<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE subordleg PUBLIC "-//OQPC//DTD QuILLS Subordinate Legislation//EN" "Subordleg.dtd">
<!--************************************************************************************************************-->
<!--                                              DISCLAIMER                                                    -->
<!---->
<!--Queensland does not accept responsibility for the accuracy or completeness of material on this website      -->
<!--(or any other website referred to on this website) except as set out below. Users should exercise their     -->
<!--own skill and care in the use of the material.                                                              -->
<!---->
<!--No warranty is given that the material located on this site, or on any other site referred to on this site, -->
<!--is free from error or omission. Users should exercise their own skill and care with respect to the use of   -->
<!--the material. Accordingly, the State of Queensland and its servants and agents expressly disclaim liability -->
<!--for any act done or omission made in reliance on any such material and any consequences of any such act or  -->
<!--omission. This notice must not be erased.                                                                   -->
<!---->
<!--************************************************************************************************************-->
<subordleg title="Standard Plumbing and Drainage Regulation 2003" year.citation="2003" no="265" enabling.title="Plumbing and Drainage Act 2002" enabling.acts="act-2002-077" sub.leg.type="reg" amending="none" print.type="reprint" first.valid.date="2019-05-03T00:00:00+10:00" end.valid.date="2019-07-01T00:00:00+10:00" published.date="2003-10-31T00:00:00+10:00" published.how="website" published.ref="pp 691–4" stage.repeal.original.date="2014-09-01T00:00:00+10:00" stage.repeal.postpone.date="2019-08-31T00:00:00+10:00" repeal.date="2019-07-01T00:00:00+10:00" repealed.by="actimplied" repealing.id="act-2018-017" made.by.position="Governor in Council" id="sl-2003-0265" version.desc.id="b93e4ec1-42c2-48b0-a1ac-f645fa70372b" version.series.id="d605e90b-654d-4c7e-94c5-d247f748f1ab" stage.repeal="1" publication.date="2019-05-03" in.force="allinforce"><coverdata id="cd" guid="_4fc9bad7-a3f1-4903-acfc-9e30ea70149d"><subtitle id="cd-sut" guid="_767ea5c5-35e3-4935-87f4-054022638166">Plumbing and Drainage Act 2002</subtitle><statusrecord guid="_96832ee4-c773-4dfb-99a8-615ce59a88f4" id="cd-status"><heading guid="_f27e0a8f-9621-4a19-a3b2-69d539e3ea25" id="cd-status-he">Reprint note</heading><block><txt break.before="1">This is the last reprint before lapse. Lapsed on 1 July 2019 by <legref jurisd="QLD" type="act" target.doc.id="act-2019-017" check="valid" target.version.series="feed8aa7-8753-4fd3-a77c-aee59c53590e">2019 Act&#160;No.&#160;17</legref> <intref refid="sec.158" check="invalid">s&#160;158</intref>.</txt></block></statusrecord></coverdata><wrapper><front id="frnt" guid="_247bccb0-e7ea-49ae-b8a0-1843184ac7a4"><shorttitle id="frnt-st" guid="_48d91737-cbe6-4cf1-98d6-f4cdfae1cb0e">Standard Plumbing and Drainage Regulation 2003</shorttitle></front><body numbering.style="manual"><part id="pt.1" guid="_a82a2b13-4977-4bda-9719-30918079ce86" affected.by.uncommenced="0"><no>Part 1</no><heading id="pt.1-he" guid="_2ec72fd1-4d72-453b-9838-b913fdbe6cd3">Preliminary</heading><division id="pt.1-div.1" guid="_b777662d-22a1-49b7-97ce-efb0f4e6e861" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.1-div.1-he" guid="_867fe042-fd2c-4dea-a756-34bbce3af881">Introduction</heading><clause id="sec.1" guid="_79c1699e-42dd-4fae-b13f-41e04786d177" affected.by.uncommenced="0" spent.amends="0" provision.type="shorttitle"><no>1</no><heading id="sec.1-he" guid="_6c557e03-f1c9-40d6-ae0e-6cd46cce3d9c">Short title</heading><block><txt break.before="1">This regulation may be cited as the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2003-0265" target.version.series="d605e90b-654d-4c7e-94c5-d247f748f1ab" check="valid"><name emphasis="yes">Standard Plumbing and Drainage Regulation 2003</name></legref>.</txt></block></clause><clause id="sec.2" guid="_80d91631-f531-41b5-b189-a513fd7dac50" affected.by.uncommenced="0" spent.amends="0" provision.type="commence"><no>2</no><heading id="sec.2-he" guid="_8116d1ca-e086-4d6c-b0da-307590c830d7">Commencement</heading><block><txt break.before="1">This regulation commences on 1 November 2003.</txt></block></clause></division><division id="pt.1-div.2" guid="_949f3b89-7e42-469e-ba04-010a2f5e2e7f" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.1-div.2-he" guid="_541fd199-1d7e-4584-a18e-2aeb62bec670">Status of regulation</heading><clause id="sec.3" guid="_448fa04f-724a-461b-9049-f7c25fcfc12a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>3</no><heading id="sec.3-he" guid="_d5911fa6-4663-4751-965d-09b239a88760">Status</heading><subclause id="sec.3-ssec.1" guid="_55a3210e-af92-45e7-a796-2779ead4f71a" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This regulation is the Standard Plumbing and Drainage Regulation under <legref jurisd="QLD" type="subordleg" refid="sec.145" target.doc.id="UNKNOWN" check="invalid">section&#160;145</legref><legref jurisd="QLD" type="subordleg" refid="sec.145-ssec.2" target.doc.id="UNKNOWN" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>.</txt></block></subclause><subclause id="sec.3-ssec.2" guid="_d947e2ce-54a3-478b-b65f-7694ccf462da" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">This regulation can not be changed under a local planning instrument or a local law.</txt></block></subclause><subclause id="sec.3-ssec.3" guid="_d738f894-2a89-4189-96d6-bb1040e9eaea" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, this regulation does not stop a local government making a local planning instrument or a local law dealing with matters outside the scope of this regulation that are related to plumbing and drainage work.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;3</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;8</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.3" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;3</legref></txt></historynote></clause></division><division id="pt.1-div.3" guid="_e3e4f58a-bc52-447b-98a3-30c84be1425a" affected.by.uncommenced="0"><no>Division 3</no><heading id="pt.1-div.3-he" guid="_f565b5e0-de9c-4861-b183-9fa073303af0">Interpretation</heading><clause id="sec.4" guid="_5ece959f-6bed-4f64-9f32-41eec0cb0303" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4</no><heading id="sec.4-he" guid="_81f6ed5f-29a8-44e4-ab31-e7bc5bf8d881">Definitions</heading><subclause id="sec.4-ssec.1" guid="_3e83f227-79c6-4ffe-b638-74fa26827655" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The dictionary in <intref refid="sch.6" check="valid" target.guid="_70709acf-780e-4d4c-ac77-9837571ef12e">schedule&#160;6</intref> defines particular words and phrases used in this regulation.</txt></block></subclause><subclause id="sec.4-ssec.2" guid="_40dce8e3-3e7f-455a-bdc5-482c6ce8521d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A word defined in the dictionary as ‘see glossary’ has the meaning given in the glossary.</txt></block></subclause></clause><clause id="sec.4A" guid="_e37cd400-bbc8-474c-afe4-2f9420f17945" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>4A</no><heading id="sec.4A-he" guid="_0b09269d-0ba1-4557-a052-1854dcd3b5d9"><b>What is the <defterm guid="_ac6d736f-06fd-410f-8398-2a661e477a9a" type="mention">Queensland Plumbing and Wastewater Code</defterm> (or <defterm guid="_a1996c50-7c52-4438-9e06-6141efcc2b9f" type="mention">QPW code</defterm></b>)</heading><block><txt break.before="1">The <defterm id="def.QueenslandPlumbingandWastewaterCode" guid="_4972bcff-b85a-4368-8f2d-401b6d85f057" type="definition">Queensland Plumbing and Wastewater Code</defterm> (or <defterm id="def.QPWcode" guid="_81a43114-d97b-4ecf-9b5c-5e9359df5ac6" type="definition">QPW code</defterm>) is the document called the Queensland Plumbing and Wastewater Code, published by the department on 26 October 2017.</txt></block><historynote><txt break.before="1"><b>s&#160;4A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;9</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2010-0099" target.version.series="8dac3270-db81-45d0-8894-47d88f57695a" valid.date="as.made" check="valid">2010 SL&#160;No.&#160;99</legref> <legref jurisd="QLD" type="subordleg" refid="sec.3" target.doc.id="sl-2010-0099" valid.date="as.made" check="invalid">s&#160;3</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;2</legref> <legref jurisd="QLD" type="subordleg" refid="sec.3" target.doc.id="sl-2011-0002" valid.date="as.made" check="invalid">s&#160;3</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0048" target.version.series="74803e6f-a53a-4569-a1a3-f8057b172012" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;48</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2011-0048" valid.date="as.made" check="invalid">s&#160;5</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0011" target.version.series="d846704c-5500-40a2-946b-8dda89396289" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;11</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2013-0011" valid.date="as.made" check="invalid">s&#160;7</legref>; <legref jurisd="QLD" type="act" valid.date="as.made" check="invalid">2017 SL&#160;No.&#160;221</legref> <legref jurisd="QLD" type="act" valid.date="as.made" check="invalid">s&#160;3</legref></txt></historynote></clause><clause id="sec.5" guid="_d8ae99cc-f17d-4a50-bf34-efcec8227ab4" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>5</no><heading id="sec.5-he" guid="_a6e939f4-3e70-4085-ab7b-299790097f95">What are the <defterm guid="_24bebc76-b885-4a70-b079-8b34ef5b7277" type="mention">applied provisions</defterm> and <defterm guid="_a5d6f4dc-48dc-4e5a-9ec7-2c42d4c273cb" type="mention">glossary</defterm></heading><subclause id="sec.5-ssec.1" guid="_5777f2ed-dcaa-4587-9e8a-7e363333d4d0" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">The <defterm id="sec.5-def.appliedprovisions-oc.2" guid="_3fa7276c-5cd5-4629-9fb1-2542cab56be6" type="definition">applied provisions</defterm> are the documents listed in <intref refid="sch.1" check="valid" target.guid="_0f76bb64-c7eb-4f2b-95dd-3bb4a6ba6dd4">schedule&#160;1</intref>.</txt></block></subclause><subclause id="sec.5-ssec.2" guid="_cd6a0a9d-e062-4b25-9b79-83ae6085f7f4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The <defterm id="sec.5-def.glossary-oc.2" guid="_86384f8e-024a-4e83-86cc-501700d05e24" type="definition">glossary</defterm> is AS/NZS 3500.0:2003 (Plumbing and drainage—Glossary of terms).</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;5</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;10</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;21</legref></txt></historynote></clause><clause id="sec.6" guid="_81da635a-5e9b-472e-9606-a815c191355b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6</no><heading id="sec.6-he" guid="_ecc4b3bd-c010-43db-8160-a809189f012c">Interpretation of applied provisions</heading><subclause id="sec.6-ssec.1" guid="_13dff927-9f55-48f4-86cc-6d938410327e" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to a word or phrase if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.6-ssec.1-para1.a" guid="_3ab72010-63e8-4a8d-b37f-15dde8378d9f" provision.type="other"><no>(a)</no><block><txt break.before="0">the word or phrase is defined in the glossary; and</txt></block></li><li id="sec.6-ssec.1-para1.b" guid="_148785d4-70ec-48ae-8e7b-75eef74f878d" provision.type="other"><no>(b)</no><block><txt break.before="0">the word or phrase, or an expression that is in substance equivalent to the word or phrase, is also defined in <intref refid="sch.6" check="valid" target.guid="_70709acf-780e-4d4c-ac77-9837571ef12e">schedule&#160;6</intref>, other than as ‘see glossary’.</txt></block></li></list></block></subclause><subclause id="sec.6-ssec.2" guid="_612f36d9-2dd6-4c3c-afe1-29463b7492f2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For applying the applied provisions under this regulation, a word or phrase to which this section applies is taken to have, to the greatest practicable extent, the meaning given in <intref refid="sch.6" check="valid" target.guid="_70709acf-780e-4d4c-ac77-9837571ef12e">schedule&#160;6</intref>.</txt></block></subclause></clause></division></part><part id="pt.1A" guid="_fd0f8292-3b12-48c3-a008-a7dcbd83b1b6" affected.by.uncommenced="0"><no>Part 1A</no><heading id="pt.1A-he" guid="_1bda0471-3bfe-45e7-a5b2-e8e607117b4c">Prescribed matters for Act</heading><historynote><txt break.before="1"><b>pt hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;11</legref></txt></historynote><clause id="sec.6A" guid="_3b733e99-4c6b-4609-928b-db00cbb087f2" status="repealed" affected.by.uncommenced="0" spent.amends="0" provision.type="other" toc="no"><no>6A</no><heading id="sec.6A-he" guid="_b8d8bdd6-a132-4d58-9025-03037b773ce4">Criteria local government must consider in declaring area to be suitable for greywater use</heading><repealed><repealedtxt/></repealed><historynote><txt break.before="1"><b>s&#160;6A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;11</legref></txt></historynote><historynote><txt break.before="1">om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;4</legref></txt></historynote></clause><clause id="sec.6B" guid="_e2f9560b-e1a8-4153-b636-cef6cf3e46ba" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6B</no><heading id="sec.6B-he" guid="_7fe03c48-ac58-4c9e-807b-d0d5c108be31">Criteria for deciding application for compliance permit for greywater use facility in a sewered area</heading><block><txt break.before="1">The criteria the local government must, under <legref jurisd="QLD" type="subordleg" refid="sec.85B" target.doc.id="UNKNOWN" check="invalid">section&#160;85B</legref><legref jurisd="QLD" type="subordleg" refid="sec.85B-ssec.3" target.doc.id="UNKNOWN" check="invalid">(3)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, consider in deciding an application for a compliance permit for compliance assessable work for, or that includes, a greywater use facility in a sewered area are—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.6B-para1.a" guid="_748ff9f0-b254-4332-ba4c-a4c7b2863e91" provision.type="other"><no>(a)</no><block><txt break.before="0">the proposed use of the greywater from the greywater use facility; and</txt></block></li><li id="sec.6B-para1.b" guid="_b33403d1-02c2-45c8-b39a-6bf57db56300" provision.type="other"><no>(b)</no><block><txt break.before="0">the density of allotments within the relevant locality; and</txt></block></li><li id="sec.6B-para1.c" guid="_bee99b9e-8334-49bd-9145-8533624d51fc" provision.type="other"><no>(c)</no><block><txt break.before="0">the area of land available for dispersal of greywater, after allowing for—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.6B-para1.c-para2.i" guid="_da116292-2aaa-46e4-b3d8-306354db965d" provision.type="other"><no>(i)</no><block><txt break.before="0">setbacks from the boundary of premises at which the facility is proposed to be installed; and</txt></block></li><li id="sec.6B-para1.c-para2.ii" guid="_bbd63eb5-b201-4eb3-9e4c-b21334eccf56" provision.type="other"><no>(ii)</no><block><txt break.before="0">any impervious surfaces; and</txt></block></li></list></block></li><li id="sec.6B-para1.d" guid="_f947abbd-2aa5-4e30-92f0-c23691826c44" provision.type="other"><no>(d)</no><block><txt break.before="0">characteristics of the terrain or soil of the premises and of the relevant locality; and</txt><note id="sec.6B-para1.d-note" guid="_ef98d02e-f402-461e-b459-0f512b177384" type="example"><heading id="sec.6B-para1.d-note-he" guid="_356f42d8-9a4f-4e12-91f3-ceb41c289528">Examples of characteristics of the terrain or soil—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.6B-para1.d-note-para2" guid="_a8af9dec-5677-4360-bc6a-9971fe62291c" provision.type="other"><no>•</no><block><txt break.before="0">shape of the surface of the land</txt></block></li><li id="sec.6B-para1.d-note-para2-oc.2" guid="_09f3113f-2e0e-46b0-b2b1-aa58511786d3" provision.type="other"><no>•</no><block><txt break.before="0">gradient</txt></block></li><li id="sec.6B-para1.d-note-para2-oc.3" guid="_54160a3e-e510-4c4f-9c2a-4e615f1701fe" provision.type="other"><no>•</no><block><txt break.before="0">nature and condition of soil</txt></block></li><li id="sec.6B-para1.d-note-para2-oc.4" guid="_57ee3367-92a6-46ea-9322-c315faed39d3" provision.type="other"><no>•</no><block><txt break.before="0">likely surface run-off</txt></block></li><li id="sec.6B-para1.d-note-para2-oc.5" guid="_2d283831-17dd-4cbd-adef-b543c4fa7eba" provision.type="other"><no>•</no><block><txt break.before="0">lateral and vertical drainage and seepage</txt></block></li><li id="sec.6B-para1.d-note-para2-oc.6" guid="_534dfd56-cb36-45b3-84a1-508dba8ba5fc" provision.type="other"><no>•</no><block><txt break.before="0">a soil type that is unlikely to be able to assimilate biodegradable organic compounds and pathogenic bacteria</txt></block></li></list></block></note></block></li><li id="sec.6B-para1.e" guid="_8e3de521-aeb0-42bc-bb62-9c0a4df0c6bf" provision.type="other"><no>(e)</no><block><txt break.before="0">relevant hydrological and seasonal factors; and</txt><note id="sec.6B-para1.e-note" guid="_c2f93c83-9fc6-4203-bd26-4c280080f46c" type="example"><heading id="sec.6B-para1.e-note-he" guid="_d85be33f-20b5-401a-8748-bd2c48c06c68">Example—</heading><block><txt break.before="1">exposure to sun and wind, rainfall patterns and transpiration from evaporation from vegetation</txt></block></note></block></li><li id="sec.6B-para1.f" guid="_d1572a5f-75f6-434f-b0f5-5391c7f9f9f8" provision.type="other"><no>(f)</no><block><txt break.before="0">whether the application includes the information and documents mentioned in <intref refid="sec.14B" check="valid" target.guid="_d7aa9a24-3881-4db8-bfb2-3ac8f814a7fc">section&#160;14B</intref><intref refid="sec.14B-ssec.3" check="valid" target.guid="_898b59bc-5f7d-41b8-924c-41087d879891">(3)</intref>.</txt></block></li></list></block><historynote><txt break.before="1"><b>s&#160;6B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;11</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;5</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;10</legref></txt></historynote></clause><clause id="sec.6C" guid="_fa9c3b2b-71a5-46f0-9a33-96fcc3fc0e50" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>6C</no><heading id="sec.6C-he" guid="_f4744bbc-59f4-40ba-98cc-e948c7ea9164">Notifiable work—Act, sch, definition <defterm guid="_f9a54ae9-a8ca-47e5-892b-c2da216fb9c2" type="mention">notifiable work</defterm></heading><subclause id="sec.6C-ssec.1" guid="_cb81a5fe-3c1e-490d-b2c5-d3998c9f1fcb" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section prescribes notifiable work for the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, schedule, definition <defterm guid="_fb1dd72f-a116-4f90-a543-f75650bc9774" type="mention">notifiable work</defterm>.</txt></block></subclause><subclause id="sec.6C-ssec.2" guid="_2a290521-d9e3-4d26-af33-ee7b9efec035" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Plumbing and drainage work listed in <intref refid="sch.2" check="valid" target.guid="_97dba53b-829a-4e6e-9e1e-cba0ecf1b997">schedule&#160;2</intref>, <intref refid="sch.2-pt.1" check="valid" target.guid="_bc15edd3-bd20-4048-a681-83a89cd23403">part&#160;1</intref>, item 1 is notifiable work.</txt><note id="sec.6C-ssec.2-note" guid="_3c9011fe-6aac-4cc0-b125-765ebc766646" type="example"><heading id="sec.6C-ssec.2-note-he" guid="_aa156202-fdd2-4216-8e21-a235041db65b">Note—</heading><block><txt break.before="1">Emergency work is listed in <intref refid="sch.2" check="valid" target.guid="_97dba53b-829a-4e6e-9e1e-cba0ecf1b997">schedule&#160;2</intref>, <intref refid="sch.2-pt.1" check="valid" target.guid="_bc15edd3-bd20-4048-a681-83a89cd23403">part&#160;1</intref>, item 1.</txt></block></note></block></subclause><subclause id="sec.6C-ssec.3" guid="_bd998f37-e104-4065-af45-825f49484fdd" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Plumbing and drainage work listed in <intref refid="sch.2" check="valid" target.guid="_97dba53b-829a-4e6e-9e1e-cba0ecf1b997">schedule&#160;2</intref>, <intref refid="sch.2-pt.1" check="valid" target.guid="_bc15edd3-bd20-4048-a681-83a89cd23403">part&#160;1</intref>, items 2 to 16 is notifiable work if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.6C-ssec.3-para1.a" guid="_0a7b51a5-6695-44b3-85c2-6c46609a8f1a" provision.type="other"><no>(a)</no><block><txt break.before="0">the work is not plumbing and drainage work listed in <intref refid="sch.2" check="valid" target.guid="_97dba53b-829a-4e6e-9e1e-cba0ecf1b997">schedule&#160;2</intref>, <intref refid="sch.2-pt.2" check="valid" target.guid="_e70e4cf2-6e37-486f-87ef-eaa06064534c">part&#160;2</intref>, or minor work listed in <intref refid="sch.3" check="valid" target.guid="_4e06519a-670b-4995-9af6-952d6bdc91ea">schedule&#160;3</intref>; and</txt></block></li><li id="sec.6C-ssec.3-para1.b" guid="_034428ec-30e9-4f58-8ffb-4b05022a9314" provision.type="other"><no>(b)</no><block><txt break.before="0">the work is carried out by a relevant licensee for any of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.6C-ssec.3-para1.b-para2.i" guid="_4ec1589a-07db-4742-81a2-705c09e6e713" provision.type="other"><no>(i)</no><block><txt break.before="0">an existing building;</txt></block></li><li id="sec.6C-ssec.3-para1.b-para2.ii" guid="_8a3a8243-b3dc-4825-944c-7d193b5820bb" provision.type="other"><no>(ii)</no><block><txt break.before="0">an extension to an existing building if the existing building is classified under BCA as a class 1 building;</txt></block></li><li id="sec.6C-ssec.3-para1.b-para2.iii" guid="_3a5dea67-838c-4468-a1e9-9250559e16c0" provision.type="other"><no>(iii)</no><block><txt break.before="0">a structure that is for an existing building if the existing building is classified under BCA as a class 1 building.</txt></block></li></list></block></li></list><note id="sec.6C-ssec.3-note" guid="_20e64a8e-d810-40d8-889f-b7df75ce8c32" type="example"><heading id="sec.6C-ssec.3-note-he" guid="_7ac214f2-9859-4863-8904-1f43265a0611">Notes—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.6C-ssec.3-note-para1.1" guid="_5906aac8-6469-4dd2-802d-4f82145350c5" provision.type="other"><no>1</no><block><txt break.before="0">Notice of notifiable work that has been completed must be given within 10 business days after completion of the work. See the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, <legref jurisd="QLD" type="subordleg" refid="sec.87" target.doc.id="UNKNOWN" check="invalid">section&#160;87</legref>.</txt></block></li><li id="sec.6C-ssec.3-note-para1.2" guid="_612d392c-28a2-4e43-aae7-885de5461c30" provision.type="other"><no>2</no><block><txt break.before="0">See also the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, <legref jurisd="QLD" type="subordleg" refid="sec.81A" target.doc.id="UNKNOWN" check="invalid">section&#160;81A</legref> for when notifiable work must be assessed for compliance with this regulation.</txt></block></li></list></block></note></block></subclause><subclause id="sec.6C-ssec.4" guid="_ed2bfed3-5b05-4114-9979-4f25a4f8002b" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.6C-ssec.4-def.existingbuilding_" guid="_dd97b385-6524-4c77-9b53-ad61871380e1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.6C-ssec.4-def.existingbuilding" guid="_ed922ca7-81d4-4ba0-9e13-6a89b26c5afa" type="definition">existing building</defterm> means a building that has drainage and an existing water supply.</txt></definition><definition id="sec.6C-ssec.4-def.relevantlicensee_" guid="_31219067-a856-4dbd-bfee-f7ddc69ef359" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.6C-ssec.4-def.relevantlicensee" guid="_475679fe-3732-4ed8-a22e-1b89b3db840b" type="definition">relevant licensee</defterm>, for plumbing and drainage work, means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.6C-ssec.4-def.relevantlicensee-para1.a" guid="_dd5ef5f9-10bb-40a4-9d41-7a6da40ad2ce" provision.type="other"><no>(a)</no><block><txt break.before="0">a licensee for the work; or</txt></block></li><li id="sec.6C-ssec.4-def.relevantlicensee-para1.b" guid="_55a6b93b-4a7b-446e-bf4a-da602410a299" provision.type="other"><no>(b)</no><block><txt break.before="0">if the work is carried out by more than 1 licensee for the work and all the licensees are employed by the same employer to perform the work—the licensees for the work.</txt></block></li></list></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;6C</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;11</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;4</legref></txt></historynote></clause><clause id="sec.7" guid="_1259ce5a-e775-471a-bfb7-9976e4d96314" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>7</no><heading id="sec.7-he" guid="_d80070fb-7cd6-47dc-bdcf-681b4cc7a5b3">Minor work—Act, sch, definition <defterm guid="_fdbd3cc2-2449-45b7-ba18-6fb98efecccf" type="mention">minor work</defterm></heading><block><txt break.before="1">For the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, schedule, definition <defterm guid="_b60709e7-d418-4d04-b6f9-dea28dc09a35" type="mention">minor work</defterm>, minor work is plumbing or drainage work listed in <intref refid="sch.3" check="valid" target.guid="_4e06519a-670b-4995-9af6-952d6bdc91ea">schedule&#160;3</intref>.</txt></block><historynote><txt break.before="1"><b>s&#160;7</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;12</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;12</legref></txt></historynote></clause><clause id="sec.8" guid="_4835b85e-08f2-420e-9875-fe5d7c0f592d" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>8</no><heading id="sec.8-he" guid="_d9e5638f-92c8-4c30-945e-44cb9778df1a">Unregulated work—Act, sch, definition <defterm guid="_625fcf36-b0f9-4668-8e36-cc1c7bc3eb0a" type="mention">unregulated work</defterm></heading><block><txt break.before="1">For the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, schedule, definition <defterm guid="_b7d9fb04-9b9b-4128-95bf-7ae91f1ae6be" type="mention">unregulated work</defterm>, unregulated work is plumbing or drainage work listed in <intref refid="sch.4" check="valid" target.guid="_05790a71-fd19-484c-a61e-a2e3a97156e9">schedule&#160;4</intref>.</txt></block><historynote><txt break.before="1"><b>s&#160;8</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.13" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;13</legref></txt></historynote></clause></part><part id="pt.2" guid="_b299494b-0b16-4c33-b0af-0588bdcb50d4" affected.by.uncommenced="0"><no>Part 2</no><heading id="pt.2-he" guid="_da5162d6-a791-4814-bdce-eb6fad0adef7">Compliance with particular codes and standards</heading><historynote><txt break.before="1"><b>pt hdg</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.13" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;13</legref></txt></historynote><clause id="sec.8A" guid="_cdffd890-0b3e-4fcd-b028-ea9236cf7e58" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>8A</no><heading id="sec.8A-he" guid="_801a1033-1a67-43b3-be48-0b74a36c5c0a">Compliance with Plumbing Code of Australia</heading><subclause id="sec.8A-ssec.1" guid="_925d8661-1399-42d5-9024-41b23fa5c117" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Plumbing work and drainage work must comply with the PCA, other than part B4–Fire-fighting water services.</txt></block></subclause><subclause id="sec.8A-ssec.2" guid="_aed2a4eb-6229-4cc9-bb60-5fd081ac8bae" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Plumbing work and drainage work complies with the PCA only if the work satisfies the relevant performance requirements under the PCA.</txt></block></subclause><subclause id="sec.8A-ssec.3" guid="_1984557c-3be0-4e22-9bb4-5b41f46012a4" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Compliance with the relevant performance requirements under the PCA can be achieved only by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.8A-ssec.3-para1.a" guid="_9c06eaa7-8ee6-4fcc-9656-df0e86a58eb2" provision.type="other"><no>(a)</no><block><txt break.before="0">complying with the relevant deemed-to-satisfy provisions under the PCA; or</txt></block></li><li id="sec.8A-ssec.3-para1.b" guid="_b83df8d0-0dc8-48af-9817-ef8691e622b9" provision.type="other"><no>(b)</no><block><txt break.before="0">formulating an alternative solution under the PCA that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.8A-ssec.3-para1.b-para2.i" guid="_ae4bea77-8428-43ef-af23-3193eb90da48" provision.type="other"><no>(i)</no><block><txt break.before="0">complies with the performance requirements; and</txt></block></li><li id="sec.8A-ssec.3-para1.b-para2.ii" guid="_42ddcbe4-9f9c-4530-9df5-4f9004af4a8c" provision.type="other"><no>(ii)</no><block><txt break.before="0">is shown to be at least equivalent to the relevant deemed-to-satisfy provisions under the PCA; or</txt></block></li></list></block></li><li id="sec.8A-ssec.3-para1.c" guid="_6e2e631c-9252-459b-8fed-79194dad6b1b" provision.type="other"><no>(c)</no><block><txt break.before="0">a combination of <intref refid="sec.8A-ssec.3-para1.a" check="valid" target.guid="_9c06eaa7-8ee6-4fcc-9656-df0e86a58eb2">paragraphs&#160;(a)</intref> and <intref refid="sec.8A-ssec.3-para1.b" check="valid" target.guid="_b83df8d0-0dc8-48af-9817-ef8691e622b9">(b)</intref>.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;8A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.14" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;14</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2009-0153" valid.date="as.made" check="invalid">s&#160;6</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;22</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2019-0065" target.version.series="4bb90a73-3099-4c5c-ba23-cca4c3ea7886" valid.date="as.made" check="valid">2019 SL&#160;No.&#160;65</legref> <legref jurisd="QLD" type="subordleg" refid="sec.3" target.doc.id="sl-2019-0065" target.version.series="4bb90a73-3099-4c5c-ba23-cca4c3ea7886" valid.date="as.made" check="valid" target.guid="_6b4f4462-a7d7-4e72-ba1d-3489db543e74">s&#160;3</legref></txt></historynote></clause><clause id="sec.8B" guid="_451af886-2838-4ed9-ad1a-08be4cb9fd02" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>8B</no><heading id="sec.8B-he" guid="_6a077f18-6400-49ae-9e0b-040ef6f6879b">Compliance with QPW code</heading><subclause id="sec.8B-ssec.1" guid="_c6f4ba26-d5f4-4e5b-a648-eb03cac72109" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Plumbing work and drainage work must comply with the QPW code.</txt></block></subclause><subclause id="sec.8B-ssec.2" guid="_b0a26243-ad8a-4c21-93c9-885c0a2f8c27" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Plumbing work and drainage work complies with the QPW code only if the work satisfies the relevant performance criteria under the QPW code.</txt></block></subclause><subclause id="sec.8B-ssec.3" guid="_b69c0568-3418-4c21-b701-66ea6db8044c" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Compliance with the relevant performance criteria can be achieved only by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.8B-ssec.3-para1.a" guid="_097fbfef-9299-48a0-a11f-e40dbbe445c2" provision.type="other"><no>(a)</no><block><txt break.before="0">complying with the relevant acceptable solution under the QPW code; or</txt></block></li><li id="sec.8B-ssec.3-para1.b" guid="_7de6fb7d-ef21-4bc8-ad0b-d42c69899f49" provision.type="other"><no>(b)</no><block><txt break.before="0">formulating an alternative solution that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.8B-ssec.3-para1.b-para2.i" guid="_1cfaf54a-4806-43de-82d3-aac89647d864" provision.type="other"><no>(i)</no><block><txt break.before="0">satisfies the performance criteria; and</txt></block></li><li id="sec.8B-ssec.3-para1.b-para2.ii" guid="_d2fe1274-edfc-43b1-bfbc-6dc5eeab968d" provision.type="other"><no>(ii)</no><block><txt break.before="0">is shown to be at least equivalent to the relevant acceptable solution under the QPW code; or</txt></block></li></list></block></li><li id="sec.8B-ssec.3-para1.c" guid="_b78a67f4-e095-455f-b0cd-c055accde8ac" provision.type="other"><no>(c)</no><block><txt break.before="0">a combination of <intref refid="sec.8B-ssec.3-para1.a" check="valid" target.guid="_097fbfef-9299-48a0-a11f-e40dbbe445c2">paragraphs&#160;(a)</intref> and <intref refid="sec.8B-ssec.3-para1.b" check="valid" target.guid="_7de6fb7d-ef21-4bc8-ad0b-d42c69899f49">(b)</intref>.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;8B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;15</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.23" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;23</legref></txt></historynote></clause><clause id="sec.8C" guid="_a8047a14-e06a-4386-aa89-bd3144859e27" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>8C</no><heading id="sec.8C-he" guid="_663cc223-73f3-4868-9183-043750c5d132">Relationship between PCA and QPW code</heading><block><txt break.before="1">If the PCA is inconsistent with the QPW code, the QPW code prevails to the extent of the inconsistency.</txt></block><historynote><txt break.before="1"><b>s&#160;8C</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;15</legref></txt></historynote></clause><clause id="sec.9" guid="_0ed45b09-580d-4a70-87f8-b639793c098e" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>9</no><heading id="sec.9-he" guid="_f8eb9c85-08b1-4238-8f82-a371877eeb9c">Compliance with applied provisions</heading><subclause id="sec.9-ssec.1" guid="_9c472cfc-3d59-4898-ba36-92679a30ef02" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Subject to <intref refid="sec.11" check="valid" target.guid="_1f4d4e9b-058c-4d29-adc2-342472e09bc0">sections&#160;11</intref> and <intref refid="sec.12" check="valid" target.guid="_18ef5b13-77e8-443d-a183-1e9563beca50">12</intref>, plumbing work and drainage work must comply with the applied provisions.</txt></block></subclause><subclause id="sec.9-ssec.2" guid="_74a45b74-b39e-48b7-bf0b-cce07f06f8fa" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Despite any provision contained in the applied provisions limiting the application of the applied provisions to certain premises or installations only, under this regulation the applied provisions apply, to the greatest extent possible, to all premises and installations.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;9</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.16" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;16</legref> <legref jurisd="QLD" type="subordleg" refid="sec.16-ssec.2" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid"/>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;24</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24-ssec.2" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid"/></txt></historynote></clause><clause id="sec.10" guid="_2185d2cf-742e-4705-8c11-612799cd68ef" status="repealed" affected.by.uncommenced="0" spent.amends="0" provision.type="other" toc="no"><no>10</no><heading id="sec.10-he" guid="_2587793f-11a3-4a76-ab90-29c0da5fb423">Minor work and unregulated work</heading><repealed><repealedtxt/></repealed><historynote><txt break.before="1"><b>s&#160;10</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.17" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;17</legref></txt></historynote><historynote><txt break.before="1">om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.25" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;25</legref></txt></historynote></clause><clause id="sec.11" guid="_1f4d4e9b-058c-4d29-adc2-342472e09bc0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>11</no><heading id="sec.11-he" guid="_b75bf93e-3d05-4d2b-977f-e1d86284223a">Limited application of AS/NZS 3500.1:2003</heading><subclause id="sec.11-ssec.1" guid="_0c463be0-1d27-49ab-92b0-b9a4004437b9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to a local government if it is—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.11-ssec.1-para1.a" guid="_8254c951-94ef-4e84-bdba-314fc74e32e3" provision.type="other"><no>(a)</no><block><txt break.before="0">carrying out compliance assessment of a plan for compliance assessable work; or</txt></block></li><li id="sec.11-ssec.1-para1.b" guid="_74f3994d-e7f8-4e55-be63-507d50ea2fa2" provision.type="other"><no>(b)</no><block><txt break.before="0">conducting an assessment, investigation or inspection of compliance assessable work, notifiable work or minor work.</txt></block></li></list></block></subclause><subclause id="sec.11-ssec.2" guid="_09d9544c-928e-46be-90ef-3ad13dc0b6a8" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For the PCA, the local government may apply AS/NZS 3500.1:2003, <intref refid="sec.6" check="valid" target.guid="_81da635a-5e9b-472e-9606-a815c191355b">section&#160;6</intref>, for the assessment of fire services for premises only to the following aspects of the plan or work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.11-ssec.2-para1.a" guid="_420cfc4e-372f-4deb-aecf-b6907885de6b" provision.type="other"><no>(a)</no><block><txt break.before="0">the method of preventing contamination or pollution of the water supply to the premises;</txt><note id="sec.11-ssec.2-para1.a-note" guid="_ac5915ff-b59e-4216-95c5-08f606c110b6" type="example"><heading id="sec.11-ssec.2-para1.a-note-he" guid="_acc5d3b6-5b21-4f17-949d-a2c21b9b99f0">Example—</heading><block><txt break.before="1">providing a testable backflow prevention device upstream of a fire sprinkler system</txt></block></note></block></li><li id="sec.11-ssec.2-para1.b" guid="_02254b80-23bf-4c96-bccd-856e98ddf990" provision.type="other"><no>(b)</no><block><txt break.before="0">the method of jointing, supporting or fixing of the plumbing that is the subject of the plan or work;</txt><note id="sec.11-ssec.2-para1.b-note" guid="_ff141aaf-8d51-4051-a1bc-caa0d098b4ae" type="example"><heading id="sec.11-ssec.2-para1.b-note-he" guid="_7fa05dd9-f5cf-4a52-98fd-27b43770dae1">Example—</heading><block><txt break.before="1">the way a sprinkler head is connected to a pipe in a fire sprinkler system</txt></block></note></block></li><li id="sec.11-ssec.2-para1.c" guid="_9e4fb098-0b75-4198-8157-db8bf2689590" provision.type="other"><no>(c)</no><block><txt break.before="0">the use of the following items in the plumbing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.11-ssec.2-para1.c-para2.i" guid="_2b53c5e1-397e-4825-b33b-1b49e537d21d" provision.type="other"><no>(i)</no><block><txt break.before="0">a certified item;</txt></block></li><li id="sec.11-ssec.2-para1.c-para2.ii" guid="_68b04ea8-3a83-438b-bdd6-0d5e59ca5dd6" provision.type="other"><no>(ii)</no><block><txt break.before="0">an item allowed under <intref refid="sec.31" check="valid" target.guid="_6f438b8f-6792-4db7-8754-37c9a6c18e6b">section&#160;31</intref>.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;11</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.18" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;18</legref> <legref jurisd="QLD" type="subordleg" refid="sec.18-ssec.2" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid"/>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.26" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;26</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.14" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;14</legref></txt></historynote></clause><clause id="sec.12" guid="_18ef5b13-77e8-443d-a183-1e9563beca50" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>12</no><heading id="sec.12-he" guid="_62d532ea-b152-4b06-9dc9-e157418da2fd">Limited application of AS/NZS 3500.4:2003</heading><block><txt break.before="1">For applying AS/NZS 3500.4:2003 under the PCA, the reference in clause 1.9.2(b) of the standard to ‘all other buildings’ is taken to be a reference only to buildings classified under BCA as class 1, 2, 3 or 4 buildings.</txt></block><historynote><txt break.before="1"><b>s&#160;12</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;19</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.27" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;27</legref></txt></historynote></clause><clause id="sec.12A" guid="_2ce22f4a-c02a-47e7-9759-10805780b4bf" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>12A</no><heading id="sec.12A-he" guid="_e7b19947-5666-49a0-9f0c-d3fecf1bf18d">Limited application of some applied provisions</heading><block><txt break.before="1">The applied provisions mentioned in <intref refid="sch.1" check="valid" target.guid="_0f76bb64-c7eb-4f2b-95dd-3bb4a6ba6dd4">schedule&#160;1</intref>, items 1 to 4, apply to plumbing work and drainage work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.12A-para1.a" guid="_68bde466-681e-4e79-bbf2-6e37700f31f9" provision.type="other"><no>(a)</no><block><txt break.before="0">to the extent that the applied provisions refer to plumbing work and drainage work; and</txt></block></li><li id="sec.12A-para1.b" guid="_423bba59-9d2c-4cbb-9f71-c765f51bf7a9" provision.type="other"><no>(b)</no><block><txt break.before="0">at the stage of completion of the work.</txt></block></li></list></block><historynote><txt break.before="1"><b>s&#160;12A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.28" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;28</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0186" target.version.series="75e94809-181b-4e41-a52a-073fe0177a8a" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;186</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2012-0186" valid.date="as.made" check="invalid">s&#160;9</legref></txt></historynote></clause></part><part id="pt.3" guid="_7a1ea24c-8d8e-4046-b714-b561768fc7ee" affected.by.uncommenced="0"><no>Part 3</no><heading id="pt.3-he" guid="_ba0bfa88-e0ec-401d-8981-cfb9f81a4798">Compliance assessment and inspection of notifiable work</heading><historynote><txt break.before="1"><b>pt hdg</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;5</legref></txt></historynote><division id="pt.3-div.1" guid="_0523692b-abc3-4533-aafb-4685d203369f" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.3-div.1-he" guid="_0b95ede9-8ab7-4591-9600-f9a25604a623">Preliminary</heading><clause id="sec.13" guid="_bc96d2ff-75bf-4d92-bcd9-96aec710c6ea" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>13</no><heading id="sec.13-he" guid="_7302cce5-8c44-4180-a69e-fe3eed9e2db8">Application of <intref refid="pt.3" check="valid" target.guid="_7a1ea24c-8d8e-4046-b714-b561768fc7ee">pt&#160;3</intref></heading><subclause id="sec.13-ssec.1" guid="_387f1e91-27a1-458f-bcc0-fd69eaef217c" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This part applies for compliance assessment by a local government of compliance assessable work and plans for the work.</txt></block></subclause><subclause id="sec.13-ssec.2" guid="_99ec3555-1f26-4d0a-9f85-7d62487987bc" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">This part also applies for inspection by a local government of notifiable work.</txt><note id="sec.13-ssec.2-note" guid="_0e6609d4-96b0-499a-ad86-8fe65c7635f9" type="example"><heading id="sec.13-ssec.2-note-he" guid="_8076837a-114c-44fd-8820-eeaf6c156896">Note—</heading><block><txt break.before="1">See the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, <legref jurisd="QLD" type="subordleg" refid="sec.87" target.doc.id="UNKNOWN" check="invalid">sections&#160;87</legref><legref jurisd="QLD" type="subordleg" refid="sec.87-ssec.8" target.doc.id="UNKNOWN" check="invalid">(8)</legref> and <legref jurisd="QLD" type="subordleg" refid="sec.90" target.doc.id="UNKNOWN" check="invalid">90</legref><legref jurisd="QLD" type="subordleg" refid="sec.90-para1.b" target.doc.id="UNKNOWN" check="invalid">(b)</legref>.</txt></block></note></block></subclause><historynote><txt break.before="1"><b>s&#160;13</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.20" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;20</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;15</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;6</legref></txt></historynote></clause></division><division id="pt.3-div.2" guid="_7e905ec8-e5dd-48d0-a62d-e69b8b92e1b3" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.3-div.2-he" guid="_82f37fe6-101a-407d-9d08-e1f48c576296">Assessing plans</heading><clause id="sec.14" guid="_51f30e52-c636-40e2-8da2-a6b8f9a6c11b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>14</no><heading id="sec.14-he" guid="_2a78b164-0710-4409-98e3-a9cea25c2ca9">General requirements for plans the subject of a compliance request</heading><subclause id="sec.14-ssec.1" guid="_40cf7673-ddb1-4085-92b6-2696d0b75693" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section imposes requirements for a plan the subject of a compliance request.