1b-013c2fbe38cc" check="valid">(b)</intref><intref refid="sec.108-ssec.1-para1.b-para2.ii" target.guid="_256ffa71-9c52-44a3-98b3-fade0a3252ec" check="valid">(ii)</intref>; and</txt></block></li><li id="sec.108-ssec.2-para1.b" guid="_84df49a2-4ece-4db7-a281-c1a9991c6910" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the owner of the new building to pay the owner of the old building the reasonable cost of changing the affected vents as mentioned in <intref refid="sec.108-ssec.2-para1.a" target.guid="_8f4e024e-b53c-4956-b61b-9ec45f12c708" check="valid">paragraph&#160;(a)</intref>.</txt></block></li></list></block></subclause><subclause id="sec.108-ssec.3" guid="_48c06239-38c3-4f45-908f-e169729a545e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The owner of a building who is given a notice under <intref refid="sec.108-ssec.2" target.guid="_7e07b6ae-af4c-4680-8691-8fd506372c98" check="valid">subsection&#160;(2)</intref> must comply with the notice, unless the owner has a reasonable excuse.</txt><penalty id="sec.108-ssec.3-pen" guid="_90802b2d-b905-47e0-93e8-56c58ce5f0e7"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></block></subclause><subclause id="sec.108-ssec.4" guid="_0ace4bd4-9cd4-437b-8f64-4fe19b3a8e01" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">However, the owner of the old building is not required to change the affected vents until the owner of the new building—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.108-ssec.4-para1.a" guid="_30f3b1d5-195d-4866-ab5c-aab9efba38b9" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">pays the owner of the old building the reasonable cost of changing the affected vents; or </txt></block></li><li id="sec.108-ssec.4-para1.b" guid="_2bf95e12-782c-4fae-8eb8-cb49039e8b73" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">gives the owner of the old building security, to the satisfaction of the old building’s owner, for the reasonable cost of changing the affected vents. </txt></block></li></list></block></subclause></clause></part><part id="pt.8" guid="_c3be9bae-31b8-48a4-8473-096a8d993496" affected.by.uncommenced="0"><no>Part 8</no><heading id="pt.8-he" guid="_ebc6f5cd-667a-4733-9199-87f9f2d208b6">Registers</heading><division id="pt.8-div.1" guid="_d46ef015-3f0a-4058-b60e-b68fbec553bb" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.8-div.1-he" guid="_08820903-4948-432b-9733-cefa8a3db5f0">Registers kept by commissioner</heading><clause id="sec.109" guid="_e539ac16-4d83-4409-af32-5907ec121a02" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>109</no><heading id="sec.109-he" guid="_97a01b0b-d0ca-4c3a-a3ed-bb09bb3b2bc6">Register of licensees—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.41" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a5c7514a-0e92-4739-9784-2e649db437c8" check="valid">s&#160;41</legref></heading><subclause id="sec.109-ssec.1" guid="_1d06dc92-c1db-4a18-a2cb-e260ef328dc0" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">For <legref jurisd="QLD" type="act" refid="sec.41" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_a5c7514a-0e92-4739-9784-2e649db437c8" check="valid">section&#160;41</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the particulars for each licensee are—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.109-ssec.1-para1.a" guid="_183f3186-cb8d-40b2-8aa3-5db758b1584d" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the licensee’s full name; and</txt></block></li><li id="sec.109-ssec.1-para1.b" guid="_e4c39bed-1337-42a4-b770-a3073bd068f8" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for each licence held by the licensee—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.109-ssec.1-para1.b-para2.i" guid="_603fb695-18ec-4331-9fe9-5aeabc17d5a4" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the class of the licence; and</txt></block></li><li id="sec.109-ssec.1-para1.b-para2.ii" guid="_91371073-6530-44d6-96d7-9370ca4aeb7e" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the licence number; and</txt></block></li><li id="sec.109-ssec.1-para1.b-para2.iii" guid="_fbfbe5bf-2dc5-4dd5-884e-8952b045a959" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">any conditions of the licence; and</txt></block></li><li id="sec.109-ssec.1-para1.b-para2.iv" guid="_936bcea5-be40-4c4e-a66a-5ca4c653a428" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">any endorsements on the licence; and</txt></block></li><li id="sec.109-ssec.1-para1.b-para2.v" guid="_69cbe2d7-654e-43ce-8f16-85d5d6061240" provision.type="other" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="0">the expiry date of the licence.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.109-ssec.2" guid="_cc477954-9159-4629-95cd-c9c4153148c1" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The commissioner must make the information mentioned in <intref refid="sec.109-ssec.1" target.guid="_1d06dc92-c1db-4a18-a2cb-e260ef328dc0" check="valid">subsection&#160;(1)</intref> available to the public on QBCC’s website.</txt></block></subclause></clause><clause id="sec.110" guid="_d4c6fe09-de14-4907-ab48-33c8c8ea935f" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>110</no><heading id="sec.110-he" guid="_5f11ef0e-bc05-4efa-95f1-f04b51f7cf60">Register of notices about notifiable work</heading><subclause id="sec.110-ssec.1" guid="_8586a4d1-ae4b-4c99-87fa-47d19c98d3c3" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The commissioner must keep a register of all notices given under <legref jurisd="QLD" type="act" refid="sec.83" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_04f65a58-00b2-4e56-81c7-c0eca16f3495" check="valid">section&#160;83</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>.</txt></block></subclause><subclause id="sec.110-ssec.2" guid="_b175f8b4-3c0c-4686-a34c-525c6364284e" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The commissioner must allow a person to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.110-ssec.2-para1.a" guid="_b5223d11-2e09-4974-b08b-bd46b3598e88" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">inspect the register, free of charge; or</txt></block></li><li id="sec.110-ssec.2-para1.b" guid="_169fd134-aa84-4cc3-9ccf-4da750435424" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">buy a copy of an entry in the register for not more than the reasonable cost of producing the copy.</txt></block></li></list></block></subclause><subclause id="sec.110-ssec.3" guid="_f6431ae3-bea7-4f8f-a5d2-ed6896a0d99a" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0"><intref refid="sec.110-ssec.2" target.guid="_b175f8b4-3c0c-4686-a34c-525c6364284e" check="valid">Subsection&#160;(2)</intref> is subject to <intref refid="sec.111" target.guid="_6df7741e-e872-4936-b22e-974038c8108f" check="valid">section&#160;111</intref>.</txt></block></subclause></clause><clause id="sec.111" guid="_6df7741e-e872-4936-b22e-974038c8108f" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>111</no><heading id="sec.111-he" guid="_1b148818-76bf-477b-8994-5e8aa17a9e00">Particular documents containing information to which public access is restricted—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.155" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_aee9a3db-3af8-4575-9ded-e1e4e79d76ea" check="valid">s&#160;155</legref></heading><block><txt break.before="1">A notice given to the commissioner under <legref jurisd="QLD" type="act" refid="sec.83" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_04f65a58-00b2-4e56-81c7-c0eca16f3495" check="valid">section&#160;83</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref> is prescribed for <legref jurisd="QLD" type="act" refid="sec.155" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_aee9a3db-3af8-4575-9ded-e1e4e79d76ea" check="valid">section&#160;155</legref><legref jurisd="QLD" type="act" check="invalid">(4)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>.</txt></block></clause></division><division id="pt.8-div.2" guid="_b9e6bf77-9367-4ed3-a7ec-752346bbeae0" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.8-div.2-he" guid="_8bbfa224-6ab9-412e-bffe-dbcb905d6305">Registers kept by local governments</heading><clause id="sec.112" guid="_f9483f54-855c-4c44-9326-44a2780d23e4" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>112</no><heading id="sec.112-he" guid="_0fa23f11-d564-4c51-99b3-925ea28e8bd8">Register of permits and inspection certificates</heading><subclause id="sec.112-ssec.1" guid="_b2bf5689-d8b3-4647-bfba-6888591332bd" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government must keep a register containing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.112-ssec.1-para1.a" guid="_4e1202cc-bddb-47d1-b607-98526c1f4c03" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the plans and other documents relating to each application for a permit made to the local government, including any plans amended under <intref refid="sec.75" target.guid="_b2564d33-2845-432b-9d2e-b6f3e6db935c" check="valid">section&#160;75</intref>; and</txt></block></li><li id="sec.112-ssec.1-para1.b" guid="_1df725f8-39cc-4624-a3de-2e2a3d89c414" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a copy of each permit issued by the local government; and</txt></block></li><li id="sec.112-ssec.1-para1.c" guid="_75054c1c-8c5d-4252-b0d8-4ea5e9db67f2" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a copy of each permit issued by a public sector entity and given to the local government under <intref refid="sec.54" target.guid="_663915cf-5ab1-4fab-9ef6-9ad57bf1a7b9" check="valid">section&#160;54</intref><intref refid="sec.54-para1.b" check="invalid">(b)</intref>; and</txt></block></li><li id="sec.112-ssec.1-para1.d" guid="_16ee95e2-1d7f-4a17-83f6-2030c151bb4e" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">a copy of each inspection certificate or final inspection certificate given by the local government; and</txt></block></li><li id="sec.112-ssec.1-para1.e" guid="_bcd0be49-0732-4982-b4c3-05b5988182c1" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">a copy of each final inspection certificate prepared by a public sector entity and given to the local government under <intref refid="sec.91" target.guid="_f6b054c3-b3ee-4b85-91b5-32da6130d976" check="valid">section&#160;91</intref><intref refid="sec.91-para1.c" check="invalid">(c)</intref>.</txt></block></li></list></block></subclause><subclause id="sec.112-ssec.2" guid="_00c14fdb-9be5-407c-b2ca-2e99e278d104" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must keep a document mentioned in <intref refid="sec.112-ssec.1" target.guid="_b2bf5689-d8b3-4647-bfba-6888591332bd" check="valid">subsection&#160;(1)</intref> in the register until the building or structure to which the document relates is demolished or removed.</txt></block></subclause></clause><clause id="sec.113" guid="_2c1a609e-7b72-435f-960c-450a4a73a647" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>113</no><heading id="sec.113-he" guid="_437eedbf-a379-459c-9815-aa1e2d8cde54">Register of testable backflow prevention devices</heading><subclause id="sec.113-ssec.1" guid="_eda2a26e-75c7-4ad7-bd55-1b6473f4750a" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government must keep a register containing each notice given to the local government under <intref refid="sec.102" target.guid="_7aaa282e-51e1-4b3a-b693-7ba1df4b3c90" check="valid">section&#160;102</intref><intref refid="sec.102-ssec.2" target.guid="_39b3097c-313d-463e-9411-7feac7e14cf9" check="valid">(2)</intref> or <intref refid="sec.103" target.guid="_505db557-644f-40d3-8746-cc615c2695d0" check="valid">103</intref><intref refid="sec.103-ssec.3" target.guid="_03eee920-18ac-4c88-b882-bef7521ad672" check="valid">(3)</intref>.</txt></block></subclause><subclause id="sec.113-ssec.2" guid="_c242926f-f359-46a6-99a8-2edb418bbc13" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must keep a notice mentioned in <intref refid="sec.113-ssec.1" target.guid="_eda2a26e-75c7-4ad7-bd55-1b6473f4750a" check="valid">subsection&#160;(1)</intref> in the register until the premises to which the notice relates are demolished or removed.</txt></block></subclause></clause><clause id="sec.114" guid="_16061f5b-b145-4393-b9f3-8f3647825b7c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>114</no><heading id="sec.114-he" guid="_68dbb1e5-30c6-46f7-89f7-63704e65513c">Register for greywater use and on-site sewage facilities</heading><subclause id="sec.114-ssec.1" guid="_6a62423f-0099-4efe-807c-e2143bdecd72" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government must keep a register containing a copy of each service report for a greywater use facility or on-site sewage facility given to the local government under <intref refid="sec.106" target.guid="_d8b9ab77-8c78-476f-b11c-7ba57d420630" check="valid">section&#160;106</intref>.</txt></block></subclause><subclause id="sec.114-ssec.2" guid="_d1602221-68df-4a59-80ae-d4d9db785828" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must keep a copy of a service report mentioned in <intref refid="sec.114-ssec.1" target.guid="_6a62423f-0099-4efe-807c-e2143bdecd72" check="valid">subsection&#160;(1)</intref> in the register until the greywater use facility or on-site sewage facility to which the report relates is demolished or removed.</txt></block></subclause></clause><clause id="sec.115" guid="_750bf99c-a449-4200-b960-033236115513" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>115</no><heading id="sec.115-he" guid="_479f86b7-bc38-44c0-a310-ecae876c3033">Register of show cause and enforcement notices</heading><subclause id="sec.115-ssec.1" guid="_78518c6e-e27a-49fa-822c-898cc0a18c25" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government must keep a register containing a copy of each show cause notice and enforcement notice given by the local government.</txt></block></subclause><subclause id="sec.115-ssec.2" guid="_c1484947-12d5-4e80-aaf1-24849eaaf6b5" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may remove a notice mentioned in <intref refid="sec.115-ssec.1" target.guid="_78518c6e-e27a-49fa-822c-898cc0a18c25" check="valid">subsection&#160;(1)</intref> from the register if the premises to which the notice relates are demolished or removed.</txt></block></subclause></clause><clause id="sec.116" guid="_dba8c031-f642-41b4-bdf3-bb202beaa048" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>116</no><heading id="sec.116-he" guid="_801b3ab1-49f6-4dc9-b779-829cf9e1d6df">Public access to registers</heading><subclause id="sec.116-ssec.1" guid="_367b69bf-26de-49e6-82de-21eae2be1f4e" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies in relation to a register kept by a local government under this division.</txt></block></subclause><subclause id="sec.116-ssec.2" guid="_721f3968-dbb6-47f7-911a-ec6fabd7fa0b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government must allow a person to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.116-ssec.2-para1.a" guid="_84289a62-5d8e-4be3-88ad-5044ede1c971" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">inspect the register, free of charge, at the local government’s public office; or</txt></block></li><li id="sec.116-ssec.2-para1.b" guid="_34099dcc-feb0-4a00-af72-7eba9e8c3077" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">buy a copy of an entry in the register for not more than the reasonable cost of producing the copy. </txt></block></li></list></block></subclause><subclause id="sec.116-ssec.3" guid="_b9d474b4-4dfd-4b58-9c2e-cf778a625c44" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0"><intref refid="sec.116-ssec.2" target.guid="_721f3968-dbb6-47f7-911a-ec6fabd7fa0b" check="valid">Subsection&#160;(2)</intref> is subject to <intref refid="sec.117" target.guid="_d75d2e1b-403d-4bc5-a494-1616158ed088" check="valid">section&#160;117</intref>.</txt></block></subclause></clause><clause id="sec.117" guid="_d75d2e1b-403d-4bc5-a494-1616158ed088" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>117</no><heading id="sec.117-he" guid="_63ce126b-488c-4629-95e7-c20bcc3de2a6">Particular documents containing information to which public access is restricted—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.155" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_aee9a3db-3af8-4575-9ded-e1e4e79d76ea" check="valid">s&#160;155</legref></heading><block><txt break.before="1">A register kept under this division is prescribed for <legref jurisd="QLD" type="act" refid="sec.155" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_aee9a3db-3af8-4575-9ded-e1e4e79d76ea" check="valid">section&#160;155</legref><legref jurisd="QLD" type="act" check="invalid">(4)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>.</txt></block></clause></division></part><part id="pt.9" guid="_03e1440b-60d0-42e5-9b5d-64440359a3d9" affected.by.uncommenced="0"><no>Part 9</no><heading id="pt.9-he" guid="_5ef8c4af-389b-41de-9e57-e5f8ac2cf6a1">Miscellaneous provisions</heading><division id="pt.9-div.1" guid="_70ea5776-007b-4109-a70e-a06a874b832b" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.9-div.1-he" guid="_64ab6a55-8215-415e-ba10-d6d100c39311">Fees</heading><clause id="sec.118" guid="_0d3484a9-644a-46d0-92f7-3f0e137b728a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>118</no><heading id="sec.118-he" guid="_d218f1b0-55cd-4f7d-bef5-7e8fa319e196">Fees payable to QBCC</heading><subclause id="sec.118-ssec.1" guid="_5d3d24be-c72b-44e2-a046-ecdc9e8ed284" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0"><intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">Schedule&#160;8</intref> sets out the fees payable to QBCC for the matters stated in the schedule.</txt></block></subclause><subclause id="sec.118-ssec.2" guid="_835bdc31-05bd-4a26-bbe1-4cf2db55cb4f" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">This section is subject to <intref refid="sec.119" target.guid="_9443934a-c6dd-4099-9c73-dc9d30cdc00b" check="valid">sections&#160;119</intref> to <intref refid="sec.123" target.guid="_d89395bc-d229-4aa6-bb5c-4e69199d8d14" check="valid">123</intref>.</txt></block></subclause></clause><clause id="sec.119" guid="_9443934a-c6dd-4099-9c73-dc9d30cdc00b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>119</no><heading id="sec.119-he" guid="_6ffa15c5-a04f-45eb-a343-3c750ba24538">Fee not payable for application for occupational licence for which there is an associated QBCCA licence </heading><subclause id="sec.119-ssec.1" guid="_6e3d7e28-da5e-4de4-9d5a-ec0540591c00" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a person makes an application (the <defterm id="sec.119-def.relevantapplication" guid="_5dd701fc-4ef2-435b-927e-72db381dbe3f" type="definition">relevant application</defterm>) for the grant, renewal or restoration of a licence (the <defterm id="sec.119-def.occupationallicence" guid="_e24d9675-de06-4b99-824c-0a7636f633ae" type="definition">occupational licence</defterm>) mentioned in <intref refid="sch.9" target.guid="_5ab2a027-321a-4d67-8d54-fa015469136e" check="valid">schedule&#160;9</intref>, column 1.</txt></block></subclause><subclause id="sec.119-ssec.2" guid="_e7fa3a7b-e20b-438e-8185-731fcf7b75e4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the person holds an associated QBCCA licence for the occupational licence, no fee is payable for the relevant application for the occupational licence.</txt></block></subclause><subclause id="sec.119-ssec.3" guid="_b6412c3e-cb61-4a4b-b24c-9febc3efdd77" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0"><intref refid="sec.119-ssec.4" target.guid="_929cab77-6652-4796-9840-dd5c646ad9d5" check="valid">Subsections&#160;(4)</intref> and <intref refid="sec.119-ssec.5" target.guid="_368e0e4b-18f7-49f0-8b69-504ce26cbfeb" check="valid">(5)</intref> apply if the person—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.119-ssec.3-para1.a" guid="_1c48dacf-7519-47b0-acf1-8947149d471e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">does not hold an associated QBCCA licence for the occupational licence; and </txt></block></li><li id="sec.119-ssec.3-para1.b" guid="_f0a8eec7-a291-44e3-9612-4bbfe4d8a404" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">has applied for, or asked for the restoration of, an associated QBCCA licence for the occupational licence under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref>, <legref jurisd="QLD" type="act" refid="sec.33" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" target.guid="_f7a23e79-ccdc-4b1d-80c9-ea35842fed00" check="valid">section&#160;33</legref> or <legref jurisd="QLD" type="act" refid="sec.39" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" target.guid="_03efb328-f473-4d1c-baac-2ec4d9d9f8c6" check="valid">39</legref> (each the <defterm id="sec.119-ssec.3-def.QBCCAapplication" guid="_16c36a8e-88b0-4102-9871-263235aed08a" type="definition">QBCCA application</defterm>).</txt></block></li></list></block></subclause><subclause id="sec.119-ssec.4" guid="_929cab77-6652-4796-9840-dd5c646ad9d5" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The person is not required to pay the fee that would, other than for this section, be payable for the relevant application for the occupational licence unless the QBCCA application is refused.</txt></block></subclause><subclause id="sec.119-ssec.5" guid="_368e0e4b-18f7-49f0-8b69-504ce26cbfeb" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">If the QBCCA application is refused and the commissioner gives the person notice of the refusal, the person must pay the fee for the relevant application for the occupational licence within 5 business days after being given the notice.</txt></block></subclause><subclause id="sec.119-ssec.6" guid="_aa65a225-8973-4fe9-9dc2-5686a5f5891b" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.119-ssec.6-def.associatedQBCCAlicence_" guid="_7e363589-0477-4272-97c7-c623329c54f7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.119-ssec.6-def.associatedQBCCAlicence" guid="_70e19b80-d23c-4668-afd6-1169eeacd2b5" type="definition">associated QBCCA licence</defterm>, for an occupational licence mentioned in <intref refid="sch.9" target.guid="_5ab2a027-321a-4d67-8d54-fa015469136e" check="valid">schedule&#160;9</intref>, column 1, means a QBCCA licence of the class mentioned opposite the occupational licence in column 2 of the schedule.</txt></definition><definition id="sec.119-ssec.6-def.QBCCAlicence_" guid="_04a098a9-2ef1-47c6-9d27-bcc8d8306fcc" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.119-ssec.6-def.QBCCAlicence" guid="_762a2536-ad03-4e3d-b68b-5b4b0645b552" type="definition">QBCCA licence</defterm> means a contractor’s licence, nominee supervisor’s licence, site supervisor’s licence or mechanical services occupational licence under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name>.</legref></txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;119</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2019-0213" target.version.series="cccda14b-0e9f-4e05-8b5f-d02a20f13755" valid.date="as.made" check="valid">2019 SL&#160;No.&#160;213</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2019-0213" target.version.series="cccda14b-0e9f-4e05-8b5f-d02a20f13755" target.guid="_913900f2-9cc6-49a8-a1d9-d7f64aa369e2" valid.date="as.made" check="valid">s&#160;4</legref></txt></historynote></clause><clause id="sec.120" guid="_8afe6660-9f17-4950-9b30-b53ac20d67d6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>120</no><heading id="sec.120-he" guid="_a026c39d-da5b-47bd-ae9d-90055529e5fb">Reduced application fee payable for later licence</heading><subclause id="sec.120-ssec.1" guid="_27c68056-d31e-43ca-ae6c-0203c99e9bf1" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.120-ssec.1-para1.a" guid="_48cbe757-5f61-4b81-a789-654467eb8c96" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person is the holder of a licence (the <defterm id="sec.120-ssec.1-def.firstlicence" guid="_e865dbe0-7427-4082-96d3-e03c023cccc3" type="definition">first licence</defterm>) that has been granted for at least 1 year; and</txt></block></li><li id="sec.120-ssec.1-para1.b" guid="_d4ebf605-feff-47f1-b956-40c8491199d3" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the person applies for another licence (a <defterm id="sec.120-ssec.1-def.laterlicence" guid="_b04ede35-39cb-4003-a23a-1f8cddd95530" type="definition">later licence</defterm>) for the period ending at the end of the day the first licence expires.</txt></block></li></list></block></subclause><subclause id="sec.120-ssec.2" guid="_5dbdcc50-16a4-4b94-9498-dc5c7cb9326b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The fee payable for the application for the later licence is the relevant fee regardless of the period for which the licence is proposed to be granted.</txt></block></subclause><subclause id="sec.120-ssec.3" guid="_51206c5d-5676-4e34-a016-a238b375354f" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.120-ssec.3-def.relevantfee_" guid="_02ce2cb6-2dc2-4c32-8a35-ee572a357e8d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.120-ssec.3-def.relevantfee" guid="_7305fc62-f58a-4a13-b016-e3431c22fa97" type="definition">relevant fee</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.120-ssec.3-def.relevantfee-para1.a" guid="_7d0ea058-c92a-4d2c-908b-58b7e4e6375d" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for an application for a later licence that is a plumbers licence—the fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 1(a); or</txt></block></li><li id="sec.120-ssec.3-def.relevantfee-para1.b" guid="_bbc10a0f-c96e-4905-a5a8-fe7af661a238" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for an application for a later licence that is a drainers licence—the fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 2(a); or</txt></block></li><li id="sec.120-ssec.3-def.relevantfee-para1.c" guid="_9eb7e34a-e8e4-4b90-99af-f11930a9b78f" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for an application for a later licence that is a restricted licence—the fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 4(a).</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.121" guid="_e69d738c-80ef-435a-9497-4cdfeed9c87e" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>121</no><heading id="sec.121-he" guid="_b4de4528-f791-4b61-8569-d731f5589f31">Application fee not payable for renewing or restoring additional licences</heading><subclause id="sec.121-ssec.1" guid="_202ff00e-bcf9-4a64-b5fb-4d2fca643f45" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a person—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.121-ssec.1-para1.a" guid="_279f374c-1cc0-4d15-8364-1deb8b87ee31" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">applies to renew or restore 2 or more licences in the same application; and</txt></block></li><li id="sec.121-ssec.1-para1.b" guid="_8a72f758-e75c-4511-abcd-af0715df35f7" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">pays the highest application fee for renewing or restoring 1 of the licences.</txt></block></li></list></block></subclause><subclause id="sec.121-ssec.2" guid="_97b5d769-1799-4d01-8d95-ff5257078784" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The person is not required to pay the application fee for renewing or restoring any of the other licences.</txt></block></subclause><subclause id="sec.121-ssec.3" guid="_82f4e829-9083-411c-95bd-de687b45f205" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.121-ssec.3-def.applicationfee_" guid="_04d709ea-22e6-481b-b02a-f77de847ab89" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.121-ssec.3-def.applicationfee" guid="_b8867568-93dd-4f22-a024-cad67458f162" type="definition">application fee</defterm>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.121-ssec.3-def.applicationfee-para1.a" guid="_b04ca0f4-4e19-4d44-b2ae-b138b9ea9f0e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for renewing a licence—means the relevant fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 8 for an application to renew the licence; or</txt></block></li><li id="sec.121-ssec.3-def.applicationfee-para1.b" guid="_ea9e571e-5e98-4043-829d-dd9acfc57a1c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for restoring a licence—means the relevant fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 8 for an application to restore the licence.</txt></block></li></list></definition><definition id="sec.121-ssec.3-def.highestapplicationfee_" guid="_dd9d5253-1075-4e5e-b304-cf773402a641" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.121-ssec.3-def.highestapplicationfee" guid="_a9e767d3-1e4c-411d-a6e6-c3e89c535be4" type="definition">highest application fee</defterm>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.121-ssec.3-def.highestapplicationfee-para1.a" guid="_9470438a-11ed-4610-a4af-718c4130bb1c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for renewing a licence—means the application fee for renewing the licence that is equal to, or more than, the application fee for renewing each of the other licences; or</txt></block></li><li id="sec.121-ssec.3-def.highestapplicationfee-para1.b" guid="_b9ef515c-d7ea-441d-9bbb-66cd0453ff48" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for restoring a licence—means the application fee for restoring the licence that is equal to, or more than, the application fee for restoring each of the other licences.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sec.122" guid="_aef64642-0c2a-4705-9bc0-1a99b7c981ae" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>122</no><heading id="sec.122-he" guid="_a52b05bb-8daa-4fcc-8e76-28964eda3133">Additional application fee for restoring a licence</heading><subclause id="sec.122-ssec" guid="_6c5c927c-91b1-4075-b96d-b3d16ef55698" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">If a person applies to restore a licence, the person must pay the fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 9 for the application in addition to the relevant fee for the application mentioned in item 8 of the schedule.</txt></block></subclause></clause><clause id="sec.123" guid="_d89395bc-d229-4aa6-bb5c-4e69199d8d14" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>123</no><heading id="sec.123-he" guid="_dc75e328-a861-4888-81bf-e3706a887b8e">Administration fee for relevant application or request</heading><subclause id="sec.123-ssec.1" guid="_5af66bda-da62-48f3-8d37-2c144792b2c6" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0"><intref refid="sec.123-ssec.2" target.guid="_cd65acab-d093-4d4b-a8fb-b76c9504f3ae" check="valid">Subsection&#160;(2)</intref> applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.123-ssec.1-para1.a" guid="_d3f4e388-51c4-4757-8146-85588a890aa4" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person makes a relevant application or relevant request; and </txt></block></li><li id="sec.123-ssec.1-para1.b" guid="_977199cb-f1c5-4415-aaa4-91c20bd0cf9a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the designated fee for the application or request is payable.</txt></block></li></list></block></subclause><subclause id="sec.123-ssec.2" guid="_cd65acab-d093-4d4b-a8fb-b76c9504f3ae" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The person must pay the administration fee for the relevant application or relevant request in addition to the designated fee for the application or request.</txt></block></subclause><subclause id="sec.123-ssec.3" guid="_5d5418ca-d40d-4140-9131-d91148523edb" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0"><intref refid="sec.123-ssec.4" target.guid="_96154419-a8b1-4bd2-98a2-52bde7ca21b9" check="valid">Subsection&#160;(4)</intref> applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.123-ssec.3-para1.a" guid="_53b72a63-94f4-452b-a58e-4c0742e43b0f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person makes a relevant application or relevant request and pays the designated fee and administration fee for the application or request; and</txt></block></li><li id="sec.123-ssec.3-para1.b" guid="_57b10064-349d-4096-9cf4-9aa1ecb82ac4" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">in the same financial year as the person made the application or request, the person makes another relevant application (the <defterm id="sec.123-ssec.3-def.laterapplication" guid="_e022fdf8-b183-468e-ac04-2873a9ca7880" type="definition">later application</defterm>) or relevant request (the <defterm id="sec.123-ssec.3-def.laterrequest" guid="_cf7e4d41-feab-4b38-a7ae-0324651ebf58" type="definition">later request</defterm>).</txt></block></li></list></block></subclause><subclause id="sec.123-ssec.4" guid="_96154419-a8b1-4bd2-98a2-52bde7ca21b9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">Despite <intref refid="sec.123-ssec.1" target.guid="_5af66bda-da62-48f3-8d37-2c144792b2c6" check="valid">subsections&#160;(1)</intref> and <intref refid="sec.123-ssec.2" target.guid="_cd65acab-d093-4d4b-a8fb-b76c9504f3ae" check="valid">(2)</intref>, the administration fee for the later application or later request is not payable by the person.</txt></block><note id="sec.123-ssec.4-note" guid="_11e9ca59-b251-4f6e-b000-1919c9d61c76" type="example"><heading id="sec.123-ssec.4-note-he" guid="_a312443e-3373-4b03-a3f9-539ce9ea8bd4">Example—</heading><block><txt break.before="1">A person applies for a plumbers licence for 2 years, pays the application fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 1(b) and the administration fee, and is granted the licence. The person applies for an endorsement on the licence in the same financial year as the person applied for the licence. The person is not required to pay the administration fee for the endorsement.</txt></block></note></subclause><subclause id="sec.123-ssec.5" guid="_dbc84092-97ce-4a12-8b6a-3d1ac7a885ca" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.123-ssec.5-def.administrationfee_" guid="_ab71285d-1661-4619-bf36-c7143a18e948" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.123-ssec.5-def.administrationfee" guid="_3521c627-dab5-48cf-8d2c-f2603bcb29c6" type="definition">administration fee</defterm> means the fee mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 13.</txt></definition><definition id="sec.123-ssec.5-def.designatedfee_" guid="_506b3b60-a3be-435b-ab4f-c7250da5e58d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.123-ssec.5-def.designatedfee" guid="_15e2f91d-d32a-4845-be68-36792479781f" type="definition">designated fee</defterm>, for a relevant application or relevant request, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.123-ssec.5-def.designatedfee-para1.a" guid="_abd241ca-f0e3-4a02-8a5f-de9afa86cbdc" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the applicable fee mentioned opposite the application or request in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>; or</txt></block></li><li id="sec.123-ssec.5-def.designatedfee-para1.b" guid="_517fad1d-b024-4f05-bf5f-114dd0c51852" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the fee for the relevant application is the fee payable under <intref refid="sec.120" target.guid="_8afe6660-9f17-4950-9b30-b53ac20d67d6" check="valid">section&#160;120</intref>—that fee.</txt></block></li></list></definition><definition id="sec.123-ssec.5-def.relevantapplication_" guid="_b52e3e4a-7e86-4a65-a78e-b602f75bddbc" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.123-ssec.5-def.relevantapplication" guid="_fb1d755a-e2c7-4939-b785-6cd4455bb2c3" type="definition">relevant application</defterm> means an application mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 1, 2, 3, 4, 6, 7, 8, 10 or 11.</txt></definition><definition id="sec.123-ssec.5-def.relevantrequest_" guid="_959520a7-2aef-4110-b191-66665f451b1e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.123-ssec.5-def.relevantrequest" guid="_795bd7cf-3fee-4756-986e-59796daa82ad" type="definition">relevant request</defterm> means a request mentioned in <intref refid="sch.8" target.guid="_93f0760f-c5c7-4977-b728-2912f08722ee" check="valid">schedule&#160;8</intref>, item 5 or 12.