</txt></block></subclause><subclause id="sec.14-ssec.2" guid="_e6f3bf02-8d0d-4e27-b6f4-006145517488" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must be drawn to scale and show sufficient dimensions and information to allow the local government to assess the proposed plumbing and drainage.</txt></block></subclause><subclause id="sec.14-ssec.3" guid="_0336a9b8-b80a-4ee9-b32a-60f92ac867ef" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Without limiting <intref refid="sec.14-ssec.2" check="valid" target.guid="_e6f3bf02-8d0d-4e27-b6f4-006145517488">subsection&#160;(2)</intref>, the plan must include, or be accompanied by, the documents or information mentioned in—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.3-para1.a" guid="_f37d9929-c610-432c-801d-73729e6ea623" provision.type="other"><no>(a)</no><block><txt break.before="0">any of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.3-para1.a-para2.i" guid="_0a16d422-b9c1-459c-94a6-5dde80889db8" provision.type="other"><no>(i)</no><block><txt break.before="0">for compliance assessable work—<intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">section&#160;14A</intref>;</txt></block></li><li id="sec.14-ssec.3-para1.a-para2.ii" guid="_ffb4d463-82a9-4111-ad59-9f0f994e46b5" provision.type="other"><no>(ii)</no><block><txt break.before="0">for compliance assessable work for, or that includes, a greywater use facility in a sewered area—<intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">sections&#160;14A</intref> and <intref refid="sec.14B" check="valid" target.guid="_d7aa9a24-3881-4db8-bfb2-3ac8f814a7fc">14B</intref>;</txt></block></li><li id="sec.14-ssec.3-para1.a-para2.iii" guid="_0207963a-486b-46da-8f62-d972c98e6b23" provision.type="other"><no>(iii)</no><block><txt break.before="0">for compliance assessable work for, or that includes, a greywater use facility not in a sewered area—<intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">sections&#160;14A</intref> and <intref refid="sec.14C" check="valid" target.guid="_6bcae4fd-863a-4622-92c2-90fddd1ee070">14C</intref>;</txt></block></li><li id="sec.14-ssec.3-para1.a-para2.iv" guid="_449292c5-772a-4fad-914d-91251ead3e80" provision.type="other"><no>(iv)</no><block><txt break.before="0">for compliance assessable work for an on-site sewerage facility—<intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">sections&#160;14A</intref> and <intref refid="sec.14D" check="valid" target.guid="_119a8124-d2ef-48db-90f5-6d7da0febc0a">14D</intref>; and</txt></block></li></list></block></li><li id="sec.14-ssec.3-para1.b" guid="_86df9776-5ed1-4ca1-ac6d-de3dafc66800" provision.type="other"><no>(b)</no><block><txt break.before="0">if <intref refid="sec.16" check="valid" target.guid="_69f0c0f3-e4db-41e9-8b30-56fd2774898b">section&#160;16</intref><intref refid="sec.16-ssec.1" check="valid" target.guid="_eaad0a0d-94b4-43d3-8cff-4082096130d1">(1)</intref><intref refid="sec.16-ssec.1-para1.b" check="valid" target.guid="_cc96a2e0-451c-44b2-a9f2-921629d50c38">(b)</intref> applies—<intref refid="sec.16" check="valid" target.guid="_69f0c0f3-e4db-41e9-8b30-56fd2774898b">section&#160;16</intref><intref refid="sec.16-ssec.2" check="valid" target.guid="_19730a6b-14b9-4d37-8a48-ac4f17199a11">(2)</intref>.</txt></block></li></list></block></subclause><subclause id="sec.14-ssec.4" guid="_b072445d-64bb-4994-a92f-eeddb74e9c2e" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The plan must show—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.4-para1.a" guid="_fa6296fb-d457-4bcb-9c7d-35cb7d48e126" provision.type="other"><no>(a)</no><block><txt break.before="0">the name of the person who designed the plumbing and drainage; and</txt></block></li><li id="sec.14-ssec.4-para1.b" guid="_7865066d-2fa3-459f-b2c4-9ab9e1ab4deb" provision.type="other"><no>(b)</no><block><txt break.before="0">for the person mentioned in <intref refid="sec.14-ssec.4-para1.a" check="valid" target.guid="_fa6296fb-d457-4bcb-9c7d-35cb7d48e126">paragraph&#160;(a)</intref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.4-para1.b-para2.i" guid="_4cf6d38f-3a99-4d92-9d4a-eeab2784bfa0" provision.type="other"><no>(i)</no><block><txt break.before="0">if the person is registered or licensed under a law applying in the State to practise in the aspect of the work—the person’s registration or licence number; or</txt></block></li><li id="sec.14-ssec.4-para1.b-para2.ii" guid="_bcc1567b-100d-4ec5-9cc9-4897c47bf7c8" provision.type="other"><no>(ii)</no><block><txt break.before="0">if the work is on-site sewerage work and <intref refid="sec.14-ssec.4-para1.b-para2.i" check="valid" target.guid="_4cf6d38f-3a99-4d92-9d4a-eeab2784bfa0">subparagraph&#160;(i)</intref> does not apply—sufficient information about the person’s qualifications and experience to enable the local government to decide whether the person is qualified to design the on-site sewerage facility.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.14-ssec.5" guid="_63c2edc9-693a-4b92-9694-0e583702f5c4" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">The information mentioned in <intref refid="sec.14-ssec.4" check="valid" target.guid="_b072445d-64bb-4994-a92f-eeddb74e9c2e">subsection&#160;(4)</intref> must be shown—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14-ssec.5-para1.a" guid="_a30e29c3-a69d-42f8-8176-3e27d2d49f82" provision.type="other"><no>(a)</no><block><txt break.before="0">on each page of the plan; or</txt></block></li><li id="sec.14-ssec.5-para1.b" guid="_2a8386cc-7d3b-445b-a5ae-21e461fabbe7" provision.type="other"><no>(b)</no><block><txt break.before="0">on a cover sheet at the front of the plan that references each page of the plan.</txt></block></li></list></block></subclause><subclause id="sec.14-ssec.6" guid="_58e5ef01-d0ff-4721-9692-4a0080e5167c" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">The person making the request must, if required by the local government, give the local government a reasonable number of copies of the plan.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;14</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;21</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.16" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;16</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;7</legref></txt></historynote></clause><clause id="sec.14A" guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>14A</no><heading id="sec.14A-he" guid="_58a687a6-1893-4f3d-8395-b50d2bbf4cc2">Additional requirements for plans for compliance assessable work</heading><subclause id="sec.14A-ssec.1" guid="_0c8d782f-febc-4308-b4c5-ae0ad9a033f6" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.14" check="valid" target.guid="_51f30e52-c636-40e2-8da2-a6b8f9a6c11b">section&#160;14</intref>, to a compliance request for compliance assessable work.</txt></block></subclause><subclause id="sec.14A-ssec.2" guid="_5c0faed9-b7c6-43ef-9892-d04ec07abd3c" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">There must be a site plan of the premises on which the compliance assessable work is to be performed showing each of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14A-ssec.2-para1.a" guid="_24b37ca3-76d7-45c2-99ba-1bd37c5376bd" provision.type="other"><no>(a)</no><block><txt break.before="0">the location of proposed or existing buildings or structures on the premises;</txt></block></li><li id="sec.14A-ssec.2-para1.b" guid="_16c1fb13-4913-45f1-8298-667c811fe2cd" provision.type="other"><no>(b)</no><block><txt break.before="0">the ground levels and drainage invert levels, referenced to AHD or appropriately reduced levels, to indicate whether sanitary drains can gravity feed to the connection point for the sewer or on-site sewage treatment plant;</txt></block></li><li id="sec.14A-ssec.2-para1.c" guid="_c292953b-e0bc-4d4f-9fef-4759778c610b" provision.type="other"><no>(c)</no><block><txt break.before="0">the location of each connection point to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14A-ssec.2-para1.c-para2.i" guid="_d01bd5a4-ff97-4759-aea1-76835a710ee0" provision.type="other"><no>(i)</no><block><txt break.before="0">a service provider’s water supply or sewerage system; or</txt></block></li><li id="sec.14A-ssec.2-para1.c-para2.ii" guid="_017b9814-cca6-405a-af6b-a766f580484f" provision.type="other"><no>(ii)</no><block><txt break.before="0">an on-site sewage treatment plant; or</txt></block></li><li id="sec.14A-ssec.2-para1.c-para2.iii" guid="_43b7eb1b-717e-44c3-b536-fff5587a6887" provision.type="other"><no>(iii)</no><block><txt break.before="0">a greywater treatment plant;</txt></block></li></list></block></li><li id="sec.14A-ssec.2-para1.d" guid="_96514f1b-7d87-4dc6-b544-70e250b53ad9" provision.type="other"><no>(d)</no><block><txt break.before="0">if the work is to be performed on any of the following—the approximate location on the premises of the below ground water supply pipes and sanitary drainage pipes for any plumbing and drainage for the work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14A-ssec.2-para1.d-para2.i" guid="_767fef91-c20f-45b6-b66d-f6298cc0a08d" provision.type="other"><no>(i)</no><block><txt break.before="0">a building classified under BCA as a class 1 building, on a lot that is not part of a community titles scheme;</txt></block></li><li id="sec.14A-ssec.2-para1.d-para2.ii" guid="_012a16e5-d09d-43da-98f8-0d7d569f69b8" provision.type="other"><no>(ii)</no><block><txt break.before="0">a building classified under BCA as a class 10 building;</txt></block></li></list></block></li><li id="sec.14A-ssec.2-para1.e" guid="_b3599eac-40b8-416b-9adb-1c8ff66d4fd3" provision.type="other"><no>(e)</no><block><txt break.before="0">if the work is to be performed on a building other than a building mentioned in <intref refid="sec.14A-ssec.2-para1.d" check="valid" target.guid="_96514f1b-7d87-4dc6-b544-70e250b53ad9">paragraph&#160;(d)</intref>—the proposed location and details of installation for any plumbing and drainage for the work.</txt></block></li></list></block></subclause><subclause id="sec.14A-ssec.3" guid="_f69bd86d-4597-4f84-ab20-62d52d3b361d" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the compliance assessable work is work to be performed on a building mentioned in <intref refid="sec.14A-ssec.2" check="valid" target.guid="_5c0faed9-b7c6-43ef-9892-d04ec07abd3c">subsection&#160;(2)</intref><intref refid="sec.14A-ssec.2-para1.d" check="valid" target.guid="_96514f1b-7d87-4dc6-b544-70e250b53ad9">(d)</intref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14A-ssec.3-para1.a" guid="_b8d03816-f43e-4ff4-87c5-1a00b754a9d5" provision.type="other"><no>(a)</no><block><txt break.before="0">there must be—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14A-ssec.3-para1.a-para2.i" guid="_84fd88df-0d27-480a-8696-a53e30dcdd85" provision.type="other"><no>(i)</no><block><txt break.before="0">a floor plan of the building; and</txt></block></li><li id="sec.14A-ssec.3-para1.a-para2.ii" guid="_55544138-5dd5-4882-988d-470840e22b44" provision.type="other"><no>(ii)</no><block><txt break.before="0">a plan showing the elevations of the building; and</txt></block></li></list></block></li><li id="sec.14A-ssec.3-para1.b" guid="_61780909-bad8-4b4d-acc3-002e214afd67" provision.type="other"><no>(b)</no><block><txt break.before="0">the location and details of the building’s fixtures must be shown on each of the plans mentioned in <intref refid="sec.14A-ssec.3-para1.a" check="valid" target.guid="_b8d03816-f43e-4ff4-87c5-1a00b754a9d5">paragraph&#160;(a)</intref>.</txt></block></li></list></block></subclause><subclause id="sec.14A-ssec.4" guid="_a408ba36-5cc3-408a-8a1c-6b1c4113e077" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the compliance assessable work is to be performed on a building other than a building mentioned in <intref refid="sec.14A-ssec.2" check="valid" target.guid="_5c0faed9-b7c6-43ef-9892-d04ec07abd3c">subsection&#160;(2)</intref><intref refid="sec.14A-ssec.2-para1.d" check="valid" target.guid="_96514f1b-7d87-4dc6-b544-70e250b53ad9">(d)</intref>, there must be a floor plan of the building showing the approximate location on the premises of each meter, and details of the specifications of each meter, for measuring the supply of water to any part of the premises.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;14A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;22</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;6</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.17" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;17</legref></txt></historynote></clause><clause id="sec.14B" guid="_d7aa9a24-3881-4db8-bfb2-3ac8f814a7fc" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>14B</no><heading id="sec.14B-he" guid="_3ab4682d-c042-4075-a9fa-4ddb040514f0">Additional requirements for plans for greywater use facilities in a sewered area</heading><subclause id="sec.14B-ssec.1" guid="_58833bfb-5373-49cb-88d1-3dc25cee24cd" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.14" check="valid" target.guid="_51f30e52-c636-40e2-8da2-a6b8f9a6c11b">sections&#160;14</intref> and <intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">14A</intref>, to a compliance request for compliance assessable work for, or that includes, a greywater use facility in a sewered area.</txt></block></subclause><subclause id="sec.14B-ssec.2" guid="_ccef588c-855e-47ca-b47d-949e6cc05504" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">There must be a site plan of the premises on which the work is to be performed showing each of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.2-para1.a" guid="_51ba2ede-bbc0-4003-92c0-01c41b4cb4ea" provision.type="other"><no>(a)</no><block><txt break.before="0">if the facility includes a greywater application area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.2-para1.a-para2.i" guid="_028c6859-af0e-4a82-9188-e88450c99c77" provision.type="other"><no>(i)</no><block><txt break.before="0">the location of the area; and</txt></block></li><li id="sec.14B-ssec.2-para1.a-para2.ii" guid="_e35f2615-0707-4d66-9d82-7cd24ff5ad8f" provision.type="other"><no>(ii)</no><block><txt break.before="0">the distances from the area to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.2-para1.a-para2.ii-para3.A" guid="_9722f5da-107f-4804-a32b-7d6433adec66" provision.type="other"><no>(A)</no><block><txt break.before="0">the boundary of the premises;</txt></block></li><li id="sec.14B-ssec.2-para1.a-para2.ii-para3.B" guid="_d5a18b32-1976-4867-bc17-d3f1743f8f1c" provision.type="other"><no>(B)</no><block><txt break.before="0">proposed or existing buildings or structures on the premises;</txt></block></li><li id="sec.14B-ssec.2-para1.a-para2.ii-para3.C" guid="_749cf436-08e1-45c8-9e50-7eb192685e44" provision.type="other"><no>(C)</no><block><txt break.before="0">any impervious surfaces on the premises, including, for example, paths for pedestrians and paved areas;</txt></block></li></list></block></li></list></block></li><li id="sec.14B-ssec.2-para1.b" guid="_c45908af-30c3-44ae-8e5d-b600bc1c96b6" provision.type="other"><no>(b)</no><block><txt break.before="0">the connection from the greywater treatment plant or greywater diversion device to sanitary drainage.</txt></block></li></list></block></subclause><subclause id="sec.14B-ssec.3" guid="_898b59bc-5f7d-41b8-924c-41087d879891" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Each of the following must be included—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.3-para1.a" guid="_c06e64b6-1ddd-4dab-bd49-cfdda68d339a" provision.type="other"><no>(a)</no><block><txt break.before="0">a document showing that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.3-para1.a-para2.i" guid="_cf754b55-1dfb-41ef-aee2-c40664ac2d9f" provision.type="other"><no>(i)</no><block><txt break.before="0">the facility’s greywater treatment plant has a chief executive approval; or</txt></block></li><li id="sec.14B-ssec.3-para1.a-para2.ii" guid="_ab721101-a76c-4363-b353-3d321014d2b2" provision.type="other"><no>(ii)</no><block><txt break.before="0">the facility’s greywater diversion device has plumbing code authorisation and certification;</txt></block></li></list></block></li><li id="sec.14B-ssec.3-para1.b" guid="_feb3205b-75cc-495a-ade3-fe8ab6de54a6" provision.type="other"><no>(b)</no><block><txt break.before="0">sufficient information to enable the local government to decide whether any ponding or run-off of the greywater discharged could cause—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.3-para1.b-para2.i" guid="_4518c250-a2ed-495e-861f-3dc5ab0bf9a3" provision.type="other"><no>(i)</no><block><txt break.before="0">a danger or health risk to any one; or</txt><note id="sec.14B-ssec.3-para1.b-para2.i-note" guid="_746501e7-4f71-45f7-bbff-2983e007f926" type="example"><heading id="sec.14B-ssec.3-para1.b-para2.i-note-he" guid="_b7f17d9d-8df2-4916-be36-22668ffeb0f8">Example of a thing that may cause a health risk—</heading><block><txt break.before="1">insufficient irrigation area to ensure long-term performance of a greywater use facility</txt></block></note></block></li><li id="sec.14B-ssec.3-para1.b-para2.ii" guid="_065e3f6d-6fbe-4c91-a953-387d9d455d2e" provision.type="other"><no>(ii)</no><block><txt break.before="0">odour that unreasonably interferes, or is likely to unreasonably interfere, with the use or enjoyment of any other premises;</txt></block></li></list></block></li><li id="sec.14B-ssec.3-para1.c" guid="_c64e8073-5f24-411b-b88a-f44a340bf865" provision.type="other"><no>(c)</no><block><txt break.before="0">if the work is for testing purposes—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14B-ssec.3-para1.c-para2.i" guid="_f6ed1607-4646-4b32-9bc6-d1606219dd0b" provision.type="other"><no>(i)</no><block><txt break.before="0">details of the testing approval for the proposed greywater use facility, including any conditions the chief executive imposes on the approval; and</txt></block></li><li id="sec.14B-ssec.3-para1.c-para2.ii" guid="_47631480-2f90-4dd6-8e25-2b2af65d669b" provision.type="other"><no>(ii)</no><block><txt break.before="0">any other information that the local government requires in relation to the testing;</txt></block></li></list></block></li><li id="sec.14B-ssec.3-para1.d" guid="_2057fff0-d8af-4a7a-96b0-7be7e8a11963" provision.type="other"><no>(d)</no><block><txt break.before="0">details of the proposed use of the greywater from the greywater use facility.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;14B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;22</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;7</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.18" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;18</legref></txt></historynote></clause><clause id="sec.14C" guid="_6bcae4fd-863a-4622-92c2-90fddd1ee070" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>14C</no><heading id="sec.14C-he" guid="_382fc4ab-0242-483b-b56e-55cc2f37c5fd">Additional requirements for plans for greywater use facilities not in a sewered area</heading><subclause id="sec.14C-ssec.1" guid="_5a9ad0f1-bf50-42c3-b1e4-76ba5b23e146" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.14" check="valid" target.guid="_51f30e52-c636-40e2-8da2-a6b8f9a6c11b">sections&#160;14</intref> and <intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">14A</intref>, to a compliance request for compliance assessable work for, or that includes, a greywater use facility not in a sewered area.</txt></block></subclause><subclause id="sec.14C-ssec.2" guid="_3462172d-4e77-41a9-bacd-fa6b2f33dd6e" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">There must be a site plan of the premises on which the work is to be performed showing each of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.2-para1.a" guid="_63a69af9-8d43-4d40-a6c5-0e62a4495bd7" provision.type="other"><no>(a)</no><block><txt break.before="0">the location of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.2-para1.a-para2.i" guid="_877723d9-8cd9-4b0f-95a6-7df3b3cef4d3" provision.type="other"><no>(i)</no><block><txt break.before="0">if the facility includes a greywater application area—the location of the area;</txt></block></li><li id="sec.14C-ssec.2-para1.a-para2.ii" guid="_04dc622c-d511-4a47-a2dd-a3f66a07855b" provision.type="other"><no>(ii)</no><block><txt break.before="0">the proposed greywater treatment plant or greywater diversion device;</txt></block></li><li id="sec.14C-ssec.2-para1.a-para2.iii" guid="_fe971236-5c22-402b-a2eb-a8bcb8efe538" provision.type="other"><no>(iii)</no><block><txt break.before="0">any proposed or existing on-site sewage treatment plant;</txt></block></li><li id="sec.14C-ssec.2-para1.a-para2.iv" guid="_9a015045-3eeb-4d5d-ae5b-472e7982b631" provision.type="other"><no>(iv)</no><block><txt break.before="0">any proposed or existing on-site sewerage application area, including the layout of drainage for, and the proposed method of applying greywater to, the area;</txt></block></li></list></block></li><li id="sec.14C-ssec.2-para1.b" guid="_51cbea98-7f0d-46c3-b671-1a58effd9fd0" provision.type="other"><no>(b)</no><block><txt break.before="0">if the facility includes a greywater application area—the distances from the area to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.2-para1.b-para2.i" guid="_fa5d01f1-4af3-40aa-9256-5df6f6a4c14c" provision.type="other"><no>(i)</no><block><txt break.before="0">the boundary of the premises;</txt></block></li><li id="sec.14C-ssec.2-para1.b-para2.ii" guid="_cab54732-3c35-4c8b-aeed-7c7bbaa94bdb" provision.type="other"><no>(ii)</no><block><txt break.before="0">proposed or existing buildings or structures on the premises;</txt></block></li><li id="sec.14C-ssec.2-para1.b-para2.iii" guid="_d839f32d-8bfe-494b-a009-6c9f0f806700" provision.type="other"><no>(iii)</no><block><txt break.before="0">any proposed or existing on-site sewage treatment plant and on-site sewerage application area;</txt></block></li><li id="sec.14C-ssec.2-para1.b-para2.iv" guid="_a466e7ea-179f-4637-92fb-3be4e79d24e8" provision.type="other"><no>(iv)</no><block><txt break.before="0">any impervious surfaces on the premises, including, for example, paths for pedestrians and paved areas;</txt></block></li><li id="sec.14C-ssec.2-para1.b-para2.v" guid="_f37ec5d0-582d-4ddd-9da8-cc150ea74cb9" provision.type="other"><no>(v)</no><block><txt break.before="0">each body of water mentioned in <intref refid="sec.14C-ssec.2-para1.d" check="valid" target.guid="_44d812d9-8c03-41a0-a1f7-eb5e5766ba9a">paragraph&#160;(d)</intref>;</txt></block></li></list></block></li><li id="sec.14C-ssec.2-para1.c" guid="_b1c384d8-786d-4166-8701-a2eb27dbd716" provision.type="other"><no>(c)</no><block><txt break.before="0">the ground levels, referenced to AHD or appropriately reduced levels, to indicate whether sanitary drains can gravity feed to the connection point for the proposed greywater treatment plant or greywater diversion device;</txt></block></li><li id="sec.14C-ssec.2-para1.d" guid="_44d812d9-8c03-41a0-a1f7-eb5e5766ba9a" provision.type="other"><no>(d)</no><block><txt break.before="0">the location of each body of water that may be affected by the greywater from the proposed greywater treatment plant or greywater diversion device;</txt></block></li><li id="sec.14C-ssec.2-para1.e" guid="_9abcd643-e44b-4a2d-b2cf-9de9a32342b6" provision.type="other"><no>(e)</no><block><txt break.before="0">details of the water supply to the premises;</txt><note id="sec.14C-ssec.2-para1.e-note" guid="_0457fb99-7c17-4e66-8e5d-48a55a0fb202" type="example"><heading id="sec.14C-ssec.2-para1.e-note-he" guid="_c8cd2814-5d75-4277-ab82-b76e9933b06c">Examples of details of the water supply—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.2-para1.e-note-para2" guid="_6e4ad667-d7d5-4f3a-93ef-a568b350b7cf" provision.type="other"><no>•</no><block><txt break.before="0">for compliance assessable work in the SEQ region—information to show the supply of water to the premises by a distributor-retailer is adequate</txt></block></li><li id="sec.14C-ssec.2-para1.e-note-para2-oc.2" guid="_86a7cf3a-da17-4e37-b9fd-abbe26f46630" provision.type="other"><no>•</no><block><txt break.before="0">information about the availability of water from on-site water tanks</txt></block></li></list></block></note></block></li><li id="sec.14C-ssec.2-para1.f" guid="_2ad268a7-126a-46ef-875f-4fbe4028b2d3" provision.type="other"><no>(f)</no><block><txt break.before="0">if the work is not for testing purposes—the proposed greywater treatment plant’s type and size.</txt></block></li></list></block></subclause><subclause id="sec.14C-ssec.3" guid="_56cff506-cffe-4682-8d31-666cd178ded6" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Each of the following must be included—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.3-para1.a" guid="_b286970b-af6c-4726-93d7-1af7430e97bc" provision.type="other"><no>(a)</no><block><txt break.before="0">a site and soil evaluation report, within the meaning of the QPW code, for the premises;</txt></block></li><li id="sec.14C-ssec.3-para1.b" guid="_8e881372-3b23-44f4-b860-fe5cdabbf0f2" provision.type="other"><no>(b)</no><block><txt break.before="0">if the work is not for testing purposes—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.3-para1.b-para2.i" guid="_4767f93f-51f6-4c79-9268-0ed00df52e46" provision.type="other"><no>(i)</no><block><txt break.before="0">a document showing plumbing code authorisation and certification for the proposed greywater diversion device; or</txt></block></li><li id="sec.14C-ssec.3-para1.b-para2.ii" guid="_c6b9b089-7afd-459f-b691-939e9fedac82" provision.type="other"><no>(ii)</no><block><txt break.before="0">a chief executive approval for the proposed greywater treatment plant;</txt></block></li></list></block></li><li id="sec.14C-ssec.3-para1.c" guid="_aa9f04fc-5128-43bd-b8ae-8cdb50a73649" provision.type="other"><no>(c)</no><block><txt break.before="0">if the work is for testing purposes—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14C-ssec.3-para1.c-para2.i" guid="_0d51e45b-5dba-4254-bcc5-8ab78289b751" provision.type="other"><no>(i)</no><block><txt break.before="0">details of the testing approval for the proposed greywater use facility, including any conditions the chief executive imposes on the approval; and</txt></block></li><li id="sec.14C-ssec.3-para1.c-para2.ii" guid="_205d4cdf-a4a5-49f6-8850-f83eef3d02d0" provision.type="other"><no>(ii)</no><block><txt break.before="0">any other information that the local government requires in relation to the testing;</txt></block></li></list></block></li><li id="sec.14C-ssec.3-para1.d" guid="_ff650bca-3aa1-4a86-a8f0-98f4b5093830" provision.type="other"><no>(d)</no><block><txt break.before="0">details of the proposed use of the greywater from the greywater use facility.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;14C</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;22</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;8</legref>; <legref jurisd="QLD" type="act" target.doc.id="act-2010-020" target.version.series="5fb4eb5d-9c27-4de2-a4e4-4784083a9657" valid.date="as.made" check="valid">2010 Act&#160;No.&#160;20</legref> <legref jurisd="QLD" type="act" refid="sec.62" target.doc.id="act-2010-020" valid.date="as.made" check="invalid">s&#160;62</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;19</legref></txt></historynote></clause><clause id="sec.14D" guid="_119a8124-d2ef-48db-90f5-6d7da0febc0a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>14D</no><heading id="sec.14D-he" guid="_1e50c213-0d1a-47f3-8e43-5ff15037bca3">Additional requirements for plans for on-site sewerage facilities</heading><subclause id="sec.14D-ssec.1" guid="_4d806cbf-0f0e-46e3-a6ce-e30ac42dfded" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.14" check="valid" target.guid="_51f30e52-c636-40e2-8da2-a6b8f9a6c11b">section&#160;14</intref>, to a compliance request for compliance assessable work for an on-site sewerage facility.</txt></block></subclause><subclause id="sec.14D-ssec.2" guid="_00bfeff9-91ff-47bc-b955-e2d0d9d8be74" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">There must be a site plan of the premises on which the on-site sewerage work is to be performed showing each of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14D-ssec.2-para1.a" guid="_dce9b12e-2276-4f34-975f-986533ea7bc2" provision.type="other"><no>(a)</no><block><txt break.before="0">the location of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14D-ssec.2-para1.a-para2.i" guid="_189962f2-d63f-4596-af87-944dc6c9de57" provision.type="other"><no>(i)</no><block><txt break.before="0">the proposed on-site sewage treatment plant;</txt></block></li><li id="sec.14D-ssec.2-para1.a-para2.ii" guid="_21f3ec82-203f-4341-ad14-fc6610e0ba09" provision.type="other"><no>(ii)</no><block><txt break.before="0">the proposed on-site sewerage application area, including the layout of drainage for, and the proposed method of applying effluent to, the area;</txt></block></li></list></block></li><li id="sec.14D-ssec.2-para1.b" guid="_27f157ad-00dc-4312-bf0d-7b6695ae712f" provision.type="other"><no>(b)</no><block><txt break.before="0">the distances from the proposed on-site sewerage application area to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14D-ssec.2-para1.b-para2.i" guid="_7cf8e01e-b4b0-47e9-8808-6de9c37f9dc9" provision.type="other"><no>(i)</no><block><txt break.before="0">the boundary of the premises;</txt></block></li><li id="sec.14D-ssec.2-para1.b-para2.ii" guid="_983315d3-cdf0-4f49-95e3-d4b1e4e0b49a" provision.type="other"><no>(ii)</no><block><txt break.before="0">proposed or existing buildings or structures on the premises;</txt></block></li><li id="sec.14D-ssec.2-para1.b-para2.iii" guid="_7cea810a-9577-428e-9593-722a11d34d46" provision.type="other"><no>(iii)</no><block><txt break.before="0">any impervious surfaces on the premises, including, for example, paths for pedestrians and paved areas;</txt></block></li><li id="sec.14D-ssec.2-para1.b-para2.iv" guid="_cfec6ce2-5a90-4f6e-90c5-f46bc2f44331" provision.type="other"><no>(iv)</no><block><txt break.before="0">each body of water mentioned in <intref refid="sec.14D-ssec.2-para1.d" check="valid" target.guid="_b4ca095f-0727-4431-9f65-1c175b96931d">paragraph&#160;(d)</intref>;</txt></block></li></list></block></li><li id="sec.14D-ssec.2-para1.c" guid="_4061f421-be2b-4ca3-a905-84b1fe050cdf" provision.type="other"><no>(c)</no><block><txt break.before="0">the ground levels, referenced to AHD or appropriately reduced levels, to indicate whether sanitary drains can gravity feed to the connection point for the proposed on-site sewage treatment plant;</txt></block></li><li id="sec.14D-ssec.2-para1.d" guid="_b4ca095f-0727-4431-9f65-1c175b96931d" provision.type="other"><no>(d)</no><block><txt break.before="0">the location of each body of water that may be affected by the effluent from the proposed on-site sewerage facility;</txt></block></li><li id="sec.14D-ssec.2-para1.e" guid="_d8723c97-3c30-4268-a7d7-3c486edd6148" provision.type="other"><no>(e)</no><block><txt break.before="0">details of the water supply to the premises;</txt><note id="sec.14D-ssec.2-para1.e-note" guid="_5e7c1fbb-a8df-44cb-88ee-3b537acbee7f" type="example"><heading id="sec.14D-ssec.2-para1.e-note-he" guid="_3176355c-db8b-415f-8e32-affc341170c5">Examples of details of the water supply—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.14D-ssec.2-para1.e-note-para2" guid="_13720026-e756-4d9a-a21c-dc022fcc10d1" provision.type="other"><no>•</no><block><txt break.before="0">for compliance assessable work in the SEQ region—information to show the supply of water to the premises by a distributor-retailer is adequate</txt></block></li><li id="sec.14D-ssec.2-para1.e-note-para2-oc.2" guid="_11e66f13-1009-497b-afd2-9f9a1805dccf" provision.type="other"><no>•</no><block><txt break.before="0">information about the availability of water from on-site water tanks</txt></block></li></list></block></note></block></li><li id="sec.14D-ssec.2-para1.f" guid="_24ec73af-cf55-438b-8cf3-03e6a4cce715" provision.type="other"><no>(f)</no><block><txt break.before="0">if the work is not for testing purposes—the proposed on-site sewage treatment plant’s type and size.</txt></block></li></list></block></subclause><subclause id="sec.14D-ssec.3" guid="_48f6dc29-1a99-4fb6-b210-5def4d102deb" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Each of the following must be included—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14D-ssec.3-para1.a" guid="_caa5151f-ce4b-482e-b6ae-f8cdf0746496" provision.type="other"><no>(a)</no><block><txt break.before="0">a site and soil evaluation report, within the meaning of the QPW code, for the premises;</txt></block></li><li id="sec.14D-ssec.3-para1.b" guid="_63499dd5-f581-4f39-8a47-edc4c9c551b8" provision.type="other"><no>(b)</no><block><txt break.before="0">if the work is not for testing purposes—a document showing plumbing code authorisation and certification, or a chief executive approval, for the proposed on-site sewerage facility;</txt></block></li><li id="sec.14D-ssec.3-para1.c" guid="_05102f3b-42ed-471d-a8a8-3d29ba5d5ac0" provision.type="other"><no>(c)</no><block><txt break.before="0">if the work is for testing purposes—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.14D-ssec.3-para1.c-para2.i" guid="_825db0c6-35b1-42a9-a610-2e6753e3a649" provision.type="other"><no>(i)</no><block><txt break.before="0">details of the testing approval for the proposed on-site sewerage facility, including any conditions the chief executive imposes on the approval; and</txt></block></li><li id="sec.14D-ssec.3-para1.c-para2.ii" guid="_75e87c82-fe68-4bec-8917-b199fc8f4c1e" provision.type="other"><no>(ii)</no><block><txt break.before="0">any other information that the local government requires in relation to the testing.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;14D</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;22</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="act" target.doc.id="act-2010-020" target.version.series="5fb4eb5d-9c27-4de2-a4e4-4784083a9657" valid.date="as.made" check="valid">2010 Act&#160;No.&#160;20</legref> <legref jurisd="QLD" type="act" refid="sec.63" target.doc.id="act-2010-020" valid.date="as.made" check="invalid">s&#160;63</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.20" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;20</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;8</legref></txt></historynote></clause><clause id="sec.15" guid="_51e26611-caa5-4620-8cb0-8ceabe5ade4a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>15</no><heading id="sec.15-he" guid="_a10fcff4-12d7-4bc7-81b9-59f1342839e0">Certificates for plan given by competent person</heading><subclause id="sec.15-ssec.1" guid="_27e5cf14-3126-4b22-9547-ae597c0c5240" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a plan for compliance assessable work includes a part of the work that the chief executive officer of the local government decides is outside the local government’s expertise to assess.</txt></block></subclause><subclause id="sec.15-ssec.2" guid="_07cbd496-5d76-4ce8-ae36-2899655bf3f9" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may accept certification of the plan and associated documents by a competent person.</txt></block></subclause><subclause id="sec.15-ssec.3" guid="_dc7dbb67-0359-44cf-a5e8-df9594315320" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The competent person may certify for a plan that plumbing or drainage to which certified documentation relates will, if installed or carried out in accordance with the certified documentation, comply with this regulation.</txt></block></subclause><subclause id="sec.15-ssec.4" guid="_52d18c3c-58a5-4f8f-9d72-c2b722586332" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The name and original signature of the competent person must be on the certified documentation.</txt></block></subclause><subclause id="sec.15-ssec.5" guid="_bb5563fc-24ba-4412-ad6c-65d828685a30" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">If the certified documentation is prepared on behalf of a corporation or other entity, the name of the corporation or entity must also be on the certified documentation.</txt></block></subclause><subclause id="sec.15-ssec.6" guid="_beea5879-05db-4ea2-a988-d5e435244a94" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">The competent person must personally sign a certificate supporting the certified documentation.</txt></block></subclause><subclause id="sec.15-ssec.7" guid="_f4f13c24-84fc-4174-9a63-a82b4437a1c0" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">If the competent person would be required to be licensed for performing the part of the work mentioned in <intref refid="sec.15-ssec.1" check="valid" target.guid="_27e5cf14-3126-4b22-9547-ae597c0c5240">subsection&#160;(1)</intref>, the person’s registration or licence number must be on the certificate.</txt></block></subclause><subclause id="sec.15-ssec.8" guid="_35243e77-fbdb-4849-bef2-4daf934ead32" affected.by.uncommenced="0" provision.type="other"><no>(8)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.15-ssec.8-def.certifieddocumentation_" guid="_d09211d0-a708-4788-8c9f-dee023c91c5c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.15-ssec.8-def.certifieddocumentation" guid="_cfe1350a-bf2f-44fc-93a9-216460d949c3" type="definition">certified documentation</defterm>, in relation to a plan and associated documents, includes technical details, drawings and specifications for the plan or documents that are given and certified by a competent person.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;15</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.23" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;23</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;21</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;9</legref></txt></historynote></clause><clause id="sec.16" guid="_69f0c0f3-e4db-41e9-8b30-56fd2774898b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>16</no><heading id="sec.16-he" guid="_1a9ea1ac-a24b-4b99-bd30-9a0473007ea3">Requirement for additional documents for particular plans</heading><subclause id="sec.16-ssec.1" guid="_eaad0a0d-94b4-43d3-8cff-4082096130d1" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.1-para1.a" guid="_74321655-c1c6-411b-b561-ded6edef49ab" provision.type="other"><no>(a)</no><block><txt break.before="0">a person makes a compliance request for a plan; and</txt></block></li><li id="sec.16-ssec.1-para1.b" guid="_cc96a2e0-451c-44b2-a9f2-921629d50c38" provision.type="other"><no>(b)</no><block><txt break.before="0">the plan proposes to comply with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.1-para1.b-para2.i" guid="_ae23849a-e5d9-4737-b0fa-a3a872ca61d8" provision.type="other"><no>(i)</no><block><txt break.before="0">the performance requirements of the applied provisions or the PCA by formulating an alternative solution that is a means of compliance with the applied provisions or the PCA; or</txt></block></li><li id="sec.16-ssec.1-para1.b-para2.ii" guid="_99a1e08c-f02f-44ac-8a2a-bd6f56f70227" provision.type="other"><no>(ii)</no><block><txt break.before="0">the performance criteria of the QPW code by formulating an alternative solution within the meaning of the code.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.16-ssec.2" guid="_19730a6b-14b9-4d37-8a48-ac4f17199a11" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Each of the following must accompany the request—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.2-para1.a" guid="_d877ae47-e37b-49d1-9bd2-c5b1e2a2bed5" provision.type="other"><no>(a)</no><block><txt break.before="0">a statement—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.16-ssec.2-para1.a-para2.i" guid="_e8787169-6aaa-4215-b060-b0da02b1da85" provision.type="other"><no>(i)</no><block><txt break.before="0">identifying each performance requirement or performance criteria the solution is intending to satisfy; and</txt></block></li><li id="sec.16-ssec.2-para1.a-para2.ii" guid="_90e3e180-c93b-4156-a376-3d32719e7c68" provision.type="other"><no>(ii)</no><block><txt break.before="0">stating how each performance requirement or performance criteria is satisfied by the solution;</txt></block></li></list></block></li><li id="sec.16-ssec.2-para1.b" guid="_2616439f-2f66-43a3-92c5-d6ad7e41207b" provision.type="other"><no>(b)</no><block><txt break.before="0">details of inspection or test results and other documents or information relied on to develop the solution;</txt></block></li><li id="sec.16-ssec.2-para1.c" guid="_ac4d6d72-5b90-4034-87a4-e6a84b01b7b2" provision.type="other"><no>(c)</no><block><txt break.before="0">details of the solution, including, for example, to what extent and specifically how the solution differs from the acceptable solution for the performance requirement or performance criteria;</txt></block></li><li id="sec.16-ssec.2-para1.d" guid="_0a0ebe10-ad12-4cb3-a8ac-f69b077613a7" provision.type="other"><no>(d)</no><block><txt break.before="0">if the solution, or part of the solution, for a performance requirement or performance criteria requires a certified document for the plan—a certificate from the competent person who certified the document.</txt></block></li></list></block></subclause><subclause id="sec.16-ssec.3" guid="_082a592f-0fb9-47f2-9bb5-95171ee76c1e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.16-ssec.3-def.certifieddocument_" guid="_c60d4b8f-21a0-4441-8223-1c2a8382c8ae" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.16-ssec.3-def.certifieddocument" guid="_b2d1690f-22cd-4b40-bd3a-9df67f6d97e1" type="definition">certified document</defterm>, for a plan, includes technical details, drawings and specifications for the plan that are given and certified by a competent person.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;16</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;24</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24-ssec.2" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid"/></txt></historynote></clause></division><division id="pt.3-div.3" guid="_5b899131-8220-4658-b6ac-d8642aefedb5" affected.by.uncommenced="0"><no>Division 3</no><heading id="pt.3-div.3-he" guid="_1c1fc39d-50d1-4f23-9c3f-7e9e86c5be6c">Assessing plumbing and drainage work</heading><historynote><txt break.before="1"><b>div hdg</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.25" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;25</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;10</legref></txt></historynote><clause id="sec.17" guid="_34e6336e-b977-4e06-83d3-5aa063074d20" status="repealed" affected.by.uncommenced="0" spent.amends="0" provision.type="other" toc="no"><no>17</no><heading id="sec.17-he" guid="_90d754e6-fda4-4a20-ac54-a10dfc2f1fdc">Definition for <intref refid="pt.3-div.3" check="valid" target.guid="_5b899131-8220-4658-b6ac-d8642aefedb5">div&#160;3</intref></heading><block><deflist><definition id="sec.17_" guid="_8e019367-d8c7-4352-8313-363649fd3316" affected.by.uncommenced="0"><txt break.before="1"><defterm guid="_cf3c0eec-4c4f-45e7-aea6-80aaa982886a" type="mention">48 hours</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_d642703e-8c07-4190-8aed-30060bceae57" type="mention">48 hours</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.26" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;26</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;22</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22-ssec.2" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">(2)</legref></txt></historynote><historynote><txt break.before="1">om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;11</legref></txt></historynote></definition><definition id="sec.17_-oc.2" guid="_7454eef3-dcb9-47ae-8fc9-da977322400e" affected.by.uncommenced="0"><txt break.before="1"><defterm guid="_7ee94c2a-e5e1-4e56-ba25-0672b9144c25" type="mention">responsible person</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_1de28912-d338-40eb-92dc-b00dd0085733" type="mention">responsible person</defterm> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.26" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;26</legref></txt></historynote><historynote><txt break.before="1">om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;22</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22-ssec.1" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition></deflist></block><historynote><txt break.before="1"><b>s&#160;17</b> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;11</legref></txt></historynote></clause><clause id="sec.18" guid="_8440f54b-0907-496e-a00e-ac495643e4fc" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>18</no><heading id="sec.18-he" guid="_dd54541a-9a55-4db5-9a21-7e694fdd118a">Request for compliance assessment of compliance assessable work</heading><subclause id="sec.18-ssec.1" guid="_10d7a600-2d7c-4c54-aab1-0a3b771b3cb9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A person who makes, under <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.2" target.doc.id="UNKNOWN" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, a request for compliance assessment of compliance assessable work must make the request at least 2 business days before the work starts.