</txt></definition></deflist></block></subclause></clause></division><division id="pt.9-div.2" guid="_f7bfaaab-b3fd-4546-a20a-11a2db5d0051" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.9-div.2-he" guid="_6c1be207-cea4-4c6c-a5f7-50f517c67087">Other matters</heading><clause id="sec.124" guid="_d11dc7db-c97b-45f2-8a77-8357328efb76" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>124</no><heading id="sec.124-he" guid="_4538669f-7593-496e-b30b-c3f368203ba8">Qualifications and experience for appointment as inspector—<legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, <legref jurisd="QLD" type="act" refid="sec.139" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_0311a2d6-a31a-48be-8bf2-8f82deac187b" check="valid">s&#160;139</legref></heading><subclause id="sec.124-ssec.1" guid="_b22f509f-a5a5-4fc7-9fa6-bf1f0581f0a8" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section prescribes, for <legref jurisd="QLD" type="act" refid="sec.139" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_0311a2d6-a31a-48be-8bf2-8f82deac187b" check="valid">section&#160;139</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, the qualifications and experience an authorised person must have to be appointed by a local government as an inspector.</txt></block></subclause><subclause id="sec.124-ssec.2" guid="_42292a3c-a0e3-4eb7-8e01-19d427738f75" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the authorised person is to assess plans for, or inspect, plumbing work, the person must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.124-ssec.2-para1.a" guid="_d2146511-e662-4f9c-81be-caa5b85ca6c5" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">hold a plumbers licence; or </txt></block></li><li id="sec.124-ssec.2-para1.b" guid="_e195ba22-bca0-4dd8-bf0b-f5118ad4fee0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">have other qualifications and experience the local government considers necessary to enable the person to assess plans for, or inspect, plumbing work competently.</txt></block></li></list></block></subclause><subclause id="sec.124-ssec.3" guid="_72616818-c2a5-4c17-94cf-41885ea5f2c7" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the authorised person is to assess plans for, or inspect, drainage work, the person must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.124-ssec.3-para1.a" guid="_a18f189a-70d1-4aed-9589-5278cd62dda8" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">hold a drainers licence; or </txt></block></li><li id="sec.124-ssec.3-para1.b" guid="_26897f97-9177-47ae-bf5a-15ce4b2ff71f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">have other qualifications and experience the local government considers necessary to enable the person to assess plans for, or inspect, drainage work competently.</txt></block></li></list></block></subclause><subclause id="sec.124-ssec.4" guid="_504fe9e3-340c-4841-aa7d-66afa4e88e82" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the authorised person is to assess plans for, or inspect, on-site sewage facilities, the person must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.124-ssec.4-para1.a" guid="_be12eae0-44b7-4ffe-b797-ef7db825f810" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">hold a drainers licence with an endorsement for on-site sewage facility maintenance; or </txt></block></li><li id="sec.124-ssec.4-para1.b" guid="_356b3355-8ba8-49a0-90c3-b41350a66dab" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">hold a restricted licence for a drainer—on-site sewage facility; or </txt></block></li><li id="sec.124-ssec.4-para1.c" guid="_ca9e4131-4253-47fc-9b0b-9d2ebcdd87d7" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">have other qualifications and experience the local government considers necessary to enable the person to assess plans for, or inspect, on-site sewage facilities competently. </txt></block></li></list></block></subclause></clause><clause id="sec.125" guid="_3c61a858-b78c-4686-94c2-a85fbd9641d6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>125</no><heading id="sec.125-he" guid="_4439caba-f214-450e-a382-984f7d03284e">Evidentiary aids</heading><block><txt break.before="1">In a proceeding for <intref refid="sec.107" target.guid="_274e6468-caf1-467a-9084-d01f5ac0dc0c" check="valid">section&#160;107</intref><intref refid="sec.107-ssec.2" target.guid="_06015837-d611-4a88-8416-1e33a9c0435b" check="valid">(2)</intref><intref refid="sec.107-ssec.2-para1.c" target.guid="_a3820610-add2-46fa-92fa-02d9d2ae78fa" check="valid">(c)</intref>, a certificate purporting to be signed by the chief executive officer of a local government stating any of the following matters is evidence of the matter—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.125-para1.a" guid="_1b669cb1-890d-436a-b8f8-472d149eef4b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a matter mentioned in <intref refid="sec.107" target.guid="_274e6468-caf1-467a-9084-d01f5ac0dc0c" check="valid">section&#160;107</intref><intref refid="sec.107-ssec.1" target.guid="_30d96f97-3791-400d-8a05-fc420a4b0be1" check="valid">(1)</intref>;</txt></block></li><li id="sec.125-para1.b" guid="_fd5faf59-dffb-4f1a-a60f-812b601f7da8" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">that stated work was carried out under <intref refid="sec.107" target.guid="_274e6468-caf1-467a-9084-d01f5ac0dc0c" check="valid">section&#160;107</intref><intref refid="sec.107-ssec.2" target.guid="_06015837-d611-4a88-8416-1e33a9c0435b" check="valid">(2)</intref><intref refid="sec.107-ssec.2-para1.a" target.guid="_9081d925-3b11-4918-b692-3fb2ea6f373f" check="valid">(a)</intref>;</txt></block></li><li id="sec.125-para1.c" guid="_bb60cd12-f62b-4ec9-a139-ba767f775836" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">that a stated apportionment of cost under <intref refid="sec.107" target.guid="_274e6468-caf1-467a-9084-d01f5ac0dc0c" check="valid">section&#160;107</intref><intref refid="sec.107-ssec.2" target.guid="_06015837-d611-4a88-8416-1e33a9c0435b" check="valid">(2)</intref><intref refid="sec.107-ssec.2-para1.b" target.guid="_d6b775ad-845a-480a-9c47-de696f9e0b59" check="valid">(b)</intref> is a fair apportionment of the cost.</txt></block></li></list></block></clause></division></part></body></wrapper><schedules affected.by.uncommenced="0" numbering.style="manual"><schedule id="sch.1" guid="_403e71c5-3ea2-4acb-b879-b60f7efbc877" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 1</no><heading id="sch.1-he" guid="_e795026c-ab36-46dd-8233-fe0c3cc320b6">Notifiable work</heading><sourceref id="sch.1-ref" guid="_8c49dce8-e608-4de3-988c-1b16eca55138" affected.by.uncommenced="0"><intref refid="sec.5" target.guid="_7cf752a0-af01-4d7b-844d-d2760780bad9" check="valid">section&#160;5</intref></sourceref><part id="sch.1-pt.1" guid="_546e76c5-9f7b-4817-a214-e1b2afbb7759" affected.by.uncommenced="0"><no>Part 1</no><heading id="sch.1-pt.1-he" guid="_57b5f7e1-4928-4626-baad-64a76a1d4a78">Excluded work</heading><clause id="sch.1-sec.1" guid="_18f2fe99-e477-46a0-9a97-a1adbc2802d3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>1</no><heading id="sch.1-sec.1-he" guid="_f5878433-c62f-4cdf-99af-d548580722cc">Particular work not included as notifiable work</heading><subclause id="sch.1-sec.1-ssec" guid="_0e62ab0d-2e7d-4a45-bb4b-479029ef865b" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="0">Plumbing or drainage work of the type stated in <intref refid="pt.2" target.guid="_058799b3-38b1-47e0-8209-88b3d917626d" check="valid">part&#160;2</intref> is not notifiable work if the work is—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.1-ssec-para1.a" guid="_3fcac2d7-9dbf-46ca-8591-b6c9ed0f025b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">installing an appliance or fixture in a building that is connected to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.1-ssec-para1.a-para2.i" guid="_3de1f3fd-f95b-48b5-8ed2-223ef9e312f2" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a combined sanitary drain; or</txt></block></li><li id="sch.1-sec.1-ssec-para1.a-para2.ii" guid="_753b1f85-fbc7-427c-851a-c763a2006f1a" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">a dual reticulated water supply provided by a water service provider; or</txt></block></li></list></block></li><li id="sch.1-sec.1-ssec-para1.b" guid="_d89af7e9-e579-4bd4-8e9a-196402ba0646" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">work for, or connected to, trade waste; or</txt></block></li><li id="sch.1-sec.1-ssec-para1.c" guid="_e66bae2e-8007-4947-bfb7-b40881e551a2" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">work that uses a performance solution.</txt></block></li></list></block></subclause></clause></part><part id="sch.1-pt.2" guid="_805e0b7f-1871-4d8d-97f0-db43ebb0a8b5" affected.by.uncommenced="0" numbering.style="manual"><no>Part 2</no><heading id="sch.1-pt.2-he" guid="_80944291-2c15-489b-aeee-df8c50cee6d1">Included work </heading><clause id="sch.1-sec.1-oc.2" guid="_eefa86d5-e642-486d-87eb-883d0dd7c81d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>1</no><heading id="sch.1-sec.1-oc.2-he" guid="_b9b0767e-a269-4f26-8ef6-bc8bc1a4aeb1">Extending etc. supply pipes</heading><subclause id="sch.1-sec.1-oc.2-ssec" guid="_53b602fa-4298-4ff9-9743-769b70a331a1" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">work necessary for extending, altering, replacing or removing supply pipes, other than supply pipes for a fire service, if the work is for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.1-oc.2-ssec-para1" guid="_76f34210-7308-49be-abf9-7889a68182dc" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an existing building; or</txt></block></li><li id="sch.1-sec.1-oc.2-ssec-para1-oc.2" guid="_26fc16a1-619b-4248-8335-a0af867ccd4f" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an extension to an existing class 1 building; or</txt></block></li><li id="sch.1-sec.1-oc.2-ssec-para1-oc.3" guid="_54535864-2849-4200-b33c-e6843a636077" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a structure for an existing class 1 building</txt></block></li></list></block></subclause></clause><clause id="sch.1-sec.2" guid="_1f8cf19d-815a-41c8-88db-fc935e7629ee" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>2</no><heading id="sch.1-sec.2-he" guid="_3ecc7e4a-79eb-4458-9450-16eefb71587b">Fire services</heading><block><txt break.before="1">work necessary for extending or removing a fire service, if the work is—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.2-para1" guid="_62c96d87-b7aa-45c3-819e-31eb51025a32" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">associated with a building development approval under the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref>, <legref jurisd="QLD" type="act" refid="sch.2" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" target.guid="_eb2bfe4c-13cb-46ab-9188-07fe0a4b31c8" check="valid">schedule&#160;2</legref>; and</txt></block></li><li id="sch.1-sec.2-para1-oc.2" guid="_c849ea53-22fe-4529-9d09-7889d9bc6ffb" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">for an existing class 2 to 9 building</txt></block></li></list></block></clause><clause id="sch.1-sec.3" guid="_f68e5fd4-8482-468d-9ebc-7e1bf93a6148" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>3</no><heading id="sch.1-sec.3-he" guid="_010c5f66-eddf-4350-b637-b44e177d2a58">Existing sanitary plumbing</heading><block><txt break.before="1">work necessary for extending, altering, replacing or removing sanitary plumbing, if the work is for an existing building</txt></block></clause><clause id="sch.1-sec.4" guid="_0376d771-8cc1-419e-9758-ab82f6d089d3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4</no><heading id="sch.1-sec.4-he" guid="_542f4b88-d159-41cd-b8b9-67e82467748f">Existing sanitary drainage</heading><block><txt break.before="1">work necessary for extending, altering, replacing or removing sanitary drainage, other than a combined sanitary drain, if the work is for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.4-para1" guid="_a3253a57-09fd-4904-b7ba-b1069bbdc445" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an existing class 1 or 10 building or structure; or</txt></block></li><li id="sch.1-sec.4-para1-oc.2" guid="_110d6856-1074-4b40-94dc-245cee0811a4" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an extension to an existing class 1 building; or</txt></block></li><li id="sch.1-sec.4-para1-oc.3" guid="_239765c5-d21b-445d-accf-4b7c298732a8" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a structure for an existing class 1 building</txt></block></li></list></block></clause><clause id="sch.1-sec.5" guid="_533ffb55-951a-4c5c-8050-ec6d25097ae1" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>5</no><heading id="sch.1-sec.5-he" guid="_66f77aeb-ee84-4865-a289-389330b60e10">Temperature control devices</heading><block><txt break.before="1">work necessary for installing, replacing or removing a temperature control device, if the work is for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.5-para1" guid="_998c5801-6b45-469d-aa50-ef9d7808be11" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an existing building; or</txt></block></li><li id="sch.1-sec.5-para1-oc.2" guid="_8089c731-5036-492b-a11c-8ec5f6df8e2e" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an extension to an existing class 1 building; or</txt></block></li><li id="sch.1-sec.5-para1-oc.3" guid="_aaba74a5-7b11-42d6-a045-fd45cfc85d9b" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a structure for an existing class 1 building</txt></block></li></list></block></clause><clause id="sch.1-sec.6" guid="_95bcb837-20de-4ec0-8938-98ef0769eee4" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6</no><heading id="sch.1-sec.6-he" guid="_9b3f8724-245f-4fc1-8cee-be2443b792a5">Water heaters</heading><block><txt break.before="1">work necessary for installing, replacing or removing a water heater, if the work is for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.6-para1" guid="_954f2aae-24ee-4bce-82b6-20f8636b7375" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an existing building; or</txt></block></li><li id="sch.1-sec.6-para1-oc.2" guid="_46db091d-dcc9-4612-956c-deb8069e3323" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an extension to an existing class 1 building; or</txt></block></li><li id="sch.1-sec.6-para1-oc.3" guid="_3a976a7e-5eaa-4bd5-b59b-aabfe3dc4c91" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a structure for an existing class 1 building</txt></block></li></list></block></clause><clause id="sch.1-sec.7" guid="_2e78fbed-ded3-461d-84a2-ba3bdc93c269" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>7</no><heading id="sch.1-sec.7-he" guid="_1f8e6e40-56f5-443f-b8c3-aea9b807db6e">Backflow prevention devices</heading><block><txt break.before="1">work necessary for installing, replacing or removing a testable backflow prevention device or a dual check valve with atmospheric port, if the work is for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.7-para1" guid="_fe353bc0-4d85-4256-9a67-d3e630b28e20" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an existing building; or</txt></block></li><li id="sch.1-sec.7-para1-oc.2" guid="_05181f9a-de00-4e83-9cc6-a175c0c5d24d" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an extension to an existing class 1 building; or</txt></block></li><li id="sch.1-sec.7-para1-oc.3" guid="_42074bfa-a9be-47de-86a9-839e4b47c009" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a structure for an existing class 1 building</txt></block></li></list></block></clause><clause id="sch.1-sec.8" guid="_f10777e2-a413-4b72-acac-b4b81a158451" affected.by.uncommenced="0" spent.amends="0" provision.type="other" toc="no"><no>8</no><heading id="sch.1-sec.8-he" guid="_77b74c21-35c4-4c0c-9247-fddf25cd0d30">Greywater treatment plants</heading><block><txt break.before="1">work necessary for installing or replacing a greywater use facility that includes a greywater treatment plant in a sewered area, if the premises where the facility is proposed to be installed generates no more than 3kL of greywater a day</txt></block></clause><clause id="sch.1-sec.9" guid="_13547012-6c85-43f7-b226-bba89f6bcce2" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>9</no><heading id="sch.1-sec.9-he" guid="_3c94106f-bd71-49ab-8861-20c4cea05299">Fixtures for class 1 or 10 buildings</heading><block><txt break.before="1">work necessary for installing or relocating a fixture, if the work is for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.1-sec.9-para1" guid="_95671124-ca3e-4221-8243-3ac4696da4c7" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an existing class 1 or 10 building or structure; or</txt></block></li><li id="sch.1-sec.9-para1-oc.2" guid="_e613afbb-2b51-42aa-b134-6acb2d8cdcfb" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">an extension to an existing class 1 building; or</txt></block></li><li id="sch.1-sec.9-para1-oc.3" guid="_80371dd8-c972-4543-af15-86cbb42c1001" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a structure for an existing class 1 building</txt></block></li></list></block></clause><clause id="sch.1-sec.10" guid="_635e010a-10e8-4dd2-93a1-616287a5cf57" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>10</no><heading id="sch.1-sec.10-he" guid="_ebf56264-a06e-412a-ab6b-3ae50046b87a">Fixtures for class 2 to 9 buildings of 1 or 2 storeys</heading><block><txt break.before="1">work, other than for sanitary drainage, necessary for installing or relocating a fixture, if the work is for an existing class 2 to 9 building of 1 or 2 storeys above ground</txt></block></clause><clause id="sch.1-sec.11" guid="_f1486459-0ac2-4598-ab3a-c7a0c724ebe1" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>11</no><heading id="sch.1-sec.11-he" guid="_e3b38d1f-2c32-4314-aea2-591e52edf207">Sanitary drains</heading><block><txt break.before="1">work necessary for sealing a sanitary drain upstream from the connection point for a treatment plant or a service provider’s sewerage system, if the work is for an existing building</txt></block></clause><clause id="sch.1-sec.12" guid="_38c468e1-323e-4bce-823c-e671ac6dce0a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>12</no><heading id="sch.1-sec.12-he" guid="_d6ae8d6a-8842-4c1a-b847-c9b890f75cb7">Sealing supply pipes</heading><block><txt break.before="1">work necessary for sealing a supply pipe downstream from a water meter, if the work is for an existing class 2 to 9 building</txt></block></clause></part><historynote><txt break.before="1"><b>sch&#160;1</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.14" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_b079770c-e401-4fe7-97fe-af39fb673a76" valid.date="as.made" check="valid">s 14</legref></txt></historynote></schedule><schedule id="sch.2" guid="_1851c5c7-51bd-4868-9869-ebff429467c4" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 2</no><heading id="sch.2-he" guid="_5fb8ef3e-ecf7-4db8-bdaa-3e55d6da9a6a">Minor work</heading><sourceref id="sch.2-ref" guid="_c1cb8b8c-61e7-4f29-8858-1187f8a945e4" affected.by.uncommenced="0"><intref refid="sec.6" target.guid="_a4b6c655-842c-4f10-b894-79f9597f38f3" check="valid">section&#160;6</intref></sourceref><block><txt break.before="1">work for premises necessary for the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.2-para1" guid="_a080ad84-0a3f-45b0-adfa-e510bc41ce49" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">unblocking sanitary plumbing or sanitary drainage </txt></block></li><li id="sch.2-para1-oc.2" guid="_86930c23-7e8d-4eec-8e22-2f4a8ef6ba51" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">repairing a broken or damaged pipe </txt></block></li><li id="sch.2-para1-oc.3" guid="_5d4a101e-7ae1-4ada-b8eb-a896d6fb7c2f" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">maintaining or repairing an apparatus</txt></block></li><li id="sch.2-para1-oc.4" guid="_bb4bde7e-69eb-41ee-b526-c15bac598152" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">installing, replacing or removing an apparatus, other than—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.2-para1-oc.4-para2" guid="_3a3c43cf-5c87-4910-824a-515a575868e7" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a dual check valve with atmospheric port; or</txt></block></li><li id="sch.2-para1-oc.4-para2-oc.2" guid="_05d2c732-2634-4290-b089-130dc71f47f6" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a temperature control device; or</txt></block></li><li id="sch.2-para1-oc.4-para2-oc.3" guid="_45d63bd7-00e5-402a-a1a8-1e4442709f50" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a testable backflow prevention device; or</txt></block></li><li id="sch.2-para1-oc.4-para2-oc.4" guid="_21b90fb6-ab9b-4c54-b422-e537d9d182fd" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">a water heater</txt></block></li></list></block></li><li id="sch.2-para1-oc.5" guid="_f0f027aa-2c58-4fdb-b2b2-55baae40a2ff" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">maintaining, repairing, replacing or removing a fitting or fixture </txt></block></li><li id="sch.2-para1-oc.6" guid="_53a8c805-8a2b-4649-8df5-f278508500ec" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">maintaining or repairing a greywater use facility or an on-site sewage facility, other than repairing or maintaining an irrigation system for the disposal of effluent from the facility </txt></block></li><li id="sch.2-para1-oc.7" guid="_ed86626b-9064-411a-be64-b0770798c442" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">installing a greywater diversion device </txt></block></li><li id="sch.2-para1-oc.8" guid="_e17efab5-cab7-4f58-b134-e7ab78eacc37" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">maintaining, repairing or replacing a fire hydrant or fire hose reel, unless <intref refid="sch.3" target.guid="_bccfa414-fa42-4597-b13a-126231ca719d" check="valid">schedule&#160;3</intref>, <intref refid="sec.2" target.guid="_ecf2f858-d32b-416f-9f60-e6820e1196e6" check="valid">section&#160;2</intref> applies to the work</txt></block></li><li id="sch.2-para1-oc.9" guid="_b2c3634a-9812-4efa-8c4e-00e89c8fad82" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">sealing a supply pipe downstream from the water meter for a class 1 or 10 building or structure </txt></block></li><li id="sch.2-para1-oc.10" guid="_96b71282-fbd3-41e5-80b8-74edad466aeb" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">installing, removing or replacing an automatic switching device for a rainwater tank </txt></block></li></list></block></schedule><schedule id="sch.3" guid="_bccfa414-fa42-4597-b13a-126231ca719d" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 3</no><heading id="sch.3-he" guid="_79569dde-25b0-46a0-a013-02319b1f5b43">Unregulated work</heading><sourceref id="sch.3-ref" guid="_6b4d15ea-6e62-453a-9e00-4036f71e87b5" affected.by.uncommenced="0"><intref refid="sec.7" target.guid="_da74f108-496a-4163-a069-aa7cf873b1e5" check="valid">section&#160;7</intref></sourceref><clause id="sch.3-sec.1" guid="_1f71fb86-50d5-4220-8709-1102013d59ec" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>1</no><heading id="sch.3-sec.1-he" guid="_c5487f45-4ffd-4d5b-8f8b-689e44ed011e">Unregulated work generally</heading><block><txt break.before="1">work for premises necessary for the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.3-sec.1-para1" guid="_d145ee58-bdbd-423a-8c17-a95a13f1e153" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">replacing a shower head or domestic water filter cartridge</txt></block></li><li id="sch.3-sec.1-para1-oc.2" guid="_404fb799-5a4b-4fd4-a839-38231e80d2e4" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">replacing a jumper valve or washer in a tap</txt></block></li><li id="sch.3-sec.1-para1-oc.3" guid="_7ebd914a-2c37-4394-a4cc-165cedbfae1e" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">repairing or replacing a drop valve washer, float valve washer or suction cup rubber in a toilet cistern</txt></block></li><li id="sch.3-sec.1-para1-oc.4" guid="_ca703535-445e-483d-a040-9d93f457227c" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">replacing caps to ground level inspection openings on a sanitary drain</txt></block></li><li id="sch.3-sec.1-para1-oc.5" guid="_141ecde7-3403-40f7-8d51-a893cb392429" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">cleaning or maintaining a ground level grate for a trap on a sanitary drain</txt></block></li><li id="sch.3-sec.1-para1-oc.6" guid="_5db8d34f-1971-4143-8d09-d48bbca3a556" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">installing or maintaining an irrigation or lawn watering system downstream from a tap, isolating valve or backflow prevention device on the supply pipe for the watering system</txt></block></li><li id="sch.3-sec.1-para1-oc.7" guid="_e1b8fda6-ee94-4887-a9f6-e1590c014617" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">repairing or maintaining an irrigation system for the disposal of effluent from a greywater use facility or on-site sewage facility</txt></block></li></list></block></clause><clause id="sch.3-sec.2" guid="_6561c401-c315-4738-ad9b-3617e2474a91" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>2</no><heading id="sch.3-sec.2-he" guid="_db23d2fe-2ce3-4d97-b88a-d7a124c9563a">Particular work licensed under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="no">Queensland Building and Construction Commission Act 1991</name></legref></heading><subclause id="sch.3-sec.2-ssec" guid="_9be95ae2-bb99-49a9-9452-e24f09bd78f7" affected.by.uncommenced="0" provision.type="other"><block><txt break.before="1">fire protection work for testing plumbing that is carried out by a person who holds a fire protection occupational licence or another licence under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref> that allows the person to carry out the work</txt></block></subclause></clause><clause id="sch.3-sec.3" guid="_15a46e59-22e5-41fe-acb1-f1737f651e6d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>3</no><heading id="sch.3-sec.3-he" guid="_ea357626-e04a-40d9-a13b-8f972582a80f">Incidental unskilled tasks</heading><block><txt break.before="1">tasks of an unskilled nature incidental to other plumbing or drainage work</txt><note id="sch.3-sec.3-note" guid="_752b45d7-b56e-49b6-9a32-d8ec58a61467" type="example"><heading id="sch.3-sec.3-note-he" guid="_be76f418-7440-4153-9ca4-14c623153bb2">Example of a task for <intref refid="sch.3-sec.3" target.guid="_15a46e59-22e5-41fe-acb1-f1737f651e6d" check="valid">section&#160;3</intref>—</heading><block><txt break.before="1">excavating or backfilling a trench</txt></block></note></block></clause></schedule><schedule id="sch.4" guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 4</no><heading id="sch.4-he" guid="_34b3c99c-7737-424b-ac59-3c134fcc7d83">Scope of work for licences and endorsements</heading><sourceref id="sch.4-ref" guid="_97300dbb-ccfa-4a77-bdfd-b92d1de71c69" affected.by.uncommenced="0"><intref refid="sec.13" target.guid="_4423fbcf-414a-4fc8-9231-3e65de44c9c3" check="valid">sections&#160;13</intref> and <intref refid="sec.15" target.guid="_77078d94-034f-4969-be0b-7ef068d6df50" check="valid">15</intref></sourceref><part id="sch.4-pt.1" guid="_ec4a35b8-b3ed-46c2-8291-e88a0874fb15" affected.by.uncommenced="0" toc="no"><no>Part 1</no><heading id="sch.4-pt.1-he" guid="_bffa1703-d3d8-42c4-a59e-52fe9f19a490">Plumbers licence</heading><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.4-pt.1-tbl" guid="_aa52c89a-667f-4345-9a6d-2db9f94c20db" heading.align="left" font.size="10.pt"><tgroup cols="2" colsep="1" rowsep="1" align="left" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.424in"/><colspec colnum="2" colname="2" colwidth="2.396in"/><thead><row rowsep="1" id="sch.4-pt.1-tbl-tblh-tblr" guid="_0e39f69f-e350-47ad-aa78-1356cdc671db"><entry colname="1" id="sch.4-pt.1-tbl-tblh-tblr-tble1" guid="_409fe49d-d549-4bcc-9338-4498f3eacc38"><block><txt break.before="1">Column 1</txt><txt break.before="1">Licence</txt></block></entry><entry colname="2" id="sch.4-pt.1-tbl-tblh-tblr-tble2" guid="_55c05414-d61e-48aa-9acb-5c3a89068ef6"><block><txt break.before="1">Column 2</txt><txt break.before="1">Scope of work</txt></block></entry></row></thead><tbody><row rowsep="0" id="sch.4-pt.1-tbl-tblr" guid="_6708b895-f26e-409d-b882-5cad488e1bc9"><entry colname="1" id="sch.4-pt.1-tbl-tblr-tble1" guid="_b2ffbc63-1548-4aca-958c-3094f105c6dc"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.1-tbl-tblr-tble1-para1.1" guid="_d80fc035-49ae-4b7f-bef8-86ba533de324" affected.by.uncommenced="0"><no>1</no><block><txt break.before="1">plumbers licence</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.1-tbl-tblr-tble2" guid="_ccbdbda0-3603-4254-8635-61de7fa25419"><block><tlist number.type="default"><tli id="sch.4-pt.1-tbl-tblr-tble2-para1.a" guid="_bf228fd3-d0f8-42da-9943-f616090862ec" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">plumbing work, other than plumbing work mentioned in <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, column 2; and</txt></block></tli><tli id="sch.4-pt.1-tbl-tblr-tble2-para1.b" guid="_be532a22-a292-47d6-b661-90e970c87db1" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installation of fire collars that is incidental to plumbing work, other than plumbing work mentioned in <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, column 2</txt></block></tli></tlist></block></entry></row></tbody></tgroup></table><historynote><txt break.before="1"><b>sch&#160;4 pt&#160;1</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;241</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" target.guid="_9d957e39-9743-4222-a7c7-5825b67795e1" valid.date="as.made" check="valid">s 19</legref> <legref jurisd="QLD" type="subordleg" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></block></part><part id="sch.4-pt.2" guid="_15c85d01-551c-43fb-a234-f44cb19a3241" affected.by.uncommenced="0" toc="no"><no>Part 2</no><heading id="sch.4-pt.2-he" guid="_550b26ad-e0d8-4068-85d7-1dbbd572e7a5">Drainers licence</heading><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.4-pt.2-tbl" guid="_4524acb2-21ab-4fea-ab7e-2ecb4db420ee" heading.align="left" font.size="10.pt"><tgroup cols="2" colsep="1" rowsep="1" align="left" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.424in"/><colspec colnum="2" colname="2" colwidth="2.396in"/><thead><row rowsep="1" id="sch.4-pt.2-tbl-tblh-tblr" guid="_85f8cc87-043b-4be3-8e82-913ac87d6c81"><entry colname="1" id="sch.4-pt.2-tbl-tblh-tblr-tble1" guid="_b2132cda-9f0d-431c-857e-20425cc8b7fa"><block><txt break.before="1">Column 1</txt><txt break.before="1">Licence</txt></block></entry><entry colname="2" id="sch.4-pt.2-tbl-tblh-tblr-tble2" guid="_ca48f731-8e49-4a0d-8179-4b8ddb88d153"><block><txt break.before="1">Column 2</txt><txt break.before="1">Scope of work</txt></block></entry></row></thead><tbody><row rowsep="0" id="sch.4-pt.2-tbl-tblr" guid="_197a3d6e-c99e-46aa-8166-7e3769ec19a8"><entry colname="1" id="sch.4-pt.2-tbl-tblr-tble1" guid="_5798d916-b9b0-4b2b-9965-95157945e57a"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.2-tbl-tblr-tble1-para1.1" guid="_5d0caf71-2b26-4240-9992-13f9e571c281" affected.by.uncommenced="0"><no>1</no><block><txt break.before="1">drainers licence</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.2-tbl-tblr-tble2" guid="_c8435603-282d-4373-94c3-46194e8edd71"><block><tlist number.type="default"><tli id="sch.4-pt.2-tbl-tblr-tble2-para1.a" guid="_aa1c8b1f-80e7-46a3-9385-7de6c6936f70" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">drainage work below ground level, other than drainage work mentioned in <intref refid="pt.5" target.guid="_357246d4-1e65-48ec-b9a7-5400c77d68d5" check="valid">part&#160;5</intref>, column 2; and</txt></block></tli><tli id="sch.4-pt.2-tbl-tblr-tble2-para1.b" guid="_9eba4b34-f2e4-49a6-8c35-de265fd30048" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installation of fire collars that is incidental to drainage work below ground level, other than drainage work mentioned in <intref refid="pt.5" target.guid="_357246d4-1e65-48ec-b9a7-5400c77d68d5" check="valid">part&#160;5</intref>, column 2</txt></block></tli></tlist></block></entry></row></tbody></tgroup></table><historynote><txt break.before="1"><b>sch&#160;4 pt&#160;2</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;241</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" target.guid="_9d957e39-9743-4222-a7c7-5825b67795e1" valid.date="as.made" check="valid">s 19</legref> <legref jurisd="QLD" type="subordleg" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></block></part><part id="sch.4-pt.3" guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" affected.by.uncommenced="0" toc="no"><no>Part 3</no><heading id="sch.4-pt.3-he" guid="_0b09f99c-e4d6-4181-80b2-bd1aa74d48df">Restricted licences</heading><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.4-pt.3-tbl" guid="_5193f7ab-cd16-48e4-88cf-a62b000b471f" heading.align="left" font.size="10.pt"><tgroup cols="2" colsep="1" rowsep="1" align="left" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.365in"/><colspec colnum="2" colname="2" colwidth="2.455in"/><thead><row rowsep="1" id="sch.4-pt.3-tbl-tblh-tblr" guid="_218b3170-1bdd-4da6-a448-3a00b11c4b10"><entry colname="1" id="sch.4-pt.3-tbl-tblh-tblr-tble1" guid="_c14fe766-4b21-41b7-8924-4f1e02102817"><block><txt break.before="1">Column 1</txt><txt break.before="1">Type of restricted licence</txt></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblh-tblr-tble2" guid="_1f56235b-e2f3-44cd-9742-dff5f623af75"><block><txt break.before="1">Column 2</txt><txt break.before="1">Scope of work</txt></block></entry></row></thead><tbody><row rowsep="1" id="sch.4-pt.3-tbl-tblr" guid="_349228a6-9d25-4491-ab95-50cd18be8291"><entry colname="1" id="sch.4-pt.3-tbl-tblr-tble1" guid="_1358e3d5-1796-4d6b-893c-f5353c325cee"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-tble1-para1.1" guid="_34f77e1a-a2ae-4bb5-abf6-c0a4a36b9f45" affected.by.uncommenced="0"><no>1</no><block><txt break.before="1">water plumber—gas</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-tble2" guid="_50c671ca-ffe1-4a2e-bd69-963898a28a52"><block align="left"><txt break.before="1">connecting and disconnecting water plumbing associated with replacing a gas hot water heater</txt></block></entry></row><row rowsep="1" id="sch.4-pt.3-tbl-tblr-oc.2" guid="_c81f1aaf-9610-484c-9bc0-416133cdfdbb"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.2-tble1" guid="_5758992f-30ab-4e41-960a-a6bd52e68617"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.2-tble1-para1.2" guid="_f3cef53f-8ccf-44d4-9773-11bf53b67b28" affected.by.uncommenced="0"><no>2</no><block><txt break.before="1">water plumber—	electrical</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.2-tble2" guid="_4b41ae71-0a1b-4026-aa37-375598144be2"><block align="left"><txt break.before="1">connecting and disconnecting water plumbing associated with replacing an electric resistance hot water heater</txt></block></entry></row><row rowsep="1" id="sch.4-pt.3-tbl-tblr-oc.3" guid="_c64a97ca-91b7-4941-b811-0007a8695604"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.3-tble1" guid="_03246561-5452-4432-9fcd-2dc3a28990f4"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.3-tble1-para1.3" guid="_b6b5cf60-42bf-420d-a32c-c80c84bbdca0" affected.by.uncommenced="0"><no>3</no><block><txt break.before="1">water plumber—irrigation</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.3-tble2" guid="_7e8ad517-48b4-4365-bbd9-5f013d3d5243"><block align="left"><txt break.before="1">water plumbing work restricted to irrigation</txt></block></entry></row><row rowsep="1" id="sch.4-pt.3-tbl-tblr-oc.4" guid="_74daf600-5022-41af-9d1c-34ed8c510272"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.4-tble1" guid="_db2916a1-2b44-4e0c-88fb-86d353d53d84"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.4-tble1-para1.4" guid="_941f63f3-5828-43e1-993b-e1cfbe28bcb9" affected.by.uncommenced="0"><no>4</no><block><txt