</txt></block><penalty id="sec.18-ssec.1-pen" guid="_84e0b240-e71c-45d3-827d-f9ebc8b3b4d4"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.18-ssec.2" guid="_bac1b199-e300-48d6-947b-54cfbd7a237d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If, because of <legref jurisd="QLD" type="subordleg" refid="sec.83" target.doc.id="UNKNOWN" check="invalid">section&#160;83</legref><legref jurisd="QLD" type="subordleg" refid="sec.83-ssec.2" target.doc.id="UNKNOWN" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, a person does not require a compliance permit to perform compliance assessable work, the person must, if required by the local government, give the local government information or documents needed to assess the compliance assessable work, including, for example, the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.18-ssec.2-para1.a" guid="_a79b08ea-789b-45cc-a50c-dd50234f1003" provision.type="other"><no>(a)</no><block><txt break.before="0">a site plan showing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.18-ssec.2-para1.a-para2.i" guid="_78fc6d20-bda5-436a-838d-b8e051a54111" provision.type="other"><no>(i)</no><block><txt break.before="0">the location of proposed or existing buildings or structures; and</txt></block></li><li id="sec.18-ssec.2-para1.a-para2.ii" guid="_f1ecb7f1-e4d4-45be-a062-b65275862449" provision.type="other"><no>(ii)</no><block><txt break.before="0">the ground levels referenced to AHD to indicate whether sanitary drains can gravity feed to the connection point for the sewer or on-site sewerage facility;</txt></block></li></list></block></li><li id="sec.18-ssec.2-para1.b" guid="_99988bf5-73d4-4baa-baf9-91c31fa52e6c" provision.type="other"><no>(b)</no><block><txt break.before="0">a plan of the location of each connection point to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.18-ssec.2-para1.b-para2.i" guid="_844c9fa5-a2ed-4174-95a5-d43e8c3692b6" provision.type="other"><no>(i)</no><block><txt break.before="0">a service provider’s water supply or sewerage system; or</txt></block></li><li id="sec.18-ssec.2-para1.b-para2.ii" guid="_c5b79e78-4825-4661-a028-018951d7c8e9" provision.type="other"><no>(ii)</no><block><txt break.before="0">an on-site sewerage facility;</txt></block></li></list></block></li><li id="sec.18-ssec.2-para1.c" guid="_ab064632-4531-4e86-88d4-6fa4f503e8bb" provision.type="other"><no>(c)</no><block><txt break.before="0">the proposed location and details of installation for the plumbing or drainage.</txt></block></li></list></block></subclause><subclause id="sec.18-ssec.3" guid="_fa1b1b87-adf4-409c-a82c-21e6e4dd97e3" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">A person making a request for compliance assessment of on-site sewerage work must give the local government a notice in the approved form of any relevant changes to the premises since the granting of the compliance permit for the work.</txt></block><penalty id="sec.18-ssec.3-pen" guid="_d412e643-b466-4111-852b-cdbf106c0ab2"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.18-ssec.4" guid="_1081c789-16e3-4710-85cb-ec5e6ada8de8" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.18-ssec.4-def.relevantchange_" guid="_d1fee63a-3db8-4ecf-b30d-9d9060a908c8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.18-ssec.4-def.relevantchange" guid="_846ab590-51f4-4cdc-9c5b-51522d9d57ca" type="definition">relevant change</defterm>, for premises, means a change to the premises that would have altered the information given when applying, under <legref jurisd="QLD" type="subordleg" refid="sec.85" target.doc.id="UNKNOWN" check="invalid">section&#160;85</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, for the relevant compliance permit.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;18</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.27" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;27</legref> <legref jurisd="QLD" type="subordleg" refid="sec.27-ssec.2" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid"/>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.23" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;23</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;12</legref></txt></historynote></clause><clause id="sec.19" guid="_b65ce007-d610-4f46-8493-d5a1e66ebece" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>19</no><heading id="sec.19-he" guid="_baa68954-133e-419c-b7de-5e7190874c25">Stages for assessment of compliance assessable work</heading><subclause id="sec.19-ssec.1" guid="_0ef74899-7f43-400c-9d99-42bb5174c426" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Each of the following stages of compliance assessable work is prescribed for <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.5" target.doc.id="UNKNOWN" check="invalid">(5)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec.1-para1.a" guid="_df12c7b0-0d50-42d5-a011-45a7a148489c" provision.type="other"><no>(a)</no><block><txt break.before="0">for plumbing or drainage laid under a floor slab or in another area where pipes or fittings will be covered—before the floor slab is laid or the pipes or fittings are covered;</txt></block></li><li id="sec.19-ssec.1-para1.b" guid="_3d25d68f-a0aa-4e3d-a82f-33599577d7ec" provision.type="other"><no>(b)</no><block><txt break.before="0">for plumbing or drainage that is laid below ground level and external to a building or other structure—before the backfill is placed;</txt></block></li><li id="sec.19-ssec.1-para1.c" guid="_9fa44c2b-92c1-43c9-a263-91ee8eaa91d5" provision.type="other"><no>(c)</no><block><txt break.before="0">for plumbing installed in a building or other structure—before the cladding or lining covering the plumbing is fixed;</txt></block></li><li id="sec.19-ssec.1-para1.d" guid="_40475b93-82bd-4930-8e11-5dbdf2335f35" provision.type="other"><no>(d)</no><block><txt break.before="0">when the plumbing or drainage work, the subject of the request for compliance assessment, is completed;</txt></block></li><li id="sec.19-ssec.1-para1.e" guid="_81476ee2-9074-46ee-8dd6-61c70d35bc8c" provision.type="other"><no>(e)</no><block><txt break.before="0">for a greywater use facility—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec.1-para1.e-para2.i" guid="_b42bef5c-234f-4bdf-893e-857ecd81db9e" provision.type="other"><no>(i)</no><block><txt break.before="0">if the facility includes a greywater application area—after the sub-surface or surface irrigation in the area is installed; and</txt></block></li><li id="sec.19-ssec.1-para1.e-para2.ii" guid="_84b9e554-f045-4f3b-a1df-c64ffbe5c580" provision.type="other"><no>(ii)</no><block><txt break.before="0">if the greywater is proposed to be used other than in a greywater application area—when the plumbing work associated with each proposed use of the greywater is completed;</txt></block></li></list></block></li><li id="sec.19-ssec.1-para1.f" guid="_74d29413-16f3-4788-b20e-3d0bb2bcc823" provision.type="other"><no>(f)</no><block><txt break.before="0">if the relevant compliance permit imposes a condition requiring an assessment at 1 or more other stages of the work—each stage stated in the condition.</txt></block></li></list></block></subclause><subclause id="sec.19-ssec.2" guid="_ec2961df-b04e-4de6-817e-822388a367b9" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The responsible person for the work must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19-ssec.2-para1.a" guid="_72e03d42-838d-4219-ba9a-a5cb4eec6d23" provision.type="other"><no>(a)</no><block><txt break.before="0">request an assessment of the work at each of the applicable stages mentioned in <intref refid="sec.19-ssec.1" check="valid" target.guid="_0ef74899-7f43-400c-9d99-42bb5174c426">subsection&#160;(1)</intref>; and</txt></block></li><li id="sec.19-ssec.2-para1.b" guid="_c3377ff0-01d6-4ee2-8e1f-6d6561797a19" provision.type="other"><no>(b)</no><block><txt break.before="0">for the stage mentioned <intref refid="sec.19-ssec.1" check="valid" target.guid="_0ef74899-7f43-400c-9d99-42bb5174c426">subsection&#160;(1)</intref><intref refid="sec.19-ssec.1-para1.d" check="valid" target.guid="_40475b93-82bd-4930-8e11-5dbdf2335f35">(d)</intref>—make the request within 7 days after the work is completed; and</txt></block></li><li id="sec.19-ssec.2-para1.c" guid="_c1683f0d-8439-4ae4-89d8-93024c571ab4" provision.type="other"><no>(c)</no><block><txt break.before="0">if the responsible person is not the person who made the request for compliance assessment under <intref refid="sec.18" check="valid" target.guid="_8440f54b-0907-496e-a00e-ac495643e4fc">section&#160;18</intref><intref refid="sec.18-ssec.1" check="valid" target.guid="_10d7a600-2d7c-4c54-aab1-0a3b771b3cb9">(1)</intref>—state the responsible person’s name; and</txt></block></li><li id="sec.19-ssec.2-para1.d" guid="_2df7417f-fd7f-440a-863c-52a8095735a1" provision.type="other"><no>(d)</no><block><txt break.before="0">before or when the work is assessed, give the local government details in the approved form of the responsible person.</txt></block></li></list></block><penalty id="sec.19-ssec.2-pen" guid="_bf9dafe6-a9e8-441f-8320-2b89f0256ffb"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.19-ssec.3" guid="_ffcab3a6-03a8-4841-b36f-f224a17bdfcb" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, if the local government requires information or documents under <intref refid="sec.18" check="valid" target.guid="_8440f54b-0907-496e-a00e-ac495643e4fc">section&#160;18</intref><intref refid="sec.18-ssec.2" check="valid" target.guid="_bac1b199-e300-48d6-947b-54cfbd7a237d">(2)</intref>, the responsible person may request an assessment of the work only if the information or documents have been provided to the local government.</txt></block></subclause><subclause id="sec.19-ssec.4" guid="_ba632960-2e89-4dd1-a651-ef36b350922e" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">For the purposes of this section, compliance assessable work is completed when the work becomes operational.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;19</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.28" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;28</legref> <legref jurisd="QLD" type="subordleg" refid="sec.28-ssec.2" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid"/>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;9</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;24</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24-ssec.2" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid"/>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.13" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;13</legref></txt></historynote></clause><clause id="sec.19A" guid="_63424aea-01a1-4152-ad9f-c2c4bf5bb7ed" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>19A</no><heading id="sec.19A-he" guid="_b6868db4-20ae-437f-9684-00c5f4477e87">Stages for assessment of compliance assessable work that is on-site sewerage work</heading><block><txt break.before="1">Each of the following stages of compliance assessable work that is on-site sewerage work is prescribed for <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.5" target.doc.id="UNKNOWN" check="invalid">(5)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19A-para1.a" guid="_cbe7bf73-ac38-459d-b30c-610aac05956e" provision.type="other"><no>(a)</no><block><txt break.before="0">for a trench or sub-surface irrigation—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19A-para1.a-para2.i" guid="_0b8db7dc-8823-4e75-9220-0834dc074307" provision.type="other"><no>(i)</no><block><txt break.before="0">before filling with backfill; or</txt></block></li><li id="sec.19A-para1.a-para2.ii" guid="_ee2bab2e-ca15-42db-8bbc-d8962e2cf509" provision.type="other"><no>(ii)</no><block><txt break.before="0">after substantially filling with backfill but leaving a cross-sectional area of the trench or sub-surface irrigation not backfilled;</txt></block></li></list></block></li><li id="sec.19A-para1.b" guid="_c438436b-3c44-450d-a750-ac20488745cf" provision.type="other"><no>(b)</no><block><txt break.before="0">after all pipes for the relevant on-site sewerage facility are connected, and effluent resulting from sewage generated on the premises can be treated by the on-site sewage treatment plant;</txt></block></li><li id="sec.19A-para1.c" guid="_d555ffd3-7061-47e2-96d6-f4b4bfcfb0bf" provision.type="other"><no>(c)</no><block><txt break.before="0">if the relevant compliance permit imposes a condition requiring an assessment at 1 or more other stages of the work—each stage stated in the condition.</txt></block></li></list></block><historynote><txt break.before="1"><b>s&#160;19A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;29</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.14" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;14</legref></txt></historynote></clause><clause id="sec.19B" guid="_43a10c57-6daf-46a3-9203-ef8053f878c2" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>19B</no><heading id="sec.19B-he" guid="_d471960d-cc54-4075-b8ab-1cb5d6d6c3f0">Obligations of responsible person for compliance assessable work that is on-site sewerage work</heading><block><txt break.before="1">If <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.6" target.doc.id="UNKNOWN" check="invalid">(6)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> does not apply, the responsible person for compliance assessable work that is on-site sewerage work must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19B-para1.a" guid="_efcd9235-762b-4c9d-8614-a494f8c29664" provision.type="other"><no>(a)</no><block><txt break.before="0">request the local government to assess the work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.19B-para1.a-para2.i" guid="_94183def-40b0-4d6a-923d-8535d939fbcf" provision.type="other"><no>(i)</no><block><txt break.before="0">at each of the stages for the work prescribed under <intref refid="sec.19A" check="valid" target.guid="_63424aea-01a1-4152-ad9f-c2c4bf5bb7ed">section&#160;19A</intref>; and</txt></block></li><li id="sec.19B-para1.a-para2.ii" guid="_1b170d8e-68b3-448a-9229-f196f858d00b" provision.type="other"><no>(ii)</no><block><txt break.before="0">for the stage mentioned in <intref refid="sec.19A" check="valid" target.guid="_63424aea-01a1-4152-ad9f-c2c4bf5bb7ed">section&#160;19A</intref><intref refid="sec.19A-para1.b" check="valid" target.guid="_c438436b-3c44-450d-a750-ac20488745cf">(b)</intref>—within 7 days after the work is completed; and</txt></block></li></list></block></li><li id="sec.19B-para1.b" guid="_83ac4b2c-5cce-4069-8ee0-f95ffda2f5e4" provision.type="other"><no>(b)</no><block><txt break.before="0">if the responsible person is not the person who made the request for compliance assessment under <intref refid="sec.18" check="valid" target.guid="_8440f54b-0907-496e-a00e-ac495643e4fc">section&#160;18</intref><intref refid="sec.18-ssec.1" check="valid" target.guid="_10d7a600-2d7c-4c54-aab1-0a3b771b3cb9">(1)</intref>—give the local government the responsible person’s name when first requesting an assessment of the work; and</txt></block></li><li id="sec.19B-para1.c" guid="_dd31c676-1fa3-44d3-a093-564770811aa0" provision.type="other"><no>(c)</no><block><txt break.before="0">if there is a different responsible person for a stage of work (a <defterm id="sec.19B-def.newresponsibleperson" guid="_35779ec4-7372-46e8-994d-b19b99038d5e" type="definition">new responsible person</defterm>) from the responsible person for the previous stage of work—give the local government the new responsible person’s name when requesting an assessment of the new responsible person’s stage of work; and</txt></block></li><li id="sec.19B-para1.d" guid="_061ea6bf-4456-4b9a-8d6a-5c80bb18ce8d" provision.type="other"><no>(d)</no><block><txt break.before="0">before or when the work is assessed, give the local government details in the approved form of the responsible person.</txt></block></li></list></block><penalty id="sec.19B-pen" guid="_bee16997-0c4d-470c-8c6e-f3593ec10118"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty><historynote><txt break.before="1"><b>s&#160;19B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;29</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;15</legref></txt></historynote></clause><clause id="sec.20" guid="_88ec21a4-a5c4-48bd-90e7-ae6e515e5bb9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>20</no><heading id="sec.20-he" guid="_116fc1f9-ee77-4c07-937f-399065b2d797">Assessment of stages of work by local government</heading><subclause id="sec.20-ssec.1" guid="_09d925f1-1fd3-4980-a525-ce4973c502a2" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if the local government receives a request for assessment of a particular stage of compliance assessable work.</txt></block></subclause><subclause id="sec.20-ssec.2" guid="_33a88157-5c8b-4b5f-be6d-a20a48fde710" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An inspector must start assessing the work within 1 hour after—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.20-ssec.2-para1.a" guid="_ae2f0d3a-b0db-4399-a5f0-d388b1324d8f" provision.type="other"><no>(a)</no><block><txt break.before="0">the time agreed between the responsible person for the work and the local government; or</txt></block></li><li id="sec.20-ssec.2-para1.b" guid="_6ac4f062-9d75-4bcd-83c2-39a4b924abb5" provision.type="other"><no>(b)</no><block><txt break.before="0">if a time is not agreed—48 hours after the local government receives the request.</txt></block></li></list></block></subclause><subclause id="sec.20-ssec.3" guid="_8b0cff0a-4691-40dc-bc8b-84a076609144" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The responsible person must give the inspector the help the inspector reasonably requires to inspect the work.</txt></block></subclause><subclause id="sec.20-ssec.4" guid="_acc40858-1bba-40a6-a180-ad1146c49eb4" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If, in deciding the request, the inspector gives the responsible person written notice of the action required to make the relevant plumbing or drainage comply with this regulation, the person must, within 2 business days after receiving the notice—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.20-ssec.4-para1.a" guid="_72d5d600-d99d-405b-a60b-5a9179ca0f4e" provision.type="other"><no>(a)</no><block><txt break.before="0">comply with the notice; and</txt></block></li><li id="sec.20-ssec.4-para1.b" guid="_ad51c46f-1761-4461-9f8c-e5a8c1b0d2ac" provision.type="other"><no>(b)</no><block><txt break.before="0">make a request for assessment of the work that is the subject of the notice.</txt></block></li></list></block><penalty id="sec.20-ssec.4-pen" guid="_e0a4d450-3229-4951-99de-4d32628f0fe8"><block><txt break.before="1">Maximum penalty for <intref refid="sec.20-ssec.4" check="valid" target.guid="_acc40858-1bba-40a6-a180-ad1146c49eb4">subsection&#160;(4)</intref>—20 penalty units.</txt></block></penalty></subclause><historynote><txt break.before="1"><b>s&#160;20</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.30" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;30</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.25" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;25</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.16" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;16</legref></txt></historynote></clause><clause id="sec.21" guid="_2b3111c4-ef35-41bb-932f-9ac0e6320071" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>21</no><heading id="sec.21-he" guid="_9386df98-7544-42b7-b7ee-290cd8d1f3e4">Covering plumbing and drainage</heading><subclause id="sec.21-ssec.1" guid="_09bd1981-c82e-490c-a4a9-80452f1198b3" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A responsible person for compliance assessable work must not cover, or allow another person to cover, the relevant plumbing or drainage unless an inspector has—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.21-ssec.1-para1.a" guid="_d5678e7a-cbc5-4e77-9999-71a4f4bb0cd4" provision.type="other"><no>(a)</no><block><txt break.before="0">assessed the work and decided it complies with this regulation; or</txt></block></li><li id="sec.21-ssec.1-para1.b" guid="_55d9cf6c-4e6e-45bf-8ce5-2299c37ec410" provision.type="other"><no>(b)</no><block><txt break.before="0">allowed the plumbing or drainage to be covered; or</txt></block></li><li id="sec.21-ssec.1-para1.c" guid="_ae9dc245-3297-4151-b1db-4effe6308678" provision.type="other"><no>(c)</no><block><txt break.before="0">for on-site sewerage work—accepted from an approved person a notice of compliance for the work given under <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.6" target.doc.id="UNKNOWN" check="invalid">(6)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>.</txt></block></li></list></block><penalty id="sec.21-ssec.1-pen" guid="_24a3a0e7-1e7a-4240-84a5-144e0445f78f"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.21-ssec.2" guid="_14592bcb-57e5-4683-a083-b1b291d242e2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the person fails to comply with <intref refid="sec.21-ssec.1" check="valid" target.guid="_09bd1981-c82e-490c-a4a9-80452f1198b3">subsection&#160;(1)</intref>, the inspector may—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.21-ssec.2-para1.a" guid="_0f48e5e6-9e58-47e1-b632-5fff33f1e548" provision.type="other"><no>(a)</no><block><txt break.before="0">require the person to verify the work complies with this regulation; or</txt></block></li><li id="sec.21-ssec.2-para1.b" guid="_376ae780-c336-4237-988b-190e25d799be" provision.type="other"><no>(b)</no><block><txt break.before="0">give the person written notice of the action required to enable the inspector to assess whether the work complies.</txt></block></li></list></block></subclause><subclause id="sec.21-ssec.3" guid="_a1d90be4-30c0-4039-8817-e3dfe757fa51" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, the person may cover the plumbing or drainage if the inspector fails to start assessing the work within 1 hour after—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.21-ssec.3-para1.a" guid="_ceae8fa6-f49c-4eff-b221-4ed6cee6d5a8" provision.type="other"><no>(a)</no><block><txt break.before="0">the agreed time for the assessment; or</txt></block></li><li id="sec.21-ssec.3-para1.b" guid="_d345657c-8f5d-4ccf-9907-889b2d82f5e7" provision.type="other"><no>(b)</no><block><txt break.before="0">if a time is not agreed—48 hours after the local government receives the request.</txt></block></li></list></block></subclause><subclause id="sec.21-ssec.4" guid="_2fd91c05-1ff8-481f-9ebf-31146e541c37" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the person covers the plumbing or drainage under <intref refid="sec.21-ssec.3" check="valid" target.guid="_a1d90be4-30c0-4039-8817-e3dfe757fa51">subsection&#160;(3)</intref>, the inspector may require the person to verify in the approved form that the work complies with this regulation.</txt></block></subclause><subclause id="sec.21-ssec.5" guid="_3c1f2be6-86a6-4f51-ad76-f0aaae5574ed" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">A person must provide verification required of the person under <intref refid="sec.21-ssec.2" check="valid" target.guid="_14592bcb-57e5-4683-a083-b1b291d242e2">subsection&#160;(2)</intref><intref refid="sec.21-ssec.2-para1.a" check="valid" target.guid="_0f48e5e6-9e58-47e1-b632-5fff33f1e548">(a)</intref> or <intref refid="sec.21-ssec.4" check="valid" target.guid="_2fd91c05-1ff8-481f-9ebf-31146e541c37">(4)</intref>.</txt></block><penalty id="sec.21-ssec.5-pen" guid="_757b3203-bca3-4fff-a769-c51244f95210"><block><txt break.before="1">Maximum penalty—10 penalty units.</txt></block></penalty></subclause><historynote><txt break.before="1"><b>s&#160;21</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.31" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;31</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.26" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;26</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.17" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;17</legref></txt></historynote></clause><clause id="sec.22" guid="_bf7985a2-f008-426f-8e65-3c0b2e131b7b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>22</no><heading id="sec.22-he" guid="_0b3c4c52-7bf8-4e0d-9219-018a4665256b">Testing and commissioning plumbing and drainage</heading><subclause id="sec.22-ssec.1" guid="_5088f7bd-061e-4b64-a3d7-99c15f1fa713" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">If an inspector requires plumbing or drainage, the subject of compliance assessable work, to be tested or commissioned—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.1-para1.a" guid="_6aab9144-4b25-4dea-91da-d57c299cfcef" provision.type="other"><no>(a)</no><block><txt break.before="0">the inspector must observe the testing or commissioning of the plumbing or drainage; or</txt></block></li><li id="sec.22-ssec.1-para1.b" guid="_39aefe9e-a672-46fc-8811-325ceb750cb5" provision.type="other"><no>(b)</no><block><txt break.before="0">if the inspector allows, an approved person must test, commission or observe the testing or commissioning of the plumbing or drainage.</txt></block></li></list></block></subclause><subclause id="sec.22-ssec.2" guid="_c5ff7214-efdf-4d5d-b11d-8c8b08e096a1" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An inspector may allow an approved person to test or commission the plumbing and drainage only if the work is work mentioned in <intref refid="sch.5" check="valid" target.guid="_de7922dd-3d08-4c61-952c-938f2ea5ebf9">schedule&#160;5</intref>.</txt></block></subclause><subclause id="sec.22-ssec.3" guid="_e0ffac59-e712-419a-9854-78ddf3d8c0c5" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An approved person must test or commission the plumbing or drainage—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.3-para1.a" guid="_a25a6462-584f-4bd7-b1ff-6b2c5204cbc7" provision.type="other"><no>(a)</no><block><txt break.before="0">for plumbing or drainage installed to comply with a deemed-to-satisfy provision under PCA—in accordance with the relevant applied provision mentioned in <intref refid="sch.5" check="valid" target.guid="_de7922dd-3d08-4c61-952c-938f2ea5ebf9">schedule&#160;5</intref>, <intref refid="sch.5-pt.1" check="valid" target.guid="_0c101d05-83a2-47ff-866c-62c808a7c59b">part&#160;1</intref>; or</txt></block></li><li id="sec.22-ssec.3-para1.b" guid="_4f1fa920-5e34-4d18-a19b-a4c8866d5159" provision.type="other"><no>(b)</no><block><txt break.before="0">for plumbing or drainage installed to comply with an alternative solution—to ensure the plumbing or drainage complies with the relevant performance requirements under PCA, or other requirements, mentioned in <intref refid="sch.5" check="valid" target.guid="_de7922dd-3d08-4c61-952c-938f2ea5ebf9">schedule&#160;5</intref>, <intref refid="sch.5-pt.2" check="valid" target.guid="_742feb21-1417-4430-9855-c3a776e06fb5">part&#160;2</intref>.</txt></block></li></list></block></subclause><subclause id="sec.22-ssec.4" guid="_5feca172-30be-4780-9ac9-ad4a5de4e96f" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If <intref refid="sec.22-ssec.2" check="valid" target.guid="_c5ff7214-efdf-4d5d-b11d-8c8b08e096a1">subsection&#160;(2)</intref> applies, the approved person must, within 5 business days after testing or commissioning the plumbing or drainage, give the responsible person a report about the testing or commissioning (a <defterm id="sec.22-def.compliancereport" guid="_bae60299-cd02-42d3-ba65-ee825cddac3c" type="definition">compliance report</defterm>) complying with <intref refid="sec.22-ssec.5" check="valid" target.guid="_bae2b5bb-0e50-4dce-90bc-554e97c700b9">subsection&#160;(5)</intref>.</txt></block><penalty id="sec.22-ssec.4-pen" guid="_07ffa7ed-592d-4355-bab7-c7521b10bf34"><block><txt break.before="1">Maximum penalty—10 penalty units.</txt></block></penalty></subclause><subclause id="sec.22-ssec.5" guid="_bae2b5bb-0e50-4dce-90bc-554e97c700b9" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">The compliance report must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.5-para1.a" guid="_6910719c-4250-4f50-8a56-0d6abac0feed" provision.type="other"><no>(a)</no><block><txt break.before="0">state—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.5-para1.a-para2.i" guid="_232daf24-a78b-42b0-a104-c5d33e389495" provision.type="other"><no>(i)</no><block><txt break.before="0">that the approved person has tested or commissioned the plumbing or drainage in accordance with the applied provisions; or</txt></block></li><li id="sec.22-ssec.5-para1.a-para2.ii" guid="_ea666b7b-00dd-4096-bedd-6504d0a45ceb" provision.type="other"><no>(ii)</no><block><txt break.before="0">that the approved person has observed the testing or commissioning of the plumbing or drainage and that the plumbing or drainage was tested or commissioned in accordance with the applied provisions; and</txt></block></li></list></block></li><li id="sec.22-ssec.5-para1.b" guid="_2ad1d1ad-3d6d-41f1-881b-34225558b1e8" provision.type="other"><no>(b)</no><block><txt break.before="0">state the extent to which the approved person has relied on tests, specifications, rules, standards, codes of practice or other publications; and</txt></block></li><li id="sec.22-ssec.5-para1.c" guid="_bf60afc9-a168-4bda-99f1-ed9a38abec7a" provision.type="other"><no>(c)</no><block><txt break.before="0">state whether the plumbing or drainage complies with the applied provisions; and</txt></block></li><li id="sec.22-ssec.5-para1.d" guid="_9b36ab18-465d-4b6f-ac71-b678439d4849" provision.type="other"><no>(d)</no><block><txt break.before="0">if the plumbing or drainage does not comply with the applied provisions, state the extent to which the plumbing or drainage does not comply; and</txt></block></li><li id="sec.22-ssec.5-para1.e" guid="_4c35e52a-3484-4897-b6fd-c8c804670fe1" provision.type="other"><no>(e)</no><block><txt break.before="0">be signed by the approved person.</txt></block></li></list></block></subclause><subclause id="sec.22-ssec.6" guid="_4998e1c6-0fa6-4fec-a8ee-4693e6e6dd02" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">The responsible person for the compliance assessable work must give the local government the compliance report—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.6-para1.a" guid="_8014b9ce-aa98-4253-ae0e-ee7002325a31" provision.type="other"><no>(a)</no><block><txt break.before="0">within 10 business days after the testing or commissioning of the plumbing or drainage; or</txt></block></li><li id="sec.22-ssec.6-para1.b" guid="_aeb6b4a7-a9c3-4e20-896f-dc91116cdc5f" provision.type="other"><no>(b)</no><block><txt break.before="0">if the local government allows—at a time more than 10 business days after the testing or commissioning.</txt></block></li></list></block><penalty id="sec.22-ssec.6-pen" guid="_4f652541-0169-40f9-9faa-580db244f11e"><block><txt break.before="1">Maximum penalty—10 penalty units.</txt></block></penalty></subclause><subclause id="sec.22-ssec.7" guid="_39f8933a-4950-4fc6-bd70-f07651676c22" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.22-ssec.7-def.approvedperson_" guid="_c04c51a3-71c0-4ed9-b6e7-f5404d07fefc" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.22-ssec.7-def.approvedperson" guid="_5f365cf3-43b1-4abc-889d-fe4b1bacf4bb" type="definition">approved person</defterm> means—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.7-def.approvedperson-para1.a" guid="_e26dd3ce-dc89-4521-9829-d2b64645d9fd" provision.type="other"><no>(a)</no><block><txt break.before="0">the person who performed the compliance assessable work; or</txt></block></li><li id="sec.22-ssec.7-def.approvedperson-para1.b" guid="_6a6e0a31-82e8-4b77-9460-616a067d9dd5" provision.type="other"><no>(b)</no><block><txt break.before="0">another person who—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.22-ssec.7-def.approvedperson-para1.b-para2.i" guid="_3912b73c-af08-4551-b678-9ea59802397e" provision.type="other"><no>(i)</no><block><txt break.before="0">in the opinion of the local government, is competent to test or commission the plumbing or drainage; and</txt></block></li><li id="sec.22-ssec.7-def.approvedperson-para1.b-para2.ii" guid="_edd017f0-9c9e-46a6-a9ee-d1af5dd02846" provision.type="other"><no>(ii)</no><block><txt break.before="0">if required under the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> or another Act to be registered or licensed to practise in the aspect of the work, is registered or licensed.</txt></block></li></list></block></li></list></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;22</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.32" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;32</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.27" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;27</legref></txt></historynote></clause><clause id="sec.23" guid="_55705a21-237e-42f6-b51d-2a771f52be2a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>23</no><heading id="sec.23-he" guid="_c9ab3f8b-ce13-4fc1-a9d2-ec9838307acb">General requirements for plans for assessed work</heading><subclause id="sec.23-ssec.1" guid="_c08c7f74-955f-444b-99b5-f65176f602f9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if, under <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.7" target.doc.id="UNKNOWN" check="invalid">(7)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, the local government asks a person making a request for compliance assessment of compliance assessable work to supply a plan for the assessed work.</txt></block></subclause><subclause id="sec.23-ssec.2" guid="_ede626a9-406d-4aa0-b3c2-5282f1f3dbce" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must contain enough information about the work to enable the local government to keep an accurate record of the plumbing or drainage that is the subject of the work.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;23</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.33" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;33</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.28" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;28</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.18" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;18</legref></txt></historynote></clause><clause id="sec.23A" guid="_98c9a4da-4bb6-4f0d-b967-e29929f86459" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>23A</no><heading id="sec.23A-he" guid="_68a33414-ef4b-433b-adcf-6d861d771ce6">Additional requirements for plans for assessed compliance assessable work</heading><subclause id="sec.23A-ssec.1" guid="_a1307503-0e40-429f-b4fc-39a13d25fd53" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">section&#160;23</intref>, to a request for a plan for assessed compliance assessable work.</txt></block></subclause><subclause id="sec.23A-ssec.2" guid="_c4ce3c32-3bb2-483b-96ab-23060e0097a4" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the work is in relation to a building classified under BCA as a class 1 building on a lot that is part of a community titles scheme or a class 2 to 9 building, the plan must be drawn to scale and show—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23A-ssec.2-para1.a" guid="_305b9d42-8592-4911-b244-830941260dac" provision.type="other"><no>(a)</no><block><txt break.before="0">the location, including dimensions, of each connection point to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23A-ssec.2-para1.a-para2.i" guid="_303d9010-d221-4339-8588-2b40a39857c2" provision.type="other"><no>(i)</no><block><txt break.before="0">the service provider’s water supply or sewerage system; or</txt></block></li><li id="sec.23A-ssec.2-para1.a-para2.ii" guid="_0c63cc3c-f8b3-42c0-be61-87015a9e795a" provision.type="other"><no>(ii)</no><block><txt break.before="0">the on-site sewerage facility; and</txt></block></li></list></block></li><li id="sec.23A-ssec.2-para1.b" guid="_e112175b-43ab-44bd-8f6c-5cb4cf47aabe" provision.type="other"><no>(b)</no><block><txt break.before="0">the location on the premises of the following items—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23A-ssec.2-para1.b-para2.i" guid="_f4b0d1ab-71aa-483f-9372-c63a01f2f415" provision.type="other"><no>(i)</no><block><txt break.before="0">all fixtures, water supply pipes, sanitary drains and water meters;</txt></block></li><li id="sec.23A-ssec.2-para1.b-para2.ii" guid="_077351f9-fe64-4799-9253-aafd6ea869a6" provision.type="other"><no>(ii)</no><block><txt break.before="0">each connection point to the service provider’s water supply or sewerage system, or to the on-site sewerage facility;</txt></block></li><li id="sec.23A-ssec.2-para1.b-para2.iii" guid="_b5bfcc47-cf00-4091-bb18-e5ba3317d2cf" provision.type="other"><no>(iii)</no><block><txt break.before="0">each access point for cleaning and maintaining the plumbing and drainage;</txt></block></li><li id="sec.23A-ssec.2-para1.b-para2.iv" guid="_98984e60-f17e-44a4-9f20-d0fdf3b3c511" provision.type="other"><no>(iv)</no><block><txt break.before="0">each reflux valve installed in the drainage;</txt></block></li><li id="sec.23A-ssec.2-para1.b-para2.v" guid="_e1ba366a-124b-46a1-a478-59f67dddea02" provision.type="other"><no>(v)</no><block><txt break.before="0">any installed testable backflow prevention devices.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.23A-ssec.3" guid="_05acac2f-f2ed-449c-bbcd-c9718b63fcac" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the work is in relation to a building classified under BCA as a class 1 building or class 10 building, other than a class 1 building mentioned in <intref refid="sec.23A-ssec.2" check="valid" target.guid="_c4ce3c32-3bb2-483b-96ab-23060e0097a4">subsection&#160;(2)</intref>, the plan must be drawn approximately to scale and show—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23A-ssec.3-para1.a" guid="_0a74114e-f691-4724-b335-464d7508237b" provision.type="other"><no>(a)</no><block><txt break.before="0">the location, including dimensions, of each connection point to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23A-ssec.3-para1.a-para2.i" guid="_55e158bb-3f6a-4a0e-9c1a-710e341b48e2" provision.type="other"><no>(i)</no><block><txt break.before="0">the service provider’s water supply or sewerage system; or</txt></block></li><li id="sec.23A-ssec.3-para1.a-para2.ii" guid="_f85172cd-8650-4b4d-a2e7-3487a0aca652" provision.type="other"><no>(ii)</no><block><txt break.before="0">the on-site sewerage facility; and</txt></block></li></list></block></li><li id="sec.23A-ssec.3-para1.b" guid="_d025349c-848b-42fd-8ba5-b33086174405" provision.type="other"><no>(b)</no><block><txt break.before="0">the approximate location on the premises of the following items—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23A-ssec.3-para1.b-para2.i" guid="_347a36bb-94d4-434a-b161-6ffe763941dd" provision.type="other"><no>(i)</no><block><txt break.before="0">all fixtures, water supply pipes and sanitary drains;</txt></block></li><li id="sec.23A-ssec.3-para1.b-para2.ii" guid="_5fee0a7b-b28d-486f-8054-ffc4fce27a29" provision.type="other"><no>(ii)</no><block><txt break.before="0">each connection point to the service provider’s water supply or sewerage system, or to the on-site sewerage facility;</txt></block></li><li id="sec.23A-ssec.3-para1.b-para2.iii" guid="_6f1b0bcb-e86a-479b-a920-10b10303e21a" provision.type="other"><no>(iii)</no><block><txt break.before="0">each access point for cleaning and maintaining the plumbing and drainage;</txt></block></li><li id="sec.23A-ssec.3-para1.b-para2.iv" guid="_48f135de-1454-48ad-a419-e5cdaacb7797" provision.type="other"><no>(iv)</no><block><txt break.before="0">each reflux valve installed in the drainage;</txt></block></li><li id="sec.23A-ssec.3-para1.b-para2.v" guid="_848301e8-db80-4196-b39d-5f61b2e647cc" provision.type="other"><no>(v)</no><block><txt break.before="0">any installed testable backflow prevention devices.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;23A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.33" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;33</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;10</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;29</legref></txt></historynote></clause><clause id="sec.23B" guid="_299366db-9c02-4e10-b746-a4d6c229aeed" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>23B</no><heading id="sec.23B-he" guid="_c8911ffa-649f-4470-a4d0-74584dbcd52f">Additional requirements for plans for assessed greywater use facilities in a sewered area</heading><subclause id="sec.23B-ssec.1" guid="_f88b7cdb-ea04-466d-97cf-08b0c519a251" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">sections&#160;23</intref> and <intref refid="sec.23A" check="valid" target.guid="_98c9a4da-4bb6-4f0d-b967-e29929f86459">23A</intref>, to a request for compliance assessable work for, or that includes, a greywater use facility in a sewered area.</txt></block></subclause><subclause id="sec.23B-ssec.2" guid="_c78a1b7e-fb52-4b61-afd4-47ef50a522eb" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must be drawn approximately to scale and show the following if the greywater use facility includes a greywater application area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23B-ssec.2-para1.a" guid="_79b909ac-542f-445f-bdf9-afbaeb437e4f" provision.type="other"><no>(a)</no><block><txt break.before="0">the location of the area;</txt></block></li><li id="sec.23B-ssec.2-para1.b" guid="_33adaf62-192b-4fa1-bd50-4173927ace4c" provision.type="other"><no>(b)</no><block><txt break.before="0">the distances from the area to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23B-ssec.2-para1.b-para2.i" guid="_aaa78c89-a03a-4baf-acd0-d91e452274dc" provision.type="other"><no>(i)</no><block><txt break.before="0">the boundary of the premises;</txt></block></li><li id="sec.23B-ssec.2-para1.b-para2.ii" guid="_fda3d083-06d5-4f91-abbe-9ddb3de8486b" provision.type="other"><no>(ii)</no><block><txt break.before="0">proposed or existing buildings or structures on the premises.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.23B-ssec.3" guid="_bb7d2837-7995-4941-8f07-d8067de2ab85" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The plan must include details of the proposed use of the greywater from the greywater use facility.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;23B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.33" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;33</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;11</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.30" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;30</legref></txt></historynote></clause><clause id="sec.23C" guid="_b50bd7c5-e22b-4b1e-99c4-7150153728bd" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>23C</no><heading id="sec.23C-he" guid="_7b3f4d25-4919-4182-b915-e2002d6a58bd">Additional requirements for plans for assessed greywater use facilities not in a sewered area</heading><subclause id="sec.23C-ssec.1" guid="_49eb711a-534b-4e58-b098-6bbcf846ac7a" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">sections&#160;23</intref> and <intref refid="sec.23A" check="valid" target.guid="_98c9a4da-4bb6-4f0d-b967-e29929f86459">23A</intref>, to a request for compliance assessable work for, or that includes, a greywater use facility not in a sewered area.