break.before="1">water plumber—fire protection (hydrants and hose reels)</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.4-tble2" guid="_d17656a1-832e-4fba-a816-5270fe779136"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.4-tble2-para1.a" guid="_01366bfb-31b1-40c7-bc0e-5c2408470ce4" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">installing, maintaining and testing fire hydrants and fire hose reels; and</txt></block></tli><tli id="sch.4-pt.3-tbl-tblr-oc.4-tble2-para1.b" guid="_fcf0fc9f-c77b-4c38-a8ae-b43aa4ce4383" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.3-tbl-tblr-oc.4-tble2-para1.a" target.guid="_01366bfb-31b1-40c7-bc0e-5c2408470ce4" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row><row rowsep="1" id="sch.4-pt.3-tbl-tblr-oc.5" guid="_50d9d085-eecd-47e4-afc3-a3eb71e729c2"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.5-tble1" guid="_d7b99553-3764-4ebb-ac98-0252eaba7435"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.5-tble1-para1.5" guid="_1eb050f9-f53c-4b92-a416-3cf92dbf5ffd" affected.by.uncommenced="0"><no>5</no><block><txt break.before="1">water plumber—fire protection (commercial and industrial)</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.5-tble2" guid="_0d05d02a-600b-42d0-9dff-70e85cb35093"><block><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.5-tble2-para1.a" guid="_e21a218e-db80-4057-a0dd-acb4593fe102" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">installing, maintaining and testing commercial and industrial fire sprinkler systems; and</txt></block></tli><tli id="sch.4-pt.3-tbl-tblr-oc.5-tble2-para1.b" guid="_f79a2900-950e-4d5e-907e-0e6b2cb5ccce" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.3-tbl-tblr-oc.5-tble2-para1.a" target.guid="_e21a218e-db80-4057-a0dd-acb4593fe102" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row><row rowsep="1" id="sch.4-pt.3-tbl-tblr-oc.6" guid="_4ed914f1-2531-4cb4-82fe-7d1329bac828"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.6-tble1" guid="_758bfd41-296a-4491-849b-bed76e6600f9"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.6-tble1-para1.6" guid="_dfb3be2c-2e67-4413-8d72-8196fa9e1634" affected.by.uncommenced="0"><no>6</no><block><txt break.before="1">water plumber—fire protection (domestic and residential)</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.6-tble2" guid="_541c31c6-076c-4859-bfd0-0b9846a42710"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.6-tble2-para1.a" guid="_9b355cb3-1cf1-423c-91cb-24bd95c50e8e" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">installing, maintaining and testing domestic and residential fire sprinkler systems; and</txt></block></tli><tli id="sch.4-pt.3-tbl-tblr-oc.6-tble2-para1.b" guid="_f93eff6b-c3a9-4d95-8493-eba4451372ca" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.3-tbl-tblr-oc.6-tble2-para1.a" target.guid="_9b355cb3-1cf1-423c-91cb-24bd95c50e8e" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row><row rowsep="1" id="sch.4-pt.3-tbl-tblr-oc.7" guid="_1c0129d7-2e90-45d9-82a0-cb3cd2dc266f"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.7-tble1" guid="_a1069b01-ded8-480a-a241-b63ad7cf9149"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.7-tble1-para1.7" guid="_fe297b55-0338-4972-ae14-00b3583394bf" affected.by.uncommenced="0"><no>7</no><block><txt break.before="1">water plumber—water and sanitary</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.7-tble2" guid="_26eb20b0-2aca-46ef-8295-b0c277dc7af3"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.7-tble2-para1.a" guid="_5355d805-c865-425a-8ef0-90f7486615fa" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">water plumbing work and sanitary plumbing work; and</txt></block></tli><tli id="sch.4-pt.3-tbl-tblr-oc.7-tble2-para1.b" guid="_6e125ac6-28ed-4845-8200-c293bbd05c3b" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.3-tbl-tblr-oc.7-tble2-para1.a" target.guid="_5355d805-c865-425a-8ef0-90f7486615fa" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row><row rowsep="0" id="sch.4-pt.3-tbl-tblr-oc.8" guid="_b4300efc-8781-49cf-930f-62f8e45c5c58"><entry colname="1" id="sch.4-pt.3-tbl-tblr-oc.8-tble1" guid="_12918c2c-d54e-4cc5-b3f5-2fe104fe7a22"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.8-tble1-para1.8" guid="_0f9afd66-6db7-4e74-ad20-fe0b16ac63ba" affected.by.uncommenced="0"><no>8</no><block><txt break.before="1">drainer—on-site sewage facility</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.3-tbl-tblr-oc.8-tble2" guid="_5c5779b8-581d-40eb-aa89-e2c592154962"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.3-tbl-tblr-oc.8-tble2-para1.a" guid="_cdad5399-9ce9-46fc-8dc1-68721441bea8" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">maintaining on-site sewage facilities; or</txt></block></tli><tli id="sch.4-pt.3-tbl-tblr-oc.8-tble2-para1.b" guid="_4a686d93-6a51-47f1-b1a3-215563d4f71e" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">carrying out OSTP installation work and maintaining on-site sewage facilities</txt></block></tli></tlist></block></entry></row></tbody></tgroup></table><historynote><txt break.before="1"><b>sch&#160;4 pt&#160;3</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;241</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" target.guid="_9d957e39-9743-4222-a7c7-5825b67795e1" valid.date="as.made" check="valid">s 19</legref> <legref jurisd="QLD" type="subordleg" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></block></part><part id="sch.4-pt.4" guid="_92dd9f1e-b114-4b81-bfb9-0cd44e9c6937" affected.by.uncommenced="0" toc="no"><no>Part 4</no><heading id="sch.4-pt.4-he" guid="_7e4f9d79-7c3b-444e-9cf9-03ab15652a68">Endorsements—plumbers or provisional plumbers licences</heading><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.4-pt.4-tbl" guid="_ab227cfa-1a68-48c4-b838-cb110c025ce6" heading.align="left" font.size="10.pt"><tgroup cols="2" colsep="1" rowsep="1" align="left" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.396in"/><colspec colnum="2" colname="2" colwidth="2.417in"/><thead><row rowsep="1" id="sch.4-pt.4-tbl-tblh-tblr" guid="_fb298ec0-0b3d-4874-8794-9109105bc623"><entry colname="1" id="sch.4-pt.4-tbl-tblh-tblr-tble1" guid="_760906d9-8924-442b-837b-21960bcda63b"><block><txt break.before="1">Column 1</txt><txt break.before="1">Endorsement</txt></block></entry><entry colname="2" id="sch.4-pt.4-tbl-tblh-tblr-tble2" guid="_106fc66a-0403-489c-a81b-9b8005a53a16"><block><txt break.before="1">Column 2</txt><txt break.before="1">Scope of work</txt></block></entry></row></thead><tbody><row rowsep="1" id="sch.4-pt.4-tbl-tblr" guid="_98c678df-289f-4d58-80fc-225c3fd43df4"><entry colname="1" id="sch.4-pt.4-tbl-tblr-tble1" guid="_dc6043d8-d46e-4c4c-9106-e0129f96312c"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-tble1-para1.1" guid="_a8158e18-f789-4d0f-87ce-7057ea98ae36" affected.by.uncommenced="0"><no>1</no><block><txt break.before="1">backflow prevention </txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.4-tbl-tblr-tble2" guid="_39da8a78-40b2-4c14-b85c-01b2e03c7d32"><block align="left"><txt break.before="1">testing, commissioning and maintaining backflow prevention devices</txt></block></entry></row><row rowsep="1" id="sch.4-pt.4-tbl-tblr-oc.2" guid="_614537e9-4574-418b-aae6-35882258931e"><entry colname="1" id="sch.4-pt.4-tbl-tblr-oc.2-tble1" guid="_ae3744bc-11e5-4426-858e-99c9a6372d2a"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.2-tble1-para1.2" guid="_699e666e-f332-4d50-9856-6a4feb55598e" affected.by.uncommenced="0"><no>2</no><block><txt break.before="1">thermostatic mixing valve </txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.4-tbl-tblr-oc.2-tble2" guid="_ff76ae3c-c0b2-4d51-af79-dd7a1a24e810"><block align="left"><txt break.before="1">testing, commissioning and maintaining thermostatic mixing valves</txt></block></entry></row><row rowsep="1" id="sch.4-pt.4-tbl-tblr-oc.3" guid="_9f554dff-6ddc-4762-8d80-4e3396a204d3"><entry colname="1" id="sch.4-pt.4-tbl-tblr-oc.3-tble1" guid="_e0063da3-970c-4a65-b610-24aca2ac9290"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.3-tble1-para1.3" guid="_acff7e4b-4f8c-4c65-be1d-d104648b3a76" affected.by.uncommenced="0"><no>3</no><block><txt break.before="1">fire protection—commercial and industrial</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.4-tbl-tblr-oc.3-tble2" guid="_d6799af3-c232-4d7b-b4df-6a8c423471b0"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.3-tble2-para1.a" guid="_de30e759-71ae-4eb2-be93-404905654681" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">installing, maintaining and testing commercial and industrial fire sprinkler systems; and</txt></block></tli><tli id="sch.4-pt.4-tbl-tblr-oc.3-tble2-para1.b" guid="_c053a5b9-4253-4665-81dc-41437b999c33" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.4-tbl-tblr-oc.3-tble2-para1.a" target.guid="_de30e759-71ae-4eb2-be93-404905654681" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row><row rowsep="1" id="sch.4-pt.4-tbl-tblr-oc.4" guid="_c565c525-6f52-46a9-b5f8-e39648a03e2b"><entry colname="1" id="sch.4-pt.4-tbl-tblr-oc.4-tble1" guid="_0e7272f7-c116-45f7-b8d2-c71246fd55ec"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.4-tble1-para1.4" guid="_ad39c2d5-e41b-4c68-aaed-3a9dcfaa9d81" affected.by.uncommenced="0"><no>4</no><block><txt break.before="1">fire protection—domestic and residential</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.4-tbl-tblr-oc.4-tble2" guid="_326e8e0d-f590-4356-b757-22297a9361a5"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.4-tble2-para1.a" guid="_555adcb5-6204-4124-b626-094d2e790784" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">installing, maintaining and testing domestic and residential fire sprinkler systems; and</txt></block></tli><tli id="sch.4-pt.4-tbl-tblr-oc.4-tble2-para1.b" guid="_62b07b60-66d4-4887-bcae-d93c0efdf9fb" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.4-tbl-tblr-oc.4-tble2-para1.a" target.guid="_555adcb5-6204-4124-b626-094d2e790784" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row><row rowsep="0" id="sch.4-pt.4-tbl-tblr-oc.5" guid="_3c99d0c0-ac0d-473a-a567-ced8e927864e"><entry colname="1" id="sch.4-pt.4-tbl-tblr-oc.5-tble1" guid="_6f44776f-969f-4995-8af0-18cbaad1fec7"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.5-tble1-para1.5" guid="_d291c963-8d5e-4e1d-b984-7327ce45025e" affected.by.uncommenced="0"><no>5</no><block><txt break.before="1">solar and heat pump hot water
system installation </txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.4-tbl-tblr-oc.5-tble2" guid="_e0827ef0-a932-4ffc-a08f-4e54afdb4f57"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.4-tbl-tblr-oc.5-tble2-para1.a" guid="_c5e39651-d792-4d91-b8bc-5576a1ace24e" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">installing, maintaining, repairing, replacing and testing solar and heat pump hot water systems; and</txt></block></tli><tli id="sch.4-pt.4-tbl-tblr-oc.5-tble2-para1.b" guid="_a41491b9-83de-475d-bf37-668d7a18c4b0" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">installing fire collars, if the installation is incidental to work mentioned in <intref refid="sch.4-pt.4-tbl-tblr-oc.5-tble2-para1.a" target.guid="_c5e39651-d792-4d91-b8bc-5576a1ace24e" check="valid">paragraph&#160;(a)</intref></txt></block></tli></tlist></block></entry></row></tbody></tgroup></table><historynote><txt break.before="1"><b>sch&#160;4 pt&#160;4</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;241</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2020-0241" target.version.series="58cc4f6d-e7c7-4dd3-916a-adb21b7233ec" target.guid="_9d957e39-9743-4222-a7c7-5825b67795e1" valid.date="as.made" check="valid">s 19</legref> <legref jurisd="QLD" type="subordleg" valid.date="as.made" check="invalid">(3)</legref></txt></historynote></block></part><part id="sch.4-pt.5" guid="_beace490-6959-45b9-ac1c-0f6140330636" affected.by.uncommenced="0" toc="no"><no>Part 5</no><heading id="sch.4-pt.5-he" guid="_d7ce5dff-316d-4ffb-a6ed-0678f4b65274">Endorsements—drainers or provisional drainers licences</heading><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.4-pt.5-tbl" guid="_5b4a4220-c50e-4a73-a292-e51923901bc1" heading.align="left" font.size="10.pt"><tgroup cols="2" colsep="1" rowsep="1" align="left" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.396in"/><colspec colnum="2" colname="2" colwidth="2.417in"/><thead><row rowsep="1" id="sch.4-pt.5-tbl-tblh-tblr" guid="_cc30396f-f9e7-490a-ae24-92e07e58eb40"><entry colname="1" id="sch.4-pt.5-tbl-tblh-tblr-tble1" guid="_be196251-82ea-458b-a992-2274ccc2e38c"><block><txt break.before="1">Column 1</txt><txt break.before="1">Endorsement</txt></block></entry><entry colname="2" id="sch.4-pt.5-tbl-tblh-tblr-tble2" guid="_31df0347-d26e-4ce9-b05f-4569c74527c6"><block><txt break.before="1">Column 2</txt><txt break.before="1">Scope of work</txt></block></entry></row></thead><tbody><row rowsep="0" id="sch.4-pt.5-tbl-tblr" guid="_d3b9bd64-1276-49c7-8fac-08d611eca8e4"><entry colname="1" id="sch.4-pt.5-tbl-tblr-tble1" guid="_f86a15c9-1c9e-437d-81c3-57824e8eac5a"><block align="left"><tlist number.type="default"><tli id="sch.4-pt.5-tbl-tblr-tble1-para1.1" guid="_04b61c5c-d383-4b6e-867a-e0c1cf5c080a" affected.by.uncommenced="0"><no>1</no><block><txt break.before="1">on-site sewage facility maintenance </txt></block></tli></tlist></block></entry><entry colname="2" id="sch.4-pt.5-tbl-tblr-tble2" guid="_73042495-577c-47bc-846a-a91064151f0d"><block align="left"><txt break.before="1">maintaining on-site sewage facilities</txt></block></entry></row></tbody></tgroup></table></block></part></schedule><schedule id="sch.5" guid="_7204e1f3-ae25-4d77-bd0c-99472b11c830" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 5</no><heading id="sch.5-he" guid="_65afe9ea-beb9-4b1a-892a-95e4d27858c8">Documents to accompany treatment plant approval applications</heading><sourceref id="sch.5-ref" guid="_c46f67bc-616c-47a7-9384-e074626ff034" affected.by.uncommenced="0"><intref refid="sec.16" target.guid="_db274771-cdf5-47c5-a844-cef833ef5a69" check="valid">section&#160;16</intref><intref refid="sec.16-ssec.3" target.guid="_5f4522f2-e730-4b50-8285-263c2aca5ba7" check="valid">(3)</intref><intref refid="sec.16-ssec.3-para1.b" target.guid="_4033d7ac-0b27-4395-97eb-36f76e9920c8" check="valid">(b)</intref></sourceref><clause id="sch.5-sec.1" guid="_747bf7d6-2dd2-4ca2-8315-be6e2779782c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>1</no><heading id="sch.5-sec.1-he" guid="_5bce8a0d-3ddb-4fe6-9e01-65b7015bdf12">Documents for application for, or to amend, treatment plant approval</heading><subclause id="sch.5-sec.1-ssec.1" guid="_1a2c1ea8-4bf6-415d-a0b7-a455a946ddfd" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An application for, or to amend, a treatment plant approval for a treatment plant of a particular type must be accompanied by the following documents relating to a treatment plant of that type—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.1-ssec.1-para1.a" guid="_b3458701-2de2-4ca6-8b03-fac58987b591" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a product specifications document complying with <intref refid="sch.5-sec.2" target.guid="_fc17ba36-4b30-4863-8281-0f4e20fe6cd3" check="valid">section&#160;2</intref>;</txt></block></li><li id="sch.5-sec.1-ssec.1-para1.b" guid="_b1a20557-73ae-465e-af3b-6febe97656e6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">engineering drawings of the treatment plant and each component, complying with <intref refid="sch.5-sec.3" target.guid="_1feae8a1-e9a7-4828-926e-fda89bec14ae" check="valid">section&#160;3</intref>;</txt></block></li><li id="sch.5-sec.1-ssec.1-para1.c" guid="_a8a7df05-5ed3-47ba-98c1-269334647aaf" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a product conformity evaluation report;</txt></block></li><li id="sch.5-sec.1-ssec.1-para1.d" guid="_a656204d-83de-46c1-865f-ea373ecd2f9d" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">a product conformity certificate;</txt></block></li><li id="sch.5-sec.1-ssec.1-para1.e" guid="_d75d6256-4124-4100-bf92-18ff88e47e5b" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">each of the following documents prepared by the manufacturer of the treatment plant—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.1-ssec.1-para1.e-para2.i" guid="_a75e0e20-3830-4b5f-9786-dcae2f0cbf8f" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">an installation manual complying with <intref refid="sch.5-sec.4" target.guid="_5f708ab5-8788-4d81-bd6c-837c6b349646" check="valid">section&#160;4</intref>;</txt></block></li><li id="sch.5-sec.1-ssec.1-para1.e-para2.ii" guid="_f04447c8-722e-4338-b2ba-52c7283db043" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">an owner’s operating manual complying with <intref refid="sch.5-sec.5" target.guid="_652d637f-d5fd-4210-9384-0d4342f2eef3" check="valid">section&#160;5</intref>;</txt></block></li><li id="sch.5-sec.1-ssec.1-para1.e-para2.iii" guid="_155a97d8-59c5-4b1a-a098-1f2527d22baf" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">an operation and maintenance manual complying with <intref refid="sch.5-sec.6" target.guid="_d6e7064f-93c4-4e4e-ac8d-91f31465ff37" check="valid">section&#160;6</intref>.</txt></block></li></list></block></li></list></block></subclause><subclause id="sch.5-sec.1-ssec.2" guid="_aa5a9529-ffc2-4211-8279-a357bc193f3d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sch.5-sec.1-ssec.2-def.conformityassessmentbody_" guid="_8f5ff4d9-c8bf-4de0-bb8b-8de0b5aa6097" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.5-sec.1-ssec.2-def.conformityassessmentbody" guid="_a057fdba-3969-4198-abf2-5298121177ae" type="definition">conformity assessment body</defterm> means a conformity assessment body as defined in the conformity assessment requirements.</txt></definition><definition id="sch.5-sec.1-ssec.2-def.productconformitycertificate_" guid="_4e6365e2-a0ef-4ec1-ab44-32506fcfe1c7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.5-sec.1-ssec.2-def.productconformitycertificate" guid="_3a55b2f2-92fa-4c14-887f-3b85410a8308" type="definition">product conformity certificate</defterm>, for a treatment plant of a particular type, means a certificate of that name, issued by a conformity assessment body, certifying that the treatment plant satisfies the requirements of AS 1546.3:2017 or the Queensland Plumbing and Wastewater Code, <intref refid="sch.1" target.guid="_403e71c5-3ea2-4acb-b879-b60f7efbc877" check="valid">schedule&#160;1</intref>.</txt></definition><definition id="sch.5-sec.1-ssec.2-def.productconformityevaluationreport_" guid="_3c930175-3f41-499d-a959-828523b832b8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.5-sec.1-ssec.2-def.productconformityevaluationreport" guid="_fc4f1549-3c0f-4852-873a-5a0d2b1c9f40" type="definition">product conformity evaluation report</defterm>, for a treatment plant of a particular type, means a report of that name, issued by a conformity assessment body, that evaluates the extent to which the treatment plant conforms with AS 1546.3:2017 or the Queensland Plumbing and Wastewater Code, <intref refid="sch.1" target.guid="_403e71c5-3ea2-4acb-b879-b60f7efbc877" check="valid">schedule&#160;1</intref>.</txt></definition></deflist></block><historynote><txt break.before="1"><b>sch&#160;5 s 1</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_d372b70b-9562-4153-9e63-b7309aec647b" valid.date="as.made" check="valid">s 7</legref></txt></historynote></subclause></clause><clause id="sch.5-sec.2" guid="_fc17ba36-4b30-4863-8281-0f4e20fe6cd3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>2</no><heading id="sch.5-sec.2-he" guid="_808f5b70-f5cb-4124-bfa4-ae77c1ca3928">Product specifications document</heading><block><txt break.before="1">The product specifications document for the treatment plant must state—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.2-para1.a" guid="_a8020532-7653-4efe-9b32-0c6347a433cc" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the purpose of the treatment plant; and</txt></block></li><li id="sch.5-sec.2-para1.b" guid="_aa33c763-aed8-4c74-9d62-b3f732d23756" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the name, model and size of the treatment plant; and</txt></block></li><li id="sch.5-sec.2-para1.c" guid="_d8a0dda0-a458-47d1-9ba6-a1876dce6b72" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a description of the flow path for the greywater or sewage being treated in the treatment plant; and</txt></block></li><li id="sch.5-sec.2-para1.d" guid="_84241a38-223b-4df8-8bdd-52af0ddb21be" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">how greywater or sewage is treated in the treatment plant; and</txt></block></li><li id="sch.5-sec.2-para1.e" guid="_50844857-5b92-4f38-a9f8-5d6705ebed2e" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">the name, function, dimensions and, if relevant, the capacity of each component of the treatment plant; and</txt></block></li><li id="sch.5-sec.2-para1.f" guid="_9878317e-c85e-4681-a38e-e9535e5f756c" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">the materials making up each component of the treatment plant.</txt></block></li></list></block></clause><clause id="sch.5-sec.3" guid="_1feae8a1-e9a7-4828-926e-fda89bec14ae" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>3</no><heading id="sch.5-sec.3-he" guid="_c47e61a9-f010-4541-96e1-811dacbb313a">Engineering drawings for treatment plant and components</heading><subclause id="sch.5-sec.3-ssec.1" guid="_b341525c-7604-4caa-b9aa-62811d632b2b" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The engineering drawings of the treatment plant must include plan-view and cross-sectional view engineering drawings of the treatment plant drawn to scale.</txt></block></subclause><subclause id="sch.5-sec.3-ssec.2" guid="_f98aae51-96fe-49d2-a238-a058c92cb9c1" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The engineering drawings of a component of the treatment plant must include—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.3-ssec.2-para1.a" guid="_59732e27-5154-4d95-a92c-7b55a220e132" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">plan-view engineering drawings, drawn to scale, showing the dimensions and capacity of the component; and</txt></block></li><li id="sch.5-sec.3-ssec.2-para1.b" guid="_b367e413-3ef9-43ae-b478-bb9d487b80af" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">cross-sectional view engineering drawings, drawn to scale, showing the dimensions and capacity of the component.</txt></block></li></list></block></subclause></clause><clause id="sch.5-sec.4" guid="_5f708ab5-8788-4d81-bd6c-837c6b349646" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4</no><heading id="sch.5-sec.4-he" guid="_93472cd3-7344-4a01-b652-833b31ae6745">Installation manual</heading><block><txt break.before="1">The installation manual for the treatment plant must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.4-para1.a" guid="_6d75572d-623c-4cd0-8357-ed588c357e7c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">state—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.4-para1.a-para2.i" guid="_9edfff98-853b-493b-ad7a-11c881cfb07c" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the name, model and size of the treatment plant; and</txt></block></li><li id="sch.5-sec.4-para1.a-para2.ii" guid="_5ccb4832-e240-42b0-a0de-99a5b78cae0a" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">how the treatment plant treats greywater or sewage; and</txt></block></li><li id="sch.5-sec.4-para1.a-para2.iii" guid="_f724500e-8d7d-4c0c-88e2-b67e246b43c9" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">clear instructions for unloading the treatment plant from a vehicle and unpacking it in a way that ensures the treatment plant is not damaged; and</txt></block></li><li id="sch.5-sec.4-para1.a-para2.iv" guid="_c9cdf708-2ab1-45f5-9f7f-87a535b40e88" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">clear instructions for installing the treatment plant; and</txt></block></li></list></block></li><li id="sch.5-sec.4-para1.b" guid="_679c09cc-0f7e-4260-bea8-fdfdf3eec79f" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">include—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.4-para1.b-para2.i" guid="_eb2e0e50-2c24-48d3-8e53-d2b0ecdf0c16" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a numbered list of the components of the treatment plant; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.ii" guid="_c7d2b1a9-41f5-483b-886c-cbd5e3acb1df" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">diagrams or photographs identifying each component; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.iii" guid="_62b88bf6-7757-46d7-b2ad-cf4464b3d18a" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">a description of the way each component is expected to function; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.iv" guid="_b462b3c2-99bd-4858-858e-6df0bd9ae218" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">a description of the way the treatment plant is expected to function when the components are properly assembled and connected; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.v" guid="_c7db5c08-1f9f-4c12-b904-5a39069e4730" provision.type="other" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="0">wiring schematics of the electrical components of the treatment plant; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.vi" guid="_42ee4b6c-eb88-42d3-961d-301af4ae8954" provision.type="other" affected.by.uncommenced="0"><no>(vi)</no><block><txt break.before="0">a description of any training a person must undergo and tools a person must use to install the treatment plant; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.vii" guid="_d917515e-7472-41ab-9a7b-1e62c1e43824" provision.type="other" affected.by.uncommenced="0"><no>(vii)</no><block><txt break.before="0">a description of the procedure for commissioning the treatment plant; and</txt></block></li><li id="sch.5-sec.4-para1.b-para2.viii" guid="_09bce798-ef6f-4183-93a6-32a59567283c" provision.type="other" affected.by.uncommenced="0"><no>(viii)</no><block><txt break.before="0">clear instructions for identifying and solving problems that may be causing the treatment plant to malfunction.</txt><note id="sch.5-sec.4-para1.b-para2.viii-note" guid="_f0c7fb23-e8a6-42e1-998e-f96cf4ceb985" type="example"><heading id="sch.5-sec.4-para1.b-para2.viii-note-he" guid="_a2d5e59e-438e-4f14-8081-32d8788ec11d">Example of type of instructions for <intref refid="sch.5-sec.4-para1.b-para2.viii" target.guid="_09bce798-ef6f-4183-93a6-32a59567283c" check="valid">subparagraph&#160;(viii)</intref>—</heading><block><txt break.before="1">a troubleshooting guide</txt></block></note></block></li></list></block></li></list></block></clause><clause id="sch.5-sec.5" guid="_652d637f-d5fd-4210-9384-0d4342f2eef3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>5</no><heading id="sch.5-sec.5-he" guid="_0324b8d3-1320-4d42-95d9-5a9bacb8d6f2">Owner’s operating manual</heading><block><txt break.before="1">The owner’s operating manual for the treatment plant must state the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.5-para1.a" guid="_bc62189c-cd3b-4619-a0d6-8b101a801df8" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the name, model and size of the treatment plant;</txt></block></li><li id="sch.5-sec.5-para1.b" guid="_e9675bb2-f02c-4ac0-b1b6-47130d8e62d6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the limitations of the treatment plant;</txt><note id="sch.5-sec.5-para1.b-note" guid="_37fde774-8afd-4a0e-a9bf-da9153681709" type="example"><heading id="sch.5-sec.5-para1.b-note-he" guid="_0b13c2ec-3b4e-4572-a0cf-8b765f6b7afd">Examples for <intref refid="sch.5-sec.5-para1.b" target.guid="_e9675bb2-f02c-4ac0-b1b6-47130d8e62d6" check="valid">paragraph&#160;(b)</intref>—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.5-para1.b-note-para2" guid="_c63755c1-fe57-4a81-945f-2e5d7174e35c" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">the capacity of the treatment plant</txt></block></li><li id="sch.5-sec.5-para1.b-note-para2-oc.2" guid="_c8d8395f-8391-41e3-8643-71502c5fd5f5" provision.type="other" affected.by.uncommenced="0"><no>•</no><block><txt break.before="0">the level to which greywater or sewage can be treated in the treatment plant</txt></block></li></list></block></note></block></li><li id="sch.5-sec.5-para1.c" guid="_530b210c-f7f4-42d1-ad2e-0f03ea07ed30" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">clear instructions about how the treatment plant must be operated;</txt></block></li><li id="sch.5-sec.5-para1.d" guid="_ffec2696-c433-4bb9-9081-26e73543f5e8" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the type of greywater or sewage that can be treated in the treatment plant;</txt></block></li><li id="sch.5-sec.5-para1.e" guid="_c88210e4-eb4a-40fd-b89c-85c655db44aa" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">how the treatment plant treats greywater or sewage;</txt></block></li><li id="sch.5-sec.5-para1.f" guid="_ae1c97c3-5b91-4057-8a25-ab6eca5927ca" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">the types of substances that, if discharged into the treatment plant, may adversely affect the treatment plant or the environment;</txt></block></li><li id="sch.5-sec.5-para1.g" guid="_9087b89c-00a5-4289-bb5c-6e669f433746" provision.type="other" affected.by.uncommenced="0"><no>(g)</no><block><txt break.before="0">the responsibilities of the owner of the treatment plant for operating and maintaining the treatment plant;</txt></block></li><li id="sch.5-sec.5-para1.h" guid="_401774a2-944e-43e7-8095-8b3886820e63" provision.type="other" affected.by.uncommenced="0"><no>(h)</no><block><txt break.before="0">the actions that must be taken if the treatment plant is to be used intermittently or not used for an extended period;</txt></block></li><li id="sch.5-sec.5-para1.i" guid="_2e050370-6a8a-4fad-9c39-6b1168ca6c97" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">clear instructions for identifying and solving problems that may be causing the treatment plant to malfunction.</txt></block></li></list></block></clause><clause id="sch.5-sec.6" guid="_d6e7064f-93c4-4e4e-ac8d-91f31465ff37" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6</no><heading id="sch.5-sec.6-he" guid="_23914956-d0a6-49f6-83b8-d1a54b3fa09e">Operation and maintenance manual</heading><block><txt break.before="1">The operation and maintenance manual for the treatment plant must state—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-sec.6-para1.a" guid="_9a19967f-a68a-4e3d-9d05-a4075808125f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the name, model and size of the treatment plant; and</txt></block></li><li id="sch.5-sec.6-para1.b" guid="_0f915b31-b289-4e7a-b831-d160d8fc7b53" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">clear instructions about how the treatment plant is to be operated; and</txt></block></li><li id="sch.5-sec.6-para1.c" guid="_59b82909-69d0-4d00-a660-ce2d35ff30d2" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the recommended maintenance schedule for the whole treatment plant and each component of the treatment plant; and</txt></block></li><li id="sch.5-sec.6-para1.d" guid="_8af0b859-bc20-4893-9be3-412741623c00" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the procedures for testing effluent from the treatment plant, including for collecting samples and interpreting the results of testing the samples; and</txt></block></li><li id="sch.5-sec.6-para1.e" guid="_6bb45507-9f05-471d-9d67-c56f4aae469d" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">the type of greywater or sewage that can be treated in the treatment plant; and</txt></block></li><li id="sch.5-sec.6-para1.f" guid="_1252878f-dc52-4182-9f5e-c3556a66a086" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">how the treatment plant treats greywater or sewage; and</txt></block></li><li id="sch.5-sec.6-para1.g" guid="_1651d7cd-c79b-4175-875c-632389db28bf" provision.type="other" affected.by.uncommenced="0"><no>(g)</no><block><txt break.before="0">the types of substances that, if discharged into the treatment plant, may adversely affect the treatment plant or the environment; and</txt></block></li><li id="sch.5-sec.6-para1.h" guid="_05cb5cfa-9b9d-40fa-845b-e7a606d580d9" provision.type="other" affected.by.uncommenced="0"><no>(h)</no><block><txt break.before="0">the recommended procedures for removing sludge from the treatment plant, including by backwashing, at stated intervals; and </txt></block></li><li id="sch.5-sec.6-para1.i" guid="_428e63c9-63f8-4434-a3ed-84931d1384a8" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">clear instructions for identifying and solving problems that may be causing the treatment plant to malfunction.</txt></block></li></list></block></clause></schedule><schedule id="sch.6" guid="_98d1b0de-bce6-4071-a8e5-e9bf5bfcc1c1" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 6</no><heading id="sch.6-he" guid="_6190b846-b203-43ef-b22d-c736d02fe5d0">Documents to accompany permit applications</heading><sourceref id="sch.6-ref" guid="_e9284fff-9fb2-4684-8891-f119b21d9999" affected.by.uncommenced="0"><intref refid="sec.44" target.guid="_4528f36f-7bd6-423d-a224-be2fb51c2190" check="valid">sections&#160;44</intref><intref refid="sec.44-ssec.1" target.guid="_f3147a3a-63cf-4e61-bb19-69882dcb586d" check="valid">(1)</intref><intref refid="sec.44-ssec.1-para1.b" target.guid="_505229fa-66ab-4918-8e66-3f25dd936de3" check="valid">(b)</intref><intref refid="sec.44-ssec.1-para1.b-para2.i" target.guid="_ffd962d5-d52d-4d48-9802-27c37335bed1" check="valid">(i)</intref> and <intref refid="sec.52" target.guid="_f846f1c6-3348-4499-a23f-a3519fae2cde" check="valid">52</intref><intref refid="sec.52-ssec.2" target.guid="_64d62ba7-b0cc-45b8-8218-9df0814955c6" check="valid">(2)</intref><intref refid="sec.52-ssec.2-para1.b" target.guid="_28fda1e1-c9dc-42e7-b9cd-b4372bf18a35" check="valid">(b)</intref></sourceref><historynote><txt break.before="1"><b>sch&#160;6 hdg</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_fd4fe7aa-7dae-4263-af11-672d07abd75b" valid.date="as.made" check="valid">s 15</legref></txt></historynote><part id="sch.6-pt.1" guid="_5765b48f-f2fd-488b-aea4-f42e94ed7724" affected.by.uncommenced="0"><no>Part 1</no><heading id="sch.6-pt.1-he" guid="_42f65c64-336f-4aad-9550-ed0bc15ee897">Preliminary</heading><clause id="sch.6-sec.1" guid="_ee5f5b2a-78fc-4f1c-81b2-f8f4ea0eaeb2" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>1</no><heading id="sch.6-sec.1-he" guid="_de6fd80d-6ca1-41e2-afc9-3157b05ec177">Application of schedule</heading><subclause id="sch.6-sec.1-ssec.1" guid="_e64b690e-ef09-4047-876f-c6d226a99b49" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An application for, or to amend, a permit for plumbing or drainage work must be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.1-ssec.1-para1.a" guid="_207f1790-163e-456b-bc22-06864cd0437c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the documents as required under <intref refid="sch.6-pt.2" target.guid="_e76860dd-7e44-4dc0-9451-39fdd61c728f" check="valid">part&#160;2</intref>; and</txt></block></li><li id="sch.6-sec.1-ssec.1-para1.b" guid="_1ccb6cce-88e3-4455-83b8-4f72627043ea" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the documents mentioned in each section in <intref refid="sch.6-pt.3" target.guid="_9f74259f-db3e-440d-a3e2-3426fc09e0d7" check="valid">part&#160;3</intref> that applies to the application.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.1-ssec.2" guid="_88c6a182-910b-4ba9-aebc-29f527ba39df" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If an application is required under <intref refid="sch.6-pt.2" target.guid="_e76860dd-7e44-4dc0-9451-39fdd61c728f" check="valid">part&#160;2</intref> or <intref refid="sch.6-pt.3" target.guid="_9f74259f-db3e-440d-a3e2-3426fc09e0d7" check="valid">3</intref> to be accompanied by a plan, the plan must comply with the requirements under <intref refid="sch.6-pt.4" target.guid="_b906f9e5-04ef-47bc-a539-b3e5a722ebda" check="valid">part&#160;4</intref>.</txt></block></subclause></clause></part><part id="sch.6-pt.2" guid="_e76860dd-7e44-4dc0-9451-39fdd61c728f" affected.by.uncommenced="0"><no>Part 2</no><heading id="sch.6-pt.2-he" guid="_db56bbd0-2526-4265-9b40-57b73a930c34">Required documents for all applications</heading><clause id="sch.6-sec.2" guid="_a300a49c-b71e-4197-8cd2-133442b1e3ad" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>2</no><heading id="sch.6-sec.2-he" guid="_707aa6ad-667c-4fb3-b073-1a301d59ce25">Documents for work for a class 1a or 10a building</heading><subclause id="sch.6-sec.2-ssec.1" guid="_2755d0e2-b60b-4892-bb49-9c4d5fd8ddbd" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to an application for, or to amend, a permit for work, to the extent the work relates to a class 1a or 10a building.</txt></block></subclause><subclause id="sch.6-sec.2-ssec.2" guid="_41001444-1785-4dd2-822c-187a29054002" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The application must be accompanied by 1 or more plans of the premises where the building is to be situated showing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.2-ssec.2-para1.a" guid="_06a93bb6-e981-4a31-af3c-fb9c7ba76c8b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the location of the proposed building on the premises; and</txt></block></li><li id="sch.6-sec.2-ssec.2-para1.b" guid="_331721d5-62f1-472c-9c65-acd9acd49ba7" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a floor plan of the proposed building showing any proposed sanitary fixtures; and</txt></block></li><li id="sch.6-sec.2-ssec.2-para1.c" guid="_496f0983-fa19-45e8-83d5-63e10c841761" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the elevations of the proposed building.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.2-ssec.3" guid="_53e651ee-3316-41df-aacf-ece3413098e6" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the proposed work involves installing sanitary drainage, the application must also be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.2-ssec.3-para1.a" guid="_dd2363d3-b5dd-44da-a7d8-f663e45237d0" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a site classification report, complying with AS 2870—2011, for the premises; and</txt></block></li><li id="sch.6-sec.2-ssec.3-para1.b" guid="_e4fed314-be22-4606-b4d0-8ee7dc22d92a" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the soil classification for the premises under AS 2870—2011 is H, E or P—a design showing the articulation of the sanitary drainage for the premises.</txt></block></li></list></block></subclause></clause><clause id="sch.6-sec.3" guid="_4a1dba30-665a-4fdb-93a9-9c0c8a07311a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>3</no><heading id="sch.6-sec.3-he" guid="_2103565f-b59d-4359-8bba-11113d4b43bf">Documents for other work</heading><subclause id="sch.6-sec.3-ssec.1" guid="_e25c27a9-f515-477f-bceb-a81b6200f2cf" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to an application for, or to amend, a permit for work for premises, other than to the extent the work relates to a class 1a or 10a building.</txt></block></subclause><subclause id="sch.6-sec.3-ssec.2" guid="_83fc3ec5-428b-47e8-b489-0d54db3f1eeb" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The application must be accompanied by 1 or more plans of the premises showing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.3-ssec.2-para1.a" guid="_17fdc684-6e7d-4871-a876-00359b8e7f73" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the location of any existing or proposed building or structure on the premises; and</txt></block></li><li id="sch.6-sec.3-ssec.2-para1.b" guid="_b15dea25-3940-466e-ab5c-1fddfabe93fb" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for a proposed building—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.3-ssec.2-para1.b-para2.i" guid="_72e04292-9995-46f1-8bc8-e3b9634b28c0" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a floor plan showing any proposed sanitary fixtures; and</txt></block></li><li id="sch.6-sec.3-ssec.2-para1.b-para2.ii" guid="_e038822f-f8ac-4810-a30c-3c7ca4f24612" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the elevations; and</txt></block></li></list></block></li><li id="sch.6-sec.3-ssec.2-para1.c" guid="_25302498-036f-4af6-b3cb-a205ad8642d8" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the location on the premises, and dimensions, of each connection point to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.3-ssec.2-para1.c-para2.i" guid="_240f646a-6eeb-4bb1-8bfd-a26c0ab4e54b" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a service provider’s water supply system; and </txt></block></li><li id="sch.6-sec.3-ssec.2-para1.c-para2.ii" guid="_811405eb-9f00-4be9-90b1-9c122b8c5324" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">any other supply of water; and </txt></block></li><li id="sch.6-sec.3-ssec.2-para1.c-para2.iii" guid="_edd71a28-0fcd-4dcc-80cd-c3edde08a302" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">a sewerage system; and </txt></block></li></list></block></li><li id="sch.6-sec.3-ssec.2-para1.d" guid="_f1f64059-6f3d-40de-8ac5-cfbdd384b392" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the invert levels, and finished surface levels, at each connection point mentioned in <intref refid="sch.6-sec.3-ssec.2-para1.c" target.guid="_25302498-036f-4af6-b3cb-a205ad8642d8" check="valid">paragraph&#160;(c)</intref>; and</txt></block></li><li id="sch.6-sec.3-ssec.2-para1.e" guid="_e5c7eb67-c89b-4e40-a13a-d2f6914fb009" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">the finished surface level for each overflow relief gully; and</txt></block></li><li id="sch.6-sec.3-ssec.2-para1.f" guid="_60cc52f4-c11c-439d-b63d-4f210d92dca0" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">the location on the premises of any of the following that is to result from, or be affected by, the work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.3-ssec.2-para1.f-para2.i" guid="_ab30426b-adc0-4107-a831-35307e28c6b7" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">all water meters and supply pipes; </txt></block></li><li id="sch.6-sec.3-ssec.2-para1.f-para2.ii" guid="_772898be-80e5-43d9-a9af-7f06358df671" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">all fixtures, reflux valves, overflow relief gullies, and sanitary drains; </txt></block></li><li id="sch.6-sec.3-ssec.2-para1.f-para2.iii" guid="_b2bea522-05e3-41ce-9c3f-2730a81a8cf6" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">the access points for cleaning and maintaining plumbing and drainage; </txt></block></li><li id="sch.6-sec.3-ssec.2-para1.f-para2.iv" guid="_6bd337eb-83a1-4720-8451-84bb84a25ed1" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">any testable backflow prevention devices; and</txt></block></li></list></block></li><li id="sch.6-sec.3-ssec.2-para1.g" guid="_ddb316ed-4f78-48b3-988b-b25cdd6af355" provision.type="other" affected.by.uncommenced="0"><no>(g)</no><block><txt break.before="0">for work on a class 1 building on a lot that is part of a community titles scheme, or on a class 2 to 9 building—details of the specifications of each water meter on the lot or for the building. </txt></block></li></list></block></subclause><subclause id="sch.6-sec.3-ssec.3" guid="_08a06795-019b-4668-b762-cb5bd0d252af" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the proposed work involves installing sanitary drainage, the application must also be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.3-ssec.3-para1.a" guid="_938f892a-d18f-4b67-a7c2-f8e0338c8090" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a site classification report, complying with AS 2870—2011, for the premises; and</txt></block></li><li id="sch.6-sec.3-ssec.3-para1.b" guid="_16b97904-139b-49fd-9533-8af55f088273" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the soil classification for the premises under AS 2870—2011 is H, E or P—a design showing the articulation of the sanitary drainage for the premises.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>sch&#160;6 s 3</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.16" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_3237198d-fa6e-4c2d-81fa-a4985acb0052" valid.date="as.made" check="valid">s 16</legref></txt></historynote></clause></part><part id="sch.6-pt.3" guid="_9f74259f-db3e-440d-a3e2-3426fc09e0d7" affected.by.uncommenced="0"><no>Part 3</no><heading id="sch.6-pt.3-he" guid="_b02c8ef1-0abe-4315-8d98-0a79109a3f3d">Additional documents required for particular applications</heading><division id="sch.6-pt.3-div.1" guid="_95861f62-8971-4d7d-aab3-3b31429cd15e" affected.by.uncommenced="0"><no>Division 1</no><heading id="sch.6-pt.3-div.1-he" guid="_2eb53068-6972-437d-b815-44f0e0babaa1">Documents relevant to greywater use facilities</heading><historynote><txt break.before="1"><b>sch&#160;6 pt&#160;3 div&#160;1 hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.17" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_893e51bf-5c97-4798-a6c8-57e26ea7df2a" valid.date="as.made" check="valid">s 17</legref></txt></historynote><clause id="sch.6-sec.4" guid="_d12d4ec2-0dd4-481d-90b2-8c8d33a6aef2" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4</no><heading id="sch.6-sec.4-he" guid="_a031ba24-5236-4965-be3d-089944f8fc83">Documents for work for particular greywater use facilities</heading><subclause id="sch.6-sec.4-ssec.1" guid="_475c8201-03c0-4c58-94f9-0f8a28505e8b" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to an application relating to permit work for a greywater use facility, other than to the extent the facility consists of a greywater (cooling tower) treatment plant.</txt></block></subclause><subclause id="sch.6-sec.4-ssec.2" guid="_ec30667c-05ad-454b-8c57-4c0af760a569" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The application must be accompanied by 1 or more plans showing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.2-para1.a" guid="_5a07e040-92c7-4817-906d-77323c14de84" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the location of any existing or proposed greywater treatment plant; and</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.b" guid="_5a8670f4-00a4-4db4-bcc9-43784c1feec1" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the location of, and connection points for, any existing greywater use facility at the premises, including any connection points to sanitary drainage; and</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.c" guid="_03595e96-854c-4b42-b408-de46d91df5b4" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the proposed location of, and connection points for, any proposed greywater use facility at the premises, including any proposed connection points to sanitary drainage; and</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.d" guid="_d063b5a8-fdf7-4291-990b-f0ffbafc9df5" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the ground levels and drainage invert levels to show whether sanitary drains can gravity feed to the connection point for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.2-para1.d-para2.i" guid="_3688db58-1b98-4887-bc00-2ed605f8ea04" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">a greywater diversion device; or</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.d-para2.ii" guid="_2621b6b2-31ce-451a-a8b7-411251b0b642" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">a greywater treatment plant; or</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.d-para2.iii" guid="_70588e70-3630-49d2-b0d4-5b5281ad69c9" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">a sewerage system; and</txt></block></li></list></block></li><li id="sch.6-sec.4-ssec.2-para1.e" guid="_d2c367c5-ed91-4168-83e4-6518f30740a0" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">if the greywater use facility is to include a land application area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.2-para1.e-para2.i" guid="_eed91d3b-a3e5-4c51-aefa-f90a833a8dba" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the proposed location of the area; and </txt></block></li><li id="sch.6-sec.4-ssec.2-para1.e-para2.ii" guid="_ee017c94-4429-4454-9702-e31ac494c865" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the layout of drainage for the area; and</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.e-para2.iii" guid="_322f506d-02d1-4d4e-8e1e-771911bac58d" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">the distance from the area to each boundary of the premises; and </txt></block></li><li id="sch.6-sec.4-ssec.2-para1.e-para2.iv" guid="_74a0eb4d-1327-4e85-bcdd-4dc0f516c41c" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">the distance from the area to existing or proposed buildings or structures on the premises; and</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.e-para2.v" guid="_c9cdbb4c-7ceb-4552-936d-f20434b9ed5a" provision.type="other" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="0">the distance from the area to any other existing or proposed land application area on the premises; and</txt></block></li><li id="sch.6-sec.4-ssec.2-para1.e-para2.vi" guid="_8410493a-c402-4fe0-ba9f-6c6ee13f2dd1" provision.type="other" affected.by.uncommenced="0"><no>(vi)</no><block><txt break.before="0">the distance from the area to any impervious surfaces on the premises including, for example, paths or paved areas; and </txt></block></li><li id="sch.6-sec.4-ssec.2-para1.e-para2.vii" guid="_8a96e042-b393-48af-81df-8b959db17d78" provision.type="other" affected.by.uncommenced="0"><no>(vii)</no><block><txt break.before="0">the distance from the area to any vulnerable body of water that may be affected by greywater from the facility. </txt></block></li></list></block></li></list></block></subclause><subclause id="sch.6-sec.4-ssec.3" guid="_6adcb413-f63c-42b9-b9ca-8ed5a326b22c" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The application must also be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.3-para1.a" guid="_b19bc904-415d-4f1f-829a-dbca4e958f40" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">details of the proposed use of the greywater; and </txt></block></li><li id="sch.6-sec.4-ssec.3-para1.b" guid="_8bc8ab4e-6679-46c0-a391-2fb9af64e99c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the greywater is to be applied to a land application area—details of how the greywater is to be applied to the land application area; and </txt></block></li><li id="sch.6-sec.4-ssec.3-para1.c" guid="_dfdcb62c-3659-4cf9-9387-744bb3dda5a4" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">if the greywater use facility includes a greywater treatment plant (other than a greywater (cooling tower) treatment plant)—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.3-para1.c-para2.i" guid="_270ba54a-22d7-4786-be57-b7aa53dc122c" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">details of the type and size of the treatment plant; and </txt></block></li><li id="sch.6-sec.4-ssec.3-para1.c-para2.ii" guid="_ca411b23-af62-48b7-81d4-d4dd8b1eac35" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">a copy of the treatment plant approval for the treatment plant; and </txt></block></li></list></block></li><li id="sch.6-sec.4-ssec.3-para1.d" guid="_8415789f-a4a9-47f7-a4a6-7fc0b8b39606" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">a site and soil evaluation report for the premises. </txt></block></li></list></block></subclause><subclause id="sch.6-sec.4-ssec.4" guid="_a574d1ed-28e2-464e-bc72-cebb8592d522" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the greywater use facility is not in a sewered area, the plans accompanying the application must also show—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.4-para1.a" guid="_7c9ea79e-30c6-4973-977d-e433a7e0661d" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the location of any existing or proposed on-site sewage treatment plant; and </txt></block></li><li id="sch.6-sec.4-ssec.4-para1.b" guid="_1e253854-9560-4c8f-a025-12ceb143847c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the work relates to a land application area, the distances from the area to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4-ssec.4-para1.b-para2.i" guid="_3484d9fa-13e7-4368-9aa7-808b9b869bf9" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">any existing or proposed on-site sewage treatment plant; and</txt></block></li><li id="sch.6-sec.4-ssec.4-para1.b-para2.ii" guid="_eb9b874e-1e49-4b34-908f-0cd6f33784e6" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">the land application area for the on-site sewage treatment plant.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>sch&#160;6 s 4</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.18" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_ea264dcd-dac8-4245-a53c-2b6cdf866ef3" valid.date="as.made" check="valid">s 18</legref></txt></historynote></clause><clause id="sch.6-sec.4A" guid="_18ae2ef2-51a1-426f-9aa8-1aa0b6431921" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4A</no><heading id="sch.6-sec.4A-he" guid="_8a707646-f38e-4558-b7d2-006a064935a8">Documents for work for greywater (cooling tower) treatment plant</heading><subclause id="sch.6-sec.4A-ssec.1" guid="_b3c18db4-b57c-44a9-b09b-dedbcb43a4be" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to an application relating to a permit for work for a greywater use facility including a greywater (cooling tower) treatment plant.</txt></block></subclause><subclause id="sch.6-sec.4A-ssec.2" guid="_5c2cad90-22ce-46f4-95a8-99f1965d3396" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The application must be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4A-ssec.2-para1.a" guid="_4669cf21-a0c6-448e-9ef4-afac6748ece2" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">details of the type and size of the treatment plant; and</txt></block></li><li id="sch.6-sec.4A-ssec.2-para1.b" guid="_d65572c1-b8da-4986-b8a5-81720e0c0934" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a report about how greywater will be treated in the treatment plant to the required standard; and</txt></block></li><li id="sch.6-sec.4A-ssec.2-para1.c" guid="_25f9f256-1eb5-4289-b9c7-e24f9d8f9e7e" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a plan for managing the treatment plant that complies with <intref refid="sch.6-sec.4A-ssec.3" target.guid="_83348162-c33f-4371-abc3-116bd0a67204" check="valid">subsection&#160;(3)</intref>.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.4A-ssec.3" guid="_83348162-c33f-4371-abc3-116bd0a67204" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The plan for managing the greywater (cooling tower) treatment plant must— </txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4A-ssec.3-para1.a" guid="_9801c9ae-0c6c-43ac-ba1f-463bbb75e14c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">describe the systems for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4A-ssec.3-para1.a-para2.i" guid="_97504a5f-7278-4653-aae1-27bf046b79f7" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">collecting and processing the greywater at the treatment plant; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.a-para2.ii" guid="_6e69d8f6-987d-42c4-acd6-c0bc7c2696e4" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">supplying greywater to the cooling tower at the treatment plant; and</txt></block></li></list></block></li><li id="sch.6-sec.4A-ssec.3-para1.b" guid="_a6d6aabe-b704-4a8a-8a88-84b0e821fd97" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">identify each hazard and hazardous event associated with each system mentioned in <intref refid="sch.6-sec.4A-ssec.3-para1.a" target.guid="_9801c9ae-0c6c-43ac-ba1f-463bbb75e14c" check="valid">paragraph&#160;(a)</intref>; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.c" guid="_21d6aafa-df1f-4ef7-9864-e7f7c007ae63" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">include an assessment of the risks associated with each hazard and hazardous event mentioned in <intref refid="sch.6-sec.4A-ssec.3-para1.b" target.guid="_a6d6aabe-b704-4a8a-8a88-84b0e821fd97" check="valid">paragraph&#160;(b)</intref>; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.d" guid="_90d834a8-0d9a-4993-a48c-f4dcab88b380" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">state each action that will be taken in response to each risk mentioned in <intref refid="sch.6-sec.4A-ssec.3-para1.c" target.guid="_21d6aafa-df1f-4ef7-9864-e7f7c007ae63" check="valid">paragraph&#160;(c)</intref>; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.e" guid="_83fe5d5a-e806-45ae-92ec-e41e8c1baab5" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">state how the treatment plant will be monitored to ensure greywater is treated to the required standard; and </txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.f" guid="_149d9943-fe80-400a-b627-25ade54029ea" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">state how each action mentioned in <intref refid="sch.6-sec.4A-ssec.3-para1.d" target.guid="_90d834a8-0d9a-4993-a48c-f4dcab88b380" check="valid">paragraph&#160;(d)</intref> will be monitored to check its effectiveness; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.g" guid="_7d626546-3bad-4e94-bcc2-6ec04f31e64f" provision.type="other" affected.by.uncommenced="0"><no>(g)</no><block><txt break.before="0">state how records of the matters mentioned in paragraphs (a) to (f) will be kept; and </txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.h" guid="_34e3eb8f-f581-4e8c-8c06-7c15846c529d" provision.type="other" affected.by.uncommenced="0"><no>(h)</no><block><txt break.before="0">state how often the plan will be reviewed; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.i" guid="_2116ece4-c074-45be-8d06-4608eae1ba64" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">state the name and contact details of each person who will be responsible for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.4A-ssec.3-para1.i-para2.i" guid="_dcf097e1-295e-4ff3-8d42-65bc3ff70437" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">taking each action mentioned in <intref refid="sch.6-sec.4A-ssec.3-para1.d" target.guid="_90d834a8-0d9a-4993-a48c-f4dcab88b380" check="valid">paragraph&#160;(d)</intref>; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.i-para2.ii" guid="_fb8ee4e2-feff-4171-a399-fcbf8d7c9dd2" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">monitoring the treatment plant as mentioned in <intref refid="sch.6-sec.4A-ssec.3-para1.e" target.guid="_83fe5d5a-e806-45ae-92ec-e41e8c1baab5" check="valid">paragraph&#160;(e)</intref>; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.i-para2.iii" guid="_41a62c8a-7999-41fb-87fc-11e8ddef8631" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">monitoring each action to which <intref refid="sch.6-sec.4A-ssec.3-para1.f" target.guid="_149d9943-fe80-400a-b627-25ade54029ea" check="valid">paragraph&#160;(f)</intref> relates; and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.i-para2.iv" guid="_0f4626c3-5308-46fc-92fc-2c6bd393a6b3" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">keeping records of the matters mentioned in paragraphs (a) to (f); and</txt></block></li><li id="sch.6-sec.4A-ssec.3-para1.i-para2.v" guid="_62a8c6a4-6b41-4965-ac07-25471c19c81b" provision.type="other" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="0">reviewing the plan; and</txt></block></li></list></block></li><li id="sch.6-sec.4A-ssec.3-para1.j" guid="_0ac54705-85f4-4cd6-86a0-8acf99eb397a" provision.type="other" affected.by.uncommenced="0"><no>(j)</no><block><txt break.before="0">provide for any other matters relevant to the management of the treatment plant.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s 4A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c5faa1dd-bbe4-4741-b655-791164d9c422" valid.date="as.made" check="valid">s 19</legref></txt></historynote></clause></division><division id="sch.6-pt.3-div.2" guid="_890c7d1c-5118-453e-a9bc-c43adb5922e0" affected.by.uncommenced="0"><no>Division 2</no><heading id="sch.6-pt.3-div.2-he" guid="_a1303f31-a4c8-4cf4-9857-0f4c177b2d11">Other documents</heading><historynote><txt break.before="1"><b>sch&#160;6 pt&#160;3 div&#160;2 hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c5faa1dd-bbe4-4741-b655-791164d9c422" valid.date="as.made" check="valid">s 19</legref></txt></historynote><clause id="sch.6-sec.5" guid="_c6c608c4-9c91-4a37-bbb1-1326b9d02ca3" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>5</no><heading id="sch.6-sec.5-he" guid="_af817867-d311-4b5f-a434-03baa5127464">Documents for work for an on-site sewage facility</heading><subclause id="sch.6-sec.5-ssec.1" guid="_8f6ff3bf-3f3f-4f02-bbae-5de2a6cb2ea3" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An application relating to a permit for work for an on-site sewage facility must be accompanied by 1 or more plans showing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.5-ssec.1-para1.a" guid="_6b9c0c7c-8135-4dfc-80cf-64775a6a7a9c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the location of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.5-ssec.1-para1.a-para2.i" guid="_74972762-9657-4384-8599-82322a5b2d64" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">any existing or proposed on-site sewage treatment plant; and</txt></block></li><li id="sch.6-sec.5-ssec.1-para1.a-para2.ii" guid="_c8b83ebf-92f6-4516-a560-7b6f0bc01d19" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">any vulnerable body of water that may be affected by effluent from the facility; and </txt></block></li></list></block></li><li id="sch.6-sec.5-ssec.1-para1.b" guid="_3acbc35e-9efe-47e1-9051-b9ce0a58f23b" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the location of, and connection points for, any existing on-site sewage facility at the premises; and</txt></block></li><li id="sch.6-sec.5-ssec.1-para1.c" guid="_f43f0640-6f39-44c4-963e-9d15cfc17af5" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the proposed location of, and connection points for, any proposed on-site sewage facility at the premises; and</txt></block></li><li id="sch.6-sec.5-ssec.1-para1.d" guid="_741de48d-e10e-4c1b-8259-8c1847dad924" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the ground levels and drainage invert levels to show whether sanitary drains can gravity feed to the connection point for the on-site sewage treatment plant forming part of the facility.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.5-ssec.2" guid="_c8a3b52f-880f-4df4-be0f-17f073845e9b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the work relates to a land application area, the plans must also show—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.5-ssec.2-para1.a" guid="_f6631a3b-7aaa-4903-ac2d-af3fc3c1a1cb" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the proposed location of the area; and</txt></block></li><li id="sch.6-sec.5-ssec.2-para1.b" guid="_79851209-86be-42a8-8b98-ed33ffb3b003" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the layout of drainage for the area; and</txt></block></li><li id="sch.6-sec.5-ssec.2-para1.c" guid="_bb3659e8-9078-4c21-a49d-57425e32bfb7" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">how the effluent is to be applied to the area; and </txt></block></li><li id="sch.6-sec.5-ssec.2-para1.d" guid="_9f5697e4-8585-4048-93af-9cf2a811b155" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">the distances from the area to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.5-ssec.2-para1.d-para2.i" guid="_7bd6cca1-5987-4171-8c9d-8c51922aa869" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">the boundaries of the premises; and </txt></block></li><li id="sch.6-sec.5-ssec.2-para1.d-para2.ii" guid="_bf0d45e2-208c-4155-bce3-fc2c3f1cf726" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">any existing or proposed buildings or structures on the premises; and </txt></block></li><li id="sch.6-sec.5-ssec.2-para1.d-para2.iii" guid="_13edfb88-8700-4a76-8d00-11002f29bf41" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">any impervious surfaces on the premises including, for example, paths or paved areas. </txt></block></li></list></block></li></list></block></subclause><subclause id="sch.6-sec.5-ssec.3" guid="_7a78ccbc-b257-40ae-ad69-585c5651ff3c" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The application must also be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.5-ssec.3-para1.a" guid="_3c392dcf-7e13-4719-b9ec-f42583f84ab6" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">details about the type and size of the on-site sewage treatment plant; and </txt></block></li><li id="sch.6-sec.5-ssec.3-para1.b" guid="_22ab48e8-b04c-4b4f-a22b-dd4fe2ac45fe" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the on-site sewage facility includes a secondary on-site sewage treatment plant—a copy of the treatment plant approval for the treatment plant; and</txt></block></li><li id="sch.6-sec.5-ssec.3-para1.c" guid="_76b04477-4aca-47c9-b0d8-522a893a31e6" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a site and soil evaluation report for the premises. </txt></block></li></list></block></subclause></clause><clause id="sch.6-sec.6" guid="_761a4998-f802-43d7-a563-11a1ec1bcb69" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6</no><heading id="sch.6-sec.6-he" guid="_103a4489-84bd-4f28-b380-1e9894a86a17">Documents supporting a performance solution</heading><subclause id="sch.6-sec.6-ssec.1" guid="_0a6cf1b7-4eee-4e54-b94a-768c1c6afb7e" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to an application if, for the application, a performance solution is proposed to be used to comply with a performance requirement of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.6-ssec.1-para1.a" guid="_d71ac38d-e74e-4720-93be-a9e1557769e1" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the Queensland Plumbing and Wastewater Code; or</txt></block></li><li id="sch.6-sec.6-ssec.1-para1.b" guid="_75dc6182-2583-42d8-9bd6-62c21b7afe7d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the Plumbing Code of Australia.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.6-ssec.2" guid="_c1c58077-791b-4109-aec2-a2153d367f3d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The application must be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.6-ssec.2-para1.a" guid="_02f528f7-7769-487d-86c4-d399ee399e6a" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a document stating—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.6-ssec.2-para1.a-para2.i" guid="_f797e5d7-fad4-425c-8c6e-022a14ab23f2" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">each performance requirement the performance solution is intended to satisfy; and</txt></block></li><li id="sch.6-sec.6-ssec.2-para1.a-para2.ii" guid="_684d94c9-7208-4087-9403-2709a726fbab" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">details of the performance solution, including, for example, how the performance solution differs from the deemed-to-satisfy solution for the performance requirement; and</txt></block></li><li id="sch.6-sec.6-ssec.2-para1.a-para2.iii" guid="_3a0c05c6-46ff-45a9-bd47-f6892f7dc950" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">how the performance solution will satisfy the performance requirement; and</txt></block></li><li id="sch.6-sec.6-ssec.2-para1.a-para2.iv" guid="_ba7f432f-800b-4188-93fb-9ad66eda31b1" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">details of the test results and other information relied on to develop the performance solution; and</txt></block></li></list></block></li><li id="sch.6-sec.6-ssec.2-para1.b" guid="_bbd15742-53e1-4c3f-b49d-eb909fb333c0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">any document certifying technical details or drawings for the performance solution provided by a competent person for developing the performance solution.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.6-ssec.3" guid="_bfae35aa-87c1-47a8-a58d-26575bb1b81a" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sch.6-sec.6-ssec.3-def.competentperson_" guid="_0b7d5da4-607b-416a-8073-bf7ddd83cc7e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-sec.6-ssec.3-def.competentperson" guid="_3b2d2e96-2115-4b99-9593-90ecb24c4a37" type="definition">competent person</defterm>, for developing a performance solution, means any of the following persons—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.6-ssec.3-def.competentperson-para1.a" guid="_18001393-2c4f-4d23-87fa-07a1ac326dd2" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person who holds a licence under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref> under which the person is qualified to develop the solution;</txt></block></li><li id="sch.6-sec.6-ssec.3-def.competentperson-para1.b" guid="_120ae7b5-ad45-4602-a9df-26fa81257bfb" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a registered professional engineer for an area of engineering relevant to developing the solution; </txt></block></li><li id="sch.6-sec.6-ssec.3-def.competentperson-para1.c" guid="_2d3ec128-f17b-499f-91fd-703be6bcd26f" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">another person the local government deciding the application considers is competent to develop the solution.</txt></block></li></list></definition></deflist></block></subclause></clause><clause id="sch.6-sec.7" guid="_1da6da64-c8a3-4deb-9fd2-92a438513810" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>7</no><heading id="sch.6-sec.7-he" guid="_38111be2-f5cd-4472-a61d-bee401c5ec81">Documents supporting an alternative solution</heading><subclause id="sch.6-sec.7-ssec.1" guid="_0c3d72e4-c184-4cfa-9942-2052c1e04f99" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to an application if, for the application, an alternative solution under the Queensland Development Code is proposed to be used to comply with a performance criteria of the code. <b/></txt></block></subclause><subclause id="sch.6-sec.7-ssec.2" guid="_6cb0b19e-5328-4941-b30d-39f72b68baaa" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The application must be accompanied by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.7-ssec.2-para1.a" guid="_02ad0117-1806-4691-a989-cc9bee58ab5a" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a document that states—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.7-ssec.2-para1.a-para2.i" guid="_34469147-aeb5-481c-a619-ffd1766449ba" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">each performance criteria the alternative solution is intended to satisfy; and</txt></block></li><li id="sch.6-sec.7-ssec.2-para1.a-para2.ii" guid="_3756c975-5261-477b-aaf8-a145b13e6c4a" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">details of the alternative solution, including, for example, how the alternative solution differs from the performance criteria; and</txt></block></li><li id="sch.6-sec.7-ssec.2-para1.a-para2.iii" guid="_fae82333-0cdb-4e8e-b82f-6a82478ad481" provision.type="other" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="0">how the alternative solution will satisfy the performance criteria; and</txt></block></li><li id="sch.6-sec.7-ssec.2-para1.a-para2.iv" guid="_b07d6a0a-b5d1-4e2a-8308-6b8795cf210e" provision.type="other" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="0">details of the test results and other information relied on to develop the alternative solution; and</txt></block></li></list></block></li><li id="sch.6-sec.7-ssec.2-para1.b" guid="_62e15c1d-9f20-456d-8ce7-3ace68fc0d06" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">any document certifying technical details or drawings for the alternative solution provided by a competent person for developing the alternative solution.