</txt></block></subclause><subclause id="sec.23C-ssec.2" guid="_2eb38068-c36f-48af-8aea-2cd7ced58144" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must be drawn approximately to scale and show the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23C-ssec.2-para1.a" guid="_e56a4b01-ceaf-444f-983a-cd48055510c7" provision.type="other"><no>(a)</no><block><txt break.before="0">the location of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23C-ssec.2-para1.a-para2.i" guid="_efd05cfc-f80e-4162-a521-04258967d612" provision.type="other"><no>(i)</no><block><txt break.before="0">if the greywater use facility includes a greywater application area—the area;</txt></block></li><li id="sec.23C-ssec.2-para1.a-para2.ii" guid="_819c8edd-4aba-419e-b147-83cb48178955" provision.type="other"><no>(ii)</no><block><txt break.before="0">any proposed or existing on-site sewage treatment plant;</txt></block></li><li id="sec.23C-ssec.2-para1.a-para2.iii" guid="_90c5caef-494f-4109-8318-0a8d9cd4d720" provision.type="other"><no>(iii)</no><block><txt break.before="0">any proposed or existing on-site sewerage application area, including the layout of drainage for, and the proposed method of applying greywater to, the area;</txt></block></li></list></block></li><li id="sec.23C-ssec.2-para1.b" guid="_b949e511-30d6-4d54-9b9a-d9490bc5b65d" provision.type="other"><no>(b)</no><block><txt break.before="0">if the facility includes a greywater application area—the distances from the area to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23C-ssec.2-para1.b-para2.i" guid="_7af9061e-f713-40b8-b603-6ebec0575d89" provision.type="other"><no>(i)</no><block><txt break.before="0">the boundary of the premises;</txt></block></li><li id="sec.23C-ssec.2-para1.b-para2.ii" guid="_a27e0f10-d988-4337-8986-3ae284dcf228" provision.type="other"><no>(ii)</no><block><txt break.before="0">proposed or existing buildings or structures on the premises;</txt></block></li><li id="sec.23C-ssec.2-para1.b-para2.iii" guid="_d895d271-0174-439a-86cb-ff90372a0fc4" provision.type="other"><no>(iii)</no><block><txt break.before="0">any proposed or existing on-site sewerage application area.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.23C-ssec.3" guid="_182f0907-6d9c-4410-9cc2-a3e31b18d028" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The plan must include details of the proposed use of the greywater from the greywater use facility.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;23C</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.33" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;33</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;12</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.31" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;31</legref></txt></historynote></clause><clause id="sec.23D" guid="_739c4607-bb1f-4ce5-b5b0-eb6021c24713" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>23D</no><heading id="sec.23D-he" guid="_afc9a43d-5296-4e41-9307-3fb6159db0a9">Additional requirements for plans for assessed on-site sewerage work</heading><subclause id="sec.23D-ssec.1" guid="_681d77b8-0c2d-460d-90df-e95c0fd14a80" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies, as well as <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">section&#160;23</intref>, to a request for a plan for assessed on-site sewerage work.</txt></block></subclause><subclause id="sec.23D-ssec.2" guid="_05fc1150-0ab2-4014-92ce-a43042216a65" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must be drawn approximately to scale and show the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23D-ssec.2-para1.a" guid="_5a5259a4-cc57-439d-b75c-558974d71c85" provision.type="other"><no>(a)</no><block><txt break.before="0">the location of proposed or existing buildings or structures on the premises on which the on-site sewerage facility has been installed;</txt></block></li><li id="sec.23D-ssec.2-para1.b" guid="_c2d37497-f7bb-4dee-a0cf-97ac660155a6" provision.type="other"><no>(b)</no><block><txt break.before="0">the location of the on-site sewage treatment plant;</txt></block></li><li id="sec.23D-ssec.2-para1.c" guid="_6af5f76d-2829-48cd-a0e3-6799a12ec438" provision.type="other"><no>(c)</no><block><txt break.before="0">the location of the on-site sewerage application area;</txt></block></li><li id="sec.23D-ssec.2-para1.d" guid="_761456d1-abfe-4f21-8bcb-48f1ff4723ba" provision.type="other"><no>(d)</no><block><txt break.before="0">the distances from the on-site sewerage application area to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.23D-ssec.2-para1.d-para2.i" guid="_faf51e58-bb66-40ba-9fb4-3926949024d2" provision.type="other"><no>(i)</no><block><txt break.before="0">the boundary of the premises;</txt></block></li><li id="sec.23D-ssec.2-para1.d-para2.ii" guid="_f2402766-187f-4c0b-8098-65decfc8d07a" provision.type="other"><no>(ii)</no><block><txt break.before="0">buildings or structures on the premises;</txt></block></li></list></block></li><li id="sec.23D-ssec.2-para1.e" guid="_2674fc4a-c08b-41fb-982a-8bc3d4d841a0" provision.type="other"><no>(e)</no><block><txt break.before="0">the location of each body of water that may be affected by effluent from the on-site sewerage facility;</txt></block></li><li id="sec.23D-ssec.2-para1.f" guid="_4942bca9-5542-4dd9-a5cd-a51620f98683" provision.type="other"><no>(f)</no><block><txt break.before="0">the distances between the on-site sewerage facility and each body of water mentioned in <intref refid="sec.23D-ssec.2-para1.e" check="valid" target.guid="_2674fc4a-c08b-41fb-982a-8bc3d4d841a0">paragraph&#160;(e)</intref>.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;23D</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.33" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;33</legref></txt></historynote></clause></division><division id="pt.3-div.4" guid="_dcf7eca5-b453-47c2-baa8-65d9f93c7db6" affected.by.uncommenced="0"><no>Division 4</no><heading id="pt.3-div.4-he" guid="_7d8f66f4-2f89-4be6-9b29-0e9ed7517b93">Assessing compliance assessable work in remote areas</heading><historynote><txt break.before="1"><b>div hdg</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.34" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;34</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.32" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;32</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.19" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;19</legref></txt></historynote><clause id="sec.24" guid="_215de4c7-606d-47aa-aa07-aed45bc48e84" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>24</no><heading id="sec.24-he" guid="_b88e29b6-ba61-4051-9d69-6e2572c21247">Application of <intref refid="pt.3-div.4" check="valid" target.guid="_dcf7eca5-b453-47c2-baa8-65d9f93c7db6">div&#160;4</intref></heading><block><txt break.before="1">This division applies, under <legref jurisd="QLD" type="subordleg" refid="sec.86A" target.doc.id="UNKNOWN" check="invalid">section&#160;86A</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, for the assessment of compliance assessable work in a remote area.</txt></block><historynote><txt break.before="1"><b>s&#160;24</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.35" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;35</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.33" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;33</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.20" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;20</legref></txt></historynote></clause><clause id="sec.25" guid="_45b0ae2b-e409-47ee-b66b-4b2a20dfc770" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>25</no><heading id="sec.25-he" guid="_1f653d95-4ca6-4c45-9e5e-7e9f4af5da05">Meaning of <defterm guid="_02ba84ae-a5f3-47fe-85cf-24e4090df853" type="mention">remote area</defterm></heading><subclause id="sec.25-ssec.1" guid="_1c5d90fe-2ef2-4df6-b949-889b310710d9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A <defterm id="sec.25-def.remotearea-oc.2" guid="_1b7dbdd1-491a-4270-94ca-70e30a566ac4" type="definition">remote area</defterm> means an area of land included in a local government’s area—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.25-ssec.1-para1.a" guid="_42b0a8c4-0837-4146-bd2f-fd3fa094f0c1" provision.type="other"><no>(a)</no><block><txt break.before="0">all of which is outside a declared water or sewerage service area under the Water Supply Act; and</txt></block></li><li id="sec.25-ssec.1-para1.b" guid="_e3c40245-10ad-4afc-be00-b5ae420bbe6e" provision.type="other"><no>(b)</no><block><txt break.before="0">none of which is within a populated place; and</txt></block></li><li id="sec.25-ssec.1-para1.c" guid="_32d3b0d6-c855-48e9-88bb-d1c000222810" provision.type="other"><no>(c)</no><block><txt break.before="0">all of which is—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.25-ssec.1-para1.c-para2.i" guid="_4d8f78d6-b365-47ca-a3dc-9ca7ac66f14a" provision.type="other"><no>(i)</no><block><txt break.before="0">more than 80km from the nearest office of the local government; or</txt></block></li><li id="sec.25-ssec.1-para1.c-para2.ii" guid="_fd043845-cc54-435f-a3f3-3fd8df0c2e9b" provision.type="other"><no>(ii)</no><block><txt break.before="0">reasonably difficult to access.</txt><note id="sec.25-ssec.1-para1.c-para2.ii-note" guid="_7db2d2d5-58ed-4041-91e8-5be816136b54" type="example"><heading id="sec.25-ssec.1-para1.c-para2.ii-note-he" guid="_a6a1956d-3313-4851-95d4-8821081e4080">Examples for <intref refid="sec.25-ssec.1-para1.c-para2.ii" check="valid" target.guid="_fd043845-cc54-435f-a3f3-3fd8df0c2e9b">subparagraph&#160;(ii)</intref>—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.25-ssec.1-para1.c-para2.ii-note-para3.1" guid="_2eab8fa7-8ea0-49df-a19e-8e0920833bdf" provision.type="other"><no>1</no><block><txt break.before="0">an island without a regular water vehicle service from the mainland</txt></block></li><li id="sec.25-ssec.1-para1.c-para2.ii-note-para3.2" guid="_b3211433-f6ab-4093-8b7e-b1adec352025" provision.type="other"><no>2</no><block><txt break.before="0">weather conditions or other circumstances that make usual access to the land difficult or dangerous</txt></block></li></list></block></note></block></li></list></block></li></list></block></subclause><subclause id="sec.25-ssec.2" guid="_f35aa61b-7ac1-440b-80a6-390a331ad8e6" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">However, a <defterm id="sec.25-def.remotearea-oc.3" guid="_94df576a-8de6-44ed-b38e-db6e793b9ce9" type="definition">remote area</defterm> does not include land if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.25-ssec.2-para1.a" guid="_1bc2fb0c-795b-418a-ae2f-86237a03bd44" provision.type="other"><no>(a)</no><block><txt break.before="0">there is an activity on the land, including, for example, mining or another industrial use; and</txt></block></li><li id="sec.25-ssec.2-para1.b" guid="_033236d0-9658-4944-8d45-fc1c1183f067" provision.type="other"><no>(b)</no><block><txt break.before="0">it is probable the nature of the activity will increase the likelihood and severity of harm to the public if the plumbing and drainage on the land does not operate effectively.</txt></block></li></list></block></subclause><subclause id="sec.25-ssec.3" guid="_cf8f07f8-ef0f-4582-b36d-70d6cad7f690" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.25-ssec.3-def.populatedplace_" guid="_a02c5c68-1bb9-4f05-a918-6f9558b05373" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.25-ssec.3-def.populatedplace" guid="_b798ce65-60eb-49b8-bb94-df98a8220641" type="definition">populated place</defterm> means a place with an approved name under the <legref jurisd="QLD" type="act" target.doc.id="act-1994-057" target.version.series="04e327fd-f1f3-426a-87f1-cafbecbf8428" check="valid"><name emphasis="yes">Place Names Act 1994</name></legref> and designated in the Gazetteer of Place Names under that Act as a populated place.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;25</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.36" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;36</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2011-0265" valid.date="as.made" check="invalid">s&#160;29</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.34" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;34</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.21" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;21</legref></txt></historynote></clause><clause id="sec.26" guid="_57d247d4-a2e1-42ae-b235-1eefa611ef87" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>26</no><heading id="sec.26-he" guid="_b8246f55-2f3e-47ad-bf92-5080811aef37">Request for compliance assessment of compliance assessable work</heading><block><txt break.before="1">A person who makes, under <legref jurisd="QLD" type="subordleg" refid="sec.86A" target.doc.id="UNKNOWN" check="invalid">section&#160;86A</legref><legref jurisd="QLD" type="subordleg" refid="sec.86A-ssec.2" target.doc.id="UNKNOWN" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, a request for compliance assessment of compliance assessable work, must make the request at least 2 business days before the work starts.</txt></block><penalty id="sec.26-pen" guid="_776b445e-3ba5-484a-b114-9b4b4bd6f324"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty><historynote><txt break.before="1"><b>s&#160;26</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.37" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;37</legref> <legref jurisd="QLD" type="subordleg" refid="sec.37-ssec.2" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid"/>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.35" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;35</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.22" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;22</legref></txt></historynote></clause><clause id="sec.27" guid="_642d5c34-30d0-44b5-8d6e-8e9d6b14bba5" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>27</no><heading id="sec.27-he" guid="_2db063a7-7e2c-499b-b53d-b9c92eb775ad">Testing and commissioning plumbing and drainage</heading><block><txt break.before="1">If a local government decides to test or commission plumbing or drainage, the subject of compliance assessable work carried out in a remote area, <intref refid="sec.22" check="valid" target.guid="_bf7985a2-f008-426f-8e65-3c0b2e131b7b">section&#160;22</intref> applies to the testing or commissioning of the plumbing or drainage as if the plumbing or drainage were the subject of compliance assessable work carried out in an area other than a remote area.</txt></block><historynote><txt break.before="1"><b>s&#160;27</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.36" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;36</legref></txt></historynote></clause><clause id="sec.28" guid="_6f9119f2-6606-4d54-8c07-2c56e1644836" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>28</no><heading id="sec.28-he" guid="_f907eba0-9c89-4241-9234-1f60341bf0f4">Plan of completed work</heading><subclause id="sec.28-ssec.1" guid="_730d49fd-0496-4adc-a272-c0aff49fa642" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if, under <legref jurisd="QLD" type="subordleg" refid="sec.86A" target.doc.id="UNKNOWN" check="invalid">section&#160;86A</legref><legref jurisd="QLD" type="subordleg" refid="sec.86A-ssec.3" target.doc.id="UNKNOWN" check="invalid">(3)</legref><legref jurisd="QLD" type="subordleg" refid="sec.86A-ssec.3-para1.b" target.doc.id="UNKNOWN" check="invalid">(b)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, the local government asks a person making a request for compliance assessment of compliance assessable work to supply a plan of the completed work.</txt></block></subclause><subclause id="sec.28-ssec.2" guid="_4186d9ec-8a75-46c0-88ca-482bc83ea655" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The plan must comply with the requirements for a plan of assessed work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.28-ssec.2-para1.a" guid="_36bbbac6-88be-46e2-9f51-5b644055b8a1" provision.type="other"><no>(a)</no><block><txt break.before="0">for compliance assessable work—under <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">sections&#160;23</intref> and <intref refid="sec.23A" check="valid" target.guid="_98c9a4da-4bb6-4f0d-b967-e29929f86459">23A</intref>; or</txt></block></li><li id="sec.28-ssec.2-para1.b" guid="_f9807d5a-753f-469a-a70a-1c5b199591ac" provision.type="other"><no>(b)</no><block><txt break.before="0">for compliance assessable work for, or that includes, a greywater use facility in a sewered area—under <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">sections&#160;23</intref> to <intref refid="sec.23B" check="valid" target.guid="_299366db-9c02-4e10-b746-a4d6c229aeed">23B</intref>; or</txt></block></li><li id="sec.28-ssec.2-para1.c" guid="_1924da7e-e4dc-4272-a4b5-0397966bbd85" provision.type="other"><no>(c)</no><block><txt break.before="0">for compliance assessable work for, or that includes, a greywater use facility not in a sewered area—under <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">sections&#160;23</intref>, <intref refid="sec.23A" check="valid" target.guid="_98c9a4da-4bb6-4f0d-b967-e29929f86459">23A</intref> and <intref refid="sec.23C" check="valid" target.guid="_b50bd7c5-e22b-4b1e-99c4-7150153728bd">23C</intref>; or</txt></block></li><li id="sec.28-ssec.2-para1.d" guid="_0775fc23-14e1-4b2b-ad3a-6f4da3161c2a" provision.type="other"><no>(d)</no><block><txt break.before="0">for compliance assessable work for an on-site sewerage facility—under <intref refid="sec.23" check="valid" target.guid="_55705a21-237e-42f6-b51d-2a771f52be2a">sections&#160;23</intref> and <intref refid="sec.23D" check="valid" target.guid="_739c4607-bb1f-4ce5-b5b0-eb6021c24713">23D</intref>.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;28</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.38" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;38</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.37" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;37</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.23" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;23</legref></txt></historynote></clause><clause id="sec.29" guid="_18a06e30-9c00-4b48-9bd6-484c9b6d3aab" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>29</no><heading id="sec.29-he" guid="_4e4dd31b-1302-4d52-a15d-53d4a642e3e0">Notice of compliance</heading><subclause id="sec.29-ssec.1" guid="_e15cf767-27a1-4f6f-a634-b4698f2a4ed4" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A notice given under <legref jurisd="QLD" type="subordleg" refid="sec.86A" target.doc.id="UNKNOWN" check="invalid">section&#160;86A</legref><legref jurisd="QLD" type="subordleg" refid="sec.86A-ssec.3" target.doc.id="UNKNOWN" check="invalid">(3)</legref><legref jurisd="QLD" type="subordleg" refid="sec.86A-ssec.3-para1.a" target.doc.id="UNKNOWN" check="invalid">(a)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> must be given by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.29-ssec.1-para1.a" guid="_af7469d5-68f8-4cbf-a5b5-601239c47e35" provision.type="other"><no>(a)</no><block><txt break.before="0">the person who performs the work; or</txt></block></li><li id="sec.29-ssec.1-para1.b" guid="_cfe2335a-4353-4fa5-bda2-94a2e2d4112c" provision.type="other"><no>(b)</no><block><txt break.before="0">if the local government decides to accept notice from another person—an approved person.</txt></block></li></list></block></subclause><subclause id="sec.29-ssec.2" guid="_75bf16b0-c89e-4930-a12a-fefff1ca14ec" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The notice must be—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.29-ssec.2-para1.a" guid="_c5e8c013-5668-482f-bec5-d51caada2739" provision.type="other"><no>(a)</no><block><txt break.before="0">in the approved form; and</txt></block></li><li id="sec.29-ssec.2-para1.b" guid="_7b966d07-1071-4b4c-8e31-1f223f056b5e" provision.type="other"><no>(b)</no><block><txt break.before="0">given within 10 business days after the work is completed.</txt></block></li></list></block></subclause><subclause id="sec.29-ssec.3" guid="_865259f6-6141-4ae5-aadf-a05bf57d8377" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the local government decides to accept notice from an approved person, the local government must advise the person who performs the work of its decision.</txt></block></subclause><subclause id="sec.29-ssec.4" guid="_8c0890b4-16d6-40df-a702-1395ae3557fe" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">For the purposes of <intref refid="sec.29-ssec.2" check="valid" target.guid="_75bf16b0-c89e-4930-a12a-fefff1ca14ec">subsection&#160;(2)</intref><intref refid="sec.29-ssec.2-para1.b" check="valid" target.guid="_7b966d07-1071-4b4c-8e31-1f223f056b5e">(b)</intref>, compliance assessable work is completed when the work becomes operational.</txt></block></subclause><subclause id="sec.29-ssec.5" guid="_d93ce956-0b0e-4a66-a209-3faaf431fcb3" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.29-ssec.5-def.approvedperson_" guid="_63c856cc-9088-4d88-8e49-cc4d567b1ba3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.29-ssec.5-def.approvedperson" guid="_1895fa74-e3e8-487c-99e2-cfa99735dfdb" type="definition">approved person</defterm> means a person who—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.29-ssec.5-def.approvedperson-para1.a" guid="_672d8baa-cc0b-4322-9cec-5956d65cb1dc" provision.type="other"><no>(a)</no><block><txt break.before="0">in the opinion of the local government, is competent to verify the work complies with this regulation; and</txt></block></li><li id="sec.29-ssec.5-def.approvedperson-para1.b" guid="_b6872d97-0970-47a4-a448-eb2fc3db1d4f" provision.type="other"><no>(b)</no><block><txt break.before="0">if required by law to be registered or licensed under a law applying in the State to practise in the aspect of the work, is registered or licensed.</txt></block></li></list></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;29</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.24" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;24</legref></txt></historynote></clause></division><division id="pt.3-div.5" guid="_db00cb77-6853-42b7-8265-5b32c5a25eff" affected.by.uncommenced="0"><no>Division 5</no><heading id="pt.3-div.5-he" guid="_17bd3621-ea9a-445d-9387-3a43c97fb317">Inspecting notifiable work</heading><historynote><txt break.before="1"><b>div hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.38" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;38</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.25" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;25</legref></txt></historynote><clause id="sec.29A" guid="_27b211c2-c3ab-43a4-9788-3a79132d7a1c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>29A</no><heading id="sec.29A-he" guid="_4bcd1d8f-b1ad-4809-aaa2-1584416a12dc">Requests for inspection of notifiable work</heading><subclause id="sec.29A-ssec.1" guid="_69b5e040-e3cf-487a-8bfb-72ed9b3b9245" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A responsible person for notifiable work may request the local government to inspect the work for compliance with this regulation.</txt></block></subclause><subclause id="sec.29A-ssec.2" guid="_81e21ae6-b797-411c-985c-346d64fb5f13" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If a responsible person makes a request under <intref refid="sec.29A-ssec.1" check="valid" target.guid="_69b5e040-e3cf-487a-8bfb-72ed9b3b9245">subsection&#160;(1)</intref>, an inspector must start inspecting the work within—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.29A-ssec.2-para1.a" guid="_e298e155-8363-4147-82d7-cf0dbbcc6c4a" provision.type="other"><no>(a)</no><block><txt break.before="0">1 hour after the time agreed between the responsible person for the work and the local government; or</txt></block></li><li id="sec.29A-ssec.2-para1.b" guid="_a43e06df-82dd-4953-884c-9af90e978ec8" provision.type="other"><no>(b)</no><block><txt break.before="0">if a time is not agreed—48 hours after the local government receives the request.</txt></block></li></list><note id="sec.29A-ssec.2-note" guid="_dfcdc570-cafc-441e-a394-6acc97282389" type="example"><heading id="sec.29A-ssec.2-note-he" guid="_dcfe8e2f-911b-4153-a9e3-2a50f2d215ff">Notes—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.29A-ssec.2-note-para1.1" guid="_5367a6f8-4b4d-412e-97f8-96604fd15081" provision.type="other"><no>1</no><block><txt break.before="0">Under the <legref jurisd="QLD" type="act" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid"><name emphasis="yes">Local Government Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="sec.97" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid" target.guid="_623edd4d-5c13-4483-b884-4ac0358fcfd8">section&#160;97</legref> and the <legref jurisd="QLD" type="act" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid"><name emphasis="yes">City of Brisbane Act 2010</name></legref>, <legref jurisd="QLD" type="act" refid="sec.99" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid" target.guid="_d6782b3a-4a6f-468d-bfd1-718f4acb799a">section&#160;99</legref>, a local government may fix a cost-recovery fee for the performance of a responsibility imposed on the local government under the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>.</txt></block></li><li id="sec.29A-ssec.2-note-para1.2" guid="_b05d7c83-88d0-4789-b6d7-26b4fd366d82" provision.type="other"><no>2</no><block><txt break.before="0">An inspector for the local government may only enter private property with the permission of the occupier of the property or with a warrant. See the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, <legref jurisd="QLD" type="subordleg" refid="sec.114" target.doc.id="UNKNOWN" check="invalid">section&#160;114</legref><legref jurisd="QLD" type="subordleg" refid="sec.114-ssec.3" target.doc.id="UNKNOWN" check="invalid">(3)</legref>, the <legref jurisd="QLD" type="act" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid"><name emphasis="yes">Local Government Act 2009</name></legref>, <legref jurisd="QLD" type="act" refid="ch.5" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid" target.guid="_04149410-24bb-4194-a90d-6b51a125c1a7">chapter&#160;5</legref>, <legref jurisd="QLD" type="act" refid="ch.5-pt.2" target.doc.id="act-2009-017" target.version.series="6947b410-2c56-43b2-9d23-effa6933a450" check="valid" target.guid="_658fed0f-eb57-45db-af7f-2800a450f594">part&#160;2</legref> and the <legref jurisd="QLD" type="act" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid"><name emphasis="yes">City of Brisbane Act 2010</name></legref>, <legref jurisd="QLD" type="act" refid="ch.5" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid" target.guid="_89b02482-eb30-45ad-8d89-56a7584f6063">chapter&#160;5</legref>, <legref jurisd="QLD" type="act" refid="ch.5-pt.2" target.doc.id="act-2010-023" target.version.series="73e40041-4b86-4960-bd14-a56360d6b558" check="valid" target.guid="_095a2c7a-565c-42f1-821c-c3dd7f19fb1d">part&#160;2</legref>.</txt></block></li></list></block></note></block></subclause><subclause id="sec.29A-ssec.3" guid="_f1a8dc34-6070-42c3-9160-60c7c0d02aba" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The responsible person must give the inspector the help the inspector reasonably requires to inspect the work.</txt></block></subclause><subclause id="sec.29A-ssec.4" guid="_f1512ce1-8072-4073-ad07-42171341ab61" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">An inspector does not fail to comply with <intref refid="sec.29A-ssec.2" check="valid" target.guid="_81e21ae6-b797-411c-985c-346d64fb5f13">subsection&#160;(2)</intref> merely because the inspector is unable to enter the place where the work was performed to inspect the work.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;29A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.38" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;38</legref></txt></historynote><historynote><txt break.before="1">sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.26" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;26</legref></txt></historynote></clause><clause id="sec.29B" guid="_967c71d9-d6cd-40ae-8c33-3853803973f0" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>29B</no><heading id="sec.29B-he" guid="_72902255-1297-4657-8e5e-635a0f992eda">Rectification notices for inspections under <intref refid="sec.29A" check="valid" target.guid="_27b211c2-c3ab-43a4-9788-3a79132d7a1c">s&#160;29A</intref> or the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, <legref jurisd="QLD" type="subordleg" refid="sec.87" target.doc.id="UNKNOWN" check="invalid">s&#160;87</legref><legref jurisd="QLD" type="subordleg" refid="sec.87-ssec.8" target.doc.id="UNKNOWN" check="invalid">(8)</legref></heading><subclause id="sec.29B-ssec.1" guid="_f296bfd7-49af-4c10-8cfc-02441d1dbc60" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to notifiable work the subject of an inspection under <intref refid="sec.29A" check="valid" target.guid="_27b211c2-c3ab-43a4-9788-3a79132d7a1c">section&#160;29A</intref>, or <legref jurisd="QLD" type="subordleg" refid="sec.87" target.doc.id="UNKNOWN" check="invalid">section&#160;87</legref><legref jurisd="QLD" type="subordleg" refid="sec.87-ssec.8" target.doc.id="UNKNOWN" check="invalid">(8)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>.</txt></block></subclause><subclause id="sec.29B-ssec.2" guid="_2625b292-2c4d-4492-892d-fa2dbe014396" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the local government reasonably believes the work does not comply with this regulation, the local government may give a responsible person for the work written notice (a <defterm id="sec.29B-def.rectificationnotice" guid="_5f6b6959-5241-48ab-bcbf-cef4754fee62" type="definition">rectification notice</defterm>) of the action required to make the work comply.</txt></block></subclause><subclause id="sec.29B-ssec.3" guid="_6099e62d-734c-4c8e-ab23-cbc84c87fac5" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, if the QBCC commissioner has been given notice under <legref jurisd="QLD" type="subordleg" refid="sec.87" target.doc.id="UNKNOWN" check="invalid">section&#160;87</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> about the work, the local government may only give a rectification notice for the work within 12 months of the day notice of the work is given to the QBCC commissioner.</txt></block></subclause><subclause id="sec.29B-ssec.4" guid="_c13d4d4f-2985-423a-8082-2ad8dac72c40" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The rectification notice must state the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.29B-ssec.4-para1.a" guid="_e1992781-a7be-4a15-9a70-58b5ab2678a0" provision.type="other"><no>(a)</no><block><txt break.before="0">the action the local government considers necessary to make the work comply with this regulation (the <defterm id="sec.29B-ssec.4-def.rectificationwork" guid="_280a2085-6528-4666-8b5a-a7caef22c877" type="definition">rectification work</defterm>);</txt></block></li><li id="sec.29B-ssec.4-para1.b" guid="_a8af6bdd-9c1a-4ca0-8cec-cb99b7e8db2c" provision.type="other"><no>(b)</no><block><txt break.before="0">the rectification period;</txt></block></li><li id="sec.29B-ssec.4-para1.c" guid="_89a90871-2589-4818-9dfa-4fd83179a492" provision.type="other"><no>(c)</no><block><txt break.before="0">if the local government reasonably believes an inspection of the rectification work is required—that a responsible person must, before the end of the rectification period, request the local government to inspect the rectification work;</txt><note id="sec.29B-ssec.4-para1.c-note" guid="_de811700-ddf7-4899-b0e0-d8d6eec0e720" type="example"><heading id="sec.29B-ssec.4-para1.c-note-he" guid="_534a8c9e-c42a-43de-a455-caba20ee6754">Note—</heading><block><txt break.before="1">See <intref refid="sec.29A" check="valid" target.guid="_27b211c2-c3ab-43a4-9788-3a79132d7a1c">section&#160;29A</intref> for requests for inspection of notifiable work.</txt></block></note></block></li><li id="sec.29B-ssec.4-para1.d" guid="_88e12d10-0968-40d2-ab2b-d7cc4910390d" provision.type="other"><no>(d)</no><block><txt break.before="0">any conditions the local government considers reasonable;</txt><note id="sec.29B-ssec.4-para1.d-note" guid="_e6cb5b95-8eb6-45f9-a4d7-5d9d0766cd45" type="example"><heading id="sec.29B-ssec.4-para1.d-note-he" guid="_7b7b51e2-8f4a-4684-9981-3c604e7e9e67">Example of a condition the local government may consider reasonable—</heading><block><txt break.before="1">a condition that the work not be covered until the local government has inspected the work</txt></block></note></block></li><li id="sec.29B-ssec.4-para1.e" guid="_5de880e0-e385-4739-92d7-994f1b35893b" provision.type="other"><no>(e)</no><block><txt break.before="0">that a responsible person who is given a rectification notice must comply with the notice unless the person has a reasonable excuse;</txt></block></li><li id="sec.29B-ssec.4-para1.f" guid="_0005ed76-4691-45fe-81bb-d799b21fed18" provision.type="other"><no>(f)</no><block><txt break.before="0">that it is an offence to fail to comply with the notice unless the responsible person has a reasonable excuse.</txt></block></li></list></block></subclause><subclause id="sec.29B-ssec.5" guid="_2b3062a5-e707-42b8-8ce0-a359a127df82" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">A person who is given a rectification notice must comply with the notice unless the person has a reasonable excuse.</txt></block><penalty id="sec.29B-ssec.5-pen" guid="_fba2abe1-0fdb-4613-8383-f90d2f28195f"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.29B-ssec.6" guid="_399fadc6-b1d1-4325-9f18-f99a20887698" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">If the local government decides to give a rectification notice the local government must also give the responsible person an information notice about the decision.</txt></block></subclause><subclause id="sec.29B-ssec.7" guid="_760ebb13-748a-4a4c-b7e9-5fa7f4320d15" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">A decision to give a rectification notice is a decision under <legref jurisd="QLD" type="subordleg" refid="pt.4" target.doc.id="UNKNOWN" check="invalid">part&#160;4</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>.</txt><note id="sec.29B-ssec.7-note" guid="_95f0df72-a7bd-4563-9842-64e770c46708" type="example"><heading id="sec.29B-ssec.7-note-he" guid="_79cd572d-26f4-48c2-846b-02982fa1423c">Note—</heading><block><txt break.before="1">For appeals against the decision, see the Planning Act, <intref refid="ch.6" check="invalid">chapter&#160;6</intref>.</txt></block></note></block></subclause><subclause id="sec.29B-ssec.8" guid="_53bfa276-b863-406b-8ad9-e30dd993b203" affected.by.uncommenced="0" provision.type="other"><no>(8)</no><block><txt break.before="0"><intref refid="sec.29B-ssec.9" check="valid" target.guid="_b247b5d3-dc4f-47af-ab6c-8d020ba945fe">Subsection&#160;(9)</intref> applies if a licensed contractor directs or supervises the performance of the work mentioned in <intref refid="sec.29B-ssec.2" check="valid" target.guid="_2625b292-2c4d-4492-892d-fa2dbe014396">subsection&#160;(2)</intref>.</txt></block></subclause><subclause id="sec.29B-ssec.9" guid="_b247b5d3-dc4f-47af-ab6c-8d020ba945fe" affected.by.uncommenced="0" provision.type="other"><no>(9)</no><block><txt break.before="0">For the purposes of this section, the licensed contractor is taken to be a responsible person for the work regardless of whether the contractor is also a licensed person for the work.</txt></block></subclause><subclause id="sec.29B-ssec.10" guid="_0a8e89d3-e6af-4635-82df-a8bdd8e519d9" affected.by.uncommenced="0" provision.type="other"><no>(10)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.29B-ssec.10-def.contractorslicence_" guid="_137821f7-68d8-4663-ae58-88c33098c9b0" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.29B-ssec.10-def.contractorslicence" guid="_70094aa8-5399-4956-b70c-ddf6186c6b0a" type="definition">contractor’s licence</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref>, <legref jurisd="QLD" type="act" refid="sec.30" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid" target.guid="_224a557c-09c6-4d3a-951e-58a4bc2fc644">section&#160;30</legref><legref jurisd="QLD" type="act" refid="sec.30-ssec.1" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid" target.guid="_94853cc6-10ef-400e-80f6-b22736593953">(1)</legref>.</txt></definition><definition id="sec.29B-ssec.10-def.licensedcontractor_" guid="_9145831a-e422-46f0-8484-346d98da4fd7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.29B-ssec.10-def.licensedcontractor" guid="_d185d299-8a97-4883-8820-a6e9b5261d5b" type="definition">licensed contractor</defterm> means a person who holds a contractor’s licence issued under the <legref jurisd="QLD" type="act" target.doc.id="act-1991-098" target.version.series="b20a6ba1-d45a-4cf3-a1e3-8370a2766a12" check="valid"><name emphasis="yes">Queensland Building and Construction Commission Act 1991</name></legref>.</txt></definition><definition id="sec.29B-ssec.10-def.rectificationperiod_" guid="_741f3572-d08f-431a-a792-2dae9f2c8869" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.29B-ssec.10-def.rectificationperiod" guid="_7b132509-5cd6-4dab-b13f-dba0b9c71825" type="definition">rectification period</defterm>, for a rectification notice, means the following period within which the responsible person for notifiable work the subject of the rectification notice must comply with the rectification notice—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.29B-ssec.10-def.rectificationperiod-para1.a" guid="_6a7a014f-ed5c-4b6d-b3ed-38cb3a339b46" provision.type="other"><no>(a)</no><block><txt break.before="0">if the local government and the responsible person have agreed on a period within which the responsible person must comply with the rectification notice—the period agreed;</txt></block></li><li id="sec.29B-ssec.10-def.rectificationperiod-para1.b" guid="_96b20363-629d-4b2f-bbfe-88a6f57e9c45" provision.type="other"><no>(b)</no><block><txt break.before="0">otherwise—the period the local government allows that is at least 5 business days.</txt></block></li></list></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;29B</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.38" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;38</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.27" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;27</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0224" target.version.series="2752cfbe-6708-4b47-a7dd-94101665379e" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;224</legref> <legref jurisd="QLD" type="subordleg" refid="sec.43" target.doc.id="sl-2013-0224" valid.date="as.made" check="invalid">s&#160;43</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2014-0255" target.version.series="23fbb48d-2573-47da-a20e-802b6d9c2320" valid.date="as.made" check="valid">2014 SL&#160;No.&#160;255</legref> <legref jurisd="QLD" type="subordleg" refid="sec.17" target.doc.id="sl-2014-0255" valid.date="as.made" check="invalid">s&#160;17</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2017-0103" target.version.series="aabfcf9a-08e0-4b5f-9217-29d2cd8b8f45" valid.date="as.made" check="valid">2017 SL&#160;No.&#160;103</legref> <legref jurisd="QLD" type="subordleg" refid="sec.120" target.doc.id="sl-2017-0103" target.version.series="aabfcf9a-08e0-4b5f-9217-29d2cd8b8f45" valid.date="as.made" check="valid" target.guid="_a635e511-8419-4c57-ab9a-3f136d407767">s&#160;120</legref></txt></historynote></clause></division></part><part id="pt.4" guid="_d190df07-0552-49a9-9ac8-381a797377ba" affected.by.uncommenced="0"><no>Part 4</no><heading id="pt.4-he" guid="_cb14dd5b-107c-4e23-b03d-c6098762a7f3">Product certification</heading><clause id="sec.30" guid="_e0b0b229-88ef-4b36-8584-5a2751c78f82" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>30</no><heading id="sec.30-he" guid="_b48e1dfc-854f-4342-965d-1c8a355acd6b">Certified items to be used</heading><subclause id="sec.30-ssec.1" guid="_fab33119-818a-483c-9a86-70cbeb3982fd" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A person must not install or use a plumbing or drainage item in plumbing or drainage if the item is not a certified item.</txt></block><penalty id="sec.30-ssec.1-pen" guid="_5f0938e8-ae4d-40c6-9ee7-68f2e6bb283a"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.30-ssec.2" guid="_a1425d33-bb1a-4bcc-9974-2c14c3a33a15" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A person commits an offence under <intref refid="sec.30-ssec.1" check="valid" target.guid="_fab33119-818a-483c-9a86-70cbeb3982fd">subsection&#160;(1)</intref> for each plumbing or drainage item used or installed that is not a certified item.</txt></block></subclause><subclause id="sec.30-ssec.3" guid="_005ffa37-632a-4c7b-8987-5a75201c2fce" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">However, <intref refid="sec.30-ssec.1" check="valid" target.guid="_fab33119-818a-483c-9a86-70cbeb3982fd">subsection&#160;(1)</intref> does not apply to stop the continued use of a plumbing or drainage item—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.30-ssec.3-para1.a" guid="_40c5ad6e-15d8-4865-92ff-bca0931a7e20" provision.type="other"><no>(a)</no><block><txt break.before="0">in plumbing or drainage installed before the commencement of this section; or</txt></block></li><li id="sec.30-ssec.3-para1.b" guid="_d84bf1c4-c1cf-49c0-a1d6-937729f857cd" provision.type="other"><no>(b)</no><block><txt break.before="0">if the local government is satisfied that use of the item is necessary for maintaining the plumbing or drainage in its original form and approves the continued use of the item.</txt></block></li></list></block></subclause><subclause id="sec.30-ssec.4" guid="_32b734bd-360d-4510-81cf-4ccbfa4611b9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">For approving the continued use of a plumbing or drainage item under <intref refid="sec.30-ssec.3" check="valid" target.guid="_005ffa37-632a-4c7b-8987-5a75201c2fce">subsection&#160;(3)</intref><intref refid="sec.30-ssec.3-para1.b" check="valid" target.guid="_d84bf1c4-c1cf-49c0-a1d6-937729f857cd">(b)</intref>, the local government may require a person to have the item tested at the person’s cost within a stated reasonable time and at a stated reasonable place.</txt></block></subclause><subclause id="sec.30-ssec.5" guid="_936839e6-df2a-49d9-b8c3-9988de58b72d" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">This section is subject to <intref refid="sec.31" check="valid" target.guid="_6f438b8f-6792-4db7-8754-37c9a6c18e6b">section&#160;31</intref>.</txt></block></subclause></clause><clause id="sec.31" guid="_6f438b8f-6792-4db7-8754-37c9a6c18e6b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>31</no><heading id="sec.31-he" guid="_8906e1de-8494-4a15-aa54-e91ba3df3141">Non-certified items allowed for fire service</heading><subclause id="sec.31-ssec.1" guid="_cef2d1d7-6ab2-474f-a603-3ddc158f086b" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A person may install or use a plumbing or drainage item that is not a certified item if the item is—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.31-ssec.1-para1.a" guid="_4d4840f5-3a02-4a0a-af63-e431ba36ec52" provision.type="other"><no>(a)</no><block><txt break.before="0">part of a fire service that is installed and used solely for fire fighting; and</txt></block></li><li id="sec.31-ssec.1-para1.b" guid="_f066357a-7264-404f-83f0-f7acb8175077" provision.type="other"><no>(b)</no><block><txt break.before="0">if the fire service is connected to a water service provider’s infrastructure—installed downstream of a testable backflow prevention device; and</txt></block></li><li id="sec.31-ssec.1-para1.c" guid="_1a8fdbef-5d18-48b9-98f1-844abf9e41e5" provision.type="other"><no>(c)</no><block><txt break.before="0">tested in accordance with a specified test method endorsed by a JAS-ANZ certification body; and</txt></block></li><li id="sec.31-ssec.1-para1.d" guid="_733aa5e7-9a5d-4afb-b202-43524e64d4ec" provision.type="other"><no>(d)</no><block><txt break.before="0">listed for the specific use in a fire service by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.31-ssec.1-para1.d-para2.i" guid="_12afeb9d-161c-4fdd-961d-58806686abab" provision.type="other"><no>(i)</no><block><txt break.before="0">a nationally or internationally recognised body for testing and approving fire services; or</txt><note id="sec.31-ssec.1-para1.d-para2.i-note" guid="_90efd6d0-2ceb-4126-810f-caaabaf9ff65" type="example"><heading id="sec.31-ssec.1-para1.d-para2.i-note-he" guid="_f3564fa3-ca15-43e2-a2ac-977c6ce7d6c4">Examples—</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sec.31-ssec.1-para1.d-para2.i-note-para3.1" guid="_a7319cde-6ab7-49b0-96c3-692364131d4f" provision.type="other"><no>1</no><block><txt break.before="0">Scientific Services Laboratory</txt></block></li><li id="sec.31-ssec.1-para1.d-para2.i-note-para3.2" guid="_7c055664-e7a1-4f96-b6c3-94ed1b41f0b5" provision.type="other"><no>2</no><block><txt break.before="0">Underwriters Laboratories</txt></block></li><li id="sec.31-ssec.1-para1.d-para2.i-note-para3.3" guid="_6e2cad23-36ff-4a4f-9a6c-c21c5d798c51" provision.type="other"><no>3</no><block><txt break.before="0">Factory Mutual</txt></block></li><li id="sec.31-ssec.1-para1.d-para2.i-note-para3.4" guid="_563fbafa-f73a-42fd-a62c-e80dfbccee1a" provision.type="other"><no>4</no><block><txt break.before="0">Loss Prevention Council</txt></block></li></list></block></note></block></li><li id="sec.31-ssec.1-para1.d-para2.ii" guid="_74e51f9c-52e5-4e44-9dbc-8478504fa030" provision.type="other"><no>(ii)</no><block><txt break.before="0">a JAS-ANZ certification body; and</txt></block></li></list><note id="sec.31-ssec.1-para1.d-note" guid="_92977a37-fda8-423e-bc18-7c1f413f388f" type="example"><heading id="sec.31-ssec.1-para1.d-note-he" guid="_271c0b3d-3aad-459f-9781-ee39e04d3319">Example—</heading><block><txt break.before="1">A pipe listed for use in a fire sprinkler system is not suitable for use in a fire hydrant installation unless the pipe is also listed for that specific use.