</txt></block></li></list></block></subclause><subclause id="sch.6-sec.7-ssec.3" guid="_d96befcc-1652-4c29-b835-304d7e00333e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sch.6-sec.7-ssec.3-def.competentperson_" guid="_8fea856d-b8f2-4cc3-b4cf-5c049d63cc8a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-sec.7-ssec.3-def.competentperson" guid="_404bdee3-fcb1-4511-8a6f-4da9ae88f618" type="definition">competent person</defterm>, for developing an alternative solution, means any of the following persons—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.7-ssec.3-def.competentperson-para1.a" guid="_6f88e3d2-5300-4aa5-887e-9997e8e6f0a1" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person who holds a licence under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref> under which the person is qualified to develop the solution;</txt></block></li><li id="sch.6-sec.7-ssec.3-def.competentperson-para1.b" guid="_02404028-a546-456b-9dde-e199579e0e18" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a registered professional engineer for an area of engineering relevant to developing the solution; </txt></block></li><li id="sch.6-sec.7-ssec.3-def.competentperson-para1.c" guid="_33c5974b-47b3-46cd-b2e8-b923899e6640" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">another person the local government deciding the application considers is competent to develop the solution.</txt></block></li></list></definition></deflist></block></subclause></clause></division></part><part id="sch.6-pt.4" guid="_b906f9e5-04ef-47bc-a539-b3e5a722ebda" affected.by.uncommenced="0"><no>Part 4</no><heading id="sch.6-pt.4-he" guid="_26ba7f37-5928-42ba-899f-7e96d7d8319b">Requirements for plans</heading><clause id="sch.6-sec.8" guid="_8e6e1335-a060-48e9-a977-8da5f2cf589b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>8</no><heading id="sch.6-sec.8-he" guid="_1ce88326-9516-4db1-a334-52413aba0515">General requirements for plans accompanying applications</heading><subclause id="sch.6-sec.8-ssec.1" guid="_97d170a3-f6ad-4fcd-8e7d-8d4d6ba75a1c" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if under <intref refid="sch.6-pt.2" target.guid="_e76860dd-7e44-4dc0-9451-39fdd61c728f" check="valid">part&#160;2</intref> or <intref refid="sch.6-pt.3" target.guid="_9f74259f-db3e-440d-a3e2-3426fc09e0d7" check="valid">3</intref> an application is required to be accompanied by a plan.</txt></block></subclause><subclause id="sch.6-sec.8-ssec.2" guid="_b21f8822-66aa-4b91-a308-568a5ebc85f1" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.8-ssec.2-para1.a" guid="_e17799b5-2a18-4f21-8a20-ec1e4680158f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">be drawn to scale; and</txt></block></li><li id="sch.6-sec.8-ssec.2-para1.b" guid="_3861bdec-dd67-4865-be13-ebe48c10f8e9" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for an application other than a fast-track application or fast-track amendment application—show enough detail to allow the local government deciding the application to assess the work to which the plan relates; and</txt></block></li><li id="sch.6-sec.8-ssec.2-para1.c" guid="_f2395b72-193f-4d1d-b0fa-a6eb07d0286c" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">show the relevant details of the person who designed the plumbing or drainage work on—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.8-ssec.2-para1.c-para2.i" guid="_6b2df9c7-4043-4dec-8beb-07628d56d250" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">each page of the plan; or </txt></block></li><li id="sch.6-sec.8-ssec.2-para1.c-para2.ii" guid="_89ca5906-1218-403c-880c-c12ed244528f" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">a page at the front of the plan that refers to each other page of the plan. </txt></block></li></list></block></li></list></block></subclause><subclause id="sch.6-sec.8-ssec.3" guid="_2186fb09-a4ca-4495-9217-aef007df5b27" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sch.6-sec.8-ssec.3-def.relevantdetails_" guid="_95f3a991-df22-4824-8560-a6aea82beed4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-sec.8-ssec.3-def.relevantdetails" guid="_902aa4ff-2248-48c0-b679-5ee89f25b96a" type="definition">relevant details</defterm>, of the person who designed the plumbing or drainage work, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-sec.8-ssec.3-def.relevantdetails-para1.a" guid="_0814ab4e-bda0-4c1c-abc7-f0d8b5a5c2c7" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the person’s name; and</txt></block></li><li id="sch.6-sec.8-ssec.3-def.relevantdetails-para1.b" guid="_d3c78102-e5d8-429d-b298-54cc8d5e15c9" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the person is licensed or registered under a law of the State to practise in the aspect relevant to the work—the person’s licence number or registration number; and</txt></block></li><li id="sch.6-sec.8-ssec.3-def.relevantdetails-para1.c" guid="_f0a1ce30-b7e1-4a29-a674-bad18c60cb5a" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">if the work relates to a greywater use facility or an on-site sewage facility and <intref refid="sch.6-sec.8-ssec.3-def.relevantdetails-para1.b" target.guid="_d3c78102-e5d8-429d-b298-54cc8d5e15c9" check="valid">paragraph&#160;(b)</intref> does not apply—enough information about the person’s qualifications and experience to allow the local government to decide whether the person is qualified to design the facility.</txt></block></li></list></definition></deflist></block></subclause></clause></part></schedule><schedule id="sch.7" guid="_f928d1e9-286a-45c8-81b8-6c9819bd258e" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 7</no><heading id="sch.7-he" guid="_e685cf8c-34f1-4daf-b397-32241e187e1b">Local governments that may declare remote areas</heading><sourceref id="sch.7-ref" guid="_3e1a8db4-c2d2-4a07-ab4a-7defe65bc17a" affected.by.uncommenced="0"><intref refid="sec.70" target.guid="_5a47d2ef-cc7e-48ca-a311-94b89cc5fc10" check="valid">section&#160;70</intref><intref refid="sec.70-para1.a" check="invalid">(a)</intref></sourceref><block><list number.type="manual" unnumbered.indent="0"><li id="sch.7-para1" guid="_6dfb818d-456b-4930-b66f-f9074f9aeb4a" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Aurukun Shire Council</txt></block></li><li id="sch.7-para1-oc.2" guid="_b2880809-2460-423f-8265-d697eeb57668" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Balonne Shire Council</txt></block></li><li id="sch.7-para1-oc.3" guid="_46fb4bed-8b94-4249-a5c5-20122b2bc329" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Banana Shire Council</txt></block></li><li id="sch.7-para1-oc.4" guid="_601837c4-edee-4555-b1f7-26821a8cbfd7" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Barcaldine Regional Council</txt></block></li><li id="sch.7-para1-oc.5" guid="_6d9b5b41-95b5-4d44-9f48-9ec40b2ae7c9" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Barcoo Shire Council</txt></block></li><li id="sch.7-para1-oc.6" guid="_7b59ca45-e7a1-4930-9fad-50da984e6775" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Blackall-Tambo Regional Council</txt></block></li><li id="sch.7-para1-oc.7" guid="_6da338f7-253c-493a-aba1-4607459fd5be" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Boulia Shire Council</txt></block></li><li id="sch.7-para1-oc.8" guid="_be03a01c-1cf9-431a-9f0a-00d50522ca2c" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Bulloo Shire Council</txt></block></li><li id="sch.7-para1-oc.9" guid="_0a8c9241-0bdb-4454-9c9b-eb0e2cf77881" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Burke Shire Council</txt></block></li><li id="sch.7-para1-oc.10" guid="_640108c3-b335-461a-84e6-6970cc0ded86" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Carpentaria Shire Council</txt></block></li><li id="sch.7-para1-oc.11" guid="_9dbdfad9-0c28-4434-99ab-eeec8693e31b" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Cassowary Coast Regional Council</txt></block></li><li id="sch.7-para1-oc.12" guid="_0bb6e84a-29ab-4064-af71-2a6230ad0ca8" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Central Highlands Regional Council</txt></block></li><li id="sch.7-para1-oc.13" guid="_f9677812-f9e6-4b48-85fd-f468518e50c0" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Charters Towers Regional Council</txt></block></li><li id="sch.7-para1-oc.14" guid="_53cdfc00-4e95-4f42-951c-6b65e98fc9e9" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Cloncurry Shire Council</txt></block></li><li id="sch.7-para1-oc.15" guid="_8ce1a99e-e190-48f2-93c8-cafc7f64cfc0" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Cook Shire Council</txt></block></li><li id="sch.7-para1-oc.16" guid="_d1976975-a5c8-43f2-9136-4ed5d1a9dccf" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Croydon Shire Council</txt></block></li><li id="sch.7-para1-oc.17" guid="_e2eaceb8-21c1-4ddf-9e77-21f589b90d4b" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Diamantina Shire Council</txt></block></li><li id="sch.7-para1-oc.18" guid="_1366d601-0584-4504-b82f-737933bc16c7" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Doomadgee Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.19" guid="_ce3e7ae9-ba10-45ce-b0fb-26427fe552d5" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Etheridge Shire Council</txt></block></li><li id="sch.7-para1-oc.20" guid="_3eef0d70-8e4c-4bb6-8e2b-c231aee4800d" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Flinders Shire Council</txt></block></li><li id="sch.7-para1-oc.21" guid="_6c6e9cb7-3757-4262-9e8c-210bbad6712b" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Hinchinbrook Shire Council</txt></block></li><li id="sch.7-para1-oc.22" guid="_429bd97d-cce9-4241-9de9-5557f8f5faa5" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Hope Vale Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.23" guid="_c234478d-24cf-4f3b-a001-f6c7f3b7db83" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Isaac Regional Council</txt></block></li><li id="sch.7-para1-oc.24" guid="_79934feb-17ed-4b2c-a6e7-69ea6a1023c8" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Kowanyama Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.25" guid="_3c90093b-4bbd-4df7-904d-445c7f2e756c" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Lockhart River Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.26" guid="_5f9cd9b2-ab4b-473c-95c6-6077a632f08d" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Longreach Regional Council</txt></block></li><li id="sch.7-para1-oc.27" guid="_3e5fb686-352e-43a3-8b26-5e20604af23e" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Mapoon Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.28" guid="_85181797-295e-488c-80d0-880bd46f8081" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Maranoa Regional Council</txt></block></li><li id="sch.7-para1-oc.29" guid="_380e27b5-7ebf-488e-8b3e-7ed4836b4303" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Mareeba Shire Council</txt></block></li><li id="sch.7-para1-oc.30" guid="_7be17093-53e8-4f8d-82e6-ceacb0527339" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">McKinlay Shire Council</txt></block></li><li id="sch.7-para1-oc.31" guid="_7a652eb1-86e0-43cd-8777-2dab6e598334" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Mornington Shire Council</txt></block></li><li id="sch.7-para1-oc.32" guid="_c9cd6aa1-1801-46f5-af15-36898898a093" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Mount Isa City Council</txt></block></li><li id="sch.7-para1-oc.33" guid="_9e0330ee-5e5b-4687-beba-cb15bd2e657f" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Murweh Shire Council</txt></block></li><li id="sch.7-para1-oc.34" guid="_285ee3cd-ce8d-4ff7-b7a8-3fea2b576b06" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Napranum Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.35" guid="_ca53bab3-fa82-44b1-985f-683e02564778" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Northern Peninsula Area Regional Council</txt></block></li><li id="sch.7-para1-oc.36" guid="_d93251e8-ba70-4856-ab0c-5dea707bdf92" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Palm Island Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.37" guid="_ac26b7bd-8b6d-4561-845c-da5129ecf6da" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Paroo Shire Council</txt></block></li><li id="sch.7-para1-oc.38" guid="_d82616f1-412f-41dc-b52a-5286c43e5bec" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Pormpuraaw Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.39" guid="_9dac763c-6435-4362-8bc3-e747c9bebfb4" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Quilpie Shire Council</txt></block></li><li id="sch.7-para1-oc.40" guid="_5c90166b-06e2-476a-b8e5-4b8aab8ba0cc" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Richmond Shire Council</txt></block></li><li id="sch.7-para1-oc.41" guid="_6d68843d-283e-4222-95e2-e807a25c5d52" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Tablelands Regional Council</txt></block></li><li id="sch.7-para1-oc.42" guid="_0dc8cd7f-6980-44e5-9ed4-7b878c6b8237" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Torres Shire Council</txt></block></li><li id="sch.7-para1-oc.43" guid="_4076f66b-593e-494f-a8f4-9562d8324c0c" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Torres Strait Island Regional Council</txt></block></li><li id="sch.7-para1-oc.44" guid="_f40f239c-53d7-4e48-9126-c774e36ca609" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Whitsunday Regional Council</txt></block></li><li id="sch.7-para1-oc.45" guid="_905ed7aa-2d43-4abc-8f91-a88f68354c5e" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Winton Shire Council</txt></block></li><li id="sch.7-para1-oc.46" guid="_24ff4fb0-8b20-4b16-a246-d583e80f1253" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Woorabinda Aboriginal Shire Council</txt></block></li><li id="sch.7-para1-oc.47" guid="_d033e4e4-26f7-4834-92f6-2ae1eae52659" provision.type="other" affected.by.uncommenced="0"><no/><block><txt break.before="0">Wujal Wujal Aboriginal Shire Council</txt></block></li></list></block></schedule><schedule id="sch.7A" guid="_1d7cb81d-26e8-4473-9fb4-cc45a7bbb52b" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 7A</no><heading id="sch.7A-he" guid="_88b0965a-6061-46e6-881d-f17917df67f6">Required standard for greywater from greywater (cooling tower) treatment plants</heading><sourceref id="sch.7A-ref" guid="_ed287495-62c1-473a-9b06-c56d707173ac" affected.by.uncommenced="0"><intref refid="sec.103B" target.guid="_667ec218-2b48-41a3-b165-575acf08e3b9" check="valid">section&#160;103B</intref><intref refid="sec.103B-ssec.4" target.guid="_e2352701-4255-41bc-a789-48b9c0d4f966" check="valid">(4)</intref></sourceref><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.7A-tbl" guid="_278392fc-735d-4bb7-ad14-8196752fa818" heading.align="left" font.size="12.pt"><tgroup cols="2" colsep="1" rowsep="1" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.721in"/><colspec colnum="2" colname="2" colwidth="2.287in"/><thead><row rowsep="1" id="sch.7A-tbl-tblh-tblr" guid="_04dd9670-8b16-44b0-916f-e87d12179a97"><entry colname="1" id="sch.7A-tbl-tblh-tblr-tble1" guid="_fd307056-9970-4fed-a72f-71dc2b620cb2"><block><txt break.before="1">column 1</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblh-tblr-tble2" guid="_b20e7f98-72a8-419f-ae7b-592e605898f6"><block><txt break.before="1">column 2</txt></block></entry></row><row rowsep="1" id="sch.7A-tbl-tblh-tblr-oc.2" guid="_d144db8e-a288-4860-b908-21c2d06566fa"><entry colname="1" id="sch.7A-tbl-tblh-tblr-oc.2-tble1" guid="_949c2edf-a287-4dd5-9e85-e2c6e24f99b6"><block><txt break.before="1">Parameter</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblh-tblr-oc.2-tble2" guid="_dd78fae9-2fc3-4734-a18d-4084a163faf0"><block><txt break.before="1">Required concentration or value</txt></block></entry></row></thead><tbody><row rowsep="1" id="sch.7A-tbl-tblr" guid="_32e6965c-6b56-4479-81b1-9e0475aa9f7a"><entry colname="1" id="sch.7A-tbl-tblr-tble1" guid="_3706c7ea-3e90-4784-af84-4d15ce9690b7"><block><txt break.before="1">five-day biochemical oxygen demand (BOD5)</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-tble2" guid="_19f2a292-09d9-41e8-9a43-97404ce0065e"><block><txt break.before="1">less than 5mg/L</txt></block></entry></row><row rowsep="1" id="sch.7A-tbl-tblr-oc.2" guid="_944b9e01-8be3-46aa-94f2-8b17b9d4d469"><entry colname="1" id="sch.7A-tbl-tblr-oc.2-tble1" guid="_60ecef2d-6177-44ce-a707-63b511fbc668"><block><txt break.before="1">turbidity</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-oc.2-tble2" guid="_14ff5b98-4f49-4778-a9a6-528eb9260839"><block><txt break.before="1">less than 2 NTU</txt></block></entry></row><row rowsep="1" id="sch.7A-tbl-tblr-oc.3" guid="_b6751166-57ea-43d6-b938-334473f92e27"><entry colname="1" id="sch.7A-tbl-tblr-oc.3-tble1" guid="_1aa373c6-7afa-4f7e-877c-35ea30359bdf"><block><txt break.before="1">free available chlorine</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-oc.3-tble2" guid="_e7c67c48-44d1-4ac2-9d3b-a0f4b143d4e8"><block><txt break.before="1">more than 0.5mg/L</txt></block></entry></row><row rowsep="1" id="sch.7A-tbl-tblr-oc.4" guid="_cf3abd8b-c73d-4d32-a102-1174d23c8711"><entry colname="1" id="sch.7A-tbl-tblr-oc.4-tble1" guid="_5936a858-8c33-4967-8e29-49b222ce757e"><block><txt break.before="1">heterotrophic colony count</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-oc.4-tble2" guid="_51b13e69-bf19-4419-abac-8c065a0676fe"><block><txt break.before="1">less than 500 cfu/100mL</txt></block></entry></row><row rowsep="1" id="sch.7A-tbl-tblr-oc.5" guid="_2724ec61-604d-4509-84a7-34d5ed5dfb05"><entry colname="1" id="sch.7A-tbl-tblr-oc.5-tble1" guid="_de2af8c0-2cbe-4116-a759-9963fa272de5"><block><txt break.before="1"><i>E. coli</i></txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-oc.5-tble2" guid="_4adef650-de99-46af-b20f-c108ba5db137"><block><txt break.before="1">no detectable cfu/100mL</txt></block></entry></row><row rowsep="1" id="sch.7A-tbl-tblr-oc.6" guid="_aaba681d-472c-4965-b14e-d31646cb060b"><entry colname="1" id="sch.7A-tbl-tblr-oc.6-tble1" guid="_4b5e2c32-6961-4cda-b830-6bb49a723143"><block><txt break.before="1">Total <i>legionella</i> count</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-oc.6-tble2" guid="_6b5acc0e-5fdc-4d45-b3b1-105706576f9a"><block><txt break.before="1">no detectable cfu/100mL</txt></block></entry></row><row rowsep="0" id="sch.7A-tbl-tblr-oc.7" guid="_dbf9999f-d994-406b-82eb-fa1155af19af"><entry colname="1" id="sch.7A-tbl-tblr-oc.7-tble1" guid="_d27d8ba4-7afa-4a3d-89a0-da6ec047a3f0"><block><txt break.before="1">pH</txt></block></entry><entry colname="2" id="sch.7A-tbl-tblr-oc.7-tble2" guid="_b3e0a7d2-50bd-4b31-a10b-25bed0979a79"><block><txt break.before="1">from 6 to 8.5</txt></block></entry></row></tbody></tgroup></table></block><historynote><txt break.before="1"><b>sch&#160;7A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.20" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_1e20b319-eedc-4b9f-b6c1-2e6988f194e3" valid.date="as.made" check="valid">s 20</legref></txt></historynote></schedule><schedule id="sch.8" guid="_93f0760f-c5c7-4977-b728-2912f08722ee" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 8</no><heading id="sch.8-he" guid="_28aedb25-f61b-4c92-911d-7b8b186c6f82">Fees</heading><sourceref id="sch.8-ref" guid="_b47bef3d-ac24-4cf0-b9fe-c223e9c71dff" affected.by.uncommenced="0"><intref refid="sec.14" target.guid="_a1698b4d-ced3-4af8-b134-e83758d8bd8a" check="valid">sections&#160;14</intref><intref refid="sec.14-ssec.1" target.guid="_c90c767a-55c1-4a49-88c3-ab54405b3d42" check="valid">(1)</intref><intref refid="sec.14-ssec.1-para1.d" target.guid="_37155c8d-60ca-46c8-bb5c-94006aecb23d" check="valid">(d)</intref>, <intref refid="sec.118" target.guid="_0d3484a9-644a-46d0-92f7-3f0e137b728a" check="valid">118</intref><intref refid="sec.118-ssec.1" target.guid="_5d3d24be-c72b-44e2-a046-ecdc9e8ed284" check="valid">(1)</intref>, <intref refid="sec.122" target.guid="_aef64642-0c2a-4705-9bc0-1a99b7c981ae" check="valid">122</intref> and <intref refid="sec.123" target.guid="_d89395bc-d229-4aa6-bb5c-4e69199d8d14" check="valid">123</intref></sourceref><block><table frame="none" colsep="0" rowsep="0" orient="port" id="sch.8-tbl" guid="_930b2cb8-8b9e-4f88-8582-3a7a00bb1992" heading.align="left" font.size="12.pt"><tgroup cols="3" colsep="0" rowsep="0" tgroupstyle="3columnUnRuled"><colspec colnum="1" colname="1" colwidth="0.333in" colsep="0"/><colspec colnum="2" colname="2" colwidth="3.917in" colsep="0"/><colspec colnum="3" colname="3" colwidth="0.750in" colsep="0"/><thead><row rowsep="0" id="sch.8-tbl-tblh-tblr" guid="_423b5c45-ebd7-40b3-b226-7f5914f3c337"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblh-tblr-tble1" guid="_282d396f-de74-4e0a-9883-433a5b623131"><block><txt break.before="1"/></block></entry><entry colname="2" align="left" valign="top" id="sch.8-tbl-tblh-tblr-tble2" guid="_b10abed2-60f9-4bfb-ab42-b979dd0bc6c2"><block><txt break.before="1"/></block></entry><entry colname="3" align="right" valign="top" id="sch.8-tbl-tblh-tblr-tble3" guid="_11f065d4-ebae-4cae-81a0-90fdd0216477"><block><txt break.before="1">Fee units</txt></block></entry></row></thead><tbody><row rowsep="0" id="sch.8-tbl-tblr" guid="_f55b7bbc-cb2e-4996-9c67-e83faa526b3f"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-tble1" guid="_536daa51-91cd-4074-ac61-0ce701524f12"><block><txt break.before="1">1</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-tble2" guid="_ee67d20e-80b2-412f-9c5b-79d4b39dc323"><block><txt break.before="1" dot.leaders="leaders">Application for a plumbers licence alone (Act, s 16(c)(ii)), if the licence is to be granted for—</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-tble3" guid="_6a7b7b51-a33c-4a72-beec-f91a0fe13fc0"><block><txt break.before="1"/></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.2" guid="_e6ac7775-fbf0-4bc2-b1ab-698476d2ec06"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.2-tble1" guid="_43c4299e-b82a-4337-b810-1e82ec823a3c"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.2-tble2" guid="_0c14887f-7d5b-45da-9deb-c7c0b1026a1a"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.2-tble2-para1.a" guid="_e4e8f423-d780-41fc-a975-62a75d22e88b" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.2-tble3" guid="_736b55c8-8c84-4e1a-8995-36b2fb1093b8"><block><txt break.before="1">148.15</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.3" guid="_6fa3edbe-2c33-49e7-a3b9-95ea29c18e27"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.3-tble1" guid="_1e69c292-6ea2-49db-992b-b658704497a5"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.3-tble2" guid="_59108d75-9ea9-460e-9a0f-7a7ac1f652c8"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.3-tble2-para1.b" guid="_1f8ebe03-4579-4285-85c0-72c6df9269ef" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.3-tble3" guid="_6a089cce-82f9-4f31-9416-990a6ce7f177"><block><txt break.before="1">226.35</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.4" guid="_209ba0fa-ec27-4990-b463-215fe4eab181"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.4-tble1" guid="_ab636213-14f4-43cc-bd54-f48ffd7548fa"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.4-tble2" guid="_8219ec46-e40f-45c5-ac68-13d393c25fd2"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.4-tble2-para1.c" guid="_919dfd10-1768-4cd4-92af-7980cef6d25f" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.4-tble3" guid="_ac9f3523-bd65-4e33-a3cd-c4e287e0babb"><block><txt break.before="1">304.50</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.5" guid="_d485b8c4-08b3-49c5-842b-e38032a534c9"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.5-tble1" guid="_86097f18-254b-429b-be03-ec6b06528818"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.5-tble2" guid="_a0065568-101f-4bbd-bef2-ebb7c58bc3db"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.5-tble2-para1.d" guid="_16cfe119-cd41-492b-b97f-3d0270f835fa" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.5-tble3" guid="_539e2664-4a33-4d1b-810c-604a85a5346a"><block><txt break.before="1">382.65</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.6" guid="_4bac1dc1-d052-42c0-8d45-d78afee816f4"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.6-tble1" guid="_827322f7-4835-44a7-aced-3d420600dc28"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.6-tble2" guid="_e3d337eb-21c3-44fe-a961-fe3ac2af9e8d"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.6-tble2-para1.e" guid="_bb2bcfe9-c020-4af4-90f4-89e74f6ab7d4" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.6-tble3" guid="_9ee77021-a61b-4ff1-af72-3e7d5efe34f8"><block><txt break.before="1">460.80</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.7" guid="_2f8fa1ac-2163-4d87-8568-f2a2da783f46"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.7-tble1" guid="_bdf05a20-9593-4d19-b8cd-91322729df79"><block><txt break.before="1">2</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.7-tble2" guid="_f5747e6d-8d45-4154-8060-4dbaf669b14c"><block><txt break.before="1" dot.leaders="leaders">Application for a drainers licence alone (Act, s 16(c)(ii)), if the licence is to be granted for—</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.7-tble3" guid="_cde26c1b-0ce5-463c-a6f0-1ef40d8f5164"><block><txt break.before="1"/></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.8" guid="_83052b7a-d3ca-4d2a-a3d9-cb3dda3b31a1"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.8-tble1" guid="_7050b28c-b0d2-4a9e-b8b3-099a049790a8"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.8-tble2" guid="_2e06e863-4ddb-444f-9b85-294b9aa348e3"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.8-tble2-para1.a" guid="_6b0bfd76-4969-40dc-b665-26b28fd94083" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.8-tble3" guid="_fefac0fe-8ff4-429a-a3ce-a8166fe97d63"><block><txt break.before="1">148.15</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.9" guid="_320b2272-512b-4207-8e9e-c53916e49fcd"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.9-tble1" guid="_c9c098f6-865a-4bbe-8463-c2159ffd927f"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.9-tble2" guid="_9fe9aa96-9650-465a-aadd-299c5c9105a7"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.9-tble2-para1.b" guid="_dca4debe-6d0a-4c34-a8b0-9e4d0a988332" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.9-tble3" guid="_b4a35c6f-6bac-4b14-a983-ae73a507b6ed"><block><txt break.before="1">226.35</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.10" guid="_aab976fa-9aab-41e1-84d7-93341afaacb8"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.10-tble1" guid="_a9198b35-2c29-4e43-839c-325e3a0bb4b8"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.10-tble2" guid="_e7705539-4714-4435-8276-d71654f6398c"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.10-tble2-para1.c" guid="_7a0685f4-e805-4b3b-a039-1584f2aeca3a" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.10-tble3" guid="_1a54871a-51bf-4841-87de-293f5f03975a"><block><txt break.before="1">304.50</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.11" guid="_b9c6eead-d3e7-450d-adcb-fe4fe57c3639"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.11-tble1" guid="_87efcf7a-3ea4-46ec-8563-965622544cf1"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.11-tble2" guid="_17b59072-271f-47f5-805c-24ebe79665fa"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.11-tble2-para1.d" guid="_dca419f9-2676-4e23-8a00-b298a8701791" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.11-tble3" guid="_85acbc3c-ddc4-4fdc-81f7-9b7d3dd8863c"><block><txt break.before="1">382.65</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.12" guid="_9b1321e2-07af-4b4a-a169-5b0b9f6154da"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.12-tble1" guid="_3c1a9f60-a52f-47c4-9404-9e84098f8ac9"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.12-tble2" guid="_8d6dc264-0292-4d7f-9e52-f4a5c45b6395"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.12-tble2-para1.e" guid="_926b67b6-6857-4144-914f-613748280bf0" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.12-tble3" guid="_b39e4746-6418-41a7-bec0-e03c8eb77fe5"><block><txt break.before="1">460.80</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.13" guid="_f1228bc3-0ca4-4be6-a360-70e70b4eb30a"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.13-tble1" guid="_d3dc644c-b320-4e54-a6a2-dfaff94f52bf"><block><txt break.before="1">3</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.13-tble2" guid="_e90bd6f9-384f-4f0e-a626-b98a23553013"><block><txt break.before="1" dot.leaders="leaders">Combined application for a plumbers licence and a drainers licence (Act, s 16(c)(ii)), if the licences are to be granted for—</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.13-tble3" guid="_f4213c71-cde4-4123-b555-a0aa14ad0d42"><block><txt break.before="1"/></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.14" guid="_6f0d9a83-ed58-4145-9d72-531b101cb6cf"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.14-tble1" guid="_86d02d5e-a047-4605-88f9-68bff380e9ac"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.14-tble2" guid="_07f73a35-55f1-49a2-a61d-3d11b6cbb173"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.14-tble2-para1.a" guid="_44ec17bd-112d-42d6-80bc-e64745e83158" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.14-tble3" guid="_2ab56517-c69a-45fb-9809-13b1b5c86435"><block><txt break.before="1">296.30</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.15" guid="_bb1b4f2e-4642-4d93-a61e-ade040967466"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.15-tble1" guid="_f93e2553-28e1-4e69-a0d8-0d64b10a93f5"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.15-tble2" guid="_249824d1-d122-4a42-aa47-8380b04764fd"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.15-tble2-para1.b" guid="_9b50091b-aa73-4288-b09b-694f822bc2c6" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.15-tble3" guid="_d1afd5cb-12a3-46fd-a139-7d307ecbcb31"><block><txt break.before="1">374.45</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.16" guid="_0bd758db-da4f-4d11-824e-33cd3a3f6012"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.16-tble1" guid="_80dc7c3a-cbc3-4161-b00d-11740861be4e"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.16-tble2" guid="_a0a37c4d-f65d-43bc-83b1-befbf4b8eeea"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.16-tble2-para1.c" guid="_1a867c71-c284-47d1-ae8e-47c0c8247e0a" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.16-tble3" guid="_4b4dc0cf-94ae-4bc2-8165-c55ab41ffcdf"><block><txt break.before="1">452.60</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.17" guid="_4ad09873-420a-405c-b2c4-b23e09ed43de"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.17-tble1" guid="_6c09d419-01f3-4452-ab7a-56c37ef06370"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.17-tble2" guid="_76de12c7-6a06-4339-a8f9-27ca2abbbafa"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.17-tble2-para1.d" guid="_1a83e740-dd87-45e8-92ed-f0aab1d1e36e" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.17-tble3" guid="_647b56e0-7d8b-4918-9109-89ba59d9a5a8"><block><txt break.before="1">530.75</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.18" guid="_2e2e44c9-d900-4ef4-bb7c-d405369ccc28"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.18-tble1" guid="_9da75762-e793-4c11-9a13-e2895376250e"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.18-tble2" guid="_7658e435-787d-486b-87a8-6593b1675a88"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.18-tble2-para1.e" guid="_4da6f6d6-d92c-4e2e-94cb-1f109e42383c" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.18-tble3" guid="_36741a11-82a9-43dc-aaa6-12839313ea85"><block align="right"><txt break.before="1">608.95</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.19" guid="_7c401161-1733-4bc9-857d-d538f35aa241"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.19-tble1" guid="_1745ad5b-30d0-43a1-9397-44460201eb16"><block><txt break.before="1">4</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.19-tble2" guid="_edaa8fb4-a3cb-484e-aea7-12ca14c0e309"><block><txt break.before="1" dot.leaders="leaders">Application for a restricted licence (Act, s 16(c)(ii)), if the licence is to be granted for—</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.19-tble3" guid="_cdf08b6f-7806-4a3c-9039-a28ed4d89e8a"><block><txt break.before="1"/></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.20" guid="_c476b1e8-a014-46ec-b3f0-22f45b89c0b7"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.20-tble1" guid="_fc297a2f-6d0f-468a-9847-6b6b7f1a5e06"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.20-tble2" guid="_da2d0ae7-335d-494b-9740-d195acb2a1ac"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.20-tble2-para1.a" guid="_0f8d1589-df42-43ec-aa8c-9f99991cf8e2" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.20-tble3" guid="_e4a35517-53d7-4bc5-bb02-b0291ae1e126"><block><txt break.before="1">91.65</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.21" guid="_09012aa9-99d6-47f2-b1e6-e0c46847b22f"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.21-tble1" guid="_9d525055-970f-47bf-bd1c-14d66748fbe9"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.21-tble2" guid="_2bb2506e-5b7f-4663-ae70-8d73409c7c24"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.21-tble2-para1.b" guid="_33f1153d-75e3-48f0-94bf-b50b5680ed28" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.21-tble3" guid="_5495fe47-76fd-44cc-b5ab-ad489ec47df5"><block><txt break.before="1">169.80</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.22" guid="_6337a6ed-f26e-4b3f-b390-4b7e46fb9303"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.22-tble1" guid="_8f6f66b6-fa24-43d1-b648-45531c054180"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.22-tble2" guid="_3f2ff2fd-d6b2-4524-9db6-2d22942d0e83"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.22-tble2-para1.c" guid="_a5caa4a0-7e11-4606-866a-317d9704763f" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.22-tble3" guid="_bdfdd800-ce49-47a4-9932-3c14c0530cfe"><block><txt break.before="1">247.95</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.23" guid="_3b36f3db-7b0b-4ad2-a3ff-5084e286ecaa"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.23-tble1" guid="_95a205c3-929c-4a6b-bb3e-f5e9c3ee45e2"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.23-tble2" guid="_c9f409ab-dfc2-4a93-acac-dba15f78c5be"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.23-tble2-para1.d" guid="_8b849c3c-4f97-4575-9aad-4c229d1f691c" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.23-tble3" guid="_99d63d97-f888-40ae-9ff1-7c386f575aa3"><block><txt break.before="1">326.10</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.24" guid="_307d5b27-673d-4cfa-9d55-df962e147bd0"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.24-tble1" guid="_aa10c2ce-4938-4384-9de3-622c4ba4c7af"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.24-tble2" guid="_5d90e63d-ddb6-4291-a483-a8e4f76eb8a7"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.24-tble2-para1.e" guid="_127e6a93-ae7e-424e-872b-7ad2e59c84db" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.24-tble3" guid="_3a2d68ec-646a-4a9a-bdd5-c447e76f39c2"><block><txt break.before="1">404.25</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.25" guid="_5008ca4c-7194-421f-b931-6e7c9ecfcd46"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.25-tble1" guid="_22985f8e-cf95-4ae7-b6d0-ca19daae2b4c"><block><txt break.before="1">5</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.25-tble2" guid="_138df814-fea4-4a8b-80af-3493e2adeaee"><block><txt break.before="1" dot.leaders="leaders">Request to assess the equivalence of an alternative qualification for a licence mentioned in item 1, 2 or 4&#160; (s&#160;14(1)(d))</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.25-tble3" guid="_2690ebb5-4c0a-43d7-9233-d074499bbbe6"><block><txt break.before="1">29.55</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.26" guid="_59f0247d-e5c2-49fa-a885-52933265c825"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.26-tble1" guid="_43bc154c-c018-4d50-822f-0c61b52643b4"><block><txt break.before="1">6</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.26-tble2" guid="_49188513-e018-481e-a89b-ed72c76970d5"><block><txt break.before="1" dot.leaders="leaders">Application for a provisional licence (Act, s 16(c)(ii))</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.26-tble3" guid="_fc56749e-d310-4626-ada5-1cd9739a21c6"><block><txt break.before="1">68.70</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.27" guid="_baa99d57-7708-4984-b9a2-65252d92d3a7"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.27-tble1" guid="_5f874737-4768-432e-9ee1-fa6019878d3c"><block><txt break.before="1">7</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.27-tble2" guid="_8b82446d-b479-4fba-a1b0-d3d99b5dd5db"><block><txt break.before="1" dot.leaders="leaders">Application for an endorsement on a licence (Act, s 28(c)(ii))—for each endorsement</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.27-tble3" guid="_42eecf23-3f36-4fe8-bf2f-8fe55dcb1cb5"><block><txt break.before="1">16.15</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.28" guid="_e395dd7b-b6d4-44df-9b69-7276e72a0765"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.28-tble1" guid="_97b05636-c816-4cee-907b-c8b2fd240a92"><block><txt break.before="1">8</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.28-tble2" guid="_aeefc42d-ab87-4abc-93f1-2b98a52d14db"><block><txt break.before="1" dot.leaders="leaders">Application to renew, or application to restore, a plumber licence, drainer licence or restricted licence— </txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.28-tble3" guid="_397d12fb-fe91-45e4-9fe8-c677999606e2"/></row><row rowsep="0" id="sch.8-tbl-tblr-oc.29" guid="_f81dc8f1-07ea-42a3-b1a7-5637793f40fa"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.29-tble1" guid="_e7f7764a-d806-42a7-a085-bd73723bc260"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.29-tble2" guid="_9eba3639-dbd5-4b0a-aebc-d3dbcaf8d6f2"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.29-tble2-para1.a" guid="_0200d5b0-f867-4a81-b8a4-ebca734e2047" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">for an applicant who is an employee of a registered training organisation (Act, s 31(2)(c) or 33(2)(c)), if the licence is to be renewed or restored for—</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.29-tble3" guid="_cb7ecfe7-4aed-459f-a374-2b78b4de49a1"/></row><row rowsep="0" id="sch.8-tbl-tblr-oc.30" guid="_a26e12d4-5936-4da4-8233-0c414c1dcfc0"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.30-tble1" guid="_77f106e6-c113-4e0a-bda7-f61035764d60"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.30-tble2" guid="_aa8375cf-b5e4-4268-bf17-6ebd0812c4ee"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.30-tble2-para1" guid="_036a6b68-2503-45b1-b943-bc06fff3ebe7" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.30-tble2-para1-para2.i" guid="_ddee94b1-e8c6-4eec-9611-e577a6786b99" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.30-tble3" guid="_65a4f2c6-1157-4275-bfa2-a79eef6c5d06"><block><txt break.before="1">22.95</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.31" guid="_890b5f62-519b-4a4c-ba66-b22eef2f8cb1"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.31-tble1" guid="_d2e7f849-3a00-43f5-bab2-8d9aeda7e474"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.31-tble2" guid="_0f34d97a-cd22-44b7-91a1-dfaf03af5272"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.31-tble2-para1" guid="_4a2c65ef-57a2-42f2-b80a-0616c3e1ff64" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.31-tble2-para1-para2.ii" guid="_d56a09ac-d861-4fa2-a466-2cbf2867b319" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.31-tble3" guid="_f0e65010-61ef-48cb-884d-89f3ad72bbcc"><block><txt break.before="1">45.85</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.32" guid="_9cce14bc-076c-41ee-ae47-bf84cec68832"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.32-tble1" guid="_ddfd9cd8-acfc-40ed-9df6-f7cf7c5027a1"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.32-tble2" guid="_b38627d2-c9ee-4014-ab43-67dda96bc76d"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.32-tble2-para1" guid="_7764a25a-f087-49c3-bab2-df359a9bc7eb" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.32-tble2-para1-para2.iii" guid="_e0955e9f-dd2b-4528-8ccd-ad550b28fe62" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.32-tble3" guid="_99de2b91-8eb1-4185-b616-e850dfcc7d36"><block><txt break.before="1">68.80</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.33" guid="_88a1d597-e5f1-4f09-8560-bf47f0bfc484"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.33-tble1" guid="_c5ffc9fe-7268-4f07-a056-e6070869b3a4"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.33-tble2" guid="_cfbb445b-62cf-4a49-92d6-7f37b9ce8102"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.33-tble2-para1" guid="_de11cd78-045d-4cc5-b101-0b0c36fbe82c" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.33-tble2-para1-para2.iv" guid="_93769f1d-e4e8-4720-b834-aa20a744196a" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.33-tble3" guid="_f49255cb-84cb-4ed1-ae71-033fd9e2ee6e"><block><txt break.before="1">91.75</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.34" guid="_98694bdc-609e-4610-8d89-125502bf80fd"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.34-tble1" guid="_9e47fc1b-13eb-496b-88f0-223d90f943eb"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.34-tble2" guid="_29022458-9aa1-4219-b274-bbbcbcd20077"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.34-tble2-para1" guid="_191e2ad8-0f13-48c5-a808-5d120500c6f3" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.34-tble2-para1-para2.v" guid="_fce4273d-b770-48aa-9e41-d4f3c61762db" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.34-tble3" guid="_e0518dce-c54d-4b6b-8818-69b2acf20d64"><block><txt break.before="1">114.65</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.35" guid="_0972f1e2-233c-40a8-8681-03d941a41c7c"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.35-tble1" guid="_1cf67efc-5476-43c8-a1a5-b245046f2b3c"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.35-tble2" guid="_6fdc8cad-3b67-46fd-85ce-6dec76a2f786"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.35-tble2-para1.b" guid="_072839d7-424b-48a4-a05b-ad95b0183b01" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">for an applicant who has given a statutory declaration stating the applicant is retired and does not intend to carry out work for payment (Act, s 31(3) or 33(3)), if the licence is to be renewed or restored for—</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.35-tble3" guid="_91eda479-4268-4348-850a-0ab1b6ff71a9"/></row><row rowsep="0" id="sch.8-tbl-tblr-oc.36" guid="_ce19e9c2-8b01-460c-b39b-4a0587dfd27d"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.36-tble1" guid="_1207ece9-c0f8-4781-9e92-2f96ec24ff12"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.36-tble2" guid="_ebe3c951-3173-46c5-8cb7-bced05cb99f3"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.36-tble2-para1" guid="_16e0971c-b693-4b69-b5a8-7bd43d6aab92" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.36-tble2-para1-para2.i" guid="_0a9b4f27-ca1c-4bca-81f5-90d288f67453" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.36-tble3" guid="_d158b116-7e94-404c-9b09-af71d3749cc5"><block><txt break.before="1">22.95</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.37" guid="_a4e25234-9a49-45a1-9d2f-8c9fe094bb24"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.37-tble1" guid="_b7760415-0702-4149-92a2-9e57c1edcada"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.37-tble2" guid="_8d4714ba-9d5f-4fda-86cc-3520eca0eb3b"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.37-tble2-para1" guid="_157a8259-c4b3-4714-abb5-588d740356c5" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.37-tble2-para1-para2.ii" guid="_b476b703-19b5-41c7-9a83-e7366cbf3f52" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.37-tble3" guid="_dfa91563-7a72-401e-b09c-426382279a76"><block><txt break.before="1">45.85</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.38" guid="_7fa3c5cb-f49e-4665-bd13-390e416e4828"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.38-tble1" guid="_07dddee9-465f-44e0-bc50-b2bb9081898f"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.38-tble2" guid="_93768daf-cb03-4c45-9536-baa9a8e0ed69"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.38-tble2-para1" guid="_eb595483-e56c-4cd2-ba75-d963a6e29d7f" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.38-tble2-para1-para2.iii" guid="_d49a6a7e-94d7-485c-8a34-a316161ed356" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.38-tble3" guid="_54340f55-44c0-4e69-993e-a4a625720190"><block><txt break.before="1">68.80</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.39" guid="_7db64ba6-6833-43bb-8079-657c67e2e8ec"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.39-tble1" guid="_065156b3-66c8-4a5c-8ecd-df7b0f911ee5"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.39-tble2" guid="_df879d45-c220-4518-9390-42e6a31240ee"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.39-tble2-para1" guid="_99887559-7847-4631-bb99-ff455e154855" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.39-tble2-para1-para2.iv" guid="_deb18d87-0cf3-48f8-9087-ebb851413088" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.39-tble3" guid="_1aea0d30-0f7d-4ad7-b62c-aa5ca0c3a351"><block><txt break.before="1">91.75</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.40" guid="_2bb97cf0-a598-4c17-88b9-7b11e2f1c1c6"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.40-tble1" guid="_0cd9f70b-9d0c-4464-bfe8-fb1913e0fed7"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.40-tble2" guid="_e76c1d21-bc12-42a4-a5ed-6e699540416f"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.40-tble2-para1" guid="_d3dd12fb-41f5-425d-980b-887a5ee5fdb1" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.40-tble2-para1-para2.v" guid="_fb1bb06c-f229-4827-ad5f-68adcdb6841d" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.40-tble3" guid="_9c8181d1-fa2f-43fd-b47b-9d862927d3ca"><block><txt break.before="1">114.65</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.41" guid="_ffb2ffa4-f7d9-4c23-a5bf-17a6684ef808"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.41-tble1" guid="_76fee5e6-3104-48fc-a086-d3809114c5eb"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.41-tble2" guid="_1c41896a-6e66-447b-b273-a7af7dce5099"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.41-tble2-para1.c" guid="_d25e44eb-30db-4b27-a960-b561f25c418d" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="1">for another applicant (Act, s 31(2)(c) or 33(2)(c)), if the licence is to be renewed or restored for—</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.41-tble3" guid="_374d6000-6557-4dc4-9a05-5b17df183e9c"/></row><row rowsep="0" id="sch.8-tbl-tblr-oc.42" guid="_21755dcd-fe71-4e64-8735-5460708e643f"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.42-tble1" guid="_0a3b5fc1-d8f7-4405-ba9d-073bce977ecd"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.42-tble2" guid="_466e2d8c-0d46-4c46-980b-6d41b739d48b"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.42-tble2-para1" guid="_b836d8a3-68e3-4151-83e1-0a8037412679" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.42-tble2-para1-para2.i" guid="_fbfb141c-13fd-418c-a52e-936f8a3504ad" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="1">1 year</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.42-tble3" guid="_0b317b9c-bbab-492e-b21b-2cae0f77fa00"><block><txt break.before="1">78.15</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.43" guid="_92e61cef-50dc-42b2-a805-328bd1099a59"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.43-tble1" guid="_950ebea5-6423-4a72-89d2-bab7d673ab18"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.43-tble2" guid="_35688e08-c394-46ab-ad2e-665bb6637a97"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.43-tble2-para1" guid="_be38b99a-1060-4b05-b7a7-fba25059316d" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.43-tble2-para1-para2.ii" guid="_bc75891d-a988-47db-b3e5-1087696f0d4a" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="1">2 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.43-tble3" guid="_d9bb6641-b3e5-4ab3-9b42-4c6a4271a0c1"><block><txt break.before="1">156.30</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.44" guid="_193d9aa3-09be-4e38-9a67-7b40b5ef2429"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.44-tble1" guid="_18ff53a7-2713-468d-87fc-82202808725a"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.44-tble2" guid="_191f39d0-4c79-45b2-a15d-78586df5df3d"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.44-tble2-para1" guid="_a0eb8e87-f36f-4af8-bd7c-b205fd58640d" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.44-tble2-para1-para2.iii" guid="_d9cca02f-0807-4309-b356-3b16b0a11c3e" affected.by.uncommenced="0"><no>(iii)</no><block><txt break.before="1">3 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.44-tble3" guid="_0cd37791-9bde-470d-a885-627994b89b7c"><block><txt break.before="1">234.45</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.45" guid="_82d669e5-f813-40c5-87d8-02d9660fc53f"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.45-tble1" guid="_62240bf8-beed-4b73-b949-bd48f04431d4"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.45-tble2" guid="_dcaba18d-875c-4702-a910-169fe3e08986"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.45-tble2-para1" guid="_731c040f-fcbd-414d-87c5-546eb50cc9d3" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.45-tble2-para1-para2.iv" guid="_8c1a1960-b4dd-4977-a658-9249843f4e97" affected.by.uncommenced="0"><no>(iv)</no><block><txt break.before="1">4 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.45-tble3" guid="_ffad1bc5-9a79-458a-9888-5b20b58e0229"><block><txt break.before="1">312.65</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.46" guid="_585f6524-c3e1-43a9-921d-5519a9dc849a"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.46-tble1" guid="_c1e7a1c7-89d2-417b-84b2-642409e5fbf1"/><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.46-tble2" guid="_3d395d2d-ddf5-4016-91ef-5021c989aefe"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.46-tble2-para1" guid="_a69355a9-4e99-40c6-b5a8-363ed4109a9e" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.46-tble2-para1-para2.v" guid="_fa4ce2c8-e525-4530-a6d9-e3e957786e20" affected.by.uncommenced="0"><no>(v)</no><block><txt break.before="1">5 years</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.46-tble3" guid="_db31007c-9891-407b-a2bf-ff83d1c18278"><block><txt break.before="1">390.85</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.47" guid="_e162bcf6-0098-4118-99c3-3fe733a16dd5"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.47-tble1" guid="_9295b7db-6585-4147-87d4-5c09e05ef84b"><block><txt break.before="1">9</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.47-tble2" guid="_da91006b-b6bb-4013-bbc0-5a4eb635ef8c"><block><txt break.before="1" dot.leaders="leaders">Additional fee for an application to restore a plumber licence, drainer licence or restricted licence (s 122)</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.47-tble3" guid="_08a77095-d5b3-4980-8fd8-41d4716fa861"><block><txt break.before="1">78.15</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.48" guid="_cb3b08a5-fe5c-4d6f-9596-c7ce491124f6"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.48-tble1" guid="_3024b8ff-d8e0-4eb6-a899-a4ffc4223bcb"><block><txt break.before="1">10</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.48-tble2" guid="_520e51ac-1a08-496d-b521-9ea6b2957a1a"><block><txt break.before="1" dot.leaders="leaders">Application for review of the conditions of a licence (Act, s 35(3)(b))</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.48-tble3" guid="_54236333-80ed-4f10-ae4a-bd5ed2f2f6bc"><block><txt break.before="1">68.70</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.49" guid="_2fea878a-88a5-4afd-9d9b-df69c73758e7"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.49-tble1" guid="_73ffd254-8894-454a-9a31-4e696b05b2b0"><block><txt break.before="1">11</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.49-tble2" guid="_0c9d59fd-12e5-4126-a66a-ef1a181c224d"><block><txt break.before="1" dot.leaders="leaders">Application to replace a licence (Act, s 42(2)(b))</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.49-tble3" guid="_fd9b6034-5779-424a-910e-e2d2bc2a66a9"><block><txt break.before="1">29.55</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.50" guid="_91100f59-d48c-4a59-a3df-ec21fce1306a"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.50-tble1" guid="_901ced43-987a-4e45-9164-873020f6b48a"><block><txt break.before="1">12</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.50-tble2" guid="_b1ae32e2-f3f8-4591-88be-1d37fcfd7df6"><block><txt break.before="1" dot.leaders="leaders">Request for a certified copy of a licence (Act, s 43)</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.50-tble3" guid="_c953052f-88ba-4bd0-8c6e-4b7d04d1e6d9"><block><txt break.before="1">29.55</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.51" guid="_834c5b0f-67f5-4fc7-af97-43ebde35245e"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.51-tble1" guid="_6f1f20dd-b937-4d4d-b81f-6536fc73d4ce"><block><txt break.before="1">13</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.51-tble2" guid="_98bcd823-b811-40e4-a6c2-ab047ce49352"><block><txt break.before="1" dot.leaders="leaders">Administration fee (s 123)</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.51-tble3" guid="_19c90b8f-7c10-48a2-b3a4-c1ed58d05c3e"><block><txt break.before="1">71.40</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.52" guid="_f47f8535-0df7-448c-bf4a-3a42a76f2771"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.52-tble1" guid="_f38808b8-c651-413b-8b58-65b3a4532f3e"><block><txt break.before="1">14</txt></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.52-tble2" guid="_8dc6fb77-d388-47ed-9893-6f89c8a5d6d1"><block><txt break.before="1" dot.leaders="leaders">Notice of notifiable work (Act, s 83(1)(b)), given by—</txt></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.52-tble3" guid="_0dc85e67-99bc-4ee6-8a79-d8c95cdfcdb6"/></row><row rowsep="0" id="sch.8-tbl-tblr-oc.53" guid="_6da42671-b962-4f5e-a32e-7f5b5f38f85c"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.53-tble1" guid="_66d3f34e-6096-4c01-8d80-0bf27f65cd05"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.53-tble2" guid="_4b00cf51-bd94-4c69-8785-2e8fd7638129"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.53-tble2-para1.a" guid="_32e1fe48-b695-44a1-87a4-d1d183fc7516" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="1">a relevant person that is a public sector entity</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.53-tble3" guid="_1deccc67-9ea1-4c27-b9d8-cf0bcbe8bb07"><block><txt break.before="1">nil</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.54" guid="_3ee3c8cc-64e1-4cb2-a955-592086396783"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.54-tble1" guid="_fc52d938-5c19-4e33-a78d-741f5cb37eb0"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.54-tble2" guid="_b9a44438-caa3-487e-b17e-a96812579ab9"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.54-tble2-para1.b" guid="_97c29f41-c4de-4c37-8610-a35044cb0543" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="1">another relevant person—</txt></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.54-tble3" guid="_eb864034-e989-43d0-afcc-e84024798217"><block><txt break.before="1"/></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.55" guid="_16827602-90c6-490c-8346-1f4b2cde81fd"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.55-tble1" guid="_310e0ad0-ee89-431c-8175-8fd3a22559d1"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.55-tble2" guid="_4a6986c0-a331-4e1b-84d1-cfc1bc4ce18f"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.55-tble2-para1" guid="_e9873b76-f7d8-45dd-ab8a-6e57c17f3bad" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.55-tble2-para1-para2.i" guid="_5e726cc8-de48-4c09-b3ae-189f0b1cde27" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="1">if the notice is given in electronic form</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.55-tble3" guid="_3b8e1918-2753-4419-bc0b-d6db956f2509"><block><txt break.before="1">32.55</txt></block></entry></row><row rowsep="0" id="sch.8-tbl-tblr-oc.56" guid="_5c0eb864-b37c-4c55-b2e6-a5bfa3a0f452"><entry colname="1" align="left" valign="top" id="sch.8-tbl-tblr-oc.56-tble1" guid="_afe2461a-b789-415f-82ba-75fd7507d1fc"><block><txt break.before="1"/></block></entry><entry colname="2" align="justify" valign="top" id="sch.8-tbl-tblr-oc.56-tble2" guid="_8e44f2a7-61e2-48b7-9870-57031f29c533"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.56-tble2-para1" guid="_7b003dd2-8cc7-4391-b025-f0dc2244cac6" affected.by.uncommenced="0"><block><tlist number.type="default"><tli id="sch.8-tbl-tblr-oc.56-tble2-para1-para2.ii" guid="_d3655727-b04e-4d76-b3b2-3eb577b82f60" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="1">if the notice is given in hard copy form</txt></block></tli></tlist></block></tli></tlist></block></entry><entry colname="3" align="right" valign="bottom" id="sch.8-tbl-tblr-oc.56-tble3" guid="_be267b80-94d5-4227-9af6-b487c499fa7c"><block><txt break.before="1">43.95</txt></block></entry></row></tbody></tgroup></table></block><historynote><txt break.before="1"><b>sch&#160;8</b> sub <legref jurisd="QLD" type="subordleg" valid.date="as.made" check="invalid">2019 SL&#160;No.&#160;123</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2019-0121" target.version.series="338f067d-ceaa-4234-8ac7-da8db1148a0e" target.guid="_549d8669-baa0-497b-a034-8f08ea673100" valid.date="as.made" check="valid">s 12</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0119" target.version.series="709734de-1f83-42dc-a78e-2618c91fc926" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;119</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2020-0119" target.version.series="709734de-1f83-42dc-a78e-2618c91fc926" target.guid="_94d4dd2e-0c54-4e3c-b7eb-1bb14a59fddf" valid.date="as.made" check="valid">s 12</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2021-0083" target.version.series="4274d1a4-c92b-4651-bf74-6f1bb9996a6f" valid.date="as.made" check="valid">2021 SL&#160;No.&#160;83</legref> <legref jurisd="QLD" type="subordleg" refid="sec.16" target.doc.id="sl-2021-0083" target.version.series="4274d1a4-c92b-4651-bf74-6f1bb9996a6f" target.guid="_f1a5eaaf-9436-44a4-8d7b-7745fbd0aa44" valid.date="as.made" check="valid">s 16</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0078" target.version.series="82776cff-31e6-4fed-99e8-2a26b5414d50" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;78</legref> <legref jurisd="QLD" type="subordleg" refid="sec.17" target.doc.id="sl-2022-0078" target.version.series="82776cff-31e6-4fed-99e8-2a26b5414d50" target.guid="_69c2889e-d1b2-441d-bce6-52c612b008ef" valid.date="as.made" check="valid">s 17</legref></txt></historynote></schedule><schedule id="sch.9" guid="_5ab2a027-321a-4d67-8d54-fa015469136e" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 9</no><heading id="sch.9-he" guid="_2d271b4b-586d-4b3c-900a-f927d0c47614">Associated QBCCA licences for occupational licences</heading><sourceref id="sch.9-ref" guid="_32cefad3-137b-44f2-a0fd-3b6182d49c94" affected.by.uncommenced="0"><intref refid="sec.119" target.guid="_9443934a-c6dd-4099-9c73-dc9d30cdc00b" check="valid">section&#160;119</intref></sourceref><block><table frame="all" colsep="1" rowsep="1" orient="port" id="sch.9-tbl" guid="_d142e1f3-6dba-4251-9c1e-73571dacb3f2" heading.align="left" font.size="10.pt"><tgroup cols="2" colsep="1" rowsep="1" align="justify" tgroupstyle="Ruled2column"><colspec colnum="1" colname="1" colwidth="2.265in"/><colspec colnum="2" colname="2" colwidth="2.752in"/><thead><row rowsep="1" id="sch.9-tbl-tblh-tblr" guid="_3cb9b7c7-775c-4c39-afa6-379aafc664b2"><entry colname="1" id="sch.9-tbl-tblh-tblr-tble1" guid="_7a295cd9-0e8d-4c9d-bdee-6283f27902da"><block><txt break.before="1">Column 1</txt><txt break.before="1">Occupational licence</txt></block></entry><entry colname="2" id="sch.9-tbl-tblh-tblr-tble2" guid="_f5b839da-ad32-4989-b87b-a08d5a24be1b"><block><txt break.before="1">Column 2</txt><txt break.before="1">Associated QBCCA licences</txt></block></entry></row></thead><tbody><row rowsep="1" id="sch.9-tbl-tblr" guid="_47461056-ac4a-4e80-8164-96bc2ed52939"><entry colname="1" id="sch.9-tbl-tblr-tble1" guid="_e7fde1b8-4099-4a75-9026-2f6657882608"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-tble1-para1.1" guid="_7c8b24e6-692f-4c22-ac38-cddfd8b71944" affected.by.uncommenced="0"><no>1</no><block><txt break.before="1">plumbers licence</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-tble2" guid="_e3b51bb8-bcf6-479e-be25-523549bbee99"><block><txt break.before="1">plumbing and drainage licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.18" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">part&#160;18</legref></txt><txt break.before="1">plumbing and draining restricted to plumbing licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sec.60" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_79e794d2-9410-4e2e-919f-8ee243615157" check="valid">section&#160;60</legref><legref jurisd="QLD" type="subordleg" refid="sec60-ssec.1" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">(1)</legref></txt><txt break.before="1">plumbing and draining restricted to tanks—water supply licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sec.60" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_79e794d2-9410-4e2e-919f-8ee243615157" check="valid">section&#160;60</legref><legref jurisd="QLD" type="subordleg" refid="sec60-ssec.1" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">(1)</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.2" guid="_ed4f2daf-392e-403d-8bef-97a6f740c9db"><entry colname="1" id="sch.9-tbl-tblr-oc.2-tble1" guid="_8b0102f3-ce7f-4891-8815-2eb69ffc021f"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.2-tble1-para1.2" guid="_66070fe9-f25e-4181-84b0-0f017d036220" affected.by.uncommenced="0"><no>2</no><block><txt break.before="1">drainers licence</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.2-tble2" guid="_42efbb75-35cf-42e3-a0f3-649db0cf4e90"><block><txt break.before="1">plumbing and drainage licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.18" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">part&#160;18</legref></txt><txt break.before="1">drainage licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.19" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">part&#160;19</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.3" guid="_5f4bd9b0-d421-4488-b1f5-5726d5769ec5"><entry colname="1" id="sch.9-tbl-tblr-oc.3-tble1" guid="_c103152c-ca7a-4be3-a6c5-a8afa39518fb"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.3-tble1-para1.3" guid="_8c2b6bad-c4fc-4ce3-b07b-877dde65b893" affected.by.uncommenced="0"><no>3</no><block><txt break.before="1">water plumber—gas licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 1 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 1, column 2 of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.3-tble2" guid="_a6b80716-27ea-4652-9a18-3f53c97c1753"><block><txt break.before="1">gasfitting licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.36" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">part&#160;36</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.4" guid="_4a46153c-d8d2-484c-9961-14b04348c23b"><entry colname="1" id="sch.9-tbl-tblr-oc.4-tble1" guid="_3f604742-6755-4db1-b3c0-6df3ffaf0024"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.4-tble1-para1.4" guid="_109c80fe-506e-4508-b3e6-87b1ecfb0e70" affected.by.uncommenced="0"><no>4</no><block><txt break.before="1">water plumber—irrigation licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 3 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 3, column 2 of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.4-tble2" guid="_b939859d-0cbf-4226-afa8-78babba88b40"><block><txt break.before="1">irrigation licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.21" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">part&#160;21</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.5" guid="_af2f76a8-a90d-4b05-a0fc-b9cd89c3d67b"><entry colname="1" id="sch.9-tbl-tblr-oc.5-tble1" guid="_c5a7a8a4-d329-4af1-9c5d-c2151984587d"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.5-tble1-para1.5" guid="_a8268077-32e2-4e6a-a37d-4404231a7ad0" affected.by.uncommenced="0"><no>5</no><block><txt break.before="1">water plumber—fire protection (hydrants and hose reels) licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 4 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 4, column 2 of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.5-tble2" guid="_f6d8d161-ecfe-4088-a029-8ccba73b57fb"><block><txt break.before="1">fire protection—water-based fire system stream—install and maintain—restricted to commercial and industrial types licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-pt.26" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_33413df8-752b-4ca6-9276-27144fb743d5" check="valid">part&#160;26</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-sec.1" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_f15b220d-50ff-408e-8559-04f5ccf35037" check="valid">section&#160;1</legref><legref jurisd="QLD" type="subordleg" refid="sch.2-sec.1-ssec.4" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">(4)</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.6" guid="_a6c1342b-ae3c-445b-bb5d-346c02e260bf"><entry colname="1" id="sch.9-tbl-tblr-oc.6-tble1" guid="_fcdb7fd9-5bad-4a83-b68b-1b8678c24ee0"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.6-tble1-para1.6" guid="_ac66ffc5-b0cf-4d61-b378-972a94daea74" affected.by.uncommenced="0"><no>6</no><block><txt break.before="1">water plumber—fire protection (commercial and industrial) licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 5 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 5, column 2 of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.6-tble2" guid="_aaad2463-a1cc-49db-804f-b475d12d4919"><block><txt break.before="1">fire protection—water-based fire system stream—install and maintain—restricted to commercial and industrial types licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-pt.26" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_33413df8-752b-4ca6-9276-27144fb743d5" check="valid">part&#160;26</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-sec.1" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_f15b220d-50ff-408e-8559-04f5ccf35037" check="valid">section&#160;1</legref><legref jurisd="QLD" type="subordleg" refid="sch.2-sec.1-ssec.4" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">(4)</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.7" guid="_f61da28e-c108-48ca-b5b4-7a8e22bebece"><entry colname="1" id="sch.9-tbl-tblr-oc.7-tble1" guid="_3abb3270-6397-46e7-bc3c-4aaafa8d5f14"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.7-tble1-para1.7" guid="_99a1873e-0dd6-4f4a-8a75-b477c2bc361a" affected.by.uncommenced="0"><no>7</no><block><txt break.before="1">water plumber—fire protection (domestic and residential) licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 6 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 6, column 2 of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.7-tble2" guid="_1d0c0988-bafe-48a6-afb6-6da1e2f5443d"><block><txt break.before="1">fire protection—water-based fire system stream—install and maintain—restricted to domestic and residential types licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-pt.26" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_33413df8-752b-4ca6-9276-27144fb743d5" check="valid">part&#160;26</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-sec.1" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_f15b220d-50ff-408e-8559-04f5ccf35037" check="valid">section&#160;1</legref><legref jurisd="QLD" type="subordleg" refid="sch.2-sec.1-ssec.5" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">(5)</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.8" guid="_4aeebaf5-eeea-4ce1-bd6c-f0f05358f1e0"><entry colname="1" id="sch.9-tbl-tblr-oc.8-tble1" guid="_2d2f4599-6c32-4beb-8b16-f6a6662a065d"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.8-tble1-para1.8" guid="_b57c67e2-e871-4b96-9c7a-96a4d28051b4" affected.by.uncommenced="0"><no>8</no><block><txt break.before="1">water plumber—water and sanitary licence mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 7 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 7, column 2 of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.8-tble2" guid="_30b109ed-6d72-4cbb-bc7f-34ce12d48c92"><block><txt break.before="1">mechanical services—plumbing licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.48" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="invalid">part&#160;48</legref></txt><txt break.before="1">mechanical services—plumbing occupational licence mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.3A" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_4184627c-fc9e-4546-855e-2adf074b33d2" check="valid">schedule&#160;3A</legref>, <legref jurisd="QLD" type="subordleg" refid="pt.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_41948f29-dfb0-4d18-9084-c4a9849cd153" check="valid">part&#160;2</legref></txt></block></entry></row><row rowsep="1" id="sch.9-tbl-tblr-oc.9" guid="_83f98e14-f309-4309-a63a-d9aaef275dc0"><entry colname="1" id="sch.9-tbl-tblr-oc.9-tble1" guid="_4fa4f806-f590-4d03-b0aa-4ae25f32e30c"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.9-tble1-para1.9" guid="_450652aa-e977-4560-b7a4-bbf6c28fdcf1" affected.by.uncommenced="0"><no>9</no><block><txt break.before="1">drainer—on-site sewage facility licence (maintenance) mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 8 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 8, column 2, <intref refid="sch.9-tbl-tblr-oc.9-tble1-para1.a" check="invalid">paragraph&#160;(a)</intref> of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.9-tble2" guid="_4a18e6ee-428a-4fd8-a524-5d826d310c78"><block><txt break.before="1">drainage—on-site sewage facility licence (maintenance) mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-pt.20" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_bc8c5ade-42c0-47df-8c5a-13c7363724f1" check="valid">part&#160;20</legref>, <legref jurisd="QLD" type="subordleg" check="invalid">section&#160;1</legref><legref jurisd="QLD" type="subordleg" check="invalid">(1)</legref></txt></block></entry></row><row rowsep="0" id="sch.9-tbl-tblr-oc.10" guid="_c2085414-7306-4c89-85ec-24400d985a3f"><entry colname="1" id="sch.9-tbl-tblr-oc.10-tble1" guid="_a1a0ede4-f989-409f-ae81-a99fc74e21ca"><block><tlist number.type="default"><tli id="sch.9-tbl-tblr-oc.10-tble1-para1.10" guid="_dcce38cf-b052-42b3-96e0-3dfc597427a6" affected.by.uncommenced="0"><no>10</no><block><txt break.before="1">drainer—on-site sewage facility licence (maintenance and installation) mentioned in <intref refid="sch.4" target.guid="_38f7165b-6a3a-4907-a75c-b4dc4ae43188" check="valid">schedule&#160;4</intref>, <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 8 for the scope of work stated in <intref refid="sch.4-pt.3" target.guid="_3f3bc639-8cf9-4343-b5ea-5a7ed7610014" check="valid">part&#160;3</intref>, item 8, column 2, <intref refid="sch.9-tbl-tblr-oc.10-tble1-para1.b" check="invalid">paragraph&#160;(b)</intref> of that schedule</txt></block></tli></tlist></block></entry><entry colname="2" id="sch.9-tbl-tblr-oc.10-tble2" guid="_15ab2cdd-920a-4d63-8d3a-5041d6eab1e1"><block><txt break.before="1">drainage—on-site sewage facility licence (maintenance and installation) mentioned in the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Regulation 2018</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_32dbdbd0-e6e1-4652-9213-f2e010e0b1e5" check="valid">schedule&#160;2</legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2-pt.20" target.doc.id="sl-2018-0138" target.version.series="896aacbe-c6e7-4bb2-aa09-297e4fc8a97e" target.guid="_bc8c5ade-42c0-47df-8c5a-13c7363724f1" check="valid">part&#160;20</legref>, <legref jurisd="QLD" type="subordleg" check="invalid">section&#160;1</legref><legref jurisd="QLD" type="subordleg" check="invalid">(2)</legref></txt></block></entry></row></tbody></tgroup></table></block><historynote><txt break.before="1"><b>sch&#160;9</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2020-0223" target.version.series="259a2c1f-6c46-4f25-bded-49e636e08a1c" valid.date="as.made" check="valid">2020 SL&#160;No.