</txt></block></note></block></li><li id="sec.31-ssec.1-para1.e" guid="_de68b231-007d-485f-babb-264a018f8578" provision.type="other"><no>(e)</no><block><txt break.before="0">marked in accordance with a scheme endorsed by a JAS-ANZ certification body.</txt></block></li></list></block><penalty id="sec.31-ssec.1-pen" guid="_7e9ad8f6-7300-4487-af02-d2707ae55bef"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.31-ssec.2" guid="_9d628cac-b987-4fe7-9cb5-74834fb9070a" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A testable backflow prevention device mentioned in <intref refid="sec.31-ssec.1" check="valid" target.guid="_cef2d1d7-6ab2-474f-a603-3ddc158f086b">subsection&#160;(1)</intref><intref refid="sec.31-ssec.1-para1.b" check="valid" target.guid="_f066357a-7264-404f-83f0-f7acb8175077">(b)</intref> is not required to be a certified item if it is tested in accordance with the QPW code, <intref refid="pt.6" check="valid" target.guid="_6c123287-2bc9-4237-9af9-07ca10378871">part&#160;6</intref>.</txt></block></subclause><subclause id="sec.31-ssec.3" guid="_c85a080c-3e42-49e6-94fa-82da0f3bef1f" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.31-ssec.3-def.JASANZ_" guid="_bd8d5dbd-0d94-483e-b48a-8ac271ee789b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.31-ssec.3-def.JASANZ" guid="_8d1aab3c-bd89-4601-bf77-16631b8c6960" type="definition">JAS-ANZ</defterm> means the Joint Accreditation System of Australia and New Zealand that was declared under the <legref jurisd="CTH" type="act" check="invalid"><name emphasis="yes">Joint Accreditation System of Australia and New Zealand (Privileges and Immunities) Regulations 1998</name> (Cwlth)</legref> to be an international organisation to which the <legref jurisd="CTH" type="act" check="invalid"><name emphasis="yes">International Organisations (Privileges and Immunities) Act 1963</name> (Cwlth)</legref> applies.</txt></definition><definition id="sec.31-ssec.3-def.JASANZcertificationbody_" guid="_cccf3c95-d890-4af6-945f-9a9a5841f260" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.31-ssec.3-def.JASANZcertificationbody" guid="_1c7d7bc4-6a21-4cad-9b1d-a081b8dc7d09" type="definition">JAS-ANZ certification body</defterm> means a certification body registered by JAS-ANZ for providing product certification systems.</txt></definition><definition id="sec.31-ssec.3-def.testablebackflowpreventiondevice_" guid="_aaee9538-24d7-4b35-bd01-eb812bb0710e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.31-ssec.3-def.testablebackflowpreventiondevice" guid="_0aa9f141-21e1-4205-a429-b1a47fb7504b" type="definition">testable backflow prevention device</defterm> includes a testable single check valve.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;31</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2008-0375" target.version.series="bb1fc8da-25b3-4bf0-8bf3-eb3657151d25" valid.date="as.made" check="valid">2008 SL&#160;No.&#160;375</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2008-0375" valid.date="as.made" check="invalid">s&#160;5</legref></txt></historynote></clause><clause id="sec.32" guid="_e335286f-a78e-4f98-abea-8308e13e22e8" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>32</no><heading id="sec.32-he" guid="_7ca7fb24-22ba-4cb0-a263-3c63a488eb22">Unsuitable apparatus, fittings, materials and pipes</heading><block><txt break.before="1">If an inspector is satisfied that a plumbing or drainage item is unsuitable for use in particular circumstances, the local government may—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.32-para1.a" guid="_ddfc5993-40c6-439c-ad07-095489e2c3a0" provision.type="other"><no>(a)</no><block><txt break.before="0">require that the item is not installed or used in the circumstances; and</txt></block></li><li id="sec.32-para1.b" guid="_09a54d1c-dd20-4dfe-82bb-6677b1fe8dc6" provision.type="other"><no>(b)</no><block><txt break.before="0">approve the installation or use of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.32-para1.b-para2.i" guid="_47b02322-25fa-4ca6-b425-6efab285a1c0" provision.type="other"><no>(i)</no><block><txt break.before="0">the item, but with a protective coating, lining or wrapping for the item; or</txt></block></li><li id="sec.32-para1.b-para2.ii" guid="_71e6ee5f-34a6-4806-82f7-3fe7082f1a56" provision.type="other"><no>(ii)</no><block><txt break.before="0">another plumbing or drainage item.</txt></block></li></list></block></li></list><note id="sec.32-note" guid="_63ae71f2-e920-4f17-a9d7-b51d1bc4635d" type="example"><heading id="sec.32-note-he" guid="_dd27abff-0e25-4b6f-9b38-b258875d070c">Example of an unsuitable plumbing or drainage item—</heading><block><txt break.before="1">a polyethylene pipe installed below ground level if there are petrochemicals in the ground</txt></block></note></block><historynote><txt break.before="1"><b>s&#160;32</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.39" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;39</legref></txt></historynote></clause></part><part id="pt.5" guid="_85ba2cfb-3865-492a-a0d1-59b84e7ce3fb" affected.by.uncommenced="0"><no>Part 5</no><heading id="pt.5-he" guid="_f5f2ce45-9942-4978-9a2e-1f4c6d900bb2">Installations on premises</heading><division id="pt.5-div.1" guid="_97f01023-811d-4b06-9989-2ea8b2155ede" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.5-div.1-he" guid="_22e107a7-e622-40b0-a9ea-67e10470cfeb">Supply pipes and drains</heading><clause id="sec.33" guid="_d1c6ff86-eb05-4f34-a47d-18fb5bc27821" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>33</no><heading id="sec.33-he" guid="_71df9a19-8cc1-4156-b976-4b1883088aff">Disconnection of supply pipes and sanitary drains</heading><block><txt break.before="1">If a supply pipe or sanitary drain is no longer needed because an installation on premises is dismantled, the owner of the premises must take all reasonable steps to ensure that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.33-para1.a" guid="_2263ba8d-3d5d-4b84-9fa2-15170cd3dcb6" provision.type="other"><no>(a)</no><block><txt break.before="0">all apparatus and fittings are disconnected from the supply pipe or sanitary drain; and</txt></block></li><li id="sec.33-para1.b" guid="_bcebf4cf-ef61-457f-a05b-041c9f98bd60" provision.type="other"><no>(b)</no><block><txt break.before="0">each opening to the supply pipe or sanitary drain is sealed with a plug.</txt></block></li></list></block><penalty id="sec.33-pen" guid="_2ae696ef-1ff3-4260-8b23-106c1c672476"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty><note id="sec.33-note" guid="_2ce82335-d7c8-4b0e-9c1c-759a520f82d9" type="example"><heading id="sec.33-note-he" guid="_e1fbdb18-cdd3-46ac-a1cc-5cd9b19e5c9b">Note—</heading><block><txt break.before="1">See the <legref jurisd="QLD" type="act" target.doc.id="act-2008-034" target.version.series="9851f4e7-ed11-449d-9dcc-a56d9299d9cf" check="valid"><name emphasis="yes">Water Supply (Safety and Reliability) Act 2008</name></legref>, <legref jurisd="QLD" type="act" refid="sec.191" target.doc.id="act-2008-034" target.version.series="9851f4e7-ed11-449d-9dcc-a56d9299d9cf" check="valid" target.guid="_3b018ea3-2040-4136-904a-9a34e3caf710">section&#160;191</legref> (Connecting to or disconnecting from service provider’s infrastructure without approval) for the requirement that a person must not, without the written consent of a service provider, disconnect from the service provider’s infrastructure.</txt></block></note><historynote><txt break.before="1"><b>s&#160;33</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote></clause><clause id="sec.34" guid="_18529fed-9d78-4b16-aee2-e3a9c657cc7b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>34</no><heading id="sec.34-he" guid="_0e2fcea9-464b-4150-a6ef-e7599e459ae3">Building supply pipe to water main standard</heading><subclause id="sec.34-ssec.1" guid="_a5f471a1-3f04-4742-8c64-7e0e19cbd0f7" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a supply pipe for premises or a premises group is to be built and the local government believes on reasonable grounds that an ordinary supply pipe can not give an efficient water supply for the premises or premises group.</txt><note id="sec.34-ssec.1-note" guid="_276f6135-a987-4757-b8b0-ca69733084e8" type="example"><heading id="sec.34-ssec.1-note-he" guid="_1b5d1ebd-9166-49ed-995e-ead6abf5a1f2">Example—</heading><block><txt break.before="1">An ordinary supply pipe may not give an efficient water supply to the campus of a tertiary educational institution that contains various detached buildings requiring a water supply.</txt></block></note></block></subclause><subclause id="sec.34-ssec.2" guid="_1a947b44-db38-4afe-8e0c-a50e87249731" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For a supply pipe for premises, the local government may require—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.34-ssec.2-para1.a" guid="_f29f429e-c3c8-4044-a1f8-da0560e4f1be" provision.type="other"><no>(a)</no><block><txt break.before="0">part or all of the supply pipe (the <defterm id="sec.34-ssec.2-def.premisesmain" guid="_3e3b8c46-3998-49fa-9954-b6753822bda1" type="definition">premises main</defterm>) to be built to the standard of a water main; and</txt></block></li><li id="sec.34-ssec.2-para1.b" guid="_06796562-01b6-42c8-9ddb-2369dc4ebe04" provision.type="other"><no>(b)</no><block><txt break.before="0">the premises main to supply directly each separately occupied part of the premises; and</txt></block></li><li id="sec.34-ssec.2-para1.c" guid="_526566dc-3cfc-4d2a-898e-10f13b784622" provision.type="other"><no>(c)</no><block><txt break.before="0">the premises main to supply directly each fire service within the premises.</txt></block></li></list></block></subclause><subclause id="sec.34-ssec.3" guid="_6785550f-3d49-45d2-a5a9-f36b7f2d8edc" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">For a supply pipe for a premises group, the local government may require—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.34-ssec.3-para1.a" guid="_e320286f-6acf-499f-9248-76da71bc207a" provision.type="other"><no>(a)</no><block><txt break.before="0">a part of the supply pipe (the <defterm id="sec.34-ssec.3-def.premisesgroupmain" guid="_fb90799a-aeea-4af7-b82d-c15eeb76479d" type="definition">premises group main</defterm>) to be built, in the way and to the extent directed by the local government, to the standard of a water main; and</txt></block></li><li id="sec.34-ssec.3-para1.b" guid="_d36f2268-c414-47dc-b4c7-5db942c9c576" provision.type="other"><no>(b)</no><block><txt break.before="0">each separately occupied part of the premises group to be served directly by a supply pipe connected to the premises group main; and</txt></block></li><li id="sec.34-ssec.3-para1.c" guid="_f68e5744-3495-4348-bf15-169a8b897d7c" provision.type="other"><no>(c)</no><block><txt break.before="0">each separately occupied part of the premises group that is to have a fire service to be served directly by a fire service connected to the premises group main.</txt></block></li></list></block></subclause><subclause id="sec.34-ssec.4" guid="_f44b77e6-4679-4f27-a72b-a3fa676b0367" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">To remove any doubt, it is declared that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.34-ssec.4-para1.a" guid="_c72985b7-35ad-4ff9-ae3e-972c7a3b7d83" provision.type="other"><no>(a)</no><block><txt break.before="0">a private main is not the property of the local government or another service provider; and</txt></block></li><li id="sec.34-ssec.4-para1.b" guid="_da2d3540-59ea-452e-8295-788a7acc8d13" provision.type="other"><no>(b)</no><block><txt break.before="0">the local government or other service provider is not responsible for the maintenance of the private main downstream from the connection point for the private main.</txt></block></li></list></block></subclause><subclause id="sec.34-ssec.5" guid="_051926af-fda1-49d3-838c-f2e325d17488" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">A supply pipe or fire service connected as required under <intref refid="sec.34-ssec.2" check="valid" target.guid="_1a947b44-db38-4afe-8e0c-a50e87249731">subsection&#160;(2)</intref><intref refid="sec.34-ssec.2-para1.b" check="valid" target.guid="_06796562-01b6-42c8-9ddb-2369dc4ebe04">(b)</intref> or <intref refid="sec.34-ssec.2-para1.c" check="valid" target.guid="_526566dc-3cfc-4d2a-898e-10f13b784622">(c)</intref> or <intref refid="sec.34-ssec.3" check="valid" target.guid="_6785550f-3d49-45d2-a5a9-f36b7f2d8edc">(3)</intref><intref refid="sec.34-ssec.3-para1.b" check="valid" target.guid="_d36f2268-c414-47dc-b4c7-5db942c9c576">(b)</intref> or <intref refid="sec.34-ssec.3-para1.c" check="valid" target.guid="_f68e5744-3495-4348-bf15-169a8b897d7c">(c)</intref> must be fitted with an isolating valve.</txt></block></subclause><subclause id="sec.34-ssec.6" guid="_a78fdf27-7c32-45d6-8144-1ce5b61c7c15" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.34-ssec.6-def.premisesgroup_" guid="_39efec36-ea57-4516-b310-be5cbc5e86cc" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.34-ssec.6-def.premisesgroup" guid="_bb883b95-2ea9-4864-80a3-17dd4177500e" type="definition">premises group</defterm> includes a proposed premises group.</txt></definition><definition id="sec.34-ssec.6-def.privatemain_" guid="_cf0a3cd8-56da-4211-b77f-131e0db6899b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.34-ssec.6-def.privatemain" guid="_3083626b-ed90-4f9e-9bff-e797b850a6d5" type="definition">private main</defterm> means the premises main or the premises group main.</txt></definition></deflist></block></subclause></clause><clause id="sec.35" guid="_09dd34ca-939a-4edb-9e79-3f4acb6770b9" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>35</no><heading id="sec.35-he" guid="_72c13177-9404-45df-a5c6-32b4c2484ff9">Building sanitary drain to sewerage system standard</heading><subclause id="sec.35-ssec.1" guid="_0c74337e-5e72-4929-9877-9b2331c4214b" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if sanitary drainage for premises or a premises group is to be built and the local government believes on reasonable grounds that drainage alone can not give efficient drainage for the premises.</txt><note id="sec.35-ssec.1-note" guid="_84f542a4-8eb2-45ba-b411-f9e6899bcabb" type="example"><heading id="sec.35-ssec.1-note-he" guid="_87e49a20-a0c9-4c39-8274-f6a47853c707">Example—</heading><block><txt break.before="1">Drainage alone may not give an efficient drainage to the campus of a tertiary educational institution that contains various detached buildings required to be connected to drainage.</txt></block></note></block></subclause><subclause id="sec.35-ssec.2" guid="_ce3daa35-b61e-44d3-aaf2-b523c5aa2bc8" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">For sanitary drainage for premises, the local government may require the building of a sewer for the premises (the <defterm id="sec.35-def.premisessewer" guid="_e449c134-5c16-44f2-a5bd-16f05b5da7eb" type="definition">premises sewer</defterm>) that is to the standard of a sewer forming part of the local government’s or another service provider’s sewerage system.</txt></block></subclause><subclause id="sec.35-ssec.3" guid="_ee17c9fb-7cfe-42d2-9651-18c4373d7f60" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">For sanitary drainage for a premises group, the local government may require a sewer for the premises group (the <defterm id="sec.35-def.premisesgroupsewer" guid="_d0995d29-3bfb-41d3-9750-6b7201f6a281" type="definition">premises group sewer</defterm>) be built to the standard of a sewer forming part of the local government’s or another service provider’s sewerage system.</txt></block></subclause><subclause id="sec.35-ssec.4" guid="_3ec90acf-dcf1-4ca8-bb5e-65b3b269d5a9" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">To remove any doubt, it is declared that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.35-ssec.4-para1.a" guid="_49c81d75-7cde-4bd0-a4fa-470be4edc58b" provision.type="other"><no>(a)</no><block><txt break.before="0">a private sewer is not the property of the local government or another service provider; and</txt></block></li><li id="sec.35-ssec.4-para1.b" guid="_fa40dfe7-eb03-47ac-b613-5b2fb176b4cf" provision.type="other"><no>(b)</no><block><txt break.before="0">the local government or other service provider is not responsible for the maintenance of the private sewer downstream from the connection point for the private sewer.</txt></block></li></list></block></subclause><subclause id="sec.35-ssec.5" guid="_31377b76-d39f-4930-a1be-f8a31bc8fe09" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.35-ssec.5-def.privatesewer_" guid="_49542648-1303-4cb1-944e-493aefe27d98" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.35-ssec.5-def.privatesewer" guid="_f88ee879-d536-4944-99eb-d31b984a43dc" type="definition">private sewer</defterm> means the premises sewer or the premises group sewer.</txt></definition></deflist></block></subclause></clause></division><division id="pt.5-div.2" guid="_60c386dd-588d-412f-8764-6ba56990a475" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.5-div.2-he" guid="_b6c0f994-aa9d-4be5-81fa-96cd25ece30b">Backflow prevention devices</heading><clause id="sec.36" guid="_18a559e7-eb81-4de8-b9d0-30d08cae73d5" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>36</no><heading id="sec.36-he" guid="_c3dd65bd-09f8-40cd-b55a-fc35c739d9d6">Installing backflow prevention devices</heading><subclause id="sec.36-ssec.1" guid="_a0864c7f-cb3d-4388-9df5-eefc06cf864f" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An appropriate backflow prevention device must be installed on premises if pollution of the water supply on the premises or the water service provider’s water service to the premises has been, or could be, caused by the plumbing on the premises.</txt></block></subclause><subclause id="sec.36-ssec.2" guid="_d8b4da06-368f-4d9c-bc43-83634a4bfda6" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.36-ssec.2-def.appropriatebackflowpreventiondevice_" guid="_5b2f684c-4026-4b42-85ad-a3800c63abc1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.36-ssec.2-def.appropriatebackflowpreventiondevice" guid="_2f59925a-3bef-4c2e-9d99-edfc97d88895" type="definition">appropriate backflow prevention device</defterm> means a backflow prevention device that is specified for the particular circumstances under the applied provisions.</txt></definition></deflist></block></subclause></clause><clause id="sec.37" guid="_09c89e5c-f65e-4e06-8dcc-ea489a60949b" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>37</no><heading id="sec.37-he" guid="_fe527099-0b3a-4960-ad18-21aacdac794b">Inspection and testing of backflow prevention devices</heading><block><txt break.before="1">A person who, under <legref jurisd="QLD" type="subordleg" refid="sec.117" target.doc.id="UNKNOWN" check="invalid">section&#160;117</legref><legref jurisd="QLD" type="subordleg" refid="sec.117-ssec.2" target.doc.id="UNKNOWN" check="invalid">(2)</legref><legref jurisd="QLD" type="subordleg" refid="sec.117-ssec.2-para1.c" target.doc.id="UNKNOWN" check="invalid">(c)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, inspects or tests a backflow prevention device must, within 10 business days after inspecting or testing the device, give the local government written results of the inspection or test.</txt></block><penalty id="sec.37-pen" guid="_e86fd075-2951-4245-83ea-ead141459692"><block><txt break.before="1">Maximum penalty—10 penalty units.</txt></block></penalty></clause><clause id="sec.38" guid="_420969fe-cd19-49db-99ad-ca94c479fa79" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>38</no><heading id="sec.38-he" guid="_cfbe9f06-b1c7-419c-a3e4-4d7cbafd0d82">Testable backflow prevention devices</heading><subclause id="sec.38-ssec.1" guid="_9e5e1deb-2b64-48e4-94e1-4dd2a88e8452" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A local government must implement and maintain a program for its local government area for the registration, maintenance and testing of testable backflow prevention devices installed in the area.</txt></block></subclause><subclause id="sec.38-ssec.2" guid="_154711ef-5374-4442-853c-ed5716e3febb" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government, or an entity authorised by the local government, must keep a register of the testable backflow prevention devices.</txt></block></subclause><subclause id="sec.38-ssec.3" guid="_e6674237-77ab-42a6-b0fd-05999e550eaa" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An owner of an installed testable backflow prevention device must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.38-ssec.3-para1.a" guid="_f40cd8c7-6b04-44d3-9bde-6b49a613309e" provision.type="other"><no>(a)</no><block><txt break.before="0">register the device with the local government or entity; and</txt></block></li><li id="sec.38-ssec.3-para1.b" guid="_4f812599-cc35-42f2-8868-1f6fc8e8f010" provision.type="other"><no>(b)</no><block><txt break.before="0">at least once each year, have the device inspected or tested by a person who is licensed to do the work.</txt></block></li></list></block><penalty id="sec.38-ssec.3-pen" guid="_f5ab0a26-9559-416c-b53c-b68cf8d73806"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.38-ssec.4" guid="_ef38b743-3b77-449a-8bea-ee84181d953b" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">A person who inspects or tests a testable backflow prevention device must, within 10 business days after inspecting or testing the device, give the local government written results of the inspection or test in the approved form.</txt></block><penalty id="sec.38-ssec.4-pen" guid="_e3afb560-ea73-4f6f-8c3a-a55ddcdef058"><block><txt break.before="1">Maximum penalty—10 penalty units.</txt></block></penalty></subclause><historynote><txt break.before="1"><b>s&#160;38</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.39" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;39</legref></txt></historynote></clause></division><division id="pt.5-div.3" guid="_d99b462c-4618-4b23-b18d-2804ffdb00d4" affected.by.uncommenced="0"><no>Division 3</no><heading id="pt.5-div.3-he" guid="_531203e8-d905-4ef5-a8a1-a360363652c6">Arrestors</heading><clause id="sec.39" guid="_6547f248-a99f-4d4a-add7-6edbac458663" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>39</no><heading id="sec.39-he" guid="_19f68da3-7274-4911-8a71-d25f6ff7a434">Requirements for grease arrestors</heading><subclause id="sec.39-ssec.1" guid="_87d0e5c4-f833-401f-a0e7-139bab261562" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A grease arrestor on premises must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.39-ssec.1-para1.a" guid="_44aef672-a075-4c08-af5a-170f6824a368" provision.type="other"><no>(a)</no><block><txt break.before="0">be installed in an accessible position, preferably outside a building, and as close as practicable to the appliance or fixture the arrestor serves; and</txt></block></li><li id="sec.39-ssec.1-para1.b" guid="_c0a7047a-e23b-42b5-931d-77704715dc4c" provision.type="other"><no>(b)</no><block><txt break.before="0">have a childproof cover or, if it is in an area subject to motor vehicle traffic, a suitable heavy duty cover; and</txt></block></li><li id="sec.39-ssec.1-para1.c" guid="_cd321051-83c4-4056-9ece-f0c51ff71ec4" provision.type="other"><no>(c)</no><block><txt break.before="0">if the arrestor is installed inside a building and in an area used for food preparation—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.39-ssec.1-para1.c-para2.i" guid="_3106753d-6051-4388-9036-c4ca2b148990" provision.type="other"><no>(i)</no><block><txt break.before="0">have a cover that is airtight; and</txt></block></li><li id="sec.39-ssec.1-para1.c-para2.ii" guid="_bd7c19e5-680b-4487-8c76-36fde2df4a13" provision.type="other"><no>(ii)</no><block><txt break.before="0">have its arrestor chamber fitted with a vent of a size of at least 50mm; and</txt></block></li></list></block></li><li id="sec.39-ssec.1-para1.d" guid="_46c86b28-3b13-4c6b-aaf7-bd49717c73f5" provision.type="other"><no>(d)</no><block><txt break.before="0">have a capacity below the invert of the outlet of at least twice the total capacity of the appliances and fixtures connected to it or, if the local government requires a larger capacity for the arrestor, the larger capacity; and</txt></block></li><li id="sec.39-ssec.1-para1.e" guid="_4bbb6a64-7d23-4e1d-b578-374ac7594339" provision.type="other"><no>(e)</no><block><txt break.before="0">have inlet and outlet ventilation of the standard for sanitary plumbing.</txt></block></li></list></block></subclause><subclause id="sec.39-ssec.2" guid="_ce53d9a3-c50b-4855-8cac-6e13cd1d31f8" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The following must be fitted with a trap—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.39-ssec.2-para1.a" guid="_5122552e-0174-4970-86d0-07693e907c0a" provision.type="other"><no>(a)</no><block><txt break.before="0">an appliance or fixture discharging to the arrestor;</txt></block></li><li id="sec.39-ssec.2-para1.b" guid="_a54074c2-91cf-472a-814f-4e46527bd525" provision.type="other"><no>(b)</no><block><txt break.before="0">the arrestor outlet.</txt></block></li></list></block></subclause><subclause id="sec.39-ssec.3" guid="_55f61244-256e-4b16-9de0-cbcf2ca9cff1" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The size of the arrestor outlet must be at least 100mm.</txt></block></subclause><subclause id="sec.39-ssec.4" guid="_8d14bdad-eedf-4158-9b89-9bf61c77077f" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The clean-out point for the arrestor must be accessible.</txt></block></subclause><subclause id="sec.39-ssec.5" guid="_9e4ef051-dcf4-4431-93a5-3ca597a62650" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">The distance from the top of the arrestor to the outlet invert must be at least half the depth of the arrestor below the outlet invert.</txt></block></subclause><subclause id="sec.39-ssec.6" guid="_82342336-010c-40aa-8101-f308de84f9b0" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">The outlet invert level of the arrestor must be at least 50mm below the inlet invert level.</txt></block></subclause><subclause id="sec.39-ssec.7" guid="_97903042-e4b8-45df-83ed-c3dce1c5045f" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">Any outlet pipe from the arrestor must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.39-ssec.7-para1.a" guid="_ff1272f4-71f1-4335-aa4b-1294a4faedab" provision.type="other"><no>(a)</no><block><txt break.before="0">be of a diameter approved by the local government; and</txt></block></li><li id="sec.39-ssec.7-para1.b" guid="_c44fb72a-a038-497e-a5ec-c7c46e561d6a" provision.type="other"><no>(b)</no><block><txt break.before="0">have a cross-sectional area of at least the combined cross-sectional areas of the incoming waste pipe.</txt></block></li></list></block></subclause><subclause id="sec.39-ssec.8" guid="_e4a0a546-7a5f-45dc-9905-73c85d47e1b4" affected.by.uncommenced="0" provision.type="other"><no>(8)</no><block><txt break.before="0">The design and location of the ventilation for the arrestor must be as approved by the local government.</txt></block></subclause><subclause id="sec.39-ssec.9" guid="_30eb6754-1dee-4a2a-9fbb-7334da96213f" affected.by.uncommenced="0" provision.type="other"><no>(9)</no><block><txt break.before="0">In approving the design and location of the arrestor’s ventilation under <intref refid="sec.39-ssec.8" check="valid" target.guid="_e4a0a546-7a5f-45dc-9905-73c85d47e1b4">subsection&#160;(8)</intref>, the local government must have regard to the arrestor’s design and the location of trap water seals in the arrestor.</txt></block></subclause></clause><clause id="sec.40" guid="_faafc5cb-a09e-4373-8421-100c8851d10c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>40</no><heading id="sec.40-he" guid="_8270f709-b79a-4b5e-bf6e-fa412f29939e">Connection of appliances and fixtures to grease arrestors</heading><subclause id="sec.40-ssec.1" guid="_549c39f3-d236-47be-b370-8be346f4494e" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">If an appliance or fixture is connected to a grease arrestor in a way that complies with this section, the appliance or fixture is not required to be separately vented in the way required under the applied provisions.</txt></block></subclause><subclause id="sec.40-ssec.2" guid="_0e0ffefa-2f60-4c9a-ad4d-f62c5f5b13f5" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The connecting pipe must be as short and direct as possible but, if its size is 50mm or less, it must not be longer than 2.5m.</txt></block></subclause><subclause id="sec.40-ssec.3" guid="_99e412b0-5df5-4919-ab04-3542aee0d2a8" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the appliance or fixture is for collecting greasy discharges from floor areas, it must be connected to the inlet pipe of the arrestor in 1 of the following ways—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.40-ssec.3-para1.a" guid="_07db6e83-9bed-4b15-947c-a9b74e3fbb0e" provision.type="other"><no>(a)</no><block><txt break.before="0">separately and uninterrupted by a trap water seal or air gap;</txt></block></li><li id="sec.40-ssec.3-para1.b" guid="_a3783687-f8e8-47da-b3f0-8e9c2ef09f7c" provision.type="other"><no>(b)</no><block><txt break.before="0">in combination through a 100mm or larger pipe with an upstream vent.</txt></block></li></list></block></subclause></clause></division><division id="pt.5-div.4" guid="_8b54a1fe-d435-4f80-a89c-0dab9924854d" affected.by.uncommenced="0"><no>Division 4</no><heading id="pt.5-div.4-he" guid="_b43ca140-ac59-414f-98f4-5a71ca0ab6b2">Other installations for plumbing</heading><clause id="sec.41" guid="_dbf596dc-44ea-4b07-9b2c-2090513e6de6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>41</no><heading id="sec.41-he" guid="_f5914dc4-e428-41d2-84d1-6eb634b751b1">Air cooling equipment</heading><subclause id="sec.41-ssec.1" guid="_293a3227-5f84-4e1e-a03b-7b0ad3fe8387" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Air cooling equipment may be connected to a supply pipe only if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.41-ssec.1-para1.a" guid="_a209f94e-8bd0-4734-85ae-ffa58228b8a3" provision.type="other"><no>(a)</no><block><txt break.before="0">the local government has approved the connection; and</txt></block></li><li id="sec.41-ssec.1-para1.b" guid="_f02ed6be-e541-42c5-a659-62f3cf7d2cb0" provision.type="other"><no>(b)</no><block><txt break.before="0">the equipment is fitted with the means of recovering and recycling water or with a backflow prevention device that is suitable for the purpose.</txt></block></li></list></block></subclause><subclause id="sec.41-ssec.2" guid="_aac0f200-a75c-411c-83ea-9e0c924c6ec8" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0"><intref refid="sec.41-ssec.1" check="valid" target.guid="_293a3227-5f84-4e1e-a03b-7b0ad3fe8387">Subsection&#160;(1)</intref> does not apply to air cooling equipment if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.41-ssec.2-para1.a" guid="_a044c258-021e-4b24-8c98-a210a7a580a8" provision.type="other"><no>(a)</no><block><txt break.before="0">the air cooling equipment is in the form of a domestic evaporative air conditioner; and</txt></block></li><li id="sec.41-ssec.2-para1.b" guid="_f2d1d866-eaf1-4bda-9d5b-06036f3f5959" provision.type="other"><no>(b)</no><block><txt break.before="0">the local government has approved the connection and use of the equipment.</txt></block></li></list></block></subclause><subclause id="sec.41-ssec.3" guid="_f82304aa-074b-490f-8cd7-d9f48e4f70af" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government may give an approval under <intref refid="sec.41-ssec.2" check="valid" target.guid="_aac0f200-a75c-411c-83ea-9e0c924c6ec8">subsection&#160;(2)</intref> only if the local government is satisfied that it is reasonable in the circumstances to allow the equipment’s use.</txt></block></subclause></clause><clause id="sec.42" guid="_8171b40c-9fd1-4947-b50b-ce7f7b1f211e" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>42</no><heading id="sec.42-he" guid="_c1c49e4c-b92f-42fe-ae2c-ec1cc289679d">Engines</heading><block><txt break.before="1">Water must not be supplied to an engine directly from a supply pipe.</txt></block></clause><clause id="sec.43" guid="_156ce60e-477d-44db-844c-0ca064ca03ef" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>43</no><heading id="sec.43-he" guid="_152fd95c-9722-49a1-b0c1-63b628c71691">Fire services</heading><block><txt break.before="1">A fire service must not be extended other than for a fire service purpose.</txt></block></clause><clause id="sec.44" guid="_328eaa33-5d97-4534-9004-81fbe12d5f55" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>44</no><heading id="sec.44-he" guid="_099ceeb3-5e12-4561-8695-d6cbffc73311">Hydraulic powered equipment</heading><subclause id="sec.44-ssec.1" guid="_537f0909-090f-4658-bf64-d85d68a784e9" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">Hydraulic powered equipment may be connected to a supply pipe only if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.44-ssec.1-para1.a" guid="_3c44d871-c329-4d31-b73b-6a6aec93725a" provision.type="other"><no>(a)</no><block><txt break.before="0">the local government has approved the connection; and</txt></block></li><li id="sec.44-ssec.1-para1.b" guid="_44dd05fc-b937-4d80-bffe-32cdb9b4c7c1" provision.type="other"><no>(b)</no><block><txt break.before="0">the equipment is fitted with the means of recovering and recycling water or with a backflow prevention device that is suitable for the purpose.</txt></block></li></list></block></subclause><subclause id="sec.44-ssec.2" guid="_3c2de80b-8adb-4767-ae53-998305a64faf" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0"><intref refid="sec.44-ssec.1" check="valid" target.guid="_537f0909-090f-4658-bf64-d85d68a784e9">Subsection&#160;(1)</intref> does not apply to hydraulic powered equipment if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.44-ssec.2-para1.a" guid="_103471d0-c2be-4ca9-b6cd-cac21b868a63" provision.type="other"><no>(a)</no><block><txt break.before="0">the hydraulic powered equipment is in the form of a domestic water lift; and</txt></block></li><li id="sec.44-ssec.2-para1.b" guid="_45664d17-551c-432b-83cf-69eca0f64a67" provision.type="other"><no>(b)</no><block><txt break.before="0">the local government has approved the connection and use, on premises occupied by a disabled person, of the equipment.</txt></block></li></list></block></subclause><subclause id="sec.44-ssec.3" guid="_a85d0796-616d-4aef-859a-b67fe32a82e3" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government may give an approval under <intref refid="sec.44-ssec.2" check="valid" target.guid="_3c2de80b-8adb-4767-ae53-998305a64faf">subsection&#160;(2)</intref> only if the local government is satisfied there is no other practical or economic way of giving mobility to the disabled person.</txt></block></subclause><subclause id="sec.44-ssec.4" guid="_c04bc65b-58a9-4212-b8fb-13ac1063d360" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.44-ssec.4-def.hydraulicpoweredequipment_" guid="_2352cb09-8979-4b78-af37-f350951b7eff" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.44-ssec.4-def.hydraulicpoweredequipment" guid="_a18c2c25-c8e1-4a28-91a5-bca2d510e06b" type="definition">hydraulic powered equipment</defterm> means plant, apparatus or machinery using water supply for hydraulic power.</txt></definition></deflist></block></subclause></clause><clause id="sec.45" guid="_47ecae4e-b451-4fe0-965e-73bbbd43752a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>45</no><heading id="sec.45-he" guid="_233ac512-701b-406f-a46f-560fd8908648">Water storage tanks</heading><subclause id="sec.45-ssec.1" guid="_a972df00-b815-486b-b4aa-392280f90c96" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A pipe carrying water supplied by the local government or other service provider must not, without a local government’s written approval—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.45-ssec.1-para1.a" guid="_9b741a86-6950-408b-8911-8bf80bda8afb" provision.type="other"><no>(a)</no><block><txt break.before="0">be connected to a water storage tank used to store water obtained from another source; or</txt></block></li><li id="sec.45-ssec.1-para1.b" guid="_013acaa1-4809-4cd0-a7fe-3f18d81745a9" provision.type="other"><no>(b)</no><block><txt break.before="0">be discharged into a water storage tank used to store water obtained from another source.</txt></block></li></list></block></subclause><subclause id="sec.45-ssec.2" guid="_1ba5a83f-0a3e-4ed7-ac48-fa480955a176" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the local government gives an approval under <intref refid="sec.45-ssec.1" check="valid" target.guid="_a972df00-b815-486b-b4aa-392280f90c96">subsection&#160;(1)</intref>, a backflow prevention device must be installed on the pipe carrying the water supplied by the local government.</txt></block></subclause></clause></division><division id="pt.5-div.5" guid="_52088116-c080-4147-822a-491da7b0e4ca" affected.by.uncommenced="0"><no>Division 5</no><heading id="pt.5-div.5-he" guid="_ac3eb032-4fac-4404-b23d-dde169813b08">Other installations for drainage</heading><clause id="sec.46" guid="_1d206031-f1f9-4825-a7f5-9c48ea17d981" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>46</no><heading id="sec.46-he" guid="_5b884f25-61a1-4190-a353-1eed87324476">Bedpan washers and sanitisers</heading><subclause id="sec.46-ssec.1" guid="_1a837854-d795-4ab0-8d48-594ed0d24bb4" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A pressurised steam bedpan washer installed and used on premises must, to the extent that it is reasonably practicable, comply with this section.</txt></block></subclause><subclause id="sec.46-ssec.2" guid="_6294f5f2-0ed5-4dd3-bb96-344f513fd26d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The washer must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.46-ssec.2-para1.a" guid="_476f17ad-ab27-4de2-817b-b4c9890af0e1" provision.type="other"><no>(a)</no><block><txt break.before="0">be directly connected to a drain or soil stack; and</txt></block></li><li id="sec.46-ssec.2-para1.b" guid="_7e3e84d9-45ae-4319-a9ae-9040f7178072" provision.type="other"><no>(b)</no><block><txt break.before="0">have its own steam relief vent or another way of relieving pressure in the washer to prevent traps blowing if the pressure rises above 0.35kPa.</txt></block></li></list></block></subclause><subclause id="sec.46-ssec.3" guid="_0d510ab2-d8c8-42d3-ada8-a7cd4515b219" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Soil stacks, soil pipe vents and steam relief vents for the washer must not be made from thermoplastic pipe.</txt></block></subclause><subclause id="sec.46-ssec.4" guid="_dc97d76d-74e1-4f8c-be8f-f8b9098992aa" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">A steam relief vent for the washer must have a size of at least 40mm and end above the roof of the building it is in.</txt></block></subclause><subclause id="sec.46-ssec.5" guid="_9346ba7a-b61a-4c76-b23c-ae6defeaf19f" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">A branch steam relief vent for the washer must be graded downwards at its point of connection to the main steam relief vent for the washer to give an invert fall equal to half the branch steam relief vent’s diameter.</txt></block></subclause><subclause id="sec.46-ssec.6" guid="_2810263e-4a2c-4d71-afeb-0c7045c2c0dc" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">The main steam relief vent for the washer must discharge condensate to a sanitary drain by—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.46-ssec.6-para1.a" guid="_aa296841-a75b-4e65-822d-73d8574becea" provision.type="other"><no>(a)</no><block><txt break.before="0">connection to a disconnector gully; or</txt></block></li><li id="sec.46-ssec.6-para1.b" guid="_e6c4935c-680c-4355-b785-cad23fd0442d" provision.type="other"><no>(b)</no><block><txt break.before="0">if there is 1 other bedpan washer, or if there are 2 or more other bedpan washers, on the premises and all are connected—the interconnection of the base of the main steam relief vent to the fixture trap riser of the lower or lowest of all the connected bedpan washers.</txt></block></li></list></block></subclause><subclause id="sec.46-ssec.7" guid="_1a1393f4-2691-4045-84ce-b6a1defae0e5" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">The points of connection to the main steam relief vent must be at least 300mm above the washers if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.46-ssec.7-para1.a" guid="_707546b5-0384-42a2-8565-bde3f1c13b27" provision.type="other"><no>(a)</no><block><txt break.before="0">there are 2 or more bedpan washers on the premises; and</txt></block></li><li id="sec.46-ssec.7-para1.b" guid="_b4b0afc4-554f-4208-a1c3-80ff758bc1f1" provision.type="other"><no>(b)</no><block><txt break.before="0">the steam relief vents from the washers are interconnected.</txt></block></li></list></block></subclause></clause><clause id="sec.47" guid="_3c9ed7bb-4baa-40b0-844d-fb740325e570" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>47</no><heading id="sec.47-he" guid="_4281b681-8472-42d2-ba1d-de6175d023a4">Fixtures in basements and cellars</heading><subclause id="sec.47-ssec.1" guid="_853f3f9a-351c-41f2-847b-994f3a145717" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A water closet pan, urinal or another fixture must not be installed in a part of premises below the level of the sewer or on-site sewerage facility for the premises unless the local government’s approval has been obtained for the installation.</txt></block></subclause><subclause id="sec.47-ssec.2" guid="_5334b4ae-dfcd-420b-93be-00b1e27e6e2b" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may give an approval under <intref refid="sec.47-ssec.1" check="valid" target.guid="_853f3f9a-351c-41f2-847b-994f3a145717">subsection&#160;(1)</intref> only if it is satisfied on reasonable grounds that there is adequate provision for lifting waste water to the sewer or on-site sewerage facility and preventing sewage flowing back into the room.</txt></block></subclause></clause><clause id="sec.48" guid="_96f613ac-c52b-49c9-8fec-c179314b1765" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>48</no><heading id="sec.48-he" guid="_6b830b45-7312-43fd-9d1e-aa38217ca342">Floor type urinals</heading><subclause id="sec.48-ssec.1" guid="_b726b179-d565-496f-addc-9a05475284bf" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A floor type urinal must not be installed if the urinal, or the way the urinal is installed, does not comply with this section.</txt></block></subclause><subclause id="sec.48-ssec.2" guid="_3647e9d2-b776-419a-9215-254669a2c6fa" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the floor near the urinal is exposed to rainwater, sand, mud or anything else that may enter the urinal channel, the urinal must have a step in front of the channel.</txt></block></subclause><subclause id="sec.48-ssec.3" guid="_a39c1342-3356-45fb-95f4-2872012fc88d" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The step must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.48-ssec.3-para1.a" guid="_068ee59b-fe0c-47c3-8b76-4361728b5106" provision.type="other"><no>(a)</no><block><txt break.before="0">be at least 400mm wide, measured from the inside face of the urinal channel; and</txt></block></li><li id="sec.48-ssec.3-para1.b" guid="_ecb9d1a2-43ff-4fcd-afa2-adb24cd76a65" provision.type="other"><no>(b)</no><block><txt break.before="0">have a tread of an impervious material graded to the urinal channel; and</txt></block></li><li id="sec.48-ssec.3-para1.c" guid="_8f72a0aa-9485-44db-883b-8dffc42d9589" provision.type="other"><no>(c)</no><block><txt break.before="0">have a rise of at least 100mm but not more than 150mm.</txt></block></li></list></block></subclause><subclause id="sec.48-ssec.4" guid="_2bc2ea7e-8edf-48be-b286-3e45f4e76325" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The level of the floor or tread must be at least 25mm above the top of the urinal channel and the joint between the step and the urinal channel must be sealed with a flexible caulking compound.</txt></block></subclause></clause><clause id="sec.49" guid="_52c234d5-ca0b-4560-a6ce-18a5ceeb0dcd" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>49</no><heading id="sec.49-he" guid="_77b28122-62d4-438e-ab03-32286a5c8dde">Flushing bowl and pan room sinks</heading><subclause id="sec.49-ssec.1" guid="_eac784d3-95a2-466b-a54b-719981f1abaf" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A flushing bowl or pan room sink must not be installed if the bowl or sink, or the way the bowl or sink is installed, does not comply with this section.</txt></block></subclause><subclause id="sec.49-ssec.2" guid="_54f739e4-2325-4497-b7a9-93704b829bde" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A flushing bowl must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.49-ssec.2-para1.a" guid="_c87274df-b499-4849-9a96-ba1907ac93a9" provision.type="other"><no>(a)</no><block><txt break.before="0">have an integral trap of at least 80mm and a flushing apparatus; and</txt></block></li><li id="sec.49-ssec.2-para1.b" guid="_bb27a588-bc8c-4c10-ac54-204d7b66dd0b" provision.type="other"><no>(b)</no><block><txt break.before="0">be directly connected to a sanitary drain or soil stack.</txt></block></li></list></block></subclause><subclause id="sec.49-ssec.3" guid="_10805641-977b-4aee-a229-43a39b74e99e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The waste pipe from the trap of a pan room sink may be connected to a vertical soil pipe from a flushing bowl trap only if the waste pipe is vented by a pipe of at least 50mm connected between the sink and the flushing bowl.</txt></block></subclause><subclause id="sec.49-ssec.4" guid="_9869fea8-9cd1-46b9-88b2-37413b184263" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If there are 2 pan room sinks installed, and the waste pipes from the traps of the 2 sinks are connected to the vertical soil pipe from a flushing bowl trap, the vent must be connected between the sink outlets.</txt></block></subclause><subclause id="sec.49-ssec.5" guid="_41248bd4-9f1a-4ac6-ba69-ef30f3f5f9ad" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">A pan room sink must connect directly to a drain or soil stack through traps and waste pipes of a size of at least 50mm.</txt></block></subclause></clause><clause id="sec.50" guid="_c196254b-03f0-493b-af87-3a4c8bfdfd29" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>50</no><heading id="sec.50-he" guid="_cbb23763-b0f1-4777-a703-9e5a2d08945e">Urinal installations</heading><subclause id="sec.50-ssec.1" guid="_6785f477-170c-49a4-bd0c-fba1aa39fe5f" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A prefabricated urinal must not be installed if the urinal, or the way the urinal is installed, does not comply with this section.</txt></block></subclause><subclause id="sec.50-ssec.2" guid="_5c508c5c-9f15-4472-a07f-456c6b6bdee9" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The floor of the compartment or room containing the urinal must drain to a floor waste gully or the urinal channel, or directly through a trap to a sanitary drain or soil stack.</txt></block></subclause><subclause id="sec.50-ssec.3" guid="_c053746c-a099-45cf-91e6-6ec6d9ed6979" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">If the urinal is a slab urinal, it must—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.50-ssec.3-para1.a" guid="_f921e725-f10c-4283-a586-6d3fa7720d93" provision.type="other"><no>(a)</no><block><txt break.before="0">have a continuous channel at least 50mm deep and 150mm wide; and</txt></block></li><li id="sec.50-ssec.3-para1.b" guid="_e326dbea-83a1-431c-8094-895ce95b63ad" provision.type="other"><no>(b)</no><block><txt break.before="0">be graded at least 1:100 to the outlets.</txt></block></li></list></block></subclause><subclause id="sec.50-ssec.4" guid="_a2b991d4-6a8d-4cd8-99d1-93850808c10f" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">If the urinal is a floor type urinal, the height of the slab above the top of the channel must be at least 960mm.</txt></block></subclause><subclause id="sec.50-ssec.5" guid="_37b367f7-cfcb-499e-b3a5-8b4dee1c313b" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">Edges and corners of urinal fixtures must be smoothly rounded to a radius of at least 13mm and the ends of the slab must return at least 250mm.</txt></block></subclause></clause><clause id="sec.50A" guid="_b1709bb7-de79-469b-b403-6c5355a2b451" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>50A</no><heading id="sec.50A-he" guid="_2b8a4cef-deb8-49e6-a3e8-2efe66c606f4">Integrated basins and water closet (WC) cisterns</heading><subclause id="sec.50A-ssec.1" guid="_39c747b0-349c-4ebe-aff9-88f885ee8ae2" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">An integrated system must not be installed if the integrated system, or the way the integrated system is installed, does not comply with this section.</txt></block></subclause><subclause id="sec.50A-ssec.2" guid="_9b6404b6-2d99-4e78-9254-0c5730da8181" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">An integrated system may only be installed in a building classified under BCA as a class 1a, 2 or 4 building.</txt></block></subclause><subclause id="sec.50A-ssec.3" guid="_8a12de9f-2c87-4914-b329-be08d4a91491" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">Water supplied to the integrated system must be—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.50A-ssec.3-para1.a" guid="_7c0ae381-22fc-461f-980f-ab269c79d33b" provision.type="other"><no>(a)</no><block><txt break.before="0">potable water or rainwater; and</txt></block></li><li id="sec.50A-ssec.3-para1.b" guid="_3dcf75f7-5e82-4a4b-a5d4-0136ee39b295" provision.type="other"><no>(b)</no><block><txt break.before="0">supplied to the basin directly from the system tap when the toilet is flushed.</txt></block></li></list></block></subclause><subclause id="sec.50A-ssec.4" guid="_a021ec89-6909-4424-9f0e-da9d0444ca9b" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">The basin must be attached to the top of the water closet (WC) cistern.</txt></block></subclause><subclause id="sec.50A-ssec.5" guid="_ca70fb39-beac-4f60-8f66-c967b6bce08b" affected.by.uncommenced="0" provision.type="other"><no>(5)</no><block><txt break.before="0">Water from the basin must be discharged directly into the water closet (WC) cistern.</txt></block></subclause><subclause id="sec.50A-ssec.6" guid="_abf3f6fe-a109-4f5b-903c-dd05eb6ba1cd" affected.by.uncommenced="0" provision.type="other"><no>(6)</no><block><txt break.before="0">Water from the water closet (WC) cistern must be discharged into a sanitary drain through the toilet pan.</txt></block></subclause><subclause id="sec.50A-ssec.7" guid="_0597cbfe-d242-4ac4-9750-d7ab79862756" affected.by.uncommenced="0" provision.type="other"><no>(7)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.50A-ssec.7-def.integratedsystem_" guid="_f806ab8b-80b8-4dad-9a2a-1e61e8cb544c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.50A-ssec.7-def.integratedsystem" guid="_6af89329-46bd-472b-96b9-c241ba983cc4" type="definition">integrated system</defterm> means a toilet that has, as an integral part, a basin that discharges greywater from the basin directly into the water closet (WC) cistern.</txt></definition><definition id="sec.50A-ssec.7-def.systemtap_" guid="_95e97802-3f3d-40a3-9df8-cdc4ebd8ab2b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.50A-ssec.7-def.systemtap" guid="_3baa0814-e77a-4af7-a95b-7284dde3bc4e" type="definition">system tap</defterm> means a tap connected to a supply pipe that supplies water to the integrated system.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;50A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0134" target.version.series="bff83d04-f292-4dfc-8b99-2d22ba04aef9" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;134</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2011-0134" valid.date="as.made" check="invalid">s&#160;6</legref></txt></historynote></clause><clause id="sec.51" guid="_d66aac50-0768-4c77-9d95-40d81090a205" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>51</no><heading id="sec.51-he" guid="_ee57dfa0-6e87-433b-9f65-66b7d9383df3">Vent pipes to be covered</heading><subclause id="sec.51-ssec.1" guid="_c4ebb12b-d2d6-4c73-ab08-da5bc57986ed" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">A vent pipe must have a cowl over the end of the vent pipe that has the same effective ventilation capacity as the vent pipe.</txt></block></subclause><subclause id="sec.51-ssec.2" guid="_248434fd-b43d-436e-8552-6aa4097b5448" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the pipe is connected to an on-site sewerage facility, the cowl must be a mosquito proof type of cowl.</txt></block></subclause></clause><clause id="sec.52" guid="_6511c41a-e0f9-4bda-9a3e-e86cb8780f6a" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>52</no><heading id="sec.52-he" guid="_20a3b335-62ad-42e4-93bd-8e33ae73aca2">Vents in adjoining buildings</heading><subclause id="sec.52-ssec.1" guid="_30340bb7-66f9-4707-934f-e17739439c9d" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if a building (the <defterm id="sec.52-def.newbuilding" guid="_79aea433-e377-4498-b6c2-019c5b28a534" type="definition">new building</defterm>) is erected next to a building of a lower height (the <defterm id="sec.52-def.oldbuilding" guid="_8b974a7f-bdbd-4bd4-b13a-da78af59b81b" type="definition">old building</defterm>) in a way requiring a change to the vents of the old building to comply with requirements about vents included in the applied provisions.</txt></block></subclause><subclause id="sec.52-ssec.2" guid="_578df005-6c0f-44e0-9e95-31da8508a44d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The local government may, by written notice given to the owner of the new building and the owner of the old building, require that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.52-ssec.2-para1.a" guid="_53f6ae46-4856-4e4d-b16a-e8a0983eeda4" provision.type="other"><no>(a)</no><block><txt break.before="0">the new building’s owner pay the reasonable cost of changing the vents on the old building; and</txt></block></li><li id="sec.52-ssec.2-para1.b" guid="_90100c79-970c-4988-96b4-07d4428ad977" provision.type="other"><no>(b)</no><block><txt break.before="0">the old building’s owner change the vents.</txt></block></li></list></block></subclause><subclause id="sec.52-ssec.3" guid="_f53bd36c-0af0-4d9f-ada5-069269788f45" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">An owner given written notice under <intref refid="sec.52-ssec.2" check="valid" target.guid="_578df005-6c0f-44e0-9e95-31da8508a44d">subsection&#160;(2)</intref> must comply with the notice.</txt></block><penalty id="sec.52-ssec.3-pen" guid="_d4584b66-d21a-4b06-8a4c-69eeeaa2c371"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><subclause id="sec.52-ssec.4" guid="_fd130f66-483c-4492-a9c3-f2915133602a" affected.by.uncommenced="0" provision.type="other"><no>(4)</no><block><txt break.before="0">However, the owner of the old building is not required to change the vents until the new building’s owner—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.52-ssec.4-para1.a" guid="_4362a21a-e90c-4e8a-a35c-a735fed553a3" provision.type="other"><no>(a)</no><block><txt break.before="0">pays the old building’s owner the reasonable cost of changing the vents on the old building; or</txt></block></li><li id="sec.52-ssec.4-para1.b" guid="_bf681f16-a775-41e5-af4b-fe32b9e5250f" provision.type="other"><no>(b)</no><block><txt break.before="0">gives the old building’s owner security, to the satisfaction of the old building’s owner, for the cost of changing the vents.</txt></block></li></list></block></subclause></clause></division></part><part id="pt.6" guid="_6c123287-2bc9-4237-9af9-07ca10378871" affected.by.uncommenced="0"><no>Part 6</no><heading id="pt.6-he" guid="_31eae46c-e11a-4f37-9e18-5ea9b6a156c0">Appointment of inspectors</heading><clause id="sec.53" guid="_2757796d-9ee7-4427-8d78-5e5d9e91a56f" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>53</no><heading id="sec.53-he" guid="_74a5729b-80d7-4806-8d66-47c3aa60c74c">Qualifications and experience</heading><subclause id="sec.53-ssec.1" guid="_d49b619d-ada0-449e-adc9-51de195b4b53" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section prescribes, for <legref jurisd="QLD" type="subordleg" refid="sec.107" target.doc.id="UNKNOWN" check="invalid">section&#160;107</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref>, the qualifications and experience an individual must have to be qualified for appointment as an inspector.</txt></block></subclause><subclause id="sec.53-ssec.2" guid="_9a852bdf-33e7-4603-af2e-95094715277d" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">If the individual is to assess plumbing and drainage work, the individual must have the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.a" guid="_e5142d27-7254-43ec-b884-c2590ed36b05" provision.type="other"><no>(a)</no><block><txt break.before="0">the qualifications, skills and experience that, in the opinion of the local government appointing the individual, gives the individual the necessary competence for assessing plumbing and drainage work;</txt></block></li><li id="sec.53-ssec.2-para1.b" guid="_723a0972-2135-437d-bf03-71134742c8f8" provision.type="other"><no>(b)</no><block><txt break.before="0">either—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.2-para1.b-para2.i" guid="_038f9369-0445-448a-a885-528cc87b15c3" provision.type="other"><no>(i)</no><block><txt break.before="0">a plumbers licence and a drainers licence; or</txt></block></li><li id="sec.53-ssec.2-para1.b-para2.ii" guid="_b11035c4-53ba-4c21-b92b-efbdf34f132e" provision.type="other"><no>(ii)</no><block><txt break.before="0">a qualification that the QBCC commissioner decides, or has decided, gives the individual the necessary competence for assessing plumbing and drainage work.</txt></block></li></list></block></li></list></block></subclause><subclause id="sec.53-ssec.3" guid="_ebb89438-5d53-4db3-ad78-09e574855b8e" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">On and from 1 November 2006, if the individual is to assess on-site sewerage facilities, the individual must have the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.3-para1.a" guid="_ce0c9e6b-fff5-498a-9c48-9b70643ac3f0" provision.type="other"><no>(a)</no><block><txt break.before="0">the qualifications, skills and experience that, in the opinion of the local government appointing the individual, gives the individual the necessary competence for inspecting and approving on-site sewerage facilities;</txt></block></li><li id="sec.53-ssec.3-para1.b" guid="_76405ef6-64f9-4574-bc39-55ad5a1efd13" provision.type="other"><no>(b)</no><block><txt break.before="0">either—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.53-ssec.3-para1.b-para2.i" guid="_18c5d512-c592-4599-b573-f815008a4d93" provision.type="other"><no>(i)</no><block><txt break.before="0">a drainers licence with an endorsement for on-site sewerage facility maintenance; or</txt><note id="sec.53-ssec.3-para1.b-para2.i-note" guid="_d28d6b8a-41e9-48c8-b2a3-f7181eb5d65b" type="example"><heading id="sec.53-ssec.3-para1.b-para2.i-note-he" guid="_0ac38933-438b-434d-960e-dd97a5da039f">Note—</heading><block><txt break.before="1">See the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2003-0266" target.version.series="22beab68-19fc-49f7-94e9-1456c1bae50a" check="valid"><name emphasis="yes">Plumbing and Drainage Regulation 2003</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.3" target.doc.id="sl-2003-0266" target.version.series="22beab68-19fc-49f7-94e9-1456c1bae50a" check="valid" target.guid="_d71062ca-df2a-44fb-b4d3-d8914d7d0b7f">schedule&#160;3</legref> (Qualifications, practical experience and scope of work for endorsements), item 3.</txt></block></note></block></li><li id="sec.53-ssec.3-para1.b-para2.ii" guid="_bdfc0b1e-cc0a-478e-9666-1bb0e4457704" provision.type="other"><no>(ii)</no><block><txt break.before="0">a restricted licence for a drainer—on-site sewerage facility; or</txt><note id="sec.53-ssec.3-para1.b-para2.ii-note" guid="_7b0c9ccc-0742-4966-96ad-a2c82a04ffb9" type="example"><heading id="sec.53-ssec.3-para1.b-para2.ii-note-he" guid="_1e00b8d9-3b10-432c-a82a-3b245f620790">Note—</heading><block><txt break.before="1">See the <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2003-0266" target.version.series="22beab68-19fc-49f7-94e9-1456c1bae50a" check="valid"><name emphasis="yes">Plumbing and Drainage Regulation 2003</name></legref>, <legref jurisd="QLD" type="subordleg" refid="sch.2" target.doc.id="sl-2003-0266" target.version.series="22beab68-19fc-49f7-94e9-1456c1bae50a" check="valid" target.guid="_0569bc55-e0bb-4a91-a6cb-eb8d38cf4cb5">schedule&#160;2</legref> (Qualifications, practical experience and scope of work for restricted licences), item 8.</txt></block></note></block></li><li id="sec.53-ssec.3-para1.b-para2.iii" guid="_d5c196ea-2b72-41f8-a72f-242b5e2b8160" provision.type="other"><no>(iii)</no><block><txt break.before="0">a qualification that the QBCC commissioner decides, or has decided, gives the individual the necessary competence for inspecting and approving on-site sewerage facilities.</txt></block></li></list></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;53</b> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2009-0153" valid.date="as.made" check="invalid">s&#160;7</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2010-0148" target.version.series="642ee0a5-123d-4b09-a72a-5a6b132a4530" valid.date="as.made" check="valid">2010 SL&#160;No.&#160;148</legref> <legref jurisd="QLD" type="subordleg" refid="sec.13" target.doc.id="sl-2010-0148" valid.date="as.made" check="invalid">s&#160;13</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.41" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;41</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0087" target.version.series="4900644b-29d0-40f5-a357-0d45f3cd48f0" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;87</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2013-0087" valid.date="as.made" check="invalid">s&#160;11</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2014-0255" target.version.series="23fbb48d-2573-47da-a20e-802b6d9c2320" valid.date="as.made" check="valid">2014 SL&#160;No.&#160;255</legref> <legref jurisd="QLD" type="subordleg" refid="sec.18" target.doc.id="sl-2014-0255" valid.date="as.made" check="invalid">s&#160;18</legref></txt></historynote></clause></part><part id="pt.7" guid="_44d5d78c-78ac-419d-94df-ea42391324a7" affected.by.uncommenced="0"><no>Part 7</no><heading id="pt.7-he" guid="_8a571202-5d61-498b-a560-93f79d5c3b5a">Miscellaneous provisions</heading><historynote><txt break.before="1"><b>pt hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote><clause id="sec.54" guid="_708f2604-098d-4672-b36b-7dd44413692c" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>54</no><heading id="sec.54-he" guid="_9b04f042-4e6f-4851-b867-f1c56016e166">Maintenance of existing combined sanitary drains</heading><subclause id="sec.54-ssec.1" guid="_69400ea7-f2da-41ab-89c2-4acaea6a61c5" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.54-ssec.1-para1.a" guid="_9a6e0ef4-b380-40be-8d99-0be24fd3ea47" provision.type="other"><no>(a)</no><block><txt break.before="0">2 or more premises in a local government’s sewered area are served by an existing combined sanitary drain; and</txt></block></li><li id="sec.54-ssec.1-para1.b" guid="_64a6a864-8d15-4ee6-a814-b1c990c534a9" provision.type="other"><no>(b)</no><block><txt break.before="0">the drain is obstructed, in disrepair or damaged because of defective materials, breakages or tree root intrusion; and</txt></block></li><li id="sec.54-ssec.1-para1.c" guid="_307d752f-7503-4bd3-aad1-65f165391f9f" provision.type="other"><no>(c)</no><block><txt break.before="0">the owners of the premises can not agree on suitable and fair arrangements for removing the obstruction or repairing or rebuilding the drain.</txt></block></li></list></block></subclause><subclause id="sec.54-ssec.2" guid="_265c38c0-a3c2-4ecf-8339-6aeed8e196b2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">However, this section does not apply to a sanitary drain if the premises that the sanitary drain serves—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.54-ssec.2-para1.a" guid="_28cff2d0-eeeb-4437-8e1a-a1fe4ca3fbd6" provision.type="other"><no>(a)</no><block><txt break.before="0">is included in a community titles scheme under the <legref jurisd="QLD" type="act" target.doc.id="act-1997-028" target.version.series="64bf56de-be45-4387-8ada-9b4f75f32515" check="valid"><name emphasis="yes">Body Corporate and Community Management Act 1997</name></legref>; or</txt></block></li><li id="sec.54-ssec.2-para1.b" guid="_61751e02-36c1-4e44-a855-50886603a29f" provision.type="other"><no>(b)</no><block><txt break.before="0">forms part of a building unit plan or group title plan under the <legref jurisd="QLD" type="act" target.doc.id="act-1980-042" target.version.series="db1baf67-e0e9-4aaa-88d6-6b0407d404c3" check="valid"><name emphasis="yes">Building Units and Group Titles Act 1980</name></legref>.</txt></block></li></list></block></subclause><subclause id="sec.54-ssec.3" guid="_d5c7bcf4-fbe9-4b22-8455-3eb32a90fd92" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">The local government may—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.54-ssec.3-para1.a" guid="_dffa4c84-c909-44ab-9e75-81fa54142f69" provision.type="other"><no>(a)</no><block><txt break.before="0">perform the work; and</txt></block></li><li id="sec.54-ssec.3-para1.b" guid="_b45ba5db-8ec5-42b8-b6f8-8ec38056f8fb" provision.type="other"><no>(b)</no><block><txt break.before="0">fairly apportion the reasonable overall cost between or among the owners; and</txt></block></li><li id="sec.54-ssec.3-para1.c" guid="_a12917a5-5ead-4265-8ffe-1cfc4825039a" provision.type="other"><no>(c)</no><block><txt break.before="0">recover, as a debt from each owner, the owner’s share of the costs.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;54</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote></clause><clause id="sec.54A" guid="_14286a28-10af-495f-a977-0e5a0c801220" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>54A</no><heading id="sec.54A-he" guid="_3925274a-9cc1-4243-90eb-b31ac3390f8f">Notice to water service provider about installation of meters</heading><subclause id="sec.54A-ssec.1" guid="_18dec242-9269-408f-b7c6-bf2d744aa732" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if plumbing work involving the installation of water meters is performed—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.54A-ssec.1-para1.a" guid="_76c8de35-3b4a-4ad0-ba26-e1a7d52ccd67" provision.type="other"><no>(a)</no><block><txt break.before="0">on a building other than a building mentioned in <intref refid="sec.14A" check="valid" target.guid="_b0a9dea6-e71c-4bed-abd9-acb07b165103">section&#160;14A</intref><intref refid="sec.14A-ssec.2" check="valid" target.guid="_5c0faed9-b7c6-43ef-9892-d04ec07abd3c">(2)</intref><intref refid="sec.14A-ssec.2-para1.d" check="valid" target.guid="_96514f1b-7d87-4dc6-b544-70e250b53ad9">(d)</intref>; and</txt></block></li><li id="sec.54A-ssec.1-para1.b" guid="_109be2b9-fd9f-4aa3-a9ed-649fe44410bf" provision.type="other"><no>(b)</no><block><txt break.before="0">after 1 January 2008 in relation to a compliance request made after 31 December 2007.</txt></block></li></list></block></subclause><subclause id="sec.54A-ssec.2" guid="_22ac92d9-2479-4ce5-83b2-1e7eeea87bb2" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The responsible person for the work must, at least 2 business days before the cladding or lining covering the plumbing work is fixed, give the water service provider for the area in which the work is being performed written notice that the water meters are proposed to be installed.</txt></block><penalty id="sec.54A-ssec.2-pen" guid="_e2d4d126-2d35-46e1-bada-ef3d1f54e744"><block><txt break.before="1">Maximum penalty—20 penalty units.</txt></block></penalty></subclause><historynote><txt break.before="1"><b>s&#160;54A</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.13" target.doc.id="sl-2007-0328" valid.date="as.made" check="invalid">s&#160;13</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.28" target.doc.id="sl-2013-0138" valid.date="as.made" check="invalid">s&#160;28</legref></txt></historynote></clause><clause id="sec.55" guid="_51be2a31-c0e8-41e3-bee0-b5bd565fa410" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>55</no><heading id="sec.55-he" guid="_b1fc1175-3c63-48f6-ab47-9000b814781f">Evidentiary aids</heading><subclause id="sec.55-ssec.1" guid="_6d124818-2197-4d02-a582-ad05d0150c58" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to a proceeding under, or in relation to, this regulation.</txt></block></subclause><subclause id="sec.55-ssec.2" guid="_37d3c585-50d6-41f0-b999-095937b2b85e" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">A certificate purporting to be signed by the chief executive stating any of the following matters is evidence of the matter—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.55-ssec.2-para1.a" guid="_d57615bd-a101-4958-8cee-19b6d34f2e7c" provision.type="other"><no>(a)</no><block><txt break.before="0">a stated document is a copy of, or an extract from or part of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.55-ssec.2-para1.a-para2.i" guid="_bb1c9501-b0b2-4914-aa57-eb82cb8f6efe" provision.type="other"><no>(i)</no><block><txt break.before="0">the PCA; or</txt></block></li><li id="sec.55-ssec.2-para1.a-para2.ii" guid="_7440ca7d-a7f8-4676-abdf-0e0c7d285edd" provision.type="other"><no>(ii)</no><block><txt break.before="0">the QPW code;</txt></block></li></list></block></li><li id="sec.55-ssec.2-para1.b" guid="_ac43df9b-e8c3-48f7-a276-cb1e500a0b75" provision.type="other"><no>(b)</no><block><txt break.before="0">an edition of the PCA was the current edition of the PCA at a stated time or during a stated period;</txt></block></li><li id="sec.55-ssec.2-para1.c" guid="_090f7b55-2afe-489f-93c7-11b053019156" provision.type="other"><no>(c)</no><block><txt break.before="0">a particular version of the QPW code was in force at a stated time or during a stated period;</txt></block></li><li id="sec.55-ssec.2-para1.d" guid="_6ea1c21f-1c21-4804-b02a-089a8199fca0" provision.type="other"><no>(d)</no><block><txt break.before="0">a particular part of the QPW code was in force at a stated time or during a stated period.</txt></block></li></list></block></subclause><subclause id="sec.55-ssec.3" guid="_76cc5319-dd87-4194-8d03-adf115990dd3" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In a proceeding under <intref refid="sec.54" check="valid" target.guid="_708f2604-098d-4672-b36b-7dd44413692c">section&#160;54</intref><intref refid="sec.54-ssec.3" check="valid" target.guid="_d5c7bcf4-fbe9-4b22-8455-3eb32a90fd92">(3)</intref> by a local government to recover costs from owners of premises, a certificate by the chief executive officer of the local government stating any of the following matters is evidence of the matter—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.55-ssec.3-para1.a" guid="_673dcba4-8619-4c9d-a4c9-32dea6c01977" provision.type="other"><no>(a)</no><block><txt break.before="0">a matter mentioned in <intref refid="sec.54" check="valid" target.guid="_708f2604-098d-4672-b36b-7dd44413692c">section&#160;54</intref><intref refid="sec.54-ssec.1" check="valid" target.guid="_69400ea7-f2da-41ab-89c2-4acaea6a61c5">(1)</intref>;</txt></block></li><li id="sec.55-ssec.3-para1.b" guid="_bce2678c-c14d-48d9-b386-0f0f4da22408" provision.type="other"><no>(b)</no><block><txt break.before="0">that stated work has been performed under <intref refid="sec.54" check="valid" target.guid="_708f2604-098d-4672-b36b-7dd44413692c">section&#160;54</intref><intref refid="sec.54-ssec.3" check="valid" target.guid="_d5c7bcf4-fbe9-4b22-8455-3eb32a90fd92">(3)</intref><intref refid="sec.54-ssec.3-para1.a" check="valid" target.guid="_dffa4c84-c909-44ab-9e75-81fa54142f69">(a)</intref>;</txt></block></li><li id="sec.55-ssec.3-para1.c" guid="_12d8b9a8-f527-45c3-b4b1-055784d23e1a" provision.type="other"><no>(c)</no><block><txt break.before="0">that a stated apportionment is a fair apportionment of the cost among the owners.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;55</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.8" target.doc.id="sl-2009-0153" valid.date="as.made" check="invalid">s&#160;8</legref></txt></historynote></clause></part><part id="pt.8" guid="_fb2d97fd-1116-4144-9c42-3b1fe3f6742c" affected.by.uncommenced="0"><no>Part 8</no><heading id="pt.8-he" guid="_5bac9e36-5acc-4cf6-b0ca-56cc46cae820">Transitional provisions</heading><historynote><txt break.before="1"><b>pt hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote><historynote><txt break.before="1">sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.42" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;42</legref></txt></historynote><division id="pt.8-div.1" guid="_2d7d11ab-6958-4b1d-af76-edff94be6c3f" affected.by.uncommenced="0"><no>Division 1</no><heading id="pt.8-div.1-he" guid="_e40c5d22-2914-4e5b-84f2-e5eb96c91802">Transitional provisions for <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" check="valid"><name emphasis="no">Plumbing and Drainage Legislation Amendment Regulation (No. 1) 2005</name></legref></heading><historynote><txt break.before="1"><b>div hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.42" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;42</legref></txt></historynote><clause id="sec.56" guid="_4ae74c77-85f7-4342-bac6-f421d3034a56" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>56</no><heading id="sec.56-he" guid="_ebe6faa2-60dd-477e-b273-3650ce4ee1b5">Definitions for <intref refid="pt.8" check="valid" target.guid="_fb2d97fd-1116-4144-9c42-3b1fe3f6742c">pt&#160;8</intref></heading><block><txt break.before="1">In this division—</txt><deflist><definition id="sec.56-def.commencement_" guid="_5eff3beb-c75e-4e73-a070-f4fabb7c532c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.56-def.commencement" guid="_7206a9f9-9db0-4a98-91bb-ffa86ba2a68f" type="definition">commencement</defterm> means the day this section commences.</txt></definition><definition id="sec.56-def.unamendedregulation_" guid="_4af86c7a-4edb-4d2a-a012-bcd32647fea4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.56-def.unamendedregulation" guid="_e5799d3f-4af5-47fd-82ba-ca93e18862e2" type="definition">unamended regulation</defterm> means this regulation as in force immediately before the commencement.</txt></definition></deflist></block><historynote><txt break.before="1"><b>s&#160;56</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2009-0153" valid.date="as.made" check="invalid">s&#160;9</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.43" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;43</legref></txt></historynote></clause><clause id="sec.57" guid="_2d63e183-c3aa-4eb8-8b4c-8d9c0794a5f6" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>57</no><heading id="sec.57-he" guid="_9ccb005c-935e-40ef-8cb0-efe53fbb0834">Existing requests for compliance assessment of plans for regulated work</heading><subclause id="sec.57-ssec.1" guid="_e4d3096f-db4a-42de-92ba-f4c567ad3713" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.57-ssec.1-para1.a" guid="_5a52d6c9-6ef2-4f26-9fdf-5755ba68c058" provision.type="other"><no>(a)</no><block><txt break.before="0">before the commencement, a request for compliance assessment of a plan for regulated work was made under <legref jurisd="QLD" type="subordleg" refid="sec.85" target.doc.id="UNKNOWN" check="invalid">section&#160;85</legref><legref jurisd="QLD" type="subordleg" refid="sec.85-ssec.1" target.doc.id="UNKNOWN" check="invalid">(1)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> as in force immediately before the commencement; and</txt></block></li><li id="sec.57-ssec.1-para1.b" guid="_573e31d2-d443-4735-8c81-dcf93002b412" provision.type="other"><no>(b)</no><block><txt break.before="0">immediately before the commencement, the request had not been decided.</txt></block></li></list></block></subclause><subclause id="sec.57-ssec.2" guid="_c36ffa1b-1ca1-42ac-a46b-7bfebff9c37f" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The unamended regulation applies to—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.57-ssec.2-para1.a" guid="_f7bb2d5e-79f8-4a83-a0ef-583137147603" provision.type="other"><no>(a)</no><block><txt break.before="0">deciding the request; and</txt></block></li><li id="sec.57-ssec.2-para1.b" guid="_4235d220-1747-44ec-ae14-a1cbc6c7d7bf" provision.type="other"><no>(b)</no><block><txt break.before="0">if a compliance permit for the work is given—assessing the plan.</txt></block></li></list></block></subclause><historynote><txt break.before="1"><b>s&#160;57</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote></clause><clause id="sec.58" guid="_37a56304-5728-44e6-b8ba-99d2235f9f81" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>58</no><heading id="sec.58-he" guid="_229d6770-a50c-4691-a35f-5f1015156787">Existing requests for compliance assessment of regulated work</heading><subclause id="sec.58-ssec.1" guid="_dbec59e4-c386-4dff-98cd-5e5504f4091b" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.58-ssec.1-para1.a" guid="_9bced343-2430-438c-993c-05ab46ec227d" provision.type="other"><no>(a)</no><block><txt break.before="0">before the commencement, a request for compliance assessment of regulated work was made under <legref jurisd="QLD" type="subordleg" refid="sec.86" target.doc.id="UNKNOWN" check="invalid">section&#160;86</legref><legref jurisd="QLD" type="subordleg" refid="sec.86-ssec.1" target.doc.id="UNKNOWN" check="invalid">(1)</legref> or <legref jurisd="QLD" type="subordleg" refid="sec.86A" target.doc.id="UNKNOWN" check="invalid">86A</legref><legref jurisd="QLD" type="subordleg" refid="sec.86A-ssec.2" target.doc.id="UNKNOWN" check="invalid">(2)</legref> of the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> as in force immediately before the commencement; and</txt></block></li><li id="sec.58-ssec.1-para1.b" guid="_fd4d58a6-59fa-49fc-9dda-cfed199464ba" provision.type="other"><no>(b)</no><block><txt break.before="0">immediately before the commencement, the work had not been assessed.</txt></block></li></list></block></subclause><subclause id="sec.58-ssec.2" guid="_95aac6a4-788a-417e-b90f-38d08d9c4511" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The unamended regulation applies to assessing the work.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;58</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote></clause><clause id="sec.59" guid="_1548c814-09e6-425c-a131-cb6e418a13b7" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>59</no><heading id="sec.59-he" guid="_232ffbd1-3087-4536-b759-b9012448b180">Plumbing and drainage work</heading><subclause id="sec.59-ssec.1" guid="_954999ee-000e-4a91-98ae-373b1291d5de" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies to the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.59-ssec.1-para1.a" guid="_a0ceaa8f-56d1-443e-baf3-5a8665e3998c" provision.type="other"><no>(a)</no><block><txt break.before="0">regulated work for which a compliance permit has been given before the commencement;</txt></block></li><li id="sec.59-ssec.1-para1.b" guid="_cd2e7ef6-d12c-4e7a-bf1b-7549729bf536" provision.type="other"><no>(b)</no><block><txt break.before="0">minor work or unregulated work, started but not finished before the commencement.</txt></block></li></list></block></subclause><subclause id="sec.59-ssec.2" guid="_87e8725c-3e23-4207-a113-3a32c4d0a9fd" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">The unamended regulation applies to the work.</txt></block></subclause><historynote><txt break.before="1"><b>s&#160;59</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.40" target.doc.id="sl-2005-0323" valid.date="as.made" check="invalid">s&#160;40</legref></txt></historynote></clause></division><division id="pt.8-div.2" guid="_5e825706-d68b-4c78-af35-6b432c0a1527" affected.by.uncommenced="0"><no>Division 2</no><heading id="pt.8-div.2-he" guid="_b919ea0a-bf76-4b55-bef0-ae06d1359159">Transitional provision for <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" check="valid"><name emphasis="no">Plumbing and Drainage and Other Legislation Amendment Regulation (No. 1) 2012</name></legref></heading><historynote><txt break.before="1"><b>div hdg</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.44" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;44</legref></txt></historynote><clause id="sec.60" guid="_926c2202-e5d8-43ec-a21c-e4cb99eded10" affected.by.uncommenced="0" spent.amends="0" provision.type="other"><no>60</no><heading id="sec.60-he" guid="_72950d1c-9931-4507-a170-df551c5a65c8">Plumbing and drainage work</heading><subclause id="sec.60-ssec.1" guid="_bec057cb-2adf-434e-868f-da9ccdc2e36d" affected.by.uncommenced="0" provision.type="other"><no>(1)</no><block><txt break.before="0">This section applies if—</txt><list number.type="manual" unnumbered.indent="0"><li id="sec.60-ssec.1-para1.a" guid="_76e601d1-e141-4171-9c45-03e821bd93f8" provision.type="other"><no>(a)</no><block><txt break.before="0">before the commencement a person has a compliance permit for regulated work and a compliance certificate has not been issued for the work; and</txt></block></li><li id="sec.60-ssec.1-para1.b" guid="_d1c0725d-c67f-4b3e-9f70-55ac3a113352" provision.type="other"><no>(b)</no><block><txt break.before="0">on the commencement the work is notifiable work, minor work or unregulated work.</txt></block></li></list></block></subclause><subclause id="sec.60-ssec.2" guid="_6ec78f38-2dc1-4ced-98ed-68ce78a51bd1" affected.by.uncommenced="0" provision.type="other"><no>(2)</no><block><txt break.before="0">Despite <intref refid="sec.6C" check="valid" target.guid="_fa9c3b2b-71a5-46f0-9a33-96fcc3fc0e50">sections&#160;6C</intref>, <intref refid="sec.7" check="valid" target.guid="_1259ce5a-e775-471a-bfb7-9976e4d96314">7</intref> and <intref refid="sec.8" check="valid" target.guid="_4835b85e-08f2-420e-9875-fe5d7c0f592d">8</intref>, the work is not notifiable work, minor work or unregulated work.</txt></block></subclause><subclause id="sec.60-ssec.3" guid="_d216210a-f534-4301-b690-fafd4adedf67" affected.by.uncommenced="0" provision.type="other"><no>(3)</no><block><txt break.before="0">In this section—</txt><deflist><definition id="sec.60-ssec.3-def.commencement_" guid="_73e963a3-d299-496c-8c15-0a23809f4419" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sec.60-ssec.3-def.commencement" guid="_f7e51465-2120-4730-a04e-6aa682e8caa2" type="definition">commencement</defterm> means the commencement of this section.