&#160;223</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2020-0223" target.version.series="259a2c1f-6c46-4f25-bded-49e636e08a1c" target.guid="_13403dbc-f3f3-4a32-b585-847d5ae5eba2" valid.date="as.made" check="valid">s 4</legref></txt></historynote></schedule><schedule id="sch.10" guid="_9b14f044-16d4-406a-a5ef-01515b4b359f" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 10</no><heading id="sch.10-he" guid="_a1bb4d6c-f8be-4542-9d34-ae06621ad8ee">Dictionary</heading><sourceref id="sch.10-ref" guid="_fce0d256-f745-441b-8ffa-e12d4532b931" affected.by.uncommenced="0"><intref refid="sec.3" target.guid="_f6aaa0d6-b9e7-4d5c-8e75-8e77124d3c46" check="valid">section&#160;3</intref></sourceref><block><deflist><definition id="sch.10-def.48hours_" guid="_a75a08aa-b1e4-4acd-83eb-d4443fcf7fee" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.48hours" guid="_4305bed4-e369-4baa-b2d8-cddf3f389206" type="definition">48 hours</defterm> means a period of 48 hours excluding any day that is not a business day within that period.</txt><note id="sch.10-def.48hours-note" guid="_30f242a4-93aa-4098-a008-be3f4980e1f7" type="example"><heading id="sch.10-def.48hours-note-he" guid="_94cb74f4-e37b-4718-ac95-c6c13f22c4c2">Example—</heading><block><txt break.before="1">A period of 48 hours after 10a.m. on a Friday is 10a.m on the next Tuesday, if the next Monday and Tuesday are business days.</txt></block></note></definition><definition id="sch.10-def.acceptedrepresentations_" guid="_2f742600-61ba-41bf-9fe9-d834dd61168b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.acceptedrepresentations" guid="_21a2ff3d-63e7-434d-892e-96a525793222" type="definition">accepted representations</defterm> see <intref refid="sec.29" target.guid="_431125d0-b9fd-44d7-8377-a8282f3190bd" check="valid">section&#160;29</intref><intref refid="sec.29-ssec.2" target.guid="_7df99c55-fa4b-49f3-bde2-ecf2cf3f9f7c" check="valid">(2)</intref>.</txt></definition><definition id="sch.10-def.affectedtreatmentplant_" guid="_9541b487-0af8-4bd1-8585-c60fc98e64e4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.affectedtreatmentplant" guid="_b8d43999-e4c2-49f7-b7f2-14b2180e2281" type="definition">affected treatment plant</defterm>, for <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, <intref refid="pt.4-div.3" target.guid="_b971f1f5-fbda-4172-92e1-ae150317a83f" check="valid">division&#160;3</intref>, see <intref refid="sec.25" target.guid="_c18c6a3c-9890-476d-b852-161c0bd91a9f" check="valid">section&#160;25</intref>.</txt></definition><definition id="sch.10-def.airconditioningunit_" guid="_40360851-0819-4529-9e12-b88194fec964" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.airconditioningunit" guid="_ebc0c085-7ff2-47d7-abd7-971ac563f6e5" type="definition">air-conditioning unit</defterm> means a unit of plant providing air conditioning and incorporating a cooling tower.</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_85940d78-c125-439b-b663-51b2cccb995c" type="mention">air-conditioning unit</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c9de6d7f-7192-4eea-ab4c-ea3267998626" valid.date="as.made" check="valid">s&#160;21</legref><legref jurisd="QLD" type="subordleg" refid="sec.21-ssec.2" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_05947ec4-ed87-4b7a-a5fa-cca5631d08e9" valid.date="as.made" check="valid">(2)</legref></txt></historynote></definition><definition id="sch.10-def.alternativequalification_" guid="_a9ae3e13-ee31-4381-8877-d11148f6352e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.alternativequalification" guid="_a6535f16-f73b-47a6-b711-990e4cfd7399" type="definition">alternative qualification</defterm> see <intref refid="sec.14" target.guid="_a1698b4d-ced3-4af8-b134-e83758d8bd8a" check="valid">section&#160;14</intref><intref refid="sec.14-ssec.1" target.guid="_c90c767a-55c1-4a49-88c3-ab54405b3d42" check="valid">(1)</intref><intref refid="sec.14-ssec.1-para1.b" target.guid="_3133598e-1524-49f1-9861-27083bf45157" check="valid">(b)</intref>.</txt></definition><definition id="sch.10-def.applicant_" guid="_fd1e5f6b-21a1-408f-8b11-bd5d4c4d3d48" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.applicant" guid="_82454ed4-9eb1-4e05-8c6a-24e46e0d1f66" type="definition">applicant</defterm>, for an application, means the person who made the application. </txt></definition><definition id="sch.10-def.approvedplan_" guid="_fbb388f0-06b8-4caf-9565-09ac4aebc87c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.approvedplan" guid="_99c5400f-3ab2-4ab8-b842-87a40708101c" type="definition">approved plan</defterm>, for work, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.approvedplan-para1.a" guid="_a5428561-675c-42f8-a37e-a6eb88631ae9" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a plan for the work that accompanied the application for, or an application to amend, the permit for the work; or</txt></block></li><li id="sch.10-def.approvedplan-para1.b" guid="_8d5033ed-0bf9-4831-99b7-a76eebfe3f4d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">if the local government or public sector entity issuing or amending the permit changed the plan before issuing or amending the permit—the plan as changed; or</txt></block></li><li id="sch.10-def.approvedplan-para1.c" guid="_e09a5047-b356-4ecf-8098-208b0372d0cf" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">the plan as amended under <intref refid="sec.75" target.guid="_b2564d33-2845-432b-9d2e-b6f3e6db935c" check="valid">section&#160;75</intref>.</txt></block></li></list></definition><definition id="sch.10-def.AS154632017_" guid="_de69cff5-22f5-4f8d-983d-c88eaac09d37" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.AS154632017" guid="_d6e23f79-0f2c-4736-a985-a1ae2a8ac827" type="definition">AS 1546.3:2017</defterm> means the Australian Standard that is currently in force under that designation.</txt></definition><definition id="sch.10_" guid="_8d38b6bb-6a1c-44ca-8636-74edfae43c1c" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.AS154642016" guid="_719b8e3c-fe33-4431-ae22-0ceb3d2b3d0e" type="mention">AS 1546.4:2016</defterm> ...</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_3eab6ebf-15aa-42d2-abc3-735f4d8f2401" type="mention">AS 1546.4:2016</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_83a8f3fe-682b-428f-934e-41067b9f5dcd" valid.date="as.made" check="valid">s&#160;8</legref><legref jurisd="QLD" type="subordleg" refid="sec.8-ssec.1" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_f16d88df-91e9-476e-8cc7-3bccc4b28cb5" valid.date="as.made" check="valid">(1)</legref></txt></historynote></definition><definition id="sch.10-def.AS28702011_" guid="_bb874603-2176-4a5c-a07a-6683f8b1afa9" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.AS28702011" guid="_219b9792-90bc-49ce-aaee-779f2bf85f9e" type="definition">AS 2870—2011</defterm> means the Australian Standard that is currently in force under that designation.</txt></definition><definition id="sch.10-def.ASNZS_" guid="_a9e53e72-5f2e-417f-a900-2f94b627214a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.ASNZS" guid="_25a5bbd4-19f3-474d-9c5f-59f56d214ec4" type="definition">AS/NZS</defterm> means a joint Standards Australia and Standards New Zealand standard.</txt></definition><definition id="sch.10-def.automaticswitchingdevice_" guid="_5cb7d53c-3542-441d-a55c-6958b0a8acf7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.automaticswitchingdevice" guid="_f47caf20-54fd-44ed-b1f5-0778e8ac1d15" type="definition">automatic switching device</defterm> see the Queensland Plumbing and Wastewater Code.</txt></definition><definition id="sch.10-def.backflowpreventionlicensee_" guid="_3377040f-d53b-4b5f-aeac-dde4ea3d60e1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.backflowpreventionlicensee" guid="_5b0639ae-32f5-4cf4-932f-56e8023d313b" type="definition">backflow prevention licensee</defterm>, for maintaining and testing a testable backflow prevention device, means a licensee whose licence authorises the licensee to maintain and test the device.</txt></definition><definition id="sch.10-def.class_" guid="_17746b86-ba8f-4c2c-a325-36ae44280f1d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.class" guid="_b5d2c0d8-4e8d-4155-9aa7-7fa9397db9a3" type="definition">class</defterm>, with a reference to a number, means a building or structure that is classified under the Plumbing Code of Australia as a class of building or structure with that number.</txt></definition><definition id="sch.10-def.combinedsanitarydrain_" guid="_083cf6cc-cc01-4bda-9ea1-dc50b801a8e3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.combinedsanitarydrain" guid="_485754ff-e7e0-42cb-a215-e7f6e7cf7a68" type="definition">combined sanitary drain</defterm> means a sanitary drain for receiving discharges from 2 or more neighbouring premises, other than a sanitary drain owned by the sewerage service provider for the premises.</txt></definition><definition id="sch.10-def.commission_" guid="_c95e5dec-8dcb-4301-8788-26829e494062" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.commission" guid="_116bbd3e-5ccb-4ef4-81c0-0f8d36e076e0" type="definition">commission</defterm>, in relation to plumbing or drainage, means to check—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.commission-para1.a" guid="_a3cb2c10-2f52-49c5-8cc5-3b2b2f154f6c" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the operation of the plumbing or drainage to confirm each component of the plumbing or drainage is functioning correctly; or</txt></block></li><li id="sch.10-def.commission-para1.b" guid="_6511b2ef-7825-4d43-a908-a606eca99081" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the temperature of hot water at an outlet is not more than the maximum temperature allowed for the hot water under the Plumbing Code of Australia.</txt></block></li></list></definition><definition id="sch.10-def.communitytitlesscheme_" guid="_5a897c3f-aecb-4126-acd0-d50a8f93b4e5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.communitytitlesscheme" guid="_d713e6f9-8f67-4c89-a75c-9f5bb0769421" type="definition">community titles scheme</defterm> means a community titles scheme under the <legref jurisd="QLD" type="act" target.doc.id="act-1997-028" target.version.series="64bf56de-be45-4387-8ada-9b4f75f32515" check="valid"><name emphasis="yes">Body Corporate and Community Management Act 1997</name></legref>.</txt></definition><definition id="sch.10-def.compliancestatement_" guid="_4f20f915-6dd6-4a4b-84ee-831ed0939128" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.compliancestatement" guid="_15eb03d8-b398-47b8-800f-9f85089468b5" type="definition">compliance statement</defterm>, for specialist work for which a person has applied for a permit, means a statement, in the approved form and prepared by a suitably qualified person, that the work will comply with the code requirements for the work if it is carried out in compliance with the permit applied for.</txt></definition><definition id="sch.10-def.compliant_" guid="_7ff14a26-3378-485e-8148-ae7a2092fd93" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.compliant" guid="_e88f2175-79f4-4b35-a3eb-3c6d28d67546" type="definition">compliant</defterm>, in relation to plumbing or drainage work, see <legref jurisd="QLD" type="act" refid="sec.69" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_b914028b-9929-46c2-8a6e-14b3d879f0b9" check="valid">section&#160;69</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>.</txt></definition><definition id="sch.10-def.conformityassessmentrequirements_" guid="_65ed392d-9662-4b4f-ae23-e2a83a5a51d0" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.conformityassessmentrequirements" guid="_0d3db017-cb95-4aee-aa56-d8080bb4d950" type="definition">conformity assessment requirements</defterm> means the miscellaneous publication 101:2017 ‘On-site domestic wastewater treatment—Conformity assessment requirements for AS 1546.3 and AS 1546.4’ published by Standards Australia.</txt></definition><definition id="sch.10-def.connectionpoint_" guid="_5d59685c-1d82-4d63-a9bf-b5b61fbe1a97" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.connectionpoint" guid="_0333ae61-2d39-42e4-91c8-7276364067e6" type="definition">connection point</defterm> means a point where—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.connectionpoint-para1.a" guid="_cf188f27-8a67-4847-97f3-f3ddb511aa63" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a service provider’s water supply system connects to a supply pipe; or</txt></block></li><li id="sch.10-def.connectionpoint-para1.b" guid="_bb5643b6-de07-4b22-8974-d15857fb8be0" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a service provider’s sewerage system connects to a sanitary drain or sewer.</txt></block></li></list></definition><definition id="sch.10-def.coolingtower_" guid="_63aae01e-0ff0-4ba7-a4a0-5f4a09cc59c7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.coolingtower" guid="_04b49f36-bce0-4b54-a417-53db4ad54065" type="definition">cooling tower</defterm>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.coolingtower-para1.a" guid="_4ec37078-0cc7-4544-9795-3c1582a7bf26" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">means a device for lowering the temperature of water by evaporative cooling in which atmospheric air passes through sprayed water exchanging heat; and </txt></block></li><li id="sch.10-def.coolingtower-para1.b" guid="_58942b35-c31a-46be-a131-71c03b6bc597" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">includes a device of a type mentioned in <intref refid="sch.10-def.coolingtower-para1.a" target.guid="_4ec37078-0cc7-4544-9795-3c1582a7bf26" check="valid">paragraph&#160;(a)</intref> incorporating a refrigerant or water heat exchanger.</txt></block></li></list><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_a6109e83-f3ae-459b-b885-bf6e02ecec18" type="mention">cooling tower</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c9de6d7f-7192-4eea-ab4c-ea3267998626" valid.date="as.made" check="valid">s&#160;21</legref><legref jurisd="QLD" type="subordleg" refid="sec.21-ssec.2" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_05947ec4-ed87-4b7a-a5fa-cca5631d08e9" valid.date="as.made" check="valid">(2)</legref></txt></historynote></definition><definition id="sch.10-def.covered_" guid="_4c26be95-631c-4338-a576-243ed8e990fd" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.covered" guid="_73118975-4701-4069-bc90-e2991537cd11" type="definition">covered</defterm> includes covered by a floor slab, cladding, lining or soil.</txt></definition><definition id="sch.10-def.coveredworkdeclaration_" guid="_dd3a21e1-7ea7-41cf-95d0-ee0b0bea9011" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.coveredworkdeclaration" guid="_2ec4cd66-3204-4d31-8f18-8aafd4be1abe" type="definition">covered work declaration</defterm> means a declaration, in the approved form, for work that has been covered, stating that the work is compliant.</txt></definition><definition id="sch.10-def.deemedtosatisfysolution_" guid="_de78508a-e289-475a-82f1-a541b4053293" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.deemedtosatisfysolution" guid="_09904e47-a13d-4d2e-98a9-290fc21ccaa1" type="definition">deemed-to-satisfy solution</defterm> means a deemed-to-satisfy solution within the meaning of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.deemedtosatisfysolution-para1.a" guid="_56f0780b-c49d-446d-bb01-501ccb7a57c3" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the Queensland Plumbing and Wastewater Code; or</txt></block></li><li id="sch.10-def.deemedtosatisfysolution-para1.b" guid="_9b7c0d55-e94b-43f0-b8ef-ee27991788c2" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the Plumbing Code of Australia.</txt></block></li></list></definition><definition id="sch.10-def.distributorretailer_" guid="_dc6f964c-3f3b-486a-8f2f-41f490c3e6fc" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.distributorretailer" guid="_06d5de2a-aa4b-4210-8e8e-d22e902440e9" type="definition">distributor-retailer</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" check="valid"><name emphasis="yes">South-East Queensland Water (Distribution and Retail Restructuring) Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="sec.8" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" target.guid="_d9b3c482-0421-4c70-acd4-252d9aec72c9" check="valid">section&#160;8</legref>.</txt></definition><definition id="sch.10-def.doublecheckvalve_" guid="_94d31696-9ec9-47fa-aed8-bef10c166898" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.doublecheckvalve" guid="_00456203-de96-430f-9278-13a6513e8750" type="definition">double check valve</defterm> see the glossary.</txt></definition><definition id="sch.10-def.dualcheckvalvewithatmosphericport_" guid="_ce9e20ce-a0dd-4825-a98a-33d09dca2cf3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.dualcheckvalvewithatmosphericport" guid="_9f29164d-b47b-4861-b74d-7c9a22459948" type="definition">dual check valve with atmospheric port</defterm> see the glossary.</txt></definition><definition id="sch.10-def.dualreticulatedwatersupply_" guid="_96d86d18-7ef6-4c12-b97f-ef77a316eed8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.dualreticulatedwatersupply" guid="_ed3b2c85-8395-4f78-814e-988461e29bf4" type="definition">dual reticulated water supply</defterm> means a water supply that consists of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.dualreticulatedwatersupply-para1.a" guid="_ebfa51b5-f8bf-4a10-8828-f20aa6796a2f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a network utility operator’s supply; and</txt></block></li><li id="sch.10-def.dualreticulatedwatersupply-para1.b" guid="_923150ab-2ea8-4507-bb61-1ac21ff96fda" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">recycled water.</txt></block></li></list></definition><definition id="sch.10-def.eligiblework_" guid="_0cc8a75f-9f11-46c6-8e7e-6cb47b2a82b0" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.eligiblework" guid="_5337996b-2c22-46fb-8136-32db3e035348" type="definition">eligible work</defterm> see <intref refid="sec.70" target.guid="_5a47d2ef-cc7e-48ca-a311-94b89cc5fc10" check="valid">section&#160;70</intref><intref refid="sec.70-para1.c" check="invalid">(c)</intref>.</txt></definition><definition id="sch.10-def.existing_" guid="_45c86ba7-78ff-4133-a22c-751e8d08e2bb" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.existing" guid="_3e8bae91-4ba1-4ffa-b3d0-9e64651e607b" type="definition">existing</defterm>, in relation to a building, means the building has—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.existing-para1.a" guid="_fb3abb77-b75d-47f4-a9f4-9e61a59e7358" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">drainage; and</txt></block></li><li id="sch.10-def.existing-para1.b" guid="_9c059ca5-c719-4236-816b-229881490bfb" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a water supply.</txt></block></li></list></definition><definition id="sch.10-def.existingtreatmentplantapproval_" guid="_ed180819-16b2-49c3-a248-9dc6fec9fb24" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.existingtreatmentplantapproval" guid="_4009ac48-f704-4516-970f-586bae4aa433" type="definition">existing treatment plant approval</defterm>, for <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, <intref refid="pt.4-div.5" target.guid="_8c3941f9-e162-435d-a282-e385d9d9ad88" check="valid">division&#160;5</intref>, see <intref refid="sec.33" target.guid="_602ee7d9-bdf8-45d4-a890-5c5dbc78b351" check="valid">section&#160;33</intref>.</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_ac60003a-8258-41f5-84a5-b6fd32ef4365" type="mention">existing treatment plant approval</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_83a8f3fe-682b-428f-934e-41067b9f5dcd" valid.date="as.made" check="valid">s&#160;8</legref><legref jurisd="QLD" type="subordleg" refid="sec.8-ssec.3" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_b56dc956-24de-464f-9178-78de7a5906d6" valid.date="as.made" check="valid">(3)</legref></txt></historynote></definition><definition id="sch.10-def.fasttrackamendmentapplication_" guid="_1da40ca5-a855-482b-9905-4a9b5249df31" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fasttrackamendmentapplication" guid="_cf9532e9-6a46-40a4-84f3-8c3f60639383" type="definition">fast-track amendment application</defterm> see <intref refid="sec.38" target.guid="_bffb25e9-65c6-4add-980a-427d52c38b01" check="valid">section&#160;38</intref>.</txt></definition><definition id="sch.10-def.fasttrackapplication_" guid="_075acc9f-b289-4293-aa06-6551de3f57f2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fasttrackapplication" guid="_66149d2e-146c-4645-9376-6d28f91b4126" type="definition">fast-track application</defterm> see <intref refid="sec.38" target.guid="_bffb25e9-65c6-4add-980a-427d52c38b01" check="valid">section&#160;38</intref>.</txt></definition><definition id="sch.10-def.fasttrackoptoutdeclaration_" guid="_89d42241-5b94-4869-8b71-448d230c98ba" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fasttrackoptoutdeclaration" guid="_787dd999-ea5f-4d27-a295-04da22479e6e" type="definition">fast-track opt-out declaration</defterm> see <intref refid="sec.40" target.guid="_0c3b5e7a-2518-4fb1-b322-475e2348d3fd" check="valid">section&#160;40</intref><intref refid="sec.40-ssec.1" target.guid="_7e93f368-8535-4cd4-a95e-540427655241" check="valid">(1)</intref>.</txt></definition><definition id="sch.10-def.fasttrackpermitwork_" guid="_d03252ec-2908-452d-802e-d5d4fa237d27" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fasttrackpermitwork" guid="_d72b8c59-308d-4c62-bd4f-1e8070e53474" type="definition">fast-track permit work</defterm> see <intref refid="sec.37" target.guid="_2f9b9a4b-6736-41a0-9a67-1181e22b704c" check="valid">section&#160;37</intref>.</txt></definition><definition id="sch.10-def.fasttrackworkdeclaration_" guid="_405342a8-2ab9-40f9-aeff-1f02df6d0999" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fasttrackworkdeclaration" guid="_a4587b82-e6a4-4c5b-8490-89e08f14ff09" type="definition">fast-track work declaration</defterm> see <intref refid="sec.39" target.guid="_79d99485-b4b0-4c80-afae-6626f9d7e84c" check="valid">section&#160;39</intref><intref refid="sec.39-ssec.1" target.guid="_0952c903-536a-40f8-b978-8105d55d018a" check="valid">(1)</intref>.</txt></definition><definition id="sch.10-def.firehosereel_" guid="_e48dc396-7e5b-4d05-802e-d248bb0813cb" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.firehosereel" guid="_e7155ed5-3bfe-4e67-8792-d9553c0f2c0a" type="definition">fire hose reel</defterm> see the glossary.</txt></definition><definition id="sch.10-def.firehydrant_" guid="_085dcd20-070e-42c7-b3d9-3347afd991ab" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.firehydrant" guid="_aa6a4652-7532-46e2-9ff5-933e5a16c2b3" type="definition">fire hydrant</defterm> see the glossary.</txt></definition><definition id="sch.10-def.fireprotectionoccupationallicence_" guid="_02616744-18cf-440a-8652-bd41a971f1f2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fireprotectionoccupationallicence" guid="_890ba022-8155-4d88-939e-160281b9f315" type="definition">fire protection occupational licence</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref>, <legref jurisd="QLD" type="act" refid="sec.30C" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" target.guid="_11be6ab4-8840-4133-ba5e-db05c136fe2f" check="valid">section&#160;30C</legref>.</txt></definition><definition id="sch.10-def.fireprotectionwork_" guid="_c39c4306-5ce8-4909-b1bd-823ba2aa9f70" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fireprotectionwork" guid="_db1b81f9-f9e0-423b-a717-b969deecfaff" type="definition">fire protection work</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref>, <legref jurisd="QLD" type="act" refid="sch.2" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" target.guid="_db86185d-ccd3-4a3c-afb6-c9fbb29d88a1" check="valid">schedule&#160;2</legref>.</txt></definition><definition id="sch.10-def.fireservice_" guid="_293ddf8e-8a80-4678-b33d-a8084e759f0e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.fireservice" guid="_f10c77e0-d1be-411f-87f9-00f92b17d9b4" type="definition">fire service</defterm> see the glossary.</txt></definition><definition id="sch.10-def.floatvalve_" guid="_0bbafa83-a5ff-43f1-93f3-e69edf6dfa40" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.floatvalve" guid="_7081fa38-e25f-4763-8086-1d04a1261bc7" type="definition">float valve</defterm> see the glossary.</txt></definition><definition id="sch.10-def.greywatercoolingtowertreatmentplant_" guid="_cc87c169-8149-435f-86b9-15f1d98ba284" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.greywatercoolingtowertreatmentplant" guid="_32b06209-b14d-4323-a29f-b0f8933d608f" type="definition">greywater (cooling tower) treatment plant</defterm> see <intref refid="sec.103B" target.guid="_667ec218-2b48-41a3-b165-575acf08e3b9" check="valid">section&#160;103B</intref><intref refid="sec.103B-ssec.1" target.guid="_b82fb2e4-1091-43ab-a83b-9fd4351bdfb3" check="valid">(1)</intref><intref refid="sec.103B-ssec.1-para1.b" target.guid="_45b9a903-8552-42db-80a5-967c91977644" check="valid">(b)</intref>.</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_72fb3b15-aa02-4dfd-9ac0-f21fab0c2651" type="mention">greywater (cooling tower) treatment plant</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c9de6d7f-7192-4eea-ab4c-ea3267998626" valid.date="as.made" check="valid">s&#160;21</legref><legref jurisd="QLD" type="subordleg" refid="sec.21-ssec.2" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_05947ec4-ed87-4b7a-a5fa-cca5631d08e9" valid.date="as.made" check="valid">(2)</legref></txt></historynote></definition><definition id="sch.10-def.groundlevel_" guid="_55a67bad-08e9-4673-ba08-7315af86740b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.groundlevel" guid="_fad59795-d031-427c-ad2f-e91551e22ad3" type="definition">ground level</defterm> see the glossary.</txt></definition><definition id="sch.10-def.holder_" guid="_075995c7-0423-4c87-84d8-ad40b8734f4c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.holder" guid="_84cca44e-96ed-440c-b3f7-49bc1ec4f728" type="definition">holder</defterm>, of a treatment plant approval, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.holder-para1.a" guid="_99d1bbea-6807-482d-a578-7deb81937ef4" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person who has been granted the approval under <intref refid="sec.20" target.guid="_d80d7d5e-1333-4750-926e-1fb439a284ab" check="valid">section&#160;20</intref>; or</txt></block></li><li id="sch.10-def.holder-para1.b" guid="_386604a3-942a-4926-8dcc-c45481a6588d" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a person who is recorded as the holder of the approval under <intref refid="sec.24" target.guid="_9d87ecbf-26c1-47c5-b2bc-1b736254c7b5" check="valid">section&#160;24</intref><intref refid="sec.24-ssec.3" target.guid="_19ce225d-ccca-4af7-b037-0a4f3f567693" check="valid">(3)</intref><intref refid="sec.24-ssec.3-para1.a" target.guid="_9cd4f7ec-57f5-4994-a95e-333c4aa7ebe3" check="valid">(a)</intref>.</txt></block></li></list></definition><definition id="sch.10-def.impervioussurface_" guid="_812824cf-e1ef-4ace-8ba5-a712fce2e06e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.impervioussurface" guid="_e7cb33bb-f8cd-450e-97ba-6790ff93f926" type="definition">impervious surface</defterm> means a surface that is not usually penetrated by water.</txt></definition><definition id="sch.10-def.informationnotice_" guid="_8a77076e-db6a-4617-89b3-cf2c08ce21a1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.informationnotice" guid="_be4870f2-cc9f-4c5d-a18a-616f786e2f94" type="definition">information notice</defterm>, about a decision, means a notice stating—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.informationnotice-para1.a" guid="_a9654a48-6f1e-4a53-aab0-f0d203a19e3f" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the decision; and</txt></block></li><li id="sch.10-def.informationnotice-para1.b" guid="_8ad921a2-4962-43c3-8b83-d400c66e1ef3" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the reasons for the decision; and</txt></block></li><li id="sch.10-def.informationnotice-para1.c" guid="_0908b1a5-b123-4ceb-9eee-3322141facc5" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">that the person to whom the notice is given may appeal to a tribunal against the decision; and</txt><note id="sch.10-def.informationnotice-para1.c-note" guid="_678fff23-1493-49f6-b0ba-8a808d30bd01" type="example"><heading id="sch.10-def.informationnotice-para1.c-note-he" guid="_8228e7d0-f5dd-4fe4-8cad-305ddcb61732">Note—</heading><block><txt break.before="1">The person may start an appeal within the appeal period under the <legref jurisd="QLD" type="act" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" check="valid"><name emphasis="yes">Planning Act 2016</name></legref>. See <legref jurisd="QLD" type="act" refid="sec.229" target.doc.id="act-2016-025" target.version.series="d4a7e9d3-f73d-48a3-9459-9be0b66a1c15" target.guid="_58592a19-df68-44ea-9604-716c37b96f3a" check="valid">section&#160;229</legref> of that Act.</txt></block></note></block></li><li id="sch.10-def.informationnotice-para1.d" guid="_c4f5d7ea-cdce-4f91-aea4-a755ebb56ead" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">how to appeal against the decision.</txt></block></li></list></definition><definition id="sch.10-def.informationrequest_" guid="_a9f3b5ec-ec78-47bf-9a0a-cca05b976ec8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.informationrequest" guid="_ac180f10-026e-4c5e-bb7b-124e9bf3a4b9" type="definition">information request</defterm> see <intref refid="sec.45" target.guid="_ee5c71e8-6333-41bb-9838-2c59c293f839" check="valid">section&#160;45</intref><intref refid="sec.45-ssec.2" target.guid="_2cddd462-ccaa-4e45-b137-a0231d79ad3b" check="valid">(2)</intref>.</txt></definition><definition id="sch.10-def.inspectionopening_" guid="_2f5f225d-f373-43f6-accd-4f4df037732b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.inspectionopening" guid="_3501792e-ac2f-44ca-b433-0f0fe5f26ae0" type="definition">inspection opening</defterm> see the glossary.</txt></definition><definition id="sch.10-def.installation_" guid="_73b16959-cafe-4fb3-a42f-af1c79195af0" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.installation" guid="_a4e7dc0e-11ba-4d51-9b2f-a1ca1c4c05f9" type="definition">installation</defterm> see the glossary.</txt></definition><definition id="sch.10-def.invertlevel_" guid="_255c47b5-c254-4b47-83d5-fe0e5884aa03" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.invertlevel" guid="_75ad067a-ba7f-4b6a-a332-880d953882b3" type="definition">invert level</defterm> see the glossary.</txt></definition><definition id="sch.10-def.irrigation_" guid="_78a9495b-53ab-4d06-87db-c8acc1adcaad" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.irrigation" guid="_1f868b76-d740-4829-899d-900b64609da5" type="definition">irrigation</defterm> see the glossary.</txt></definition><definition id="sch.10-def.isolatingvalve_" guid="_d78dfa01-6d74-4777-bb83-ef7c2323d401" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.isolatingvalve" guid="_31645de3-dd2a-4b55-aae9-0b8ca0444125" type="definition">isolating valve</defterm> see the glossary.</txt></definition><definition id="sch.10-def.jumpervalve_" guid="_b3b54575-c95e-41c1-aff7-117bc58b3b51" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.jumpervalve" guid="_99d5ff67-752a-4c88-a4b2-566c96ac2a9a" type="definition">jumper valve</defterm> see the glossary.</txt></definition><definition id="sch.10-def.localgovernmentapplicationfee_" guid="_6310a4e2-8725-4db1-85a1-279dc23c9115" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.localgovernmentapplicationfee" guid="_6a197667-5e35-4e7f-b9eb-60d3e84b503b" type="definition">local government application fee</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.localgovernmentapplicationfee-para1.a" guid="_9b2ecb68-173b-44e7-91db-5cb03e54a32e" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for an application made to the Brisbane City Council—the fee fixed by the council for the application under the <legref jurisd="QLD" type="act" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid"><name emphasis="yes">City of Brisbane Act 2010</name></legref>, <legref jurisd="QLD" type="act" refid="sec.99" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" target.guid="_d6782b3a-4a6f-468d-bfd1-718f4acb799a" check="valid">section&#160;99</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref> and <legref jurisd="QLD" type="act" check="invalid">(2)</legref><legref jurisd="QLD" type="act" check="invalid">(a)</legref>; or</txt></block></li><li id="sch.10-def.localgovernmentapplicationfee-para1.b" guid="_65790577-9e69-4a5d-8d41-45418d4992e9" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for an application made to another local government—the fee fixed by the local government for the application under the <legref jurisd="QLD" type="act" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid"><name emphasis="yes">Local Government Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="sec.97" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" target.guid="_623edd4d-5c13-4483-b884-4ac0358fcfd8" check="valid">section&#160;97</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref> and <legref jurisd="QLD" type="act" check="invalid">(2)</legref><legref jurisd="QLD" type="act" check="invalid">(a)</legref>.</txt></block></li></list></definition><definition id="sch.10-def.networkutilityoperator_" guid="_21731634-f9fa-4016-8f10-3426194dada4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.networkutilityoperator" guid="_ceab1284-2fbb-48e4-8dab-c43b64b0288e" type="definition">network utility operator</defterm> see the glossary.</txt></definition><definition id="sch.10-def.occupier_" guid="_ed6e1e54-79ec-4f88-afb6-b852c9ed8769" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.occupier" guid="_0eaf6b7a-aa7d-4837-97d9-1b63a39cdd11" type="definition">occupier</defterm>, for <intref refid="pt.6" target.guid="_35027ab7-1839-4560-ab40-318f4738b9bc" check="valid">part&#160;6</intref>, <intref refid="pt.6-div.6" target.guid="_a03d03e9-dbff-4618-9624-9e8add9cba0e" check="valid">division&#160;6</intref>, see <intref refid="sec.93" target.guid="_db8b6597-290e-4ccb-b10b-fd93b9f9c1c0" check="valid">section&#160;93</intref>.