</txt></definition></deflist></block></subclause><historynote><txt break.before="1"><b>s&#160;60</b> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.44" target.doc.id="sl-2012-0167" valid.date="as.made" check="invalid">s&#160;44</legref></txt></historynote></clause></division></part></body></wrapper><schedules affected.by.uncommenced="0" numbering.style="manual"><schedule id="sch.1" guid="_0f76bb64-c7eb-4f2b-95dd-3bb4a6ba6dd4" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 1</no><heading id="sch.1-he" guid="_e45ee94d-d620-4354-aa30-619c61425b6e">Applied provisions</heading><sourceref id="sch.1-ref" guid="_0cc772de-5405-4bb6-b780-2dc74df96fb0" affected.by.uncommenced="0"><intref refid="sec.5" check="valid" target.guid="_d8ae99cc-f17d-4a50-bf34-efcec8227ab4">section&#160;5</intref></sourceref><block><list number.type="manual" unnumbered.indent="0"><li id="sch.1-para1.1" guid="_f91d088b-eae5-4bb0-afc7-4d1c5a08e7bb" provision.type="other"><no>1</no><block><txt break.before="0">Queensland Development Code, part MP3.5 (Construction of buildings in flood hazard areas)</txt></block></li><li id="sch.1-para1.2" guid="_cb2b2c8f-ed27-4cef-9fc7-54a1ce58dd1d" provision.type="other"><no>2</no><block><txt break.before="0">Queensland Development Code, part MP4.1 (Sustainable buildings)</txt></block></li><li id="sch.1-para1.3" guid="_7fb83206-b687-4e50-b52f-6f913109ac98" provision.type="other"><no>3</no><block><txt break.before="0">Queensland Development Code, part MP4.2 (Water savings targets)</txt></block></li><li id="sch.1-para1.4" guid="_3c0e9364-6629-429d-a2dd-fe365462a2a0" provision.type="other"><no>4</no><block><txt break.before="0">Queensland Development Code, part MP4.3 (Alternative water sources—commercial buildings)</txt></block></li></list></block><historynote><txt break.before="1"><b>sch&#160;1</b> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.41" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s 41</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="invalid">s 10</legref></txt></historynote><historynote><txt break.before="1">sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.30" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="invalid">s 30</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0186" target.version.series="75e94809-181b-4e41-a52a-073fe0177a8a" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;186</legref> <legref jurisd="QLD" type="subordleg" refid="sec.10" target.doc.id="sl-2012-0186" target.version.series="75e94809-181b-4e41-a52a-073fe0177a8a" valid.date="as.made" check="invalid">s 10</legref></txt></historynote></schedule><schedule id="sch.2" guid="_97dba53b-829a-4e6e-9e1e-cba0ecf1b997" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 2</no><heading id="sch.2-he" guid="_69760f73-da66-42bb-9de1-7401550a80cf">Notifiable work</heading><sourceref id="sch.2-ref" guid="_51fb7821-a36b-49fb-bfdf-aaf318299540" affected.by.uncommenced="0"><intref refid="sec.6C" check="valid" target.guid="_fa9c3b2b-71a5-46f0-9a33-96fcc3fc0e50">section&#160;6C</intref></sourceref><part id="sch.2-pt.1" guid="_bc15edd3-bd20-4048-a681-83a89cd23403" affected.by.uncommenced="0" toc="no"><no>Part 1</no><heading id="sch.2-pt.1-he" guid="_0bb0e303-a48b-4157-be9e-ac927e464c48">Notifiable work</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sch.2-pt.1-para1.1" guid="_b50a437c-7c23-43ff-bb11-66810fbb4cca" provision.type="other"><no>1</no><block><txt break.before="0">emergency work</txt></block></li><li id="sch.2-pt.1-para1.2" guid="_fe377ea1-0524-441a-afcb-86b0fa484306" provision.type="other"><no>2</no><block><txt break.before="0">work necessary for extending, altering, replacing or removing existing water supply piping, other than extending or removing a fire service</txt></block></li><li id="sch.2-pt.1-para1.3" guid="_6baa3440-23eb-4535-a431-a70d2939fe00" provision.type="other"><no>3</no><block><txt break.before="0">work necessary for extending or removing a fire service if the work is associated with a building development approval as defined under the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref>, <legref jurisd="QLD" type="act" refid="sch.2" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid" target.guid="_eb2bfe4c-13cb-46ab-9188-07fe0a4b31c8">schedule&#160;2</legref></txt></block></li><li id="sch.2-pt.1-para1.4" guid="_31c53f5f-a83a-487a-80f0-486f47a5f794" provision.type="other"><no>4</no><block><txt break.before="0">work necessary for extending, altering, replacing or removing existing sanitary drainage, other than a combined sanitary drain, for a building classified under BCA as a class 1 or 10 building</txt></block></li><li id="sch.2-pt.1-para1.5" guid="_1aa03f2e-1844-4404-8d60-3bd93014b972" provision.type="other"><no>5</no><block><txt break.before="0">work necessary for extending, altering, replacing or removing existing sanitary plumbing for a building classified under BCA as a class 2 to 9 building</txt></block></li><li id="sch.2-pt.1-para1.6" guid="_e6da3b81-635a-4e31-82dc-5ce54ce6da70" provision.type="other"><no>6</no><block><txt break.before="0">work necessary for installing, replacing or removing a temperature control device</txt></block></li><li id="sch.2-pt.1-para1.7" guid="_1cb1554b-c240-4e57-ba75-3b8a33019fa4" provision.type="other"><no>7</no><block><txt break.before="0">work necessary for installing, replacing or removing a water heater</txt></block></li><li id="sch.2-pt.1-para1.8" guid="_6a95209d-81ea-4252-aed2-9a9dfed547fc" provision.type="other"><no>8</no><block><txt break.before="0">work necessary for installing, replacing or removing a testable backflow prevention device</txt></block></li><li id="sch.2-pt.1-para1.9" guid="_7276305c-4d2b-4edb-b37f-dd73cce3c438" provision.type="other"><no>9</no><block><txt break.before="0">work necessary for installing, replacing or removing a dual check valve with an atmospheric port</txt></block></li><li id="sch.2-pt.1-para1.10" guid="_f82307a8-7316-4e90-a5d7-90e51cdaf40e" provision.type="other"><no>10</no><block><txt break.before="0">work necessary for replacing a greywater treatment plant for a building classified under BCA as a class 1 building</txt></block></li><li id="sch.2-pt.1-para1.11" guid="_6f8aa580-dd5d-4e82-85c0-63831c406767" provision.type="other"><no>11</no><block><txt break.before="0">work necessary for installing a fixture in a building classified under BCA as a class 1 building</txt></block></li><li id="sch.2-pt.1-para1.12" guid="_a0f70d00-90c5-4d74-a205-6ee5d2cfda56" provision.type="other"><no>12</no><block><txt break.before="0">work necessary for relocating a fixture in a building classified under BCA as a class 1 building</txt></block></li><li id="sch.2-pt.1-para1.13" guid="_9f2c08d5-6548-4f0e-b53c-6af95855c335" provision.type="other"><no>13</no><block><txt break.before="0">work, other than work for sanitary drainage, necessary for installing or relocating a fixture in a building, classified under BCA as a class 2 to 9 building, of 1 or 2 storeys</txt></block></li><li id="sch.2-pt.1-para1.14" guid="_b6c9838b-8901-436a-a8d7-3956c11bbb8b" provision.type="other"><no>14</no><block><txt break.before="0">work necessary for installing or relocating a fixture in a building, classified under BCA as a class 10 building</txt></block></li><li id="sch.2-pt.1-para1.15" guid="_fa23b666-30c4-4058-b052-7bd011db20f3" provision.type="other"><no>15</no><block><txt break.before="0">work necessary for sealing a sanitary drain upstream from the connection point for a service provider’s sewerage system</txt></block></li><li id="sch.2-pt.1-para1.16" guid="_30364f6f-6c3a-4c0e-aa15-054d840c145e" provision.type="other"><no>16</no><block><txt break.before="0">work necessary for sealing an existing water service downstream from a water meter for a building classified under BCA as a class 2 to 9 building</txt></block></li></list></block></part><part id="sch.2-pt.2" guid="_e70e4cf2-6e37-486f-87ef-eaa06064534c" affected.by.uncommenced="0" toc="no"><no>Part 2</no><heading id="sch.2-pt.2-he" guid="_73c0af32-96a2-4cb4-b410-55058324fc9b">Plumbing and drainage work that is not notifiable work</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sch.2-pt.2-para1.1" guid="_a775d66b-d94d-469d-a888-207a1b49ae85" provision.type="other"><no>1</no><block><txt break.before="0">plumbing and drainage work for installing a new fixture for a building with dual reticulated water supply provided by a water service provider</txt></block></li><li id="sch.2-pt.2-para1.2" guid="_1bf29cd1-7e86-4d2e-8dd6-6748994d01e7" provision.type="other"><no>2</no><block><txt break.before="0">plumbing and drainage work for, or connected to, trade waste</txt></block></li><li id="sch.2-pt.2-para1.3" guid="_eec2dfc2-9554-4f1e-aa8d-fb99d6aa0f63" provision.type="other"><no>3</no><block><txt break.before="0">plumbing and drainage work necessary for installing a fixture for a building connected to a combined sanitary drain</txt></block></li><li id="sch.2-pt.2-para1.4" guid="_c5392846-6977-4691-a70c-9bc1fb757e02" provision.type="other"><no>4</no><block><txt break.before="0">plumbing and drainage work that complies with—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.2-pt.2-para1.4-para2.a" guid="_ccc4e9f6-9b76-4307-b107-791e7e28ed07" provision.type="other"><no>(a)</no><block><txt break.before="0">the performance requirements of the PCA by formulating an alternative solution that is a means of compliance with the PCA; or</txt></block></li><li id="sch.2-pt.2-para1.4-para2.b" guid="_83eadc1f-b440-46db-ba0f-62e204105566" provision.type="other"><no>(b)</no><block><txt break.before="0">the performance criteria of the QPW code by formulating an alternative solution within the meaning of the QPW code; or</txt></block></li><li id="sch.2-pt.2-para1.4-para2.c" guid="_4f11ca9e-f027-4ae8-81a3-3463e22ec760" provision.type="other"><no>(c)</no><block><txt break.before="0">the performance requirements of the QDC by formulating an alternative solution within the meaning of the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref> that is a means of compliance with the QDC</txt></block></li></list></block></li></list></block></part><historynote><txt break.before="1"><b>sch&#160;2</b> (prev sch&#160;1A) ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.42" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s 42</legref></txt></historynote><historynote><txt break.before="1">sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.14" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="invalid">s 14</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2008-0375" target.version.series="bb1fc8da-25b3-4bf0-8bf3-eb3657151d25" valid.date="as.made" check="valid">2008 SL&#160;No.&#160;375</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2008-0375" target.version.series="bb1fc8da-25b3-4bf0-8bf3-eb3657151d25" valid.date="as.made" check="invalid">s 6</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0017" target.version.series="3e1fbc91-81ae-4943-a6de-290536545319" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;17</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2009-0017" target.version.series="3e1fbc91-81ae-4943-a6de-290536545319" valid.date="as.made" check="invalid">s 9</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.11" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="invalid">s 11</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2010-0021" target.version.series="6ff48d85-f902-4769-8f27-b8c9162325f5" valid.date="as.made" check="valid">2010 SL&#160;No.&#160;21</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2010-0021" target.version.series="6ff48d85-f902-4769-8f27-b8c9162325f5" valid.date="as.made" check="invalid">s 4</legref></txt></historynote><historynote><txt break.before="1">om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2010-0099" target.version.series="8dac3270-db81-45d0-8894-47d88f57695a" valid.date="as.made" check="valid">2010 SL&#160;No.&#160;99</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2010-0099" target.version.series="8dac3270-db81-45d0-8894-47d88f57695a" valid.date="as.made" check="invalid">s 4</legref></txt></historynote><historynote><txt break.before="1">ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 45</legref></txt></historynote><historynote><txt break.before="1">renum <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.48" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 48</legref></txt></historynote></schedule><schedule id="sch.3" guid="_4e06519a-670b-4995-9af6-952d6bdc91ea" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 3</no><heading id="sch.3-he" guid="_0a4664be-5ce9-42dd-8479-2fdae66b1474">Minor work</heading><sourceref id="sch.3-ref" guid="_659a8862-97ca-4cd2-9d03-a95c4cb78888" affected.by.uncommenced="0"><intref refid="sec.7" check="valid" target.guid="_1259ce5a-e775-471a-bfb7-9976e4d96314">section&#160;7</intref></sourceref><block><list number.type="manual" unnumbered.indent="0"><li id="sch.3-para1.1" guid="_899a08d7-b749-4f7e-b0f9-cd1906ac0904" provision.type="other"><no>1</no><block><txt break.before="0">work necessary for replacing, maintaining, repairing or removing a fitting or fixture</txt></block></li><li id="sch.3-para1.2" guid="_7f96f411-7210-4e1b-8b16-90d37810c3db" provision.type="other"><no>2</no><block><txt break.before="0">work necessary for repairing a broken or damaged pipe</txt></block></li><li id="sch.3-para1.3" guid="_6bcee7a2-516c-470a-bfd8-9dc6cbfdbb87" provision.type="other"><no>3</no><block><txt break.before="0">work necessary for installing, replacing, maintaining, repairing or removing an apparatus, but not if the work involves the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.3-para1.3-para2.a" guid="_b781a9f2-2867-44fb-a73d-0fea02d8468e" provision.type="other"><no>(a)</no><block><txt break.before="0">work necessary for installing, replacing or removing any of the following apparatus—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.3-para1.3-para2.a-para3.i" guid="_6a610576-b254-429a-bed8-6ce31b632235" provision.type="other"><no>(i)</no><block><txt break.before="0">a temperature control device;</txt></block></li><li id="sch.3-para1.3-para2.a-para3.ii" guid="_dd8274cd-6c6b-420a-8829-00914ae26563" provision.type="other"><no>(ii)</no><block><txt break.before="0">a water heater;</txt></block></li><li id="sch.3-para1.3-para2.a-para3.iii" guid="_17b78666-a93f-47ec-ab58-abd39808da93" provision.type="other"><no>(iii)</no><block><txt break.before="0">a testable backflow prevention device;</txt></block></li><li id="sch.3-para1.3-para2.a-para3.iv" guid="_f499cb13-da48-4801-ab91-226c356ba5d0" provision.type="other"><no>(iv)</no><block><txt break.before="0">a dual check valve with an atmospheric port;</txt></block></li></list></block></li><li id="sch.3-para1.3-para2.b" guid="_cd6d5ab1-7975-4ae6-b112-387f2a158b55" provision.type="other"><no>(b)</no><block><txt break.before="0">replacing a domestic water filter cartridge</txt><note id="sch.3-para1.3-para2.b-note" guid="_132b7162-d289-4d30-a322-f34e38fdac55" type="example"><heading id="sch.3-para1.3-para2.b-note-he" guid="_fb0e58ab-0055-4279-8f8a-aa5efa4b3aac">Note—</heading><block><txt break.before="1">Replacing a domestic water filter cartridge is unregulated work. See <intref refid="sch.4" check="valid" target.guid="_05790a71-fd19-484c-a61e-a2e3a97156e9">schedule&#160;4</intref>.</txt></block></note></block></li></list></block></li><li id="sch.3-para1.4" guid="_c7c9a8e2-76b7-4347-9004-7e7488601755" provision.type="other"><no>4</no><block><txt break.before="0">work necessary for sealing an existing water service downstream from the water meter for a building classified under BCA as a class 1 or 10 building</txt></block></li><li id="sch.3-para1.5" guid="_072e5ea2-9d16-418b-a4cb-a67dacbf3466" provision.type="other"><no>5</no><block><txt break.before="0">work necessary for maintaining, repairing or replacing fire hydrants or fire hose reels</txt></block></li><li id="sch.3-para1.6" guid="_c93e4d1b-d2a2-4740-adf3-34641ed53f19" provision.type="other"><no>6</no><block><txt break.before="0">work necessary for unblocking a pipe that is sanitary plumbing or sanitary drainage</txt></block></li><li id="sch.3-para1.7" guid="_d9748c86-091f-4697-998c-fd273a35f22e" provision.type="other"><no>7</no><block><txt break.before="0">work necessary for repairing or maintaining an on-site sewerage facility</txt></block></li><li id="sch.3-para1.8" guid="_d35f7547-4adf-4ed0-9559-26b297fbacfb" provision.type="other"><no>8</no><block><txt break.before="0">work necessary for maintaining or repairing a greywater use facility</txt></block></li><li id="sch.3-para1.9" guid="_0a0f43c8-b8cf-40e3-9d1f-08ca1cf75ace" provision.type="other"><no>9</no><block><txt break.before="0">work necessary for installing or replacing an automatic switching device, within the meaning of the QPW code, for a rainwater tank installation</txt></block></li></list></block><historynote><txt break.before="1"><b>sch&#160;3</b> (prev sch&#160;2) amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.43" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s 43</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0192" target.version.series="33d4186d-8f26-40f2-a144-0ef3a75d0878" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;192</legref> <legref jurisd="QLD" type="subordleg" refid="sec.9" target.doc.id="sl-2009-0192" target.version.series="33d4186d-8f26-40f2-a144-0ef3a75d0878" valid.date="as.made" check="invalid">s 9</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2010-0099" target.version.series="8dac3270-db81-45d0-8894-47d88f57695a" valid.date="as.made" check="valid">2010 SL&#160;No.&#160;99</legref> <legref jurisd="QLD" type="subordleg" refid="sec.5" target.doc.id="sl-2010-0099" target.version.series="8dac3270-db81-45d0-8894-47d88f57695a" valid.date="as.made" check="invalid">s 5</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0134" target.version.series="bff83d04-f292-4dfc-8b99-2d22ba04aef9" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;134</legref> <legref jurisd="QLD" type="subordleg" refid="sec.7" target.doc.id="sl-2011-0134" target.version.series="bff83d04-f292-4dfc-8b99-2d22ba04aef9" valid.date="as.made" check="invalid">s 7</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.46" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 46</legref></txt></historynote><historynote><txt break.before="1">renum <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.48" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 48</legref></txt></historynote></schedule><schedule id="sch.4" guid="_05790a71-fd19-484c-a61e-a2e3a97156e9" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 4</no><heading id="sch.4-he" guid="_c4807af5-ee66-4211-9cca-81974b26b8c1">Unregulated work</heading><sourceref id="sch.4-ref" guid="_3af7bc47-29c1-4d79-a9a2-1cd3b1b0b184" affected.by.uncommenced="0"><intref refid="sec.8" check="valid" target.guid="_4835b85e-08f2-420e-9875-fe5d7c0f592d">section&#160;8</intref></sourceref><block><txt break.before="1"><b>For sanitary plumbing and sanitary drainage</b></txt></block><block><list number.type="manual" unnumbered.indent="0"><li id="sch.4-para1" guid="_c7d1dc6a-a478-490e-bccc-41870cd864c4" provision.type="other"><no>•</no><block><txt break.before="0">cleaning or maintaining ground level grates to traps on sanitary drains</txt></block></li><li id="sch.4-para1-oc.2" guid="_54b1312c-c97c-4ff2-bb22-69fb34bedd74" provision.type="other"><no>•</no><block><txt break.before="0">replacing caps to ground level inspection openings on sanitary drains</txt></block></li><li id="sch.4-para1-oc.3" guid="_49922d50-9dfe-427e-9cf2-07e36688be81" provision.type="other"><no>•</no><block><txt break.before="0">maintaining an above or below ground irrigation system for the disposal of effluent from an on-site sewerage facility or greywater use facility</txt></block></li></list></block><block><txt break.before="1"><b>For water plumbing</b></txt></block><block><list number.type="manual" unnumbered.indent="0"><li id="sch.4-para1-oc.4" guid="_b20b3dd1-88bd-4b19-ba56-e2e1d2bdf466" provision.type="other"><no>•</no><block><txt break.before="0">installing or maintaining an irrigation or lawn watering system downstream from an isolating valve, tap or backflow prevention device on the supply pipe for the irrigation or lawn watering system</txt></block></li><li id="sch.4-para1-oc.5" guid="_946480cf-5bfc-4ec2-a131-94776c033bf0" provision.type="other"><no>•</no><block><txt break.before="0">replacing a jumper valve or washer in a tap</txt></block></li><li id="sch.4-para1-oc.6" guid="_f4843112-9cdd-408d-b9f5-772e8c1536eb" provision.type="other"><no>•</no><block><txt break.before="0">changing a shower head</txt></block></li><li id="sch.4-para1-oc.7" guid="_2c21456c-c6a8-4fbf-9901-9c4d9c213a8a" provision.type="other"><no>•</no><block><txt break.before="0">replacing, in a water closet (WC) cistern, a drop valve washer, float valve washer or suction cup rubber</txt></block></li><li id="sch.4-para1-oc.8" guid="_699bfa6b-f1d5-43b2-9c89-65f5b860dcba" provision.type="other"><no>•</no><block><txt break.before="0">replacing a domestic water filter cartridge</txt></block></li></list></block><historynote><txt break.before="1"><b>sch&#160;4</b> (prev sch&#160;3) amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.47" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 47</legref></txt></historynote><historynote><txt break.before="1">renum <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.48" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 48</legref></txt></historynote></schedule><schedule id="sch.5" guid="_de7922dd-3d08-4c61-952c-938f2ea5ebf9" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="other"><no>Schedule 5</no><heading id="sch.5-he" guid="_a782de39-851a-4e8d-ba1f-4422bacb4e2f">Work for which approved person may give compliance reports</heading><sourceref id="sch.5-ref" guid="_a0066b51-1ac2-42e9-a83a-13b9e7b062c0" affected.by.uncommenced="0"><intref refid="sec.22" check="valid" target.guid="_bf7985a2-f008-426f-8e65-3c0b2e131b7b">section&#160;22</intref></sourceref><part id="sch.5-pt.1" guid="_0c101d05-83a2-47ff-866c-62c808a7c59b" affected.by.uncommenced="0" toc="no"><no>Part 1</no><heading id="sch.5-pt.1-he" guid="_5f675e2c-9439-4f35-a68b-3f03f9e352d6">Complying with deemed-to-satisfy provisions under PCA</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sch.5-pt.1-para1.1" guid="_1dcb78f0-9198-49ba-8ffe-f71748bd69b2" provision.type="other"><no>1</no><block><txt break.before="0">testing or commissioning of a water service in accordance with AS/NZS 3500.1:2003 (Plumbing and drainage—Water services), <intref refid="sec.16" check="valid" target.guid="_69f0c0f3-e4db-41e9-8b30-56fd2774898b">section&#160;16</intref></txt></block></li><li id="sch.5-pt.1-para1.2" guid="_f1222294-9a58-4f95-9c39-a828c11b1052" provision.type="other"><no>2</no><block><txt break.before="0">testing or commissioning of a sanitary plumbing or drainage installation in accordance with AS/NZS 3500.2:2003 (Plumbing and drainage—Sanitary plumbing and drainage), <intref refid="sec.13" check="valid" target.guid="_bc96d2ff-75bf-4d92-bcd9-96aec710c6ea">section&#160;13</intref></txt></block></li><li id="sch.5-pt.1-para1.3" guid="_832fa9ad-aa8d-4b59-99f3-c897d3523c23" provision.type="other"><no>3</no><block><txt break.before="0">testing or commissioning of a heated water service in accordance with AS/NZS 3500.4:2003 (Plumbing and drainage—Heated water services), <intref refid="sec.11" check="valid" target.guid="_1f4d4e9b-058c-4d29-adc2-342472e09bc0">section&#160;11</intref></txt></block></li></list></block></part><part id="sch.5-pt.2" guid="_742feb21-1417-4430-9855-c3a776e06fb5" affected.by.uncommenced="0" toc="no"><no>Part 2</no><heading id="sch.5-pt.2-he" guid="_773ae909-fd70-49ab-845a-ee3dbd736a70">Complying with alternative solutions under PCA</heading><block><list number.type="manual" unnumbered.indent="0"><li id="sch.5-pt.2-para1.4" guid="_b8deb6f7-4980-41df-95b2-0b496fde3b4d" provision.type="other"><no>4</no><block><txt break.before="0">testing or commissioning of a cold water service to ensure the installation of the cold water service complies with the performance requirements of PCA, part B1 (Cold water services)</txt></block></li><li id="sch.5-pt.2-para1.5" guid="_97e317de-a5f6-41e3-b161-951df0fca98e" provision.type="other"><no>5</no><block><txt break.before="0">testing or commissioning of a heated water service to ensure—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.5-pt.2-para1.5-para2.a" guid="_437d3087-ce40-43ee-af06-4ce05d003f85" provision.type="other"><no>(a)</no><block><txt break.before="0">the installation of the heated water service complies with the performance requirements of PCA, part B2 (Heated water services); and</txt></block></li><li id="sch.5-pt.2-para1.5-para2.b" guid="_a14b7b8c-bf7e-4e54-a00e-dfde562a3114" provision.type="other"><no>(b)</no><block><txt break.before="0">the hot water delivery temperatures comply with this regulation</txt></block></li></list></block></li><li id="sch.5-pt.2-para1.6" guid="_9be9e88c-dc5e-41e3-b036-a57f14d2b4e2" provision.type="other"><no>6</no><block><txt break.before="0">testing or commissioning of a sanitary plumbing or drainage installation to ensure the sanitary plumbing or drainage complies with the performance requirements of PCA, part C1 (Sanitary plumbing systems) or C2 (Sanitary drainage systems)</txt></block></li></list></block></part><historynote><txt break.before="1"><b>sch&#160;5</b> prev sch&#160;5 amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2010-0148" target.version.series="642ee0a5-123d-4b09-a72a-5a6b132a4530" valid.date="as.made" check="valid">2010 SL&#160;No.&#160;148</legref> <legref jurisd="QLD" type="subordleg" refid="sec.14" target.doc.id="sl-2010-0148" target.version.series="642ee0a5-123d-4b09-a72a-5a6b132a4530" valid.date="as.made" check="invalid">s 14</legref></txt></historynote><historynote><txt break.before="1">om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;265</legref> <legref jurisd="QLD" type="subordleg" refid="sec.31" target.doc.id="sl-2011-0265" target.version.series="90d3c1ef-4b34-4b70-87c6-dbb2b68a3cf0" valid.date="as.made" check="invalid">s 31</legref></txt></historynote><historynote><txt break.before="1">pres sch&#160;5 (prev sch&#160;4) sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.44" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s 44</legref></txt></historynote><historynote><txt break.before="1">renum <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.48" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s 48</legref></txt></historynote></schedule><schedule id="sch.6" guid="_70709acf-780e-4d4c-ac77-9837571ef12e" type="schedule" affected.by.uncommenced="0" spent.amends="0" numbering.style="manual" provision.type="definitions"><no>Schedule 6</no><heading id="sch.6-he" guid="_5c3dd975-d167-4377-87e2-a9c9ac4d977f">Dictionary</heading><sourceref id="sch.6-ref" guid="_156dc9a2-ff42-41cd-a44e-1a10f01650b2" affected.by.uncommenced="0"><intref refid="sec.4" check="valid" target.guid="_5ece959f-6bed-4f64-9f32-41eec0cb0303">section&#160;4</intref><intref refid="sec.4-ssec.1" check="valid" target.guid="_3e83f227-79c6-4ffe-b638-74fa26827655">(1)</intref></sourceref><block><deflist><definition id="sch.6-def.48hours_" guid="_fea7593a-0698-4b62-9177-9c41302d60f3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.48hours" guid="_07c23d24-af7e-49d5-8024-6ec66e3abcf0" type="definition">48 hours</defterm>, for a provision about assessing compliance assessable work or inspecting notifiable work—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.48hours-para1.a" guid="_e03f21de-9b1a-4d5e-80ec-1cc911689cf5" provision.type="other"><no>(a)</no><block><txt break.before="0">means a 48 hour period; but</txt></block></li><li id="sch.6-def.48hours-para1.b" guid="_87f96ee9-aca4-4b5a-90db-050c2475dfbe" provision.type="other"><no>(b)</no><block><txt break.before="0">if a day that is not a business day occurs within the 48 hour period—does not include the day in the calculation of the 48 hour period.</txt><note id="sch.6-def.48hours-para1.b-note" guid="_862f4511-928c-463d-8d5a-d75784453f1b" type="example"><heading id="sch.6-def.48hours-para1.b-note-he" guid="_3a82a621-e5ef-4a63-96d8-e86cf64f9a3e">Example—</heading><block><txt break.before="1">A local government receives a request for compliance assessment of work on Friday at 10a.m. The following Tuesday at 10a.m. is 48 hours after receiving the request.</txt></block></note></block></li></list><historynote><txt break.before="1">def <defterm guid="_eafeff7f-9bb9-4bb7-b3ae-e84f889e395b" type="mention">48 hours</defterm> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">s&#160;29</legref><legref jurisd="QLD" type="subordleg" refid="sec.29-ssec.1" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">(1)</legref>–<legref jurisd="QLD" type="subordleg" refid="sec.29-ssec.2" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.AHD_" guid="_572a4e7f-fa21-4a5a-80a3-27b31a149516" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.AHD" guid="_5de2c1ca-e29a-42cf-8514-90ecb1ffb67c" type="definition">AHD</defterm> means the Australian height datum adopted by the National Mapping Council of Australia for referencing a level or height back to a standard base level.</txt></definition><definition id="sch.6-def.aircoolingequipment_" guid="_6b57c23d-2f67-4e92-8b42-c2a9d9a07c90" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.aircoolingequipment" guid="_0941f992-5f3a-4808-83e1-be658bbe01c4" type="definition">air cooling equipment</defterm> see glossary.</txt></definition><definition id="sch.6-def.airgap_" guid="_fc2d0d0a-4901-4f70-9a47-8bdf095bcdc5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.airgap" guid="_c3e70bec-7dda-44fa-a221-df3bc505e1ee" type="definition">air gap</defterm> see glossary.</txt></definition><definition id="sch.6-def.apparatus_" guid="_29b2fb7f-5e79-4be3-8eca-669c276b8116" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.apparatus" guid="_f8fa133c-4d13-4504-b085-4363b0a3e28f" type="definition">apparatus</defterm>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.apparatus-para1.a" guid="_484db672-eab4-4e2a-a6ab-313e47dc52a9" provision.type="other"><no>(a)</no><block><txt break.before="0">for sanitary plumbing, sanitary drainage and on-site sewerage facilities—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.apparatus-para1.a-para2.i" guid="_53ba7ecf-11bd-4cdf-824d-9958a463719e" provision.type="other"><no>(i)</no><block><txt break.before="0">includes an arrestor, cistern, pump, siphon or valve; but</txt></block></li><li id="sch.6-def.apparatus-para1.a-para2.ii" guid="_77afb2cb-4442-45b3-a7bb-affa48dd2ab9" provision.type="other"><no>(ii)</no><block><txt break.before="0">does not include an appliance, fitting, fixture or straight pipe; or</txt></block></li></list></block></li><li id="sch.6-def.apparatus-para1.b" guid="_5fdbe19f-755f-40b2-88de-aa3da348e97d" provision.type="other"><no>(b)</no><block><txt break.before="0">for water plumbing—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.apparatus-para1.b-para2.i" guid="_24c4e515-f5ed-4be0-8a90-f727dfeb957e" provision.type="other"><no>(i)</no><block><txt break.before="0">includes a backflow prevention device, cistern, pump, domestic water filter, water meter, siphon, tap, valve, water heater or water softener; but</txt></block></li><li id="sch.6-def.apparatus-para1.b-para2.ii" guid="_f91a811f-283d-4a1f-afe5-a4f2bd704d7e" provision.type="other"><no>(ii)</no><block><txt break.before="0">does not include an appliance, fitting or straight pipe.</txt></block></li></list></block></li></list><historynote><txt break.before="1">def <defterm guid="_7bdfe881-cf1d-4be4-bde3-504d6da27f2a" type="mention">apparatus</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="invalid">s&#160;15</legref><legref jurisd="QLD" type="subordleg" refid="sec.15-ssec.2" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.appliance_" guid="_fcf4e2c1-cf08-4569-9b07-8eab66fb77a3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.appliance" guid="_59a25664-5468-4797-b4dc-46eefab1be92" type="definition">appliance</defterm> see glossary.</txt></definition><definition id="sch.6-def.appliedprovisions_" guid="_5b4a9dc7-eb8a-48d3-b5c0-95eabfb4a4e2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.appliedprovisions" guid="_cc841ab5-5315-4d09-af79-d6a7c0aefdc5" type="definition">applied provisions</defterm> see <intref refid="sec.5" check="valid" target.guid="_d8ae99cc-f17d-4a50-bf34-efcec8227ab4">section&#160;5</intref><intref refid="sec.5-ssec.1" check="valid" target.guid="_5777f2ed-dcaa-4587-9e8a-7e363333d4d0">(1)</intref>.</txt></definition><definition id="sch.6-def.arrestor_" guid="_76d87cc7-c550-4d7a-8ac7-fa497c5fc7d8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.arrestor" guid="_cddd4d53-d45f-4549-8af0-569ca7042c9c" type="definition">arrestor</defterm> see glossary.</txt></definition><definition id="sch.6-def.ASNZS_" guid="_5f6c3141-f51f-48f3-a43b-68490e7a0ab4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.ASNZS" guid="_5bd6e9f1-9bef-4809-8145-3289ac876d5f" type="definition">AS/NZS</defterm> means a joint Standards Australia and Standards New Zealand standard.</txt><historynote><txt break.before="1">def <defterm guid="_2579f20e-f5f5-4f26-b519-ae666f48b5fc" type="mention">AS/NZS</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.backfill_" guid="_af57a34d-33d5-4744-913f-98b50362e6fa" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.backfill" guid="_901d7445-b50d-4b16-b90d-ef763eee36a3" type="definition">backfill</defterm> means fill.</txt></definition><definition id="sch.6-def.basement_" guid="_7b88c130-40c2-4ba8-a7bb-682724e7387a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.basement" guid="_f5e96e6a-2221-4f74-a0bd-7863de76bad6" type="definition">basement</defterm> see glossary.</txt></definition><definition id="sch.6-def.BCA_" guid="_9d1e4e12-9db3-4283-8d8d-05b2811848cd" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.BCA" guid="_5aa92a92-1b6d-493b-b349-7dda79d655e5" type="definition">BCA</defterm> means the Building Code of Australia.</txt></definition><definition id="sch.6-def.bedpanwasher_" guid="_a0e2e572-dc8c-4db8-bc44-3f9f52ed6923" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.bedpanwasher" guid="_ab4a3ea7-dcd8-49d1-bcdc-580f576ef4b8" type="definition">bedpan washer</defterm> see glossary.</txt></definition><definition id="sch.6_" guid="_afb65d32-00dc-454a-9e7e-879cf8bee4df" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.bend" guid="_df71fdfa-5115-45cc-b99a-1432c545feee" type="mention">bend</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_ffe1ca02-ed19-4960-ad6a-5e3eb93058ba" type="mention">bend</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.1" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.bodyofwater_" guid="_fa2010c0-04ce-4f92-9c33-4a11e3adfb98" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.bodyofwater" guid="_79a2b601-8829-44b7-8fc5-e5719e803c43" type="definition">body of water</defterm> means groundwater or a creek, lake, lagoon, marsh, river, stream, swamp or permanent or intermittent watercourse.</txt><historynote><txt break.before="1">def <defterm guid="_b8d744ac-def0-4d34-844c-2dfd1e99e7a6" type="mention">body of water</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.building_" guid="_0122a3be-a21e-4077-9827-9ac7524dbba2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.building" guid="_52026cdd-9aae-40ce-9aae-1a1d597bbbc5" type="definition">building</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref>, <legref jurisd="QLD" type="act" refid="sch.2" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid" target.guid="_eb2bfe4c-13cb-46ab-9188-07fe0a4b31c8">schedule&#160;2</legref>.</txt><historynote><txt break.before="1">def <defterm guid="_bc40bea3-8bef-46c9-beb1-fb7331efd754" type="mention">building</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6_-oc.2" guid="_23af3c8a-7b92-4f70-99dc-5c9407cddcb6" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.BuildingCodeofAustralia" guid="_2510a28b-4350-4b1e-bf02-ca02b7f1f97f" type="mention">Building Code of Australia</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_b62b10a3-33e5-486b-bb26-3608a0bb9885" type="mention">Building Code of Australia</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.certifieditem_" guid="_e95f09b8-b77e-4458-8533-c00507e8d50e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.certifieditem" guid="_5934ccd2-b77c-4430-a8d0-778efe909b84" type="definition">certified item</defterm> means a plumbing or drainage item that has plumbing code authorisation and certification before installation or use.</txt><historynote><txt break.before="1">def <defterm guid="_09c6f632-1113-4aea-9c28-a0f42a45f043" type="mention">certified item</defterm> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref>–<legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.chamber_" guid="_34077d95-b897-4ad2-b052-f375c8b6757e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.chamber" guid="_c96b226f-4d88-4f0a-a0ba-2c1b34bc8a09" type="definition">chamber</defterm> see glossary.</txt></definition><definition id="sch.6-def.channel_" guid="_6b426b47-9d38-490d-b568-fb6a3b2d2be7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.channel" guid="_adf7f406-5457-437f-bc22-e9f28ec05dfa" type="definition">channel</defterm> see glossary.</txt></definition><definition id="sch.6-def.cistern_" guid="_7834b1ae-0a08-4561-99a8-f6dff9e52e7f" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.cistern" guid="_8f26036c-a856-4e2a-9e08-65c8bb326eac" type="definition">cistern</defterm> see glossary.</txt></definition><definition id="sch.6-def.combinedsanitarydrain_" guid="_7cf62228-f38d-41fe-aa80-7df9c0285fdc" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.combinedsanitarydrain" guid="_4bd7f05c-cef2-4e97-a6a4-51ef0f394208" type="definition">combined sanitary drain</defterm> means a sanitary drain for discharges from 2 or more adjacent premises.</txt><historynote><txt break.before="1">def <defterm guid="_8864bf5e-53cb-4be5-8f0a-90c0c1c9e468" type="mention">combined sanitary drain</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.commission_" guid="_5c3da501-ebeb-4585-a5ee-3fd9b052505a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.commission" guid="_9e9f2f72-dcf0-4d60-a8fd-1aa5ed6b8a58" type="definition">commission</defterm>, plumbing or drainage—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.commission-para1.a" guid="_1b955675-b7d1-4e97-9f1a-3d31ac6fcb65" provision.type="other"><no>(a)</no><block><txt break.before="0">means check the operation of a potable cold water service or hot water service associated with the plumbing or drainage to confirm the correct functioning of apparatus installed in the water service; and</txt></block></li><li id="sch.6-def.commission-para1.b" guid="_07b67d7d-8cea-4108-af33-3d1c5ee2f635" provision.type="other"><no>(b)</no><block><txt break.before="0">includes check the delivery temperature of hot water at a specified outlet does not exceed the maximum temperature allowed for the hot water.</txt></block></li></list></definition><definition id="sch.6-def.communitytitlesscheme_" guid="_220a7468-1264-4db7-be72-96eb894f31bd" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.communitytitlesscheme" guid="_435080f6-d1ab-409c-832f-ccaac195c00d" type="definition">community titles scheme</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1997-028" target.version.series="64bf56de-be45-4387-8ada-9b4f75f32515" check="valid"><name emphasis="yes">Body Corporate and Community Management Act 1997</name></legref>, <legref jurisd="QLD" type="act" refid="sec.10" target.doc.id="act-1997-028" target.version.series="64bf56de-be45-4387-8ada-9b4f75f32515" check="valid" target.guid="_e3bbf896-eeb2-4a19-aeb1-705e88ef5ef0">section&#160;10</legref>.</txt></definition><definition id="sch.6-def.competentperson_" guid="_e47a4455-b68b-4bba-9b83-de93364641db" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.competentperson" guid="_c575ace2-ef4b-47a1-bbc3-99902bdbc21b" type="definition">competent person</defterm>, for plumbing or drainage work, means a person who—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.competentperson-para1.a" guid="_d02a21b2-ba8c-4626-8c06-b47e099a8bc2" provision.type="other"><no>(a)</no><block><txt break.before="0">in the opinion of the local government, is competent to practise in the aspect of design of plumbing or drainage, including, for example, giving and certifying plans for plumbing or drainage work; and</txt></block></li><li id="sch.6-def.competentperson-para1.b" guid="_ff9daef6-450c-4add-be50-8183bb68d453" provision.type="other"><no>(b)</no><block><txt break.before="0">if required under the <legref jurisd="QLD" type="subordleg" target.doc.id="UNKNOWN" check="invalid">Act</legref> or another Act to be registered or licensed to practise in the aspect, is registered or licensed.</txt></block></li></list><historynote><txt break.before="1">def <defterm guid="_21f7f5c2-f3ba-4433-88c4-7d94805d5241" type="mention">competent person</defterm> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref>–<legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">s&#160;29</legref><legref jurisd="QLD" type="subordleg" refid="sec.29-ssec.3" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">(3)</legref>–<legref jurisd="QLD" type="subordleg" refid="sec.29-ssec.5" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">(5)</legref></txt></historynote></definition><definition id="sch.6-def.compliancereport_" guid="_e405b546-7399-4b20-b8ce-0de837f75df7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.compliancereport" guid="_74e7f246-c1b1-4efa-84b2-62197cc8bf0f" type="definition">compliance report</defterm> see <intref refid="sec.22" check="valid" target.guid="_bf7985a2-f008-426f-8e65-3c0b2e131b7b">section&#160;22</intref><intref refid="sec.22-ssec.4" check="valid" target.guid="_5feca172-30be-4780-9ac9-ad4a5de4e96f">(4)</intref>.</txt><historynote><txt break.before="1">def <defterm guid="_536c5aad-2067-478f-9169-544b5a9421df" type="mention">compliance report</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;153</legref> <legref jurisd="QLD" type="subordleg" refid="sec.12" target.doc.id="sl-2009-0153" target.version.series="f4e13c52-0c72-4685-81b7-139ad3746fd8" valid.date="as.made" check="invalid">s&#160;12</legref></txt></historynote></definition><definition id="sch.6_-oc.3" guid="_ce1a9ade-bbda-4725-8a8e-de7a3a3a3668" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.component" guid="_f4272986-57f3-41e1-8277-c659569b24ea" type="mention">component</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_7183c2e2-1f0c-4e14-86de-c196fe155463" type="mention">component</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.1" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.condensate_" guid="_952cca20-f5ae-4089-9538-8f84d7afbdc8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.condensate" guid="_fa12cab9-9952-44fe-b787-a38d2e9e763d" type="definition">condensate</defterm> see glossary.</txt></definition><definition id="sch.6-def.connectionpoint_" guid="_9a367504-0a39-4b68-9115-df0174b9c87d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.connectionpoint" guid="_bd0f40b4-28c0-42b4-b99d-0abd8a4b472f" type="definition">connection point</defterm>—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.connectionpoint-para1.1" guid="_fbd446ae-0178-4827-908e-e443e6909a1c" provision.type="other"><no>1</no><block><txt break.before="0">A <defterm guid="_5ed1d835-4d2e-45c6-a25f-fe8a544efa9d" type="mention">connection point</defterm>, for a service provider’s water supply system, means the point for the connection to the service provider’s water supply system of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.connectionpoint-para1.1-para2.a" guid="_7bd464e8-da87-431a-9280-9331e2344a0b" provision.type="other"><no>(a)</no><block><txt break.before="0">a supply pipe or premises main for premises; or</txt></block></li><li id="sch.6-def.connectionpoint-para1.1-para2.b" guid="_a28ac215-5597-45f6-855c-cbfa36b6f0f3" provision.type="other"><no>(b)</no><block><txt break.before="0">a premises group main for a premises group.</txt></block></li></list></block></li><li id="sch.6-def.connectionpoint-para1.2" guid="_7d7bc892-d48f-4e52-9754-65fff159a3f7" provision.type="other"><no>2</no><block><txt break.before="0">A <defterm guid="_a2faf13e-bf4a-42f4-827c-c2021a5e7d57" type="mention">connection point</defterm>, for a service provider’s sewerage system, means the point for the connection to the service provider’s sewerage system of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.connectionpoint-para1.2-para2.a" guid="_a61cf1f5-77b4-4b35-a6d7-0dea208ceff8" provision.type="other"><no>(a)</no><block><txt break.before="0">a sanitary drain or premises sewer for premises; or</txt></block></li><li id="sch.6-def.connectionpoint-para1.2-para2.b" guid="_84b2b7a5-f6de-4eb1-b992-5de937f2f582" provision.type="other"><no>(b)</no><block><txt break.before="0">a premises group sewer for a premises group.</txt></block></li></list></block></li></list></definition><definition id="sch.6-def.cover_" guid="_3da537a4-3874-4699-8983-d871079b89c7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.cover" guid="_5e6a16ef-15f7-48d9-b83a-1b76040345f4" type="definition">cover</defterm> see glossary.</txt></definition><definition id="sch.6-def.disconnectorgully_" guid="_60daafda-84c9-481c-a208-880eeb46e76b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.disconnectorgully" guid="_54ac6650-c30f-4c72-88c0-86e313eec39d" type="definition">disconnector gully</defterm> see glossary.</txt></definition><definition id="sch.6-def.doublecheckvalve_" guid="_c7613a00-f1df-4071-9a22-0cd9958d3e3c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.doublecheckvalve" guid="_3485793d-691f-456d-81b8-28c195da744d" type="definition">double check valve</defterm> see glossary.</txt></definition><definition id="sch.6-def.dualcheckvalvewithanatmosphericport_" guid="_16164aaf-6d33-44fa-ba07-2590ab3c6d47" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.dualcheckvalvewithanatmosphericport" guid="_6adefbbf-1279-4023-acc0-a603bf99df56" type="definition">dual check valve with an atmospheric port</defterm> see glossary.</txt><note id="sch.6-def.dualcheckvalvewithanatmosphericport-note" guid="_a4c18d77-7b36-4174-a1ad-d54fe57e8185" type="example"><heading id="sch.6-def.dualcheckvalvewithanatmosphericport-note-he" guid="_9694f20b-3178-4590-a618-71bfca290918">Note—</heading><block><txt break.before="1">See glossary, definition <defterm guid="_06a31703-36a9-4d30-9333-02681186866f" type="mention">backflow prevention device</defterm>.</txt></block></note><historynote><txt break.before="1">def <defterm guid="_cf43fe4d-087e-4f07-b031-69467307417e" type="mention">dual check valve with an atmospheric port</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.dualreticulatedwatersupply_" guid="_e78b45d0-0847-4128-bd0e-e32f904b6b78" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.dualreticulatedwatersupply" guid="_6f46c55a-b994-4749-9e0f-bacae036c46d" type="definition">dual reticulated water supply</defterm>, for a building, means water supply for the building consisting of both a network utility operator’s supply and recycled water.</txt><historynote><txt break.before="1">def <defterm guid="_1f808317-87a6-4254-9d8b-15f8da3a0b1c" type="mention">dual reticulated water supply</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.effluent_" guid="_bf87487c-ffa4-4f84-84d9-edb4f6c003e6" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.effluent" guid="_eb16f7e6-dbc9-40b8-a81d-ef2e21afb6cf" type="definition">effluent</defterm> see glossary.</txt></definition><definition id="sch.6-def.emergencywork_" guid="_2835d2fa-fc10-4f5f-82d1-b3a085e16a39" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.emergencywork" guid="_0125cdf3-f809-4255-bd9c-158207bb57b9" type="definition">emergency work</defterm> means plumbing or drainage work that must, because of a failure in plumbing or drainage, be performed to stop a continuing risk to health and safety or damage to property.</txt></definition><definition id="sch.6-def.evaporativeairconditioner_" guid="_984720b0-51b7-41a8-aa85-6622a2d26da7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.evaporativeairconditioner" guid="_0f5e23b8-164f-4e4a-b534-fb2c26be23f9" type="definition">evaporative air conditioner</defterm> see glossary.</txt></definition><definition id="sch.6-def.fall_" guid="_97646dc2-cf68-48ad-aa8a-13ab641ff8c1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.fall" guid="_305174f4-8c3f-412f-a759-b7e88e3f2db2" type="definition">fall</defterm> see glossary.</txt></definition><definition id="sch.6-def.fill_" guid="_554268e4-1a55-433c-b275-601272c8a5e8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.fill" guid="_1e342bb6-d7ce-4e4b-92ae-43ec9b2c0de4" type="definition">fill</defterm> see glossary.</txt></definition><definition id="sch.6-def.filter_" guid="_0b89532d-a2de-49c8-9696-82ff06b621bf" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.filter" guid="_3588436e-9f46-4b23-bb00-57ac440c2544" type="definition">filter</defterm> see glossary.</txt></definition><definition id="sch.6-def.fireservice_" guid="_e81f3ad3-bce0-4c48-85e4-80cbf5c42ca3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.fireservice" guid="_046081c6-be6b-40ab-8fb3-dbaf13084d20" type="definition">fire service</defterm> see glossary.</txt></definition><definition id="sch.6-def.fitting_" guid="_489ec092-b327-4374-972c-27130ed7c1b3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.fitting" guid="_33c0433c-7651-4660-b4d9-3366f79a0245" type="definition">fitting</defterm> see glossary.</txt></definition><definition id="sch.6-def.fixture_" guid="_83487781-42ea-4247-b022-9a8277658ee5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.fixture" guid="_528e37db-3bda-4f0d-aba0-7d5d183bf84e" type="definition">fixture</defterm> see glossary.</txt></definition><definition id="sch.6-def.fixturetrap_" guid="_680f006d-1920-4717-8f12-0116ac1df31f" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.fixturetrap" guid="_ec1d3b65-fe05-4b77-8819-15c4cf480e80" type="definition">fixture trap</defterm> see glossary.</txt></definition><definition id="sch.6-def.floatvalve_" guid="_6d440314-0ffc-43d1-a9fb-2d8e412ff93c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.floatvalve" guid="_d9b7bb11-d401-444f-a67c-acd9eb9be334" type="definition">float valve</defterm> see glossary.</txt></definition><definition id="sch.6-def.floortypeurinal_" guid="_5bcf97a9-c480-4f67-b9d8-2bf0316c24f9" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.floortypeurinal" guid="_0edbeb4b-4bca-4cde-8b59-0140280a6144" type="definition">floor type urinal</defterm> means a urinal that has a channel at or near floor level.</txt></definition><definition id="sch.6-def.floorwastegully_" guid="_aa4e0a77-69a3-4b53-9e2d-b05266cff1b1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.floorwastegully" guid="_3866a745-12bd-4b3e-b09d-5d4b2ce20820" type="definition">floor waste gully</defterm> see glossary.</txt></definition><definition id="sch.6-def.glossary_" guid="_cf1fe5bd-e0a1-482a-a115-7d70eda13329" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.glossary" guid="_afa6ea86-6b15-4f5f-9a08-1b24e5b67134" type="definition">glossary</defterm> see <intref refid="sec.5" check="valid" target.guid="_d8ae99cc-f17d-4a50-bf34-efcec8227ab4">section&#160;5</intref><intref refid="sec.5-ssec.2" check="valid" target.guid="_cd6a0a9d-e062-4b25-9b79-83ae6085f7f4">(2)</intref>.</txt></definition><definition id="sch.6-def.grade_" guid="_9518970f-4fb3-4957-aa57-0c84ca64ecfa" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.grade" guid="_9e7cd85d-415b-46e2-8d8d-f614fa807b6f" type="definition">grade</defterm> see glossary.</txt></definition><definition id="sch.6-def.greasearrestor_" guid="_f5f66674-8471-45bc-b663-6075fef0a34a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.greasearrestor" guid="_c05e2a07-bb5e-45ec-8531-dbc6ab6b76e9" type="definition">grease arrestor</defterm> means an arrestor intended only, or at least primarily, for grease.</txt></definition><definition id="sch.6-def.groundlevel_" guid="_d87b7753-64bc-4909-a32a-093749d107ff" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.groundlevel" guid="_9e1e7049-2b1c-4ec7-9715-40b8caacae33" type="definition">ground level</defterm> see glossary.</txt></definition><definition id="sch.6-def.imperviousmaterial_" guid="_f9e7d544-daa1-4427-a704-08c78579d22b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.imperviousmaterial" guid="_3151b8d8-bd4d-41e8-aeaf-8e525a66a3f0" type="definition">impervious material</defterm> means material that—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.imperviousmaterial-para1.a" guid="_e6e843f3-4e6b-4428-93e8-9241cc1dd782" provision.type="other"><no>(a)</no><block><txt break.before="0">water does not ordinarily penetrate; and</txt></block></li><li id="sch.6-def.imperviousmaterial-para1.b" guid="_9c72a40e-95f1-4820-8a39-9abb8f4233e1" provision.type="other"><no>(b)</no><block><txt break.before="0">in the circumstances of its installation and use, is resistant to degradation caused by contact with sewage and trade waste.</txt></block></li></list></definition><definition id="sch.6-def.inspectionopening_" guid="_6616642b-a99f-4936-847b-8c1cdfd5173c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.inspectionopening" guid="_d544a268-848a-44bc-88d4-27e456dc7b5d" type="definition">inspection opening</defterm> see glossary.</txt></definition><definition id="sch.6-def.installation_" guid="_26352f89-acb9-42f4-a348-5ed65054813c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.installation" guid="_af2a591d-ea72-4944-96ef-b99990313f4e" type="definition">installation</defterm> see glossary.</txt></definition><definition id="sch.6-def.integraltrap_" guid="_b26f31ac-e19b-4db7-abea-c71d4c1ffaf5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.integraltrap" guid="_db713f73-5b3c-4bda-b9d8-be820eddb954" type="definition">integral trap</defterm> see glossary.</txt></definition><definition id="sch.6-def.invert_" guid="_d8b87496-f979-44fd-8cfb-c51a549029ed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.invert" guid="_5413f609-3cb4-4866-b4b9-9d4ec8e7145f" type="definition">invert</defterm> see glossary.</txt></definition><definition id="sch.6-def.invertlevel_" guid="_c8f140be-9a52-4342-9846-e0c8a879cb2d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.invertlevel" guid="_9d0b04ae-e232-4cae-967b-dd0d9df9ee9a" type="definition">invert level</defterm> see glossary.</txt></definition><definition id="sch.6-def.isolatingvalve_" guid="_31ede3eb-5c09-4e3d-af5e-032bc985cbdb" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.isolatingvalve" guid="_da8ecd21-7e09-4117-b8d9-93d832ac08d0" type="definition">isolating valve</defterm> see glossary.</txt></definition><definition id="sch.6-def.joint_" guid="_aff921cd-8884-47f6-8a14-2a8001c22c71" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.joint" guid="_fe1b0314-31a3-44dd-97f0-e31e19d6df12" type="definition">joint</defterm> see glossary.</txt></definition><definition id="sch.6-def.jumpervalve_" guid="_1e717d5c-0172-4e5a-9b47-17856bbfb338" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.jumpervalve" guid="_c2bf060b-ef57-4233-964c-001a3d322b71" type="definition">jumper valve</defterm> see glossary.</txt></definition><definition id="sch.6-def.localplanninginstrument_" guid="_cfa1c5ca-d650-4ed9-9cb2-e9cceb5cc492" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.localplanninginstrument" guid="_6e39aa16-130a-4be7-85f3-1f5ec6ba02f8" type="definition">local planning instrument</defterm> see the Planning Act, <intref refid="sec.8" check="valid" target.guid="_4835b85e-08f2-420e-9875-fe5d7c0f592d">section&#160;8</intref><intref refid="sec.8-ssec.3" check="invalid">(3)</intref>.</txt><historynote><txt break.before="1">def <defterm guid="_1abab625-a830-4050-9dcd-e353fa8d1e45" type="mention">local planning instrument</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2009-0280" target.version.series="733c849a-1ebf-43d1-8c69-932e3c2fa135" valid.date="as.made" check="valid">2009 SL&#160;No.&#160;280</legref> <legref jurisd="QLD" type="subordleg" refid="sec.123" target.doc.id="sl-2009-0280" target.version.series="733c849a-1ebf-43d1-8c69-932e3c2fa135" valid.date="as.made" check="invalid">s&#160;123</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.3" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(3)</legref></txt></historynote><historynote><txt break.before="1">sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2017-0103" target.version.series="aabfcf9a-08e0-4b5f-9217-29d2cd8b8f45" valid.date="as.made" check="valid">2017 SL&#160;No.&#160;103</legref> <legref jurisd="QLD" type="subordleg" refid="sec.121" target.doc.id="sl-2017-0103" target.version.series="aabfcf9a-08e0-4b5f-9217-29d2cd8b8f45" valid.date="as.made" check="valid" target.guid="_8f844b0a-8f75-4859-821e-666b7998f642">s&#160;121</legref></txt></historynote></definition><definition id="sch.6_-oc.4" guid="_4d4ce741-4c6f-41fc-b28e-2855253b136b" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.MAP" guid="_3eb58000-d6ba-43fc-9e5e-cfdeeb13dff0" type="mention">MAP</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_bb25f4d5-c637-4c1e-96aa-c3c07429634b" type="mention">MAP</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6_-oc.5" guid="_c36ed7ee-d96d-465a-94a8-a2bd93ac5557" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.MAPcertification" guid="_2d264dc4-fff6-4192-9f1f-60a6bacc5059" type="mention">MAP certification</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_7fd68b58-2d58-4486-8855-a6c4b508f1bc" type="mention">MAP certification</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6_-oc.6" guid="_eceeb646-dcdd-4ac1-a112-8f045488f694" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.meter" guid="_a16a5bf8-d2c2-40b6-8be4-792abaea616d" type="mention">meter</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_03969338-ddee-4531-b26e-6f78bcfdf7aa" type="mention">meter</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="valid">2007 SL&#160;No.&#160;328</legref> <legref jurisd="QLD" type="subordleg" refid="sec.15" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="invalid">s&#160;15</legref><legref jurisd="QLD" type="subordleg" refid="sec.15-ssec.1" target.doc.id="sl-2007-0328" target.version.series="b5c412ef-ab16-4c22-b9d5-7977c70affae" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.networkutilityoperatorssupply_" guid="_87e2ace8-120d-4c9e-af7f-51431da0c365" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.networkutilityoperatorssupply" guid="_b9c42f82-b2bc-4e2d-8d42-0b1492ec52c0" type="definition">network utility operator’s supply</defterm> see glossary.</txt><note id="sch.6-def.networkutilityoperatorssupply-note" guid="_98c4cd3d-c325-4c2a-af78-1a75d2b5151b" type="example"><heading id="sch.6-def.networkutilityoperatorssupply-note-he" guid="_87f1a37a-06c2-49dc-93ce-36c77bc199c1">Note—</heading><block><txt break.before="1">See glossary, definition <defterm guid="_0aaf85b0-ffcb-4aa4-9086-63b2f83a2086" type="mention">water supply</defterm>.</txt></block></note><historynote><txt break.before="1">def <defterm guid="_8200aee6-6a6c-4e00-bac9-533191028840" type="mention">network utility operator’s supply</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6_-oc.7" guid="_76528f1d-05ed-4b7a-a437-4ad617bc62f1" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.notifiableminorwork" guid="_0c352905-dc2c-411c-ac84-612eb40b095f" type="mention">notifiable minor work</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_9909d78b-2769-4fe8-8941-9ada50ca6ec6" type="mention">notifiable minor work</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.1" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.onsitesewerageapplicationarea_" guid="_adc7fc35-d2c8-4fd7-972b-abdb20e617d6" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.onsitesewerageapplicationarea" guid="_573385b6-917b-446b-bb65-e3555dc47d6b" type="definition">on-site sewerage application area</defterm>, for an on-site sewage treatment plant on premises, means a part of the premises, commonly called a ‘land application area’, to which effluent from the on-site sewage treatment plant is disposed.</txt><historynote><txt break.before="1">def <defterm guid="_5920d26a-1dc8-4306-ae94-df409b9e0d05" type="mention">on-site sewerage application area</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6_-oc.8" guid="_0b933085-de39-412f-b45a-ef0a8dc33c57" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.otherminorwork" guid="_9e004607-4043-4e01-a7f8-9c1d245745b5" type="mention">other minor work</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_3437b0c5-44da-476a-9667-6a9b70d9711a" type="mention">other minor work</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.1" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.outlet_" guid="_3c184916-dc8f-4c20-bf1a-2fd1a53a8ab2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.outlet" guid="_83d87533-57e0-4f1e-910a-26f712e89c65" type="definition">outlet</defterm> see glossary.</txt></definition><definition id="sch.6_-oc.9" guid="_d73039d2-c505-400c-b70b-1e7c3f15abda" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.part12" guid="_45a97b22-3d1f-4d61-b0a0-c296271d56e7" type="mention">part&#160;1.2</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_0b07d08a-8379-44c4-989f-bb33f5c44e18" type="mention">part&#160;1.2</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6_-oc.10" guid="_ddd1298e-2cba-4b20-8ae7-21aba661f72d" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.part42" guid="_dcb5f96f-a9e7-49d6-a584-7c839d164489" type="mention">part&#160;4.2</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_b81f59dc-72c6-4ae2-bb2f-d6249148ba7b" type="mention">part&#160;4.2</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.PCA_" guid="_b65d6f8e-ff52-4c4b-a0a3-6a2cb0014285" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.PCA" guid="_96f58884-0444-43a8-a49e-fe9de6319b04" type="definition">PCA</defterm> means the Plumbing Code of Australia.</txt><historynote><txt break.before="1">def <defterm guid="_ab4b336e-a6e1-4d98-bda1-95b2a951412d" type="mention">PCA</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.pipe_" guid="_3dbd5bc5-ccba-4ef3-9a5e-86c15f078d57" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.pipe" guid="_03a030f8-cefb-4c90-8610-d4b6d8f38f28" type="definition">pipe</defterm> see glossary.</txt></definition><definition id="sch.6-def.piping_" guid="_4c17b613-cd64-4818-8114-45d591da7041" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.piping" guid="_0f2d4aec-1647-4e72-920f-f6b6b8ede337" type="definition">piping</defterm> see glossary.</txt><historynote><txt break.before="1">def <defterm guid="_c0af88ac-3aa3-4a4f-ad76-08683aac711e" type="mention">piping</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.plug_" guid="_c6fe8cfc-10bb-4fcd-90b6-c177d79ff159" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.plug" guid="_4bac41cd-c7aa-43a5-9bd1-aaf649f5e4f4" type="definition">plug</defterm> see glossary.</txt></definition><definition id="sch.6-def.PlumbingCodeofAustralia_" guid="_0c2cfad7-73a6-4ece-bdf4-79b9c1da5a2f" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.PlumbingCodeofAustralia" guid="_831b0b1d-2f3a-42cf-b0c8-52c8a9085ead" type="definition">Plumbing Code of Australia</defterm> means the document in force from time to time called ‘National Construction Code volume 3—Plumbing Code of Australia’ produced for all State governments by the Australian Building Codes Board.</txt><historynote><txt break.before="1">def <defterm guid="_2caf8dbd-fac0-4d53-9c49-2e4451686362" type="mention">Plumbing Code of Australia</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0048" target.version.series="74803e6f-a53a-4569-a1a3-f8057b172012" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;48</legref> <legref jurisd="QLD" type="subordleg" refid="sec.6" target.doc.id="sl-2011-0048" target.version.series="74803e6f-a53a-4569-a1a3-f8057b172012" valid.date="as.made" check="invalid">s&#160;6</legref></txt></historynote></definition><definition id="sch.6-def.plumbingordrainageitem_" guid="_6b9c60c2-6864-4d74-9f87-2e324e338bd7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.plumbingordrainageitem" guid="_553d0258-a5a5-4ef4-8333-ce9eeec5ef34" type="definition">plumbing or drainage item</defterm> means any apparatus, fitting, fixture or pipe used for plumbing or drainage.</txt></definition><definition id="sch.6-def.premisesgroup_" guid="_331ee6d9-6ffc-4540-a5c7-0419276bc406" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.premisesgroup" guid="_cfe7020d-1c6a-415e-a9c1-ddc5ded8cf2b" type="definition">premises group</defterm> means the land comprised in 2 or more premises, all the owners of which have mutual rights and obligations under the <legref jurisd="QLD" type="act" target.doc.id="act-1997-028" target.version.series="64bf56de-be45-4387-8ada-9b4f75f32515" check="valid"><name emphasis="yes">Body Corporate and Community Management Act 1997</name></legref> or the <legref jurisd="QLD" type="act" target.doc.id="act-1980-042" target.version.series="db1baf67-e0e9-4aaa-88d6-6b0407d404c3" check="valid"><name emphasis="yes">Building Units and Group Titles Act 1980</name></legref> for their respective ownerships, and includes the common property forming part of—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.premisesgroup-para1.a" guid="_09624e2a-f8f5-43a8-8603-93f2c51721b0" provision.type="other"><no>(a)</no><block><txt break.before="0">if the premises are lots included in a community titles scheme under the <legref jurisd="QLD" type="act" target.doc.id="act-1997-028" target.version.series="64bf56de-be45-4387-8ada-9b4f75f32515" check="valid"><name emphasis="yes">Body Corporate and Community Management Act 1997</name></legref>—the scheme land under that Act for the scheme; or</txt></block></li><li id="sch.6-def.premisesgroup-para1.b" guid="_9d2c5d6f-2008-4691-8929-7a2a0e3d6ccd" provision.type="other"><no>(b)</no><block><txt break.before="0">if the premises are lots under the <legref jurisd="QLD" type="act" target.doc.id="act-1980-042" target.version.series="db1baf67-e0e9-4aaa-88d6-6b0407d404c3" check="valid"><name emphasis="yes">Building Units and Group Titles Act 1980</name></legref>—the parcel of which the premises form part.</txt></block></li></list></definition><definition id="sch.6-def.premisesgroupmain_" guid="_c080a50a-a4cc-4ea4-a5bf-0c2ab4ae6209" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.premisesgroupmain" guid="_94bd4d0c-053e-4633-b658-f05bc15245c9" type="definition">premises group main</defterm> see <intref refid="sec.34" check="valid" target.guid="_18529fed-9d78-4b16-aee2-e3a9c657cc7b">section&#160;34</intref><intref refid="sec.34-ssec.3" check="valid" target.guid="_6785550f-3d49-45d2-a5a9-f36b7f2d8edc">(3)</intref><intref refid="sec.34-ssec.3-para1.a" check="valid" target.guid="_e320286f-6acf-499f-9248-76da71bc207a">(a)</intref>.</txt></definition><definition id="sch.6-def.premisesgroupsewer_" guid="_41ebe5cf-e1ea-4bd4-b23c-c10d659bc364" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.premisesgroupsewer" guid="_7a530e38-17bd-43ae-a7d8-9a7702e57f9b" type="definition">premises group sewer</defterm> see <intref refid="sec.35" check="valid" target.guid="_09dd34ca-939a-4edb-9e79-3f4acb6770b9">section&#160;35</intref><intref refid="sec.35-ssec.3" check="valid" target.guid="_ee17c9fb-7cfe-42d2-9651-18c4373d7f60">(3)</intref>.</txt></definition><definition id="sch.6-def.premisesmain_" guid="_0d512b05-5f63-4dfb-b02d-a0dd91a69367" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.premisesmain" guid="_c98b4305-0312-48f9-9534-3d84cc286aeb" type="definition">premises main</defterm> see <intref refid="sec.34" check="valid" target.guid="_18529fed-9d78-4b16-aee2-e3a9c657cc7b">section&#160;34</intref><intref refid="sec.34-ssec.2" check="valid" target.guid="_1a947b44-db38-4afe-8e0c-a50e87249731">(2)</intref><intref refid="sec.34-ssec.2-para1.a" check="valid" target.guid="_f29f429e-c3c8-4044-a1f8-da0560e4f1be">(a)</intref>.</txt></definition><definition id="sch.6-def.premisessewer_" guid="_5f2c1a5d-ec9f-43e0-84d5-e829d9786c8d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.premisessewer" guid="_3b448f63-3dd7-4dc7-82b2-ce13790f63ae" type="definition">premises sewer</defterm> see <intref refid="sec.35" check="valid" target.guid="_09dd34ca-939a-4edb-9e79-3f4acb6770b9">section&#160;35</intref><intref refid="sec.35-ssec.2" check="valid" target.guid="_ce3daa35-b61e-44d3-aaf2-b523c5aa2bc8">(2)</intref>.</txt></definition><definition id="sch.6-def.pressuretypevacuumbreaker_" guid="_8925c880-ff70-4002-aaa1-777271fe7007" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.pressuretypevacuumbreaker" guid="_09728d0a-4364-474e-939f-5a78609c2b71" type="definition">pressure type vacuum breaker</defterm> see glossary.</txt></definition><definition id="sch.6-def.propertyservice_" guid="_4c55217b-d630-4032-9ca6-1a1f50ff12b0" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.propertyservice" guid="_e13289dd-8ef4-458a-8c82-3ffef369547b" type="definition">property service</defterm> means a short length of pipe installed for connecting premises to a water main, whether or not built to the standard of a water main.</txt></definition><definition id="sch.6-def.pump_" guid="_3248963a-b616-43bd-b29c-7e8e0fc9aa35" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.pump" guid="_4ff209c1-4ba4-49e3-9f81-a20921b3c6c5" type="definition">pump</defterm> see glossary.</txt></definition><definition id="sch.6-def.QDC_" guid="_c93a9908-33b7-488a-9dff-70c84868c6d3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.QDC" guid="_a23670f6-8a88-427d-b1d2-d316e2de75fd" type="definition">QDC</defterm> see the <legref jurisd="QLD" type="act" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid"><name emphasis="yes">Building Act 1975</name></legref>, <legref jurisd="QLD" type="act" refid="sch.2" target.doc.id="act-1975-011" target.version.series="d9daab5f-059e-488d-ba00-96f36d4a1fe5" check="valid" target.guid="_eb2bfe4c-13cb-46ab-9188-07fe0a4b31c8">schedule&#160;2</legref>.</txt><historynote><txt break.before="1">def <defterm guid="_c23066f6-01fa-4c91-8994-8dfb0b1f4687" type="mention">QDC</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.QPWcode_" guid="_57505278-cbda-4ea1-a842-91756184d367" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.QPWcode" guid="_272d7a5a-ccbd-4567-a230-d2eff4e2a237" type="definition">QPW code</defterm> see <intref refid="sec.4A" check="valid" target.guid="_e37cd400-bbc8-474c-afe4-2f9420f17945">section&#160;4A</intref>.</txt><historynote><txt break.before="1">def <defterm guid="_7400d2a2-8964-4bf8-ae8c-89579d02ddb8" type="mention">QPW code</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;2</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="invalid">s&#160;4</legref><legref jurisd="QLD" type="subordleg" refid="sec.4-ssec.1" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.QueenslandPlumbingandWastewaterCode_" guid="_4882c2a3-2aff-414e-a6df-66d6d3c52a0a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.QueenslandPlumbingandWastewaterCode" guid="_52bf8681-2b3b-4e77-a9a9-0d688b3c0455" type="definition">Queensland Plumbing and Wastewater Code</defterm> see <intref refid="sec.4A" check="valid" target.guid="_e37cd400-bbc8-474c-afe4-2f9420f17945">section&#160;4A</intref>.</txt><historynote><txt break.before="1">def <defterm guid="_cae48da8-ebbc-4c18-a7e7-4d8a29c672f9" type="mention">Queensland Plumbing and Wastewater Code</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.2" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(2)</legref></txt></historynote><historynote><txt break.before="1">amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="valid">2011 SL&#160;No.&#160;2</legref> <legref jurisd="QLD" type="subordleg" refid="sec.4" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="invalid">s&#160;4</legref><legref jurisd="QLD" type="subordleg" refid="sec.4-ssec.2" target.doc.id="sl-2011-0002" target.version.series="159b9346-6deb-470c-bee0-4ca0705b1a91" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.rectificationnotice_" guid="_c2950dab-e4af-49f5-bf69-531dbd093703" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.rectificationnotice" guid="_8afc5083-9b67-40f0-ada8-1c3e2f42b8f0" type="definition">rectification notice</defterm>, for <intref refid="pt.3" check="valid" target.guid="_7a1ea24c-8d8e-4046-b714-b561768fc7ee">part&#160;3</intref>, <intref refid="pt.3-div.5" check="valid" target.guid="_db00cb77-6853-42b7-8265-5b32c5a25eff">division&#160;5</intref>, see <intref refid="sec.29B" check="valid" target.guid="_967c71d9-d6cd-40ae-8c33-3853803973f0">section&#160;29B</intref>.</txt><historynote><txt break.before="1">def <defterm guid="_0d980e7e-514c-4dee-8a65-b623590ba591" type="mention">rectification notice</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.recycledwater_" guid="_f0ec31d9-c4e5-46f8-b2a4-20355663109c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.recycledwater" guid="_62920467-3043-47b6-9efd-f6a1a0bc4375" type="definition">recycled water</defterm> see glossary.</txt><note id="sch.6-def.recycledwater-note" guid="_d788a2e1-8f30-4baa-8f06-42aeed930c6d" type="example"><heading id="sch.6-def.recycledwater-note-he" guid="_808d498e-2683-42da-9c71-d1fa332a5a74">Note—</heading><block><txt break.before="1">See glossary, definition <defterm guid="_9bc8deec-0712-4c2d-9731-447f0d398019" type="mention">water supply</defterm>.</txt></block></note><historynote><txt break.before="1">def <defterm guid="_fe935c2f-813f-4e6f-bfe0-b9936212ce89" type="mention">recycled water</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.reducedpressurezonedevice_" guid="_32737eed-b9f1-4fd0-a502-7fae02a4c4ec" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.reducedpressurezonedevice" guid="_49e15b6d-8ca0-40d6-b881-d5e63b08dd95" type="definition">reduced pressure zone device</defterm> see glossary.</txt></definition><definition id="sch.6-def.registeredairgap_" guid="_c74568a1-e9d5-465c-acd5-4e696816d604" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.registeredairgap" guid="_90501194-630b-4fbc-9e1e-1acb94a0531a" type="definition">registered air gap</defterm> means an air gap complying with the requirements for a registered air gap in AS/NZS 3500.1:2003.</txt><historynote><txt break.before="1">def <defterm guid="_9de316e1-71b7-4999-97d0-2d7ffce37466" type="mention">registered air gap</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.3" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(3)</legref></txt></historynote></definition><definition id="sch.6-def.registeredbreaktank_" guid="_cf40bb9c-4add-4324-a634-12d00398597c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.registeredbreaktank" guid="_2c89cf43-feea-4caa-a03e-4efb3f4f90da" type="definition">registered break tank</defterm> means a break tank complying with the requirements for a registered break tank in AS/NZS 3500.1:2003.</txt><historynote><txt break.before="1">def <defterm guid="_5cb8833f-36af-437b-a525-e4ce18d2735c" type="mention">registered break tank</defterm> amd <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.3" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(3)</legref></txt></historynote></definition><definition id="sch.6-def.remotearea_" guid="_5ad49ae9-d0db-43ca-be5a-d9711cac86bb" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.remotearea" guid="_636e7207-ded7-4a1c-8071-5ed7a88492a2" type="definition">remote area</defterm> see <intref refid="sec.25" check="valid" target.guid="_45b0ae2b-e409-47ee-b66b-4b2a20dfc770">section&#160;25</intref>.</txt></definition><definition id="sch.6-def.replacing_" guid="_21a0abed-96e2-4e0f-a4b9-9bdc320dcbd9" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.replacing" guid="_51a2b70e-046a-4a66-ac97-4f8229d2c996" type="definition">replacing</defterm>, of a plumbing or drainage item, means removing the item from a place and installing a new item of a similar type in the same place.</txt></definition><definition id="sch.6-def.responsibleperson_" guid="_2feb02c7-7184-4e6f-859e-029d965b10c7" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.responsibleperson" guid="_af621d7b-4612-4e09-a4dc-1281972b5972" type="definition">responsible person</defterm>, for compliance assessable work, notifiable work or minor work, means a person who—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.responsibleperson-para1.a" guid="_0b90ad1c-07ac-4082-ab12-9424527514bd" provision.type="other"><no>(a)</no><block><txt break.before="0">is a licensed person for the work; and</txt></block></li><li id="sch.6-def.responsibleperson-para1.b" guid="_43c998e8-6124-47b0-b02f-911602f0880f" provision.type="other"><no>(b)</no><block><txt break.before="0">performs, directs the performance of, or supervises, the work.</txt></block></li></list><historynote><txt break.before="1">def <defterm guid="_64dd985f-9ba7-4c02-823a-1573f9294b7a" type="mention">responsible person</defterm> sub <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.1" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(1)</legref>–<legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref>; <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="valid">2013 SL&#160;No.&#160;138</legref> <legref jurisd="QLD" type="subordleg" refid="sec.29" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">s&#160;29</legref><legref jurisd="QLD" type="subordleg" refid="sec.29-ssec.1" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">(1)</legref>–<legref jurisd="QLD" type="subordleg" refid="sec.29-ssec.2" target.doc.id="sl-2013-0138" target.version.series="f4be112a-7cf8-4ad1-bae4-374715e5b412" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.riser_" guid="_78ac2230-8dfa-4a2d-8e68-e48a3df57b3d" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.riser" guid="_c72adfc2-511a-4877-8cb9-12b7b096c0b9" type="definition">riser</defterm> see glossary.</txt></definition><definition id="sch.6_-oc.11" guid="_1fe3faeb-6f28-4528-a8d2-150fba509909" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.sanitarydrainage" guid="_fd5f94e0-5fc9-4be2-b983-206dedac404f" type="mention">sanitary drainage</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_9b8a809e-07a6-4184-bb0a-5df4774b1808" type="mention">sanitary drainage</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.sanitaryplumbing_" guid="_810625b2-958a-4f48-8fe9-7ea297d2eee6" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.sanitaryplumbing" guid="_88de9662-4d12-4a0f-beb1-d71b7cce10ea" type="definition">sanitary plumbing</defterm> means an apparatus, fitting, fixture or pipe, above ground level, that carries sewage to a sanitary drain.</txt></definition><definition id="sch.6-def.serviceprovider_" guid="_407a808c-5789-45df-9fc2-21fdda6a2645" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.serviceprovider" guid="_d396e231-3759-4c2f-a29c-19fe84212077" type="definition">service provider</defterm> has the meaning given under the <legref jurisd="QLD" type="act" target.doc.id="act-2000-034" target.version.series="e70e5508-125c-4cf6-a85e-c31ed22b7104" check="valid"><name emphasis="yes">Water Act 2000</name></legref>.</txt></definition><definition id="sch.6_-oc.12" guid="_bf509ec1-b0a3-4178-95d1-b08638d1d231" status="repealed" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.sewage" guid="_3a39d0cf-41c4-447b-85e2-d591c361dde3" type="mention">sewage</defterm> ...</txt><historynote><txt break.before="1">def <defterm guid="_cecdf889-ae9d-4c06-a5a2-a6f37891a811" type="mention">sewage</defterm> om <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="valid">2005 SL&#160;No.&#160;323</legref> <legref jurisd="QLD" type="subordleg" refid="sec.45" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">s&#160;45</legref><legref jurisd="QLD" type="subordleg" refid="sec.45-ssec.1" target.doc.id="sl-2005-0323" target.version.series="4f0d526c-0bc4-46a2-add3-cc59937b58a0" valid.date="as.made" check="invalid">(1)</legref></txt></historynote></definition><definition id="sch.6-def.sink_" guid="_7ceeaf7b-8a49-402d-aa39-643a67133657" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.sink" guid="_a7c3fb4a-aea1-4ff6-943c-fc13e39ed82b" type="definition">sink</defterm> see glossary.</txt></definition><definition id="sch.6-def.siphon_" guid="_6a841e82-4561-4a0b-89dc-41eabd0bcbf1" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.siphon" guid="_a795ff45-61d1-4c10-86e6-eacfafb1e0f4" type="definition">siphon</defterm> see glossary.</txt></definition><definition id="sch.6-def.slaburinal_" guid="_2cf9dc2c-387f-44f6-b574-0f41477d9a06" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.slaburinal" guid="_82a36c4f-47d0-4706-869e-a4d119bae816" type="definition">slab urinal</defterm> see glossary.</txt></definition><definition id="sch.6-def.soilpipe_" guid="_43db1a76-6a41-4c9d-95c2-35f2e1a9a950" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.soilpipe" guid="_2a0d3f59-e220-4b03-b55e-ad5d59d8bc1f" type="definition">soil pipe</defterm> see glossary.</txt></definition><definition id="sch.6-def.soilstack_" guid="_5deb76af-a222-4158-b5b3-0b5a6ced9853" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.soilstack" guid="_d4a6f114-0a78-43ab-8cae-a019f627750f" type="definition">soil stack</defterm> see glossary.</txt></definition><definition id="sch.6-def.stack_" guid="_e77a2f1e-8f1a-4480-a983-5f2c5774dd10" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.stack" guid="_b544fcc2-2710-4d4e-8b53-e5a62765259a" type="definition">stack</defterm> see glossary.</txt></definition><definition id="sch.6-def.supplypipe_" guid="_94306e31-fb22-4ff7-be39-c75984ffd7c3" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.supplypipe" guid="_88374e1c-66c5-4859-8b8a-57206e4b512b" type="definition">supply pipe</defterm> means a pipe for supplying and conveying water within premises.</txt></definition><definition id="sch.6-def.tank_" guid="_97410e14-d022-4b16-8169-aca7d25423f8" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.tank" guid="_0315af2c-3c2d-4ee4-8842-3286ca71f496" type="definition">tank</defterm> see glossary.</txt></definition><definition id="sch.6-def.tap_" guid="_e64cc6b2-4258-44ba-92a2-d320151802de" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.tap" guid="_f7366046-28c9-4635-b4c5-51cdb0e00a7e" type="definition">tap</defterm> see glossary.</txt></definition><definition id="sch.6-def.temperaturecontroldevice_" guid="_26911afe-3c79-4891-8bec-15d39bcd91b0" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.temperaturecontroldevice" guid="_3dcb4592-6156-4e9b-8ff7-f4c7109a3b13" type="definition">temperature control device</defterm> means a tempering valve or a thermostatic mixing valve.</txt><historynote><txt break.before="1">def <defterm guid="_67752598-9ab7-4e50-8495-678b44194ed3" type="mention">temperature control device</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.temperingvalve_" guid="_ac039fb2-9529-4d6e-a6ae-c6a411460489" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.temperingvalve" guid="_c43a0df8-142a-4393-b877-555f9e9553b3" type="definition">tempering valve</defterm> see glossary.</txt><historynote><txt break.before="1">def <defterm guid="_b487a18a-4b4b-4a86-8677-fb4234fbf974" type="mention">tempering valve</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.test_" guid="_aa1c8c0b-b880-40d9-a842-8935fa3ee16c" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.test" guid="_b323f157-9d93-4137-89b3-642c43d7d316" type="definition">test</defterm> see glossary.</txt></definition><definition id="sch.6-def.testablebackflowpreventiondevice_" guid="_5a93cee2-2da6-46d0-b5c7-336eb1374944" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.testablebackflowpreventiondevice" guid="_ee8b85eb-0acb-4b92-ab76-139c5cb60ac5" type="definition">testable backflow prevention device</defterm> means any of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.testablebackflowpreventiondevice-para1.a" guid="_3579d6e0-9e77-4644-adc7-07a7a068148b" provision.type="other"><no>(a)</no><block><txt break.before="0">a double check valve;</txt></block></li><li id="sch.6-def.testablebackflowpreventiondevice-para1.b" guid="_1d666951-79d6-45b1-bfa6-e1bf4fd3fc8d" provision.type="other"><no>(b)</no><block><txt break.before="0">a pressure type vacuum breaker;</txt></block></li><li id="sch.6-def.testablebackflowpreventiondevice-para1.c" guid="_51f582f5-c1bf-42e8-9de2-4e920cbc6a80" provision.type="other"><no>(c)</no><block><txt break.before="0">a reduced pressure zone device;</txt></block></li><li id="sch.6-def.testablebackflowpreventiondevice-para1.d" guid="_acae5b37-9c37-41db-adab-08d2c9153c17" provision.type="other"><no>(d)</no><block><txt break.before="0">a registered air gap;</txt></block></li><li id="sch.6-def.testablebackflowpreventiondevice-para1.e" guid="_e73b3848-268f-4e9d-8a54-d50627d8c905" provision.type="other"><no>(e)</no><block><txt break.before="0">a registered break tank.</txt></block></li></list></definition><definition id="sch.6-def.testablesinglecheckvalve_" guid="_266a755c-0a8c-4dd1-9b6b-3e278cba6185" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.testablesinglecheckvalve" guid="_590ffeb9-243d-4bb8-9c06-ef71cdf96777" type="definition">testable single check valve</defterm> means a device to prevent backflow caused by backpressure that has 1 force loaded non-return valve and incorporates specific test points for in-service testing.</txt></definition><definition id="sch.6-def.thermostaticmixingvalve_" guid="_4ef70c7d-01dc-4a2c-b5a2-5e8e74f3fc43" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.thermostaticmixingvalve" guid="_8481a758-3165-489b-beb7-59c1da02c111" type="definition">thermostatic mixing valve</defterm> see glossary.</txt><historynote><txt break.before="1">def <defterm guid="_07dfefe6-eb36-4c88-9f34-6bfe40a1bdd3" type="mention">thermostatic mixing valve</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.tradewaste_" guid="_97eb8dd8-8978-42d3-8cf8-a1ca8b9dfd8e" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.tradewaste" guid="_8b97800c-31fb-4318-995b-2fd6d2bcfc20" type="definition">trade waste</defterm> means water-borne waste from business, trade or manufacturing premises, other than—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.tradewaste-para1.a" guid="_717e4328-e1c2-46ee-8d25-b6056501848a" provision.type="other"><no>(a)</no><block><txt break.before="0">waste that is a prohibited substance; and</txt></block></li><li id="sch.6-def.tradewaste-para1.b" guid="_d3130c75-b1d5-4893-85b7-825a54951634" provision.type="other"><no>(b)</no><block><txt break.before="0">human waste; and</txt></block></li><li id="sch.6-def.tradewaste-para1.c" guid="_c553cf60-870a-42fc-b09c-2573b9049732" provision.type="other"><no>(c)</no><block><txt break.before="0">stormwater.</txt></block></li></list></definition><definition id="sch.6-def.trap_" guid="_35d23f30-b750-4b41-94e2-eca9c7ad9540" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.trap" guid="_32bcadf2-021c-4ff9-a799-acc565cf9e03" type="definition">trap</defterm> see glossary.</txt></definition><definition id="sch.6-def.trapwaterseal_" guid="_b3547e1a-7131-437b-89c5-7eb988bd1d20" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.trapwaterseal" guid="_4db8b84b-df5e-46f5-b4ee-04e8de0d86cf" type="definition">trap water seal</defterm> see glossary.</txt></definition><definition id="sch.6-def.upstreamvent_" guid="_854d5134-42fb-46d9-840f-bbbb337e7821" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.upstreamvent" guid="_b6a43745-0228-4b8d-ae78-86ce490d5654" type="definition">upstream vent</defterm> see glossary.</txt></definition><definition id="sch.6-def.urinal_" guid="_8b9731cb-bfed-49d2-b80a-718a5e5c9ec5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.urinal" guid="_884bb148-b317-4da6-9e8f-eba146f938e7" type="definition">urinal</defterm> see glossary.</txt></definition><definition id="sch.6-def.valve_" guid="_7f7a7266-be40-4522-bdf3-9ea9c7a4ea1f" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.valve" guid="_e54e5c67-1129-46d5-a03e-a852d3290fdd" type="definition">valve</defterm> see glossary.</txt></definition><definition id="sch.6-def.vent_" guid="_eeb1d04f-6ba1-4e65-94d4-ebc43615c562" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.vent" guid="_ee39d022-ed8d-41e3-a117-b85a151a4565" type="definition">vent</defterm> see glossary.</txt></definition><definition id="sch.6-def.ventpipe_" guid="_65685a6f-8b19-486a-978b-81f700700485" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.ventpipe" guid="_a9ff922a-085b-4c81-ac2b-60f6b2926b23" type="definition">vent pipe</defterm> see glossary.</txt></definition><definition id="sch.6-def.wastepipe_" guid="_eb2c723d-4eda-4aee-b9b7-e21a3376a0f6" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.wastepipe" guid="_7ed4b4ca-ebc8-48e0-82f2-3ca1e2a204d6" type="definition">waste pipe</defterm> see glossary.</txt></definition><definition id="sch.6-def.wastewater_" guid="_a3e047b5-1877-492f-8f0a-eed904d39fa4" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.wastewater" guid="_e28751cd-f835-45f4-b4d7-8c7ab79a68a2" type="definition">waste water</defterm> see glossary.</txt></definition><definition id="sch.6-def.waterclosetpan_" guid="_0e01246f-f5d6-4ebf-8061-3bd68cd2f8c5" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.waterclosetpan" guid="_c1b55ef4-0b12-4bd5-8454-fb40049656aa" type="definition">water closet pan</defterm> see glossary.</txt></definition><definition id="sch.6-def.waterclosetWCcistern_" guid="_2d2ab312-ee65-4e2d-bdd9-b22d2427aa6b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.waterclosetWCcistern" guid="_3d161415-fa03-4e34-a116-a16fb2762f03" type="definition">water closet (WC) cistern</defterm> see glossary.</txt></definition><definition id="sch.6-def.waterheater_" guid="_068bb030-5bcb-481a-a5f8-1b89ed3d6c43" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.waterheater" guid="_623f18e7-bd13-49aa-96f7-b7c958494909" type="definition">water heater</defterm> see glossary.</txt></definition><definition id="sch.6-def.watermain_" guid="_d0a79a71-6916-4bd7-936b-3060fdf8f765" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.watermain" guid="_5d3f53cc-141c-4821-baf7-19bb98a6872d" type="definition">water main</defterm> see glossary.</txt></definition><definition id="sch.6-def.waterplumbing_" guid="_457d2e41-d3bb-4507-8aa7-d7533d073d1a" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.waterplumbing" guid="_7aa704f4-45cd-42ef-a0e0-1ae9a5d7257b" type="definition">water plumbing</defterm> means an apparatus, fittings, or pipe for carrying water within premises.</txt></definition><definition id="sch.6-def.watersupply_" guid="_45622b3b-80c4-4662-aa8e-ddcad89c25e2" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.watersupply" guid="_f05354f2-0bbc-4456-8333-6257187ff1c9" type="definition">water supply</defterm> see glossary.</txt><historynote><txt break.before="1">def <defterm guid="_23b432fb-f29f-4996-9a91-484e431d1e3e" type="mention">water supply</defterm> ins <legref jurisd="QLD" type="subordleg" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="valid">2012 SL&#160;No.&#160;167</legref> <legref jurisd="QLD" type="subordleg" refid="sec.49" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">s&#160;49</legref><legref jurisd="QLD" type="subordleg" refid="sec.49-ssec.2" target.doc.id="sl-2012-0167" target.version.series="4d898f9c-5125-471f-b014-aeb6644bf111" valid.date="as.made" check="invalid">(2)</legref></txt></historynote></definition><definition id="sch.6-def.watersupplysystem_" guid="_ccc975c3-b309-46de-9061-2429bfc47f0b" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.watersupplysystem" guid="_b61d5ba9-4f06-42b7-b0d1-4cdfb9302044" type="definition">water supply system</defterm> means infrastructure used to reticulate and supply water, whether or not used also to store or treat water, and consisting of water mains, property services and some or all of the following—</txt><list number.type="manual" unnumbered.indent="0"><li id="sch.6-def.watersupplysystem-para1.a" guid="_9fb81971-7a70-4d2a-a426-7e8d048a720e" provision.type="other"><no>(a)</no><block><txt break.before="0">valves;</txt></block></li><li id="sch.6-def.watersupplysystem-para1.b" guid="_fd222e68-7246-4a6b-8796-5ed5dfe34946" provision.type="other"><no>(b)</no><block><txt break.before="0">engines;</txt></block></li><li id="sch.6-def.watersupplysystem-para1.c" guid="_a2d31a24-3767-4db9-ba5e-5ff76c27eaa1" provision.type="other"><no>(c)</no><block><txt break.before="0">pumps;</txt></block></li><li id="sch.6-def.watersupplysystem-para1.d" guid="_5b6a1f01-2e93-4b1f-9357-b09584d0ae1e" provision.type="other"><no>(d)</no><block><txt break.before="0">structures;</txt></block></li><li id="sch.6-def.watersupplysystem-para1.e" guid="_14563741-82c3-4200-8a56-3048a0ea96e5" provision.type="other"><no>(e)</no><block><txt break.before="0">machinery;</txt></block></li><li id="sch.6-def.watersupplysystem-para1.f" guid="_7821eacc-5ab5-417d-a4e7-e3d721a91182" provision.type="other"><no>(f)</no><block><txt break.before="0">works not mentioned in <intref refid="sch.6-def.watersupplysystem-para1.a" check="valid" target.guid="_9fb81971-7a70-4d2a-a426-7e8d048a720e">paragraphs&#160;(a)</intref> to <intref refid="sch.6-def.watersupplysystem-para1.e" check="valid" target.guid="_14563741-82c3-4200-8a56-3048a0ea96e5">(e)</intref>.</txt></block></li></list></definition><definition id="sch.6-def.wrapping_" guid="_b668d5f9-8880-4f7b-a40e-a0a2a79c7f72" affected.by.uncommenced="0"><txt break.before="1"><defterm id="sch.6-def.wrapping" guid="_6dc25a05-4620-4797-83a6-3480f554a769" type="definition">wrapping</defterm> see glossary.</txt></definition></deflist></block></schedule></schedules></subordleg>