</txt></definition><definition id="sch.10-def.onsitesewagework_" guid="_8214174b-60ef-4493-b2eb-3a68a02f4141" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.onsitesewagework" guid="_4b6f8f7f-63aa-46fb-aff5-287cce757ce9" type="definition">on-site sewage work</defterm> means building, installing or altering an on-site sewage facility, including for testing purposes.</txt></definition><definition id="sch.10-def.onsitesewageworkdeclaration_" guid="_121daf87-6b6a-4dd4-9d8b-6c58ceb448db" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.onsitesewageworkdeclaration" guid="_d88de2a5-0eae-475a-ad14-c3039e42872f" type="definition">on-site sewage work declaration</defterm> see <intref refid="sec.69" target.guid="_3d3525f8-e70f-4f6e-80d1-1b9955cf057a" check="valid">section&#160;69</intref><intref refid="sec.69-ssec.2" target.guid="_ed8d9b1c-b488-466a-8513-cc321d522310" check="valid">(2)</intref>.</txt></definition><definition id="sch.10-def.OSTPinstallationwork_" guid="_1fe5a747-6e3a-4cb5-84d4-7dc2d5e194d8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.OSTPinstallationwork" guid="_812417a7-d469-481d-89af-2851da64062a" type="definition">OSTP installation work</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.OSTPinstallationwork-para1.a" guid="_f8965d5b-7215-49fd-8ec0-f36db4e69e62" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">installing a treatment plant the subject of a treatment plant approval; or </txt></block></li><li id="sch.10-def.OSTPinstallationwork-para1.b" guid="_fe969e0f-b497-4617-b73e-6093937fab66" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">establishing a land application area.</txt></block></li></list></definition><definition id="sch.10-def.outlet_" guid="_778f0ec5-78d5-49d8-8926-04ebe14d8cbf" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.outlet" guid="_7767d2d5-030f-4367-9019-8ffb24178afb" type="definition">outlet</defterm> see the glossary.</txt></definition><definition id="sch.10-def.participatinglocalgovernment_" guid="_a44f4454-58fe-4aa4-b545-5a248f475fea" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.participatinglocalgovernment" guid="_57abf938-ae34-4b9e-b26c-be85e764fce5" type="definition">participating local government</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" check="valid"><name emphasis="yes">South-East Queensland Water (Distribution and Retail Restructuring) Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="sec.5" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" target.guid="_ca063e9b-2376-47a6-91e2-93abdb0cdb86" check="valid">section&#160;5</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref>.</txt></definition><definition id="sch.10-def.performancesolution_" guid="_36573453-5b6c-4352-8100-de5b35b754bb" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.performancesolution" guid="_c5252a84-5dc7-4824-87a8-71c9fbce0d98" type="definition">performance solution</defterm> means a performance solution under—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.performancesolution-para1.a" guid="_95c1c0e5-8753-49c2-a68e-a072449ab698" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">the Queensland Plumbing and Wastewater Code; or</txt></block></li><li id="sch.10-def.performancesolution-para1.b" guid="_90a5c966-d397-44dc-aac8-cb5134628475" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">the Plumbing Code of Australia.</txt></block></li></list></definition><definition id="sch.10-def.permitholder_" guid="_87815190-b1a6-4c90-9f0f-f67a7700d3ab" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.permitholder" guid="_8e94733b-fbd5-4ac6-93a0-3732855767fc" type="definition">permit holder</defterm>, for a permit, means the person to whom the permit was issued. </txt></definition><definition id="sch.10-def.pipe_" guid="_6e28ed30-7d06-40f6-9b51-0ecd98f574ec" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.pipe" guid="_d4b6136d-dc14-4d54-aebb-76e97f02efc5" type="definition">pipe</defterm> see the glossary.</txt></definition><definition id="sch.10-def.premises_" guid="_4734f306-6c74-478a-8223-23da97ebed79" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.premises" guid="_b5a65393-013b-45ac-a880-1d8fb4a6ee8c" type="definition">premises</defterm>, in relation to an application, permit, inspection certificate, final inspection certificate or action notice for work, means the premises to which the application, permit, certificate or notice relates.</txt></definition><definition id="sch.10-def.prescribedPCAprovision_" guid="_0aff4f7c-0ffb-439e-9b73-beb5f9bbfa35" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.prescribedPCAprovision" guid="_9b212554-97b7-4545-bf72-bc947e89bd60" type="definition">prescribed PCA provision</defterm> see <intref refid="sec.9" target.guid="_d671ec88-a0a0-4777-aa5b-5437b63fa5df" check="valid">section&#160;9</intref>.</txt></definition><definition id="sch.10-def.prescribedQDCpart_" guid="_75028c87-5f13-42c4-b030-006f7817b276" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.prescribedQDCpart" guid="_24ec3182-8192-4181-b0cc-e5383d4af79c" type="definition">prescribed QDC part</defterm> see <intref refid="sec.10" target.guid="_e9939668-123e-45c0-bc04-047756ff1bcd" check="valid">section&#160;10</intref>.</txt></definition><definition id="sch.10_-oc.2" guid="_4fbdaa6f-0d6c-4b86-a48f-a68c0429b1ca" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.prescribedwatermeter" guid="_f4d1016e-fcb8-422c-8630-fec19fd765f7" type="mention">prescribed water meter</defterm> ...</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_fe4db8ea-ae2d-4e77-857d-30aca35c82d7" type="mention">prescribed water meter</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c9de6d7f-7192-4eea-ab4c-ea3267998626" valid.date="as.made" check="valid">s&#160;21</legref><legref jurisd="QLD" type="subordleg" refid="sec.21-ssec.1" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c2f5730c-b5d8-45cf-9aef-a143d99b2c11" valid.date="as.made" check="valid">(1)</legref></txt></historynote></definition><definition id="sch.10-def.pressuretypevacuumbreaker_" guid="_80b2a908-19f1-4957-a7a9-743f74875680" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.pressuretypevacuumbreaker" guid="_06e5d095-7807-4773-a9df-0a7a97ddff76" type="definition">pressure type vacuum breaker</defterm> see the glossary.</txt></definition><definition id="sch.10-def.previousQueenslandPlumbingandWastewaterCode_" guid="_2bef68e5-342d-497c-9078-e922acac9c7b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.previousQueenslandPlumbingandWastewaterCode" guid="_d2fae453-7e71-488b-b279-c39b02a6ec08" type="definition">previous Queensland Plumbing and Wastewater Code</defterm>, for <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, <intref refid="pt.4-div.5" target.guid="_8c3941f9-e162-435d-a282-e385d9d9ad88" check="valid">division&#160;5</intref>, see <intref refid="sec.33" target.guid="_602ee7d9-bdf8-45d4-a890-5c5dbc78b351" check="valid">section&#160;33</intref>.</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_2b4d0eb4-bcb6-4855-9489-23f826c7e19f" type="mention">previous Queensland Plumbing and Wastewater Code</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_83a8f3fe-682b-428f-934e-41067b9f5dcd" valid.date="as.made" check="valid">s&#160;8</legref><legref jurisd="QLD" type="subordleg" refid="sec.8-ssec.3" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_b56dc956-24de-464f-9178-78de7a5906d6" valid.date="as.made" check="valid">(3)</legref></txt></historynote></definition><definition id="sch.10-def.properlymadeapplication_" guid="_772431b7-39e8-49d3-98e2-2efc61d4f4b4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.properlymadeapplication" guid="_085021f0-1568-406c-8736-98ea833c8f63" type="definition">properly made application</defterm> see <intref refid="sec.44" target.guid="_4528f36f-7bd6-423d-a224-be2fb51c2190" check="valid">section&#160;44</intref><intref refid="sec.44-ssec.4" target.guid="_29031bfa-9cc8-41ef-ba28-a3a0db31e260" check="valid">(4)</intref>.</txt></definition><definition id="sch.10-def.publicoffice_" guid="_99afab5c-65ad-4a50-b34d-b29bf4179721" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.publicoffice" guid="_9f786858-a104-4a00-abed-929fea91fcfc" type="definition">public office</defterm> see—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.publicoffice-para1.a" guid="_33d4fa1c-0b0b-4541-b72f-ca1ef85eca4b" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for the Brisbane City Council—the <legref jurisd="QLD" type="act" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid"><name emphasis="yes">City of Brisbane Act 2010</name></legref>, <legref jurisd="QLD" type="act" refid="sec.241" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" target.guid="_01c7bedc-2d60-45eb-bc86-88446973ec53" check="valid">section&#160;241</legref>; or</txt></block></li><li id="sch.10-def.publicoffice-para1.b" guid="_ee7db241-f72d-46db-a1c5-8b98130d4d73" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for another local government—the <legref jurisd="QLD" type="act" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid"><name emphasis="yes">Local Government Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="sec.261" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" target.guid="_b2d4afa4-3d80-4efd-aaae-338a83c53fac" check="valid">section&#160;261</legref>.</txt></block></li></list></definition><definition id="sch.10-def.recycledwater_" guid="_e0fb4b73-1e33-42dd-8656-45aa565e5241" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.recycledwater" guid="_47610f78-e76c-42ce-acb0-533844188ab5" type="definition">recycled water</defterm> see the glossary.</txt></definition><definition id="sch.10-def.reducedpressurezonedevice_" guid="_a4a32dd7-e2ba-4ce0-8b32-7e56b7beb01e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.reducedpressurezonedevice" guid="_f36a20ee-7f7d-490f-ad8b-716ab40dc4b2" type="definition">reduced pressure zone device</defterm> see the glossary.</txt></definition><definition id="sch.10-def.registeredairgap_" guid="_9a284bbc-28ea-480b-b565-f2201d4ad34c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.registeredairgap" guid="_d70d1c22-ba16-4fdd-93a2-90296b84c09e" type="definition">registered air gap</defterm> means an air gap complying with the requirements for a registered air gap in AS/NZS 3500.1:2003.</txt></definition><definition id="sch.10-def.registeredbreaktank_" guid="_cc97b3f3-3b37-4509-ae5c-7462e6611469" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.registeredbreaktank" guid="_93e30c59-2841-42b5-a6a1-6e01109764cc" type="definition">registered break tank</defterm> means a break tank complying with the requirements for a registered break tank in AS/NZS 3500.1:2003.</txt></definition><definition id="sch.10-def.registeredprofessionalengineer_" guid="_36d4cac0-899c-40a8-9127-545d6ccdbbdf" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.registeredprofessionalengineer" guid="_aa8b1ee8-6f04-4d99-850e-9b23c010ca9f" type="definition">registered professional engineer</defterm> means a registered professional engineer under the <legref jurisd="QLD" type="act" target.doc.id="act-2002-054" target.version.series="b7cf8aa4-8814-465b-ac45-cfbd6a158a10" check="valid"><name emphasis="yes">Professional Engineers Act 2002</name>.</legref></txt></definition><definition id="sch.10-def.relevantwork_" guid="_b5c0b286-ed2d-4703-8bcb-371678037e0e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.relevantwork" guid="_29ee40be-abdb-4e57-97ca-da9c13748d99" type="definition">relevant work</defterm>, for <intref refid="pt.6" target.guid="_35027ab7-1839-4560-ab40-318f4738b9bc" check="valid">part&#160;6</intref>, <intref refid="pt.6-div.4" target.guid="_01030a17-1ac8-4cec-8a9d-03f44240280d" check="valid">division&#160;4</intref>, <intref refid="pt.6-div.4-sdiv.4" target.guid="_6ae2658e-b42c-4c96-b52a-c4b5924ad615" check="valid">subdivision&#160;4</intref>, see <intref refid="sec.78" target.guid="_826c0010-cc77-44d8-9195-d8313bf0d62e" check="valid">section&#160;78</intref>.</txt></definition><definition id="sch.10-def.remotearea_" guid="_a2cc3b30-ffa3-40ff-84e2-a36a87d250ed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.remotearea" guid="_1697dcc2-d089-4b0c-a210-75cd410ea5cd" type="definition">remote area</defterm> means an area within a local government area declared by the local government to be a remote area under <intref refid="sec.71" target.guid="_82725a9f-cca8-45cb-b842-9ba9bbd56650" check="valid">section&#160;71</intref><intref refid="sec.71-ssec.1" target.guid="_6cec384f-4e2d-46ff-a74c-356f2f33bde9" check="valid">(1)</intref><intref refid="sec.71-ssec.1-para1.a" target.guid="_e74544f3-7f5f-4ce8-8b23-07adde6784a0" check="valid">(a)</intref>.</txt></definition><definition id="sch.10-def.remoteareacompliancenotice_" guid="_ec23cb4d-3575-420b-8d51-2c247a7ce0c9" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.remoteareacompliancenotice" guid="_f3d8cab5-b66e-4e15-a97b-cc6b083bda96" type="definition">remote area compliance notice</defterm> see <intref refid="sec.72" target.guid="_fe5e316c-039f-4b4a-9dc4-6a00936f2f68" check="valid">section&#160;72</intref><intref refid="sec.72-ssec.2" target.guid="_432b1dfd-d77f-4994-aec6-531e8cdc8bd9" check="valid">(2)</intref>.</txt></definition><definition id="sch.10-def.requiredstandard_" guid="_5d0b56ea-3988-4d92-9931-7ef1435270e2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.requiredstandard" guid="_8d57098f-06a1-4b0a-bb6a-1f2324df47ba" type="definition">required standard</defterm>, for treating greywater other than kitchen greywater, means the required standard mentioned in <intref refid="sec.103B" target.guid="_667ec218-2b48-41a3-b165-575acf08e3b9" check="valid">section&#160;103B</intref><intref refid="sec.103B-ssec.4" target.guid="_e2352701-4255-41bc-a789-48b9c0d4f966" check="valid">(4)</intref> and to which <intref refid="sch.7A" target.guid="_1d7cb81d-26e8-4473-9fb4-cc45a7bbb52b" check="valid">schedule&#160;7A</intref> relates.</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_5ecf09c5-0638-4579-9a95-66861a2b868c" type="mention">required standard</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" valid.date="as.made" check="valid">2022 SL&#160;No.&#160;171</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_c9de6d7f-7192-4eea-ab4c-ea3267998626" valid.date="as.made" check="valid">s&#160;21</legref><legref jurisd="QLD" type="subordleg" refid="sec.21-ssec.2" target.doc.id="sl-2022-0171" target.version.series="1fdec2bb-a3f6-4467-9f68-0a50efd60c4b" target.guid="_05947ec4-ed87-4b7a-a5fa-cca5631d08e9" valid.date="as.made" check="valid">(2)</legref></txt></historynote></definition><definition id="sch.10-def.sanitaryplumbingwork_" guid="_b8c62449-bca7-4e5b-ab7e-751ecebfef89" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.sanitaryplumbingwork" guid="_fe7bf129-83f1-4cb2-bced-dcbd8258671d" type="definition">sanitary plumbing work</defterm> means installing, altering, extending, disconnecting, taking away, maintaining or testing sanitary plumbing.</txt></definition><definition id="sch.10-def.secondaryonsitesewagetreatmentplant_" guid="_89adb85a-3e3a-4010-80e1-5f1fb9890852" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.secondaryonsitesewagetreatmentplant" guid="_7e0aaa65-70a5-4330-8b53-2b5322b2ccc1" type="definition">secondary on-site sewage treatment plant</defterm> means an on-site sewage treatment plant that produces effluent of a quality equal to or higher than secondary quality effluent.</txt></definition><definition id="sch.10-def.secondaryqualityeffluent_" guid="_1a71271e-7aff-4985-99ec-b9dca8fcc85c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.secondaryqualityeffluent" guid="_af9e960d-719d-4632-b6bb-dd91e622fd2f" type="definition">secondary quality effluent</defterm> see the Queensland Plumbing and Wastewater Code.</txt></definition><definition id="sch.10-def.SEQserviceprovider_" guid="_3e6ea935-92b5-4851-a7a0-9be43e77d333" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.SEQserviceprovider" guid="_471b9040-98c2-4a29-ab92-5237f98e3303" type="definition">SEQ service provider</defterm>, for SEQ water work or SEQ sewerage work, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.SEQserviceprovider-para1.a" guid="_184d7050-6013-49b5-9977-a203617e7e44" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">for work in the Gold Coast City Council’s local government area—the Gold Coast City Council; or</txt></block></li><li id="sch.10-def.SEQserviceprovider-para1.b" guid="_5f6bc7b6-567d-47b1-a70a-5bc438fa7d0c" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">for work in the Logan City Council’s local government area—the Logan City Council; or</txt></block></li><li id="sch.10-def.SEQserviceprovider-para1.c" guid="_124019c1-c98e-46dd-a77f-d029283e0080" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">for work in the Redland City Council’s local government area—the Redland City Council; or</txt></block></li><li id="sch.10-def.SEQserviceprovider-para1.d" guid="_fe20f7f9-df7d-4487-9bd6-03686a12a0de" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">otherwise—the distributor-retailer for the geographic area, under the <legref jurisd="QLD" type="act" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" check="valid"><name emphasis="yes">South-East Queensland Water (Distribution and Retail Restructuring) Act 2009</name></legref>, in which the work has been or is to be carried out.</txt></block></li></list></definition><definition id="sch.10-def.SEQseweragework_" guid="_fb9281ab-dde9-4ddc-b46f-f5b8533f6e20" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.SEQseweragework" guid="_42e18e2d-3956-4cdf-b2e2-dcb0689074a0" type="definition">SEQ sewerage work</defterm> means permit work that involves connecting to, disconnecting from, or altering a connection to, an SEQ service provider’s infrastructure for supplying a sewerage service.</txt></definition><definition id="sch.10-def.SEQwaterwork_" guid="_d634c50f-f5ab-4f20-8cea-b6a71513def5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.SEQwaterwork" guid="_ea579ace-370e-45ae-bc24-99df58d8d4d0" type="definition">SEQ water work</defterm> means permit work that involves connecting to, disconnecting from, or altering a connection to, an SEQ service provider’s water infrastructure.</txt></definition><definition id="sch.10-def.serviceprovider_" guid="_6c7886d7-5239-4dac-be46-ff81662ff857" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.serviceprovider" guid="_a2ac5678-f1ed-41cf-b3a1-cd0deec959ec" type="definition">service provider</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.serviceprovider-para1.a" guid="_038db923-50fc-4b8c-b538-89de6b2cd9cc" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">generally—a sewerage service provider or water service provider; and</txt></block></li><li id="sch.10-def.serviceprovider-para1.b" guid="_2cf69f22-7641-4d36-85e5-36d1b64f2038" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">in relation to work or an application, permit, inspection certificate or final inspection certificate for work—the service provider that supplies a water service or sewerage service for the premises where the work has been, or is to be, carried out.</txt></block></li></list></definition><definition id="sch.10-def.sewerageservice_" guid="_f0ba338f-30ac-423e-92b9-b34dff949cf8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.sewerageservice" guid="_eae2e3ca-10bb-456e-b2cd-dcce0ba6873d" type="definition">sewerage service</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-2008-034" target.version.series="9851f4e7-ed11-449d-9dcc-a56d9299d9cf" check="valid"><name emphasis="yes">Water Supply (Safety and Reliability) Act 2008</name></legref>, <legref jurisd="QLD" type="act" refid="sch.3" target.doc.id="act-2008-034" target.version.series="9851f4e7-ed11-449d-9dcc-a56d9299d9cf" target.guid="_21be43e8-fac0-4bba-965f-efa2f78e3cd0" check="valid">schedule&#160;3</legref>.</txt></definition><definition id="sch.10-def.showcausenotice_" guid="_1bbbd4a0-a1b8-4c66-bd9f-cacd7b8e2c04" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.showcausenotice" guid="_3f119f85-8c82-4606-bf7f-b53636735c93" type="definition">show cause notice</defterm> see <intref refid="sec.28" target.guid="_ca7a628e-67bc-4fbb-af85-64814ae7a5e8" check="valid">section&#160;28</intref><intref refid="sec.28-ssec.2" target.guid="_46a6ec35-a46c-4c46-b6ff-6fad516135dd" check="valid">(2)</intref>.</txt></definition><definition id="sch.10-def.showcauseperiod_" guid="_3cce7774-06b6-4ef0-8c82-38c016cd79f1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.showcauseperiod" guid="_316be0fa-3f61-44c4-8fbb-55d7a85f5aa0" type="definition">show cause period</defterm> see <intref refid="sec.28" target.guid="_ca7a628e-67bc-4fbb-af85-64814ae7a5e8" check="valid">section&#160;28</intref><intref refid="sec.28-ssec.3" target.guid="_56f4bf6e-4f73-4cd3-9fca-7758c16d5129" check="valid">(3)</intref><intref refid="sec.28-ssec.3-para1.d" target.guid="_81a43f21-421c-4f18-8587-03bc6beb3da1" check="valid">(d)</intref>.</txt></definition><definition id="sch.10-def.siteandsoilevaluationreport_" guid="_0dcb45d4-65bf-42c1-8609-4142a300a4bb" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.siteandsoilevaluationreport" guid="_624045b2-9ee0-4671-b261-d420fd96c93c" type="definition">site and soil evaluation report</defterm> see the Queensland Plumbing and Wastewater Code.</txt></definition><definition id="sch.10-def.specialistwork_" guid="_eb8de56e-6b09-494a-a630-ccc7661c1216" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.specialistwork" guid="_3b05f3f1-e86c-4de1-8e0c-b7262bd9760f" type="definition">specialist work</defterm> see <intref refid="sec.45" target.guid="_ee5c71e8-6333-41bb-9838-2c59c293f839" check="valid">section&#160;45</intref><intref refid="sec.45-ssec.1" target.guid="_6c965cc0-499f-4112-af46-d0bbfd178230" check="valid">(1)</intref><intref refid="sec.45-ssec.1-para1.b" target.guid="_1f3187e6-e6d5-4166-b03a-edb7c7374e6f" check="valid">(b)</intref>.</txt></definition><definition id="sch.10-def.structure_" guid="_6ecb6186-a2c5-45f9-bde4-e8ba28dd4c30" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.structure" guid="_2fd8c7f1-1d7d-4f27-aa15-b454f1ef6f2c" type="definition">structure</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref>, <legref jurisd="QLD" type="act" refid="sch.2" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" target.guid="_eb2bfe4c-13cb-46ab-9188-07fe0a4b31c8" check="valid">schedule&#160;2</legref>.</txt></definition><definition id="sch.10-def.suitablyqualifiedperson_" guid="_f85e1512-cb81-46a9-900f-8e6973a8d491" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.suitablyqualifiedperson" guid="_cd83785e-2372-407e-a205-961cc47130ee" type="definition">suitably qualified person</defterm>, for giving a notice, statement or other document to a local government, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.suitablyqualifiedperson-para1.a" guid="_b18ffa22-e9cb-4466-a30d-8f1ab0a0f155" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a person who—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.suitablyqualifiedperson-para1.a-para2.i" guid="_4bff0045-39c6-45e0-bc49-e177228f7ae7" provision.type="other" affected.by.uncommenced="0"><no>(i)</no><block><txt break.before="0">holds a licence to carry out plumbing or drainage work relevant to the work to which the document relates; and</txt></block></li><li id="sch.10-def.suitablyqualifiedperson-para1.a-para2.ii" guid="_b19b48c4-2369-4537-a9f5-84a485222c6d" provision.type="other" affected.by.uncommenced="0"><no>(ii)</no><block><txt break.before="0">has the experience and skills the local government considers appropriate for preparing and giving the document; or</txt></block></li></list></block></li><li id="sch.10-def.suitablyqualifiedperson-para1.b" guid="_59519459-29ee-4487-b1b0-687ce3d6007b" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a person who holds a licence under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name> for building work relevant to the plumbing or drainage work to which the document relates;</legref> or</txt></block></li><li id="sch.10-def.suitablyqualifiedperson-para1.c" guid="_0f43655f-a880-47f9-a008-ea6205412337" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a registered professional engineer for an area of engineering relevant to the work to which the document relates; or</txt></block></li><li id="sch.10-def.suitablyqualifiedperson-para1.d" guid="_b8e28599-35f8-4568-a9e2-44edb054c3c5" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">another person the local government considers is competent to prepare and give the document.</txt></block></li></list></definition><definition id="sch.10-def.supplypipe_" guid="_377890f8-e9ab-423d-b94c-3106c52ed8a2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.supplypipe" guid="_5396d878-e748-41ca-8745-7fd78840cfa3" type="definition">supply pipe</defterm> means a pipe for supplying water within premises.</txt></definition><definition id="sch.10-def.tank_" guid="_411b265c-dcd0-4726-8ba2-bcb44bca6114" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.tank" guid="_8cd9e2df-69ab-4fa0-8300-0efde8c21fce" type="definition">tank</defterm> see the glossary.</txt></definition><definition id="sch.10-def.temperaturecontroldevice_" guid="_4961fd49-7f5c-4482-93ce-145a8e9f04d9" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.temperaturecontroldevice" guid="_6b33dd92-d81f-4b35-9c55-6ffa06b8cddf" type="definition">temperature control device</defterm> see <legref jurisd="QLD" type="act" refid="sec.72" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_f67787a7-9476-4429-baaf-45158d238132" check="valid">section&#160;72</legref><legref jurisd="QLD" type="act" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, definition <defterm guid="_059ee872-684c-4616-ac6e-88cd8dbb75ab" type="mention">temperature control device</defterm>.</txt></definition><definition id="sch.10-def.test_" guid="_597635b9-95a2-4571-a11b-c856f8aa17ba" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.test" guid="_47804316-b169-4910-8d1e-67a760234762" type="definition">test</defterm> see the glossary.</txt></definition><definition id="sch.10-def.testablebackflowpreventiondevice_" guid="_dd918b8e-a1a4-4950-be19-5149b5f58bdd" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.testablebackflowpreventiondevice" guid="_7227bf16-f5e2-4b5f-b164-71c71c1b8757" type="definition">testable backflow prevention device</defterm> means any of the following backflow prevention devices—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.testablebackflowpreventiondevice-para1.a" guid="_237efb31-ae9b-426c-bf8f-edd8608ae2ca" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a double check valve; </txt></block></li><li id="sch.10-def.testablebackflowpreventiondevice-para1.b" guid="_6bf6d43c-3d32-4c24-9b46-3733d677cd41" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">a pressure type vacuum breaker; </txt></block></li><li id="sch.10-def.testablebackflowpreventiondevice-para1.c" guid="_6cba81de-cc65-449c-a3cd-3197e7934815" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">a reduced pressure zone device; </txt></block></li><li id="sch.10-def.testablebackflowpreventiondevice-para1.d" guid="_0160ca7d-e349-4ff5-91bc-546a70a9f7a2" provision.type="other" affected.by.uncommenced="0"><no>(d)</no><block><txt break.before="0">a registered air gap; </txt></block></li><li id="sch.10-def.testablebackflowpreventiondevice-para1.e" guid="_71fd5ba1-6fee-4712-9fa6-0a0b887e27b5" provision.type="other" affected.by.uncommenced="0"><no>(e)</no><block><txt break.before="0">a registered break tank; </txt></block></li><li id="sch.10-def.testablebackflowpreventiondevice-para1.f" guid="_8da4d25e-424c-4d4c-b53f-13c48c8931ba" provision.type="other" affected.by.uncommenced="0"><no>(f)</no><block><txt break.before="0">a testable single check valve.</txt></block></li></list></definition><definition id="sch.10-def.testablesinglecheckvalve_" guid="_a71ba5d2-ea35-4345-8640-ba4e9b93c73d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.testablesinglecheckvalve" guid="_0fc16017-a89b-42d6-ba70-d0f0490a4ed1" type="definition">testable single check valve</defterm> means a device to prevent backflow caused by back pressure that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.testablesinglecheckvalve-para1.a" guid="_4e0d4f42-2012-48d9-9bd8-599133f9d990" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">has a 1-force loaded non-return valve; and</txt></block></li><li id="sch.10-def.testablesinglecheckvalve-para1.b" guid="_2c03b979-dc8d-485a-bdf9-f5ee8aac85ec" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">incorporates specific test points for in-service testing.</txt></block></li></list></definition><definition id="sch.10-def.testingorcommissioningreport_" guid="_205f47c4-cfa2-46fb-8f8c-130cd8400cdf" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.testingorcommissioningreport" guid="_51e0e99c-4227-47f9-908d-441930483476" type="definition">testing or commissioning report</defterm> see <intref refid="sec.77" target.guid="_d8bdf619-d142-4764-8f75-6d2d1de009b3" check="valid">section&#160;77</intref><intref refid="sec.77-ssec.2" target.guid="_048ffa50-b7d6-4618-b5bd-fab029ebc951" check="valid">(2)</intref>.</txt></definition><definition id="sch.10-def.thermostaticmixingvalve_" guid="_7f0a7750-ca85-42c2-b82c-8f4422d3f8b4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.thermostaticmixingvalve" guid="_faffab0a-8663-4b10-8448-8df55145d62d" type="definition">thermostatic mixing valve</defterm> see the glossary.</txt></definition><definition id="sch.10-def.toiletcistern_" guid="_b43f36b5-61e5-4920-9394-65022f816f68" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.toiletcistern" guid="_c5e0ea79-8fa6-4883-b7f5-914ee873d8b0" type="definition">toilet cistern</defterm> has the meaning given to a water closet (WC) cistern in the glossary.</txt></definition><definition id="sch.10-def.tradewaste_" guid="_9a71650c-aef7-4658-8bce-1df6f5e7403d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.tradewaste" guid="_29f506a1-0330-42e1-8b4b-8015effebe9f" type="definition">trade waste</defterm> means water-borne waste from business, manufacturing or trade premises, other than—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.tradewaste-para1.a" guid="_d1961c60-1fe1-4d4c-9290-092b2ebb96c1" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">a prohibited substance under <legref jurisd="QLD" type="act" refid="sec.75" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" target.guid="_dfb4325f-4efa-4fb4-b233-eb43f98175af" check="valid">section&#160;75</legref><legref jurisd="QLD" type="act" check="invalid">(4)</legref> of the <legref jurisd="QLD" type="act" target.doc.id="act-2018-017" target.version.series="cee7b881-5660-41fb-8db7-3e79959b802a" check="valid">Act</legref>, definition <defterm guid="_b68e049b-9053-4d6d-ac21-35d73474a452" type="mention">prohibited substance</defterm>; or</txt></block></li><li id="sch.10-def.tradewaste-para1.b" guid="_03e77ae8-637d-4755-8561-41b74cfcb123" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">human waste; or</txt></block></li><li id="sch.10-def.tradewaste-para1.c" guid="_ad6e5eff-e547-4fb2-9178-be6c5fe4a13f" provision.type="other" affected.by.uncommenced="0"><no>(c)</no><block><txt break.before="0">stormwater.</txt></block></li></list></definition><definition id="sch.10-def.transitionaltreatmentplantapproval_" guid="_11a2f1aa-3627-479d-a1e5-583fc99af543" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.transitionaltreatmentplantapproval" guid="_6f7741e3-8491-4c1f-8a45-90d6bcc3a8cd" type="definition">transitional treatment plant approval</defterm>, for <intref refid="pt.4" target.guid="_d18a94e3-b4a2-4c78-a34a-bc43cd97a67b" check="valid">part&#160;4</intref>, <intref refid="pt.4-div.5" target.guid="_8c3941f9-e162-435d-a282-e385d9d9ad88" check="valid">division&#160;5</intref>, see <intref refid="sec.33" target.guid="_602ee7d9-bdf8-45d4-a890-5c5dbc78b351" check="valid">section&#160;33</intref>.</txt><historynote><txt break.before="1"><b>sch&#160;10</b> def <defterm guid="_9aeaf64e-1f6f-4014-98f9-aec07b4f2c5d" type="mention">transitional treatment plant approval</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" valid.date="as.made" check="valid">2024 SL&#160;No.&#160;43</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_83a8f3fe-682b-428f-934e-41067b9f5dcd" valid.date="as.made" check="valid">s&#160;8</legref><legref jurisd="QLD" type="subordleg" refid="sec.8-ssec.2" target.doc.id="sl-2024-0043" target.version.series="8cbc2f91-c13d-4f27-986d-15de58e46c9c" target.guid="_9d08a6bc-c746-4a93-b322-140ff3e379fc" valid.date="as.made" check="valid">(2)</legref></txt></historynote></definition><definition id="sch.10-def.trap_" guid="_40bb8569-5f66-4e6f-aec7-af9bb88e8e5e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.trap" guid="_0690dbf4-6531-402e-ae1c-fec2454fe2e6" type="definition">trap</defterm> see the glossary.</txt></definition><definition id="sch.10-def.vent_" guid="_ac3a86f2-dc27-45ea-a370-77a1e8df199e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.vent" guid="_164ee8ae-5ad3-42a5-b07d-51f8e51a40c6" type="definition">vent</defterm> see the glossary.</txt></definition><definition id="sch.10-def.vulnerablebodyofwater_" guid="_785346a1-8f70-487b-a9d9-bbb417230304" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.vulnerablebodyofwater" guid="_e0d76abc-d6b2-4284-afa8-907b31b3bfc1" type="definition">vulnerable body of water</defterm> means underground water or a creek, lake, lagoon, marsh, river, stream, swamp or permanent or intermittent watercourse that may be affected by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.10-def.vulnerablebodyofwater-para1.a" guid="_4d703cbb-a309-49e3-b074-23324daaa2ed" provision.type="other" affected.by.uncommenced="0"><no>(a)</no><block><txt break.before="0">greywater from a greywater diversion device or greywater treatment plant; or</txt></block></li><li id="sch.10-def.vulnerablebodyofwater-para1.b" guid="_1989bd88-db2e-489a-9204-693d4053d2b6" provision.type="other" affected.by.uncommenced="0"><no>(b)</no><block><txt break.before="0">effluent from an on-site sewage facility.</txt></block></li></list></definition><definition id="sch.10-def.waterinfrastructure_" guid="_e4071b57-2737-4716-922a-6409b428f932" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.waterinfrastructure" guid="_141b0b98-4e1f-49f8-a4c9-b4ef26dafb8c" type="definition">water infrastructure</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" check="valid"><name emphasis="yes">South-East Queensland Water (Distribution and Retail Restructuring) Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="sec.53BB" target.doc.id="act-2009-046" target.version.series="823a0dc3-6c45-4400-a230-133cee0bae67" target.guid="_1c540bbf-737a-4662-83f0-998fbb5634f5" check="valid">section&#160;53BB</legref><legref jurisd="QLD" type="act" check="invalid">(1)</legref>.</txt></definition><definition id="sch.10-def.waterplumbingwork_" guid="_686e4498-e598-4e79-aceb-ccf6c82c6957" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.waterplumbingwork" guid="_bc3695d8-5e3d-419e-9ce7-6eb046067760" type="definition">water plumbing work</defterm> means installing, altering, extending, disconnecting, taking away, maintaining or testing water plumbing.</txt></definition><definition id="sch.10-def.watersupply_" guid="_4e1b35a9-054c-405d-ae50-dc1eefe1c6dd" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.watersupply" guid="_c6595edb-a6a1-4341-8d1c-84f846d4965f" type="definition">water supply</defterm> see the glossary.</txt></definition><definition id="sch.10-def.work_" guid="_1a15f9c8-e202-4956-bb96-2427aee394d4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.10-def.work" guid="_595062d2-a2b1-4fa3-b07d-0015a7d3126b" type="definition">work</defterm> means plumbing or drainage work.</txt></definition></deflist></block></schedule